presented at ku 50th annual geotechnical engineering ... · geotechnical design engineers must be...

45
Rudolph Bonaparte Ph.D., P.E., D.GE., NAE, F.ASCE Chairman and Senior Principal Geosyntec Consultants, Inc. and Professor of the Practice School of Civil and Environmental Engineering Georgia Institute of Technology November 8, 2018 54 th ASCE Karl Terzaghi Lecture Geotechnical Stability of Waste Fills Lessons Learned and Continuing Challenges presented at KU 50 th Annual Geotechnical Engineering Conference

Upload: others

Post on 09-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Rudolph Bonaparte Ph.D., P.E., D.GE., NAE, F.ASCE

Chairman and Senior Principal

Geosyntec Consultants, Inc.

and

Professor of the Practice

School of Civil and Environmental Engineering

Georgia Institute of Technology

November 8, 2018

54th ASCE Karl Terzaghi Lecture

Geotechnical Stability of Waste Fills – Lessons

Learned and Continuing Challengespresented at

KU 50th Annual Geotechnical Engineering Conference

Page 2: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

2

Academic Family Tree Back to Karl Terzaghi

Page 3: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

3

Organization of Lecture

• Background

• Where Did We Start

• (early 1980s to mid 1990s)

• What Did We Learn

• (by mid 1990s)

• Continuing Challenges

• (2010 to present)

• Observations and Recommendations In Light of

Continuing Challenges

Page 4: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Background

Page 5: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

5

Background - Magnitude of Challenge with Waste Fills (U.S.)

~2,000 active municipal solid waste (MSW) landfills

~10,000 closed MSW landfills, some are contaminated Superfund sites

1,000s of: Industrial waste impoundments and by-product landfills

Mine tailings impoundments

Coal combustion residual (CCR) impoundments and landfills

RCRA and TSCA hazardous waste (HW) landfills

Low-level radioactive waste and mixed waste (LLRW) facilities

Other types of solid waste fills

The design of waste fills is governed by regulations that often

require the use of soil-geosynthetic liner and cover systems,

making these facilities expensive to build. Airspace in them has

become valuable, and this has led to larger and taller structures

with larger consequences associated with failures.

Page 6: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

6

Background - Geotechnical Stability Considerations

Geotechnical design engineers must be cognizant of multiple

potential static and seismic failure and displacement modes, at each

stage of waste fill development.

Page 7: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

7

Background - Unstable Waste Fills Pose Risks to Lives,

Property, and the Environment + Economic Loss

OII contains solid and liquid

municipal and hazardous wastes

Rises nearly to 250 feet above

surrounding ground with steep

slopes up to 1.3H:1V (35o)

2,100 people live within 1,000 feet

of landfill

Pomona Freeway runs adjacent to

north slope

Consider consequences of failure in

major earthquake (PGABR = 0.61g

from nearby Mw = 6.9 MCE)See Kavazanjian et al. (2013),

11th Peck Lecture, for

comprehensive study of OII

Operating Industries, Inc. (OII)

Superfund Site, Monterey Park,

California

Page 8: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Where We Started

(early 1980s to mid 1990s)

Page 9: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

9

Where We Started (35 to 20 years ago)

Waste Fill Failures Drew the Scrutiny of Owners, Regulators,

and Geotechnical Engineers

Global MSW Landfill (1984)

Kettleman Hills HW Landfill (1988)

Crossroads MSW Landfill (1989)

Chiquita Canyon (1994)

Keller Canyon Landfill (1994)

Rumpke MSW Landfill (1996)

Mahoning MSW Landfill (1996)

Liner and cover system veneer stability failures1

1 Veneer stability failures were commonplace in the early to mid 1980s, virtually from the start of the use of

geosynthetics in liner and final cover systems

Page 10: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

10

Kettleman Hills HW Landfill Unit B-19, California (1988) Waste Mass and Liner System Interface Failure

In early 1988, a year after filling began and with the

waste mass in an interim configuration with a height

of about 90 feet, a 580,000 CY slope failure occurred,

with progressive movements of ~ 14 feet vertically

and ~ 35 feet laterally over several hours

Waste Movement

References: Mitchell et al. (1990, 1993); Seed et al. (1990); Geosyntec

(1991); Byrne et al. (1992); Stark et al. (1994); Filz et al. (2001)

Page 11: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

11

Kettleman Hills HW Landfill Unit B-19, California (1988) Waste Mass and Liner System Interface Failure

Forensic investigation revealed a

translational sliding mechanism

along liner-system interfaces

Slippage was observed to be at

the interface between the

secondary smooth HDPE

geomembrane and underlying

compacted clay liner (CCL); post-

failure testing produced

undrained residual interface

strengths of about 500 psf

Residual interface friction angles

of less than 10° were measured

along geosynthetic-geosynthetic

interfaces

Torn Geosynthetics

Analyses and physical modeling also showed that 3-D effects were important given

the waste fill geometry, and that the failure mechanism involved progressive loss of

interface strength (peak to residual)

Page 12: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

12

Kettleman Hills HW Landfill Unit B-19, California (1988) Lessons Learned

Many liner system interfaces are weak and exhibit

pronounced shear softening, with residual

strengths much lower than peak strengths

Liner system construction and waste placement

operations can induce movements to mobilize

post-peak interface conditions within the liner

system; this must be considered in design

Waste mass stability evaluations need to address

all interim waste filling configurations (“all

development phases”)

Geomembrane/CCL interface strengths are

sensitive to their compaction, moisture, and

shearing conditions

Conundrum - CCL compaction conditions that

favor low permeability and intimate GMB/CCL

contact also favor low interface shear strength

Page 13: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

13

Crossroads MSW Landfill, Maine (1989) Waste Mass and Foundation Soil Failure

Landfill foundation consists of very

sensitive (St ~ 5 to 10) glaciomarine

clay-silt layer with OC crust and ~ NC

at depth (>20 feet) (Presumpscot Fm)

Clay-silt layer served as in-situ

barrier layer, The 8-acre cell had no

constructed liner or leachate

collection and removal system

(LCRS)

With the waste height at 60 feet, and

after a period of heavy rain, a rapid (~

minute) retrogressive slide occurred

involving 650,000 CY of MSW

Sliding surface extended down into

the normally consolidated soil horizon

and waste blocks “rode” 100 feet on

remolded foundation soil

W E

References: Richardson and Reynolds

(1991); Luettich et al. (2015); Reynolds (2105)

Page 14: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

14

Crossroads MSW Landfill, Maine (1989) Waste Mass and Foundation Soil Failure

At 60-foot height, designers

estimated stability FS > 1.2

Original design was based on

laboratory measured

foundation shear strengths,

but only an estimate of the

MSW unit weight - post-failure

measured unit weights were

30% heavier than the estimate

The affects of liquids

(leachate, rainfall) on pore

pressure buildup in the waste

mass weren’t adequately

considered in the design

W E

The slide was trigged by the excavation (8 feet) of the stiff soil crust at

the eastern toe of the cell for construction of a new landfill cell – this led

to over-stressing and remolding of the sensitive foundation soil at the

toe, leading to an initial toe failure and then the retrogressive failure

Page 15: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

15

Crossroads MSW Landfill, Maine (1989) Lessons Learned

Waste unit weight is a critical design

parameter as waste self weight is the

most important loading component of

most waste fill structures

A clear understanding of the liquid levels

and pore pressure conditions in both the

waste fill and foundation soils under all

operating conditions is critical to the

satisfactory assessment of waste mass

stability

Each significant construction and/or

operational change in the field should be

evaluated prior to implementing the

change (e.g., excavation at toe which

triggered slide – unloading stress path

particularly problematic for sensitive soils)

For soft soil sites, the waste filling schedule

must account for the rates of foundation soil

consolidation and strength gain - classical

staged geotechnical construction

W E

Page 16: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

16

Rumpke MSW Landfill, Ohio (1996) Waste Mass and Foundation Soil Failure

Starting in 1940s, waste was placed in ravines

on the Rumpke property, directly onto native

clayey, colluvial soils that formed a mantle

over bedrock – landfilling continued until 1996,

to grades exceeding the design grades

A week prior to failure tension cracks were

observed at the top of the landfill

The morning of the slide, the toe of the landfill

began to move and increasing leachate seepage

was observed at that location, – at the same

time, the cracking at the crest was accelerating

After several hours of gradually increasing creep

rates, the slope failed retrogressively, starting at

the toe, over a timeframe of about 5 minutes

In that short time, 1.5-million CY of material slid

hundreds of feet into a deep adjacent excavationReferences: Geosyntec (1997), Hendron and Schmucker (1997);

Evans and Stark (1997); Stark et al. (2000a,b); Chug et al. (2007)

Page 17: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

17

Rumpke MSW Landfill, Ohio (1996) Waste Mass and Foundation Soil Failure

Forensic investigation showed that the slip surface

extended at a near vertical angle from the landfill crest,

through the waste, to the colluvial soil, where it followed

the bedding of the soil layer

Post-failure shear testing of the colluvial soil produced

fully-softened and residual friction angles in the range of

20° and 8°, respectively; computed average friction

angle at failure is about 12o

Leachate levels in the waste mass prior to failure were

later estimated to be substantial (~ 20-30 feet)

Due to delays in opening the lateral expansion, the

landfill top deck had been overfilled by 30 to 40 feet in

the 18 months prior to failure; and the average slope

was steepened from 3H:1V to 2.6H:1V; a proper

analysis of overfilling stability was not conducted

An excavation at the toe for an access road, freezing

conditions that impeded leachate drainage, and nearby

bedrock blasting, may have contributed to initial

triggering of the slide

Figure adapted from Stark et al. (2000b)

Page 18: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

18

Rumpke MSW Landfill, Ohio (1996)Lessons Learned

Foundation conditions for old-unlined waste

fills must be thoroughly understood if

additional filling, excavation, or expansion of

the fill is planned

Strain incompatibility between MSW (ductile)

and colluvial soil (brittle) can lead to uneven

development of shear resistance and strain

softening (post-peak shear strength) along

potential slip surfaces

Leachate buildup in old unlined waste fills can

reduce slope stability factors of safety and

contribute to the development of unstable

slope conditions

Operational activities (e.g., toe excavation) can

serve as triggers to slides at waste fills that are

already marginally stable

Page 19: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

What Did We Learn

(by mid 1990s)

Page 20: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

20

We Had Many Lessons Learned by the Mid to Late 1990s

(more than 20 Years Ago!)

1. Geotechnical site investigations are as important to the design of waste

fills as they are to any other type of critical geotechnical infrastructure

2. Waste materials have geotechnical properties that must be reliably

evaluated or conservatively estimated for design

3. Moisture conditions and liquid and gas pressures within the waste fill must

be reliably evaluated or conservatively estimated for design

4. Geosynthetic-geosynthetic and soil-geosynthetic interfaces can be weak,

very sensitive to moisture conditions, and exhibit shear softening

5. Project-specific soil and geosynthetic interface testing should be conducted

if there is any doubt about the adequacy of available lab databases to

represent the project-specific conditions

Page 21: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

21

We Had Many Lessons Learned by the Mid to Late 1990s

(20 Years Ago!)

6. Mobilized strength compatibility needs to be carefully considered with

respect to waste (often ductile), geosynthetic interfaces (often brittle and

strain softening), and foundations (can be sensitive, brittle, slickensided,

strain softening, undrained, and/or liquefiable)

7. Most waste fills will go through numerous interim waste configurations prior to

final closure and these must be addressed in the design drawings and

operations plans – this requires in-depth communications and agreement

between design engineers and owners/operators on the details of these

configurations

8. Failure of construction and operating personnel to communicate field

deviations back to design personnel during landfill operations (when the

designer may be no longer involved) can lead to problems – continuity of

personnel and institutional knowledge can be a big challenge over a multi-

decade facility life

Page 22: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Continuing Challenges

(fast forward to 2010 to 2017)

“So, Why do We Keep

Having These Waste Fill

Failures?”

Page 23: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

23

Waste Fill Stability Failures Have Continued to Occur on a

Regular Basis (more than one per year on average)

Matlock Bend MSW Landfill, TN (2010)

Confidential MSW Landfill, Eastern U.S. (2011)

Confidential MSW Landfill, Southern U.S. (2012)

Big Run MSW Landfill, KY (2013)

Chrin Brothers MSW Landfill, PA (2013)

Tri-Cities MSW Landfill, VA (2015)

Greentree MSW Landfill, PA (2017)

Confidential MSW Landfill, GA (2018)

Stability Issues at Elevated Temperature Landfills (ETLs)

Cover System Veneer Slides

TVA Kingston, TN (2008) and Duke Dan River, NC (2014) CCR Impoundment

Failures

Mount Polley, BC (2014) Tailings Pond Failure

Page 24: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

24

Confidential MSW Landfill Failure, Eastern U.S. (2011)Waste Mass and Intermediate Cover Soil Interface Failure

At the time of the failure in

September 2011, waste filling had

recently been completed in a landfill

expansion being built over the 180-

foot tall slope of a previously filled

landfill cell (veneer geometry)

Leachate recirculation at the site

had been in the range of 5 to 10

million gallons per year for many

years; a spray-on alternative daily

cover allowed high levels of

stormwater infiltration; the top deck

was flat; and dewatered sewage

sludge was being accepted

Reference: Unpublished Root Cause Analysis (RCA) Report (2012) [Tom Ramsey, Lucas

de Melo, Bob Bachus, David Espinoza, Ranjiv Gupta, and Chunling Li (Geosyntec)]

Failure occurred in the expansion area (waste veneer) in

a matter of minutes and involved ~ 160,000 CY of waste

that flowed ~ 500 feet beyond the limit of liner system

and retrogressed more than 100 feet behind the crest

Approximate

limit of landfill

~500 feet

Slope

Crest>100 feet

Page 25: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

25

Confidential MSW Landfill Failure, Eastern U.S. (2011)Waste Mass and Intermediate Cover Soil Interface Failure

Post-failure investigation showed

that the slip surface was at the

interface between the expansion

area waste and underlying

intermediate cover soil layer

Post-failure investigations using

CPTU testing around the

perimeter of the failed area

showed high piezometric levels in

the expansion waste mass

On-site observations the day after

the slide revealed leachate pools

within the failure area and clear

evidence of leachate overland flow

in and around the 500-foot off-site

waste runout

Intact intermediate

cover exposed

after failed waste

removal

Observers also heard gas escaping (“hissing sound”) from the

failure area, not surprising because the active gas removal system

in the area had been partially inoperable for several months

Page 26: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

26

Confidential MSW Landfill Failure, Eastern U.S. (2011) Waste Mass and Intermediate Cover Soil Interface Failure

Page 27: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

27

Confidential MSW Landfill Failure, Eastern U.S. (2011) Waste Mass and Intermediate Cover Soil Interface Failure

Slope stability analyses were conducted using

the CPTU-derived piezometric levels and the

observed failure surface location to back

calculate an average operative MSW shear

strength at the time of failure

Slope stability back-analyses resulted in a

drained waste friction angle of 26° (100 psf

cohesion assumed)

Direct shear tests on an MSW/sludge

(75%/25%) sample from the site, performed

at Arizona State University, resulted in drained

secant friction angles of 24° and 20°,

respectively, at 10 and 20 psi normal stresses

These calculated and measured MSW

strengths are lower than those for “typical”

MSW (e.g., Kavazanjian et al., 1995)

Page 28: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

28

Confidential MSW Landfill Failure, Eastern U.S. (2011) Lessons Learned

Excessive leachate recirculation and stormwater infiltration can lead to the

buildup of elevated liquid levels and pore pressures in the waste

Vertical expansions that involve the placement of new waste over old need to

account for the interface conditions

in this case, a low-permeability intermediate cover impeded leachate percolation

from the expansion area, contributing to leachate buildup

either the cover needed to be removed or breached, or a new LCRS placed on top

of it

Gas collection efficiency can be greatly reduced in excessively wet landfills,

both through operational problems such as the flooding of gas wells, and by

the reduction of MSW gas permeability at increasing levels of waste saturation

The effects of sludge on the strength (↓), permeability (↓), and degree of

saturation (↑) of the waste mass must be accounted for in design

Page 29: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

29

Confidential MSW Landfill, Southern U.S. (2012) Waste Mass and Foundation Failure

Landfill cell was constructed in

~ 60-foot deep excavation into

over-consolidated native fat clay

Excavation occurred in 1996 to

obtain borrow soil for ongoing site

operations, but cell construction

did not begin until 2007

For a decade, stormwater was

allowed to pond in the cell bottom

Waste filling occurred over four

years, from 2007 to 2011, creating

a slope 95 feet high inclined at

4H:1V

Cell underlain by CCL, geotextile,

and sand LCRS (liner system not a

factor in the failure mechanism)Reference: Unpublished RCA Report (2012) [Beth Gross and

Rodolfo Sancio (Geosyntec)]

Translational movement occurred over a

several day period ~ eight months after filling

was complete and after 3.5 inches of rain fell in

the preceding 48 hours

E W

Page 30: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

30

Confidential MSW Landfill, Southern U.S. (2012)Waste Mass and Foundation Failure

The first signs of a problem occurred

three months prior to the failure when

north-south oriented cracks

developed at the eventual location of

the slide head scarp

Owner/operator filled the cracks, but

they reopened with time, typically

after rain events

The slide involved translational

movement of ~ 700,000 CY of waste

and soil a distance of 25 feet

Based on 20 CPTUs, a few

piezometers and inclinometers,

and laboratory testing, the failure

involved shallow translational

movement in the native clay

beneath the bottom of the liner

Head scarp

(1,000-ft long,

30-ft deep

Translational

movement

(~ 25 feet)

N S

FUTURE CELL

OLDER CELL

SLIDING CELL

Intercell Berm

Shallow, weathered, native clay

estimated to be 50-75% consolidated

Page 31: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

31

Confidential MSW Landfill, Southern U.S. (2012) Waste Mass and Foundation Failure

Decade-long unloading (open

excavation), negative pore

pressures, and ingress of

ponded water through

desiccation cracks and

slickensides – this led to swelling

and softening of the clay and a

reduction in its shear strength

(fully-softened strength)

Waste loading, coupled with

excess pore pressures, was

sufficient to induce shear

deformations in clay leading to

progressive strength loss and

ultimately failure (fully-softened

→ residual)

GeometryShear Strength

Envelope (psf)

Elevation of

Failure PlaneRu FS

Post-Failure Residual 330 0.14 1.0

Pre-Failure Operative 330 0.14 1.0

Page 32: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

32

Confidential MSW Landfill, Southern U.S. (2012) Lessons Learned

A thorough understanding and application of fundamental soil behavior, pore pressure

response, and slope stability principles should be applied in the siting and design of waste fills

Engineers need to not only focus on the design of the waste fill itself, but also the placement of

the waste fill in the site-specific geological and geotechnical setting

In this specific case, the engineer needed to understand the potential for changes to

foundation soil shear strength due to the unloading and softening of the highly plastic,

overconsolidated, and weathered clay

Page 33: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

33

Greentree MSW Landfill, Pennsylvania (2017) Waste Mass Failure

In February 2017, a 15+ acre waste

slope failure occurred, resulting in a

worker fatality

In the weeks leading up to the

failure, surface cracking, slope

bulging, leachate seeps, and gas

venting were all observed; at the

time of the failure, the owner was

evaluating the cause(s) of these

issues and attempting to install gas

wells in the area to relieve pressure

The slope failure occurred over

about 10 minutes, starting with the

bursting of the bulging face of the

cell which triggered the larger slide,

releasing 220,000 CY of waste that

flowed several hundred feet

beyond the limit of the liner system Reference: Unpublished RCA Report [David Bonnett and

Youngmin Cho (Geosyntec) and Craig Benson (UVA)]

Truck cab

Page 34: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

34

Greentree MSW Landfill, Pennsylvania (2017) Waste Mass Failure

The area where the failure occurred

involved an expansion of a new

waste cell against the intermediate

slope cover of an older portion of the

landfill (again, veneer configuration)

Intermediate cover for the original

landfill consisted of cuttings from

O&G drilling operations blended with

lime, resulting in a relatively hard,

smooth, and impermeable layer

upon which waste was placed

(again, no removal/breaching or

overlying LCRS)

In addition to MSW, the landfill

accepted a variety of special wastes,

including sludge described as low

shear strength waste (LSSW)Prior to the failure, problems were encountered installing gas

wells and the gas extraction pipe header froze, together

enabling gas pressures to build up in the cell

Page 35: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

35

Greentree MSW Landfill, Pennsylvania (2017)Waste Mass Failure

The operations plan for the landfill

required LSSW to be placed 100 feet

back from the landfill edge of slope, to

prevent leachate seeps and to

maintain stability (a good idea)

The setback limited the cell area in

which LSSW could be placed and the

amount of MSW available for mixing

with the LSSW (because the MSW

was being used up to form the

setback zones)

This resulted in interior zones in the

cell (brown) with high proportions of

LSSW (an unintended consequence)

and ultimately a weak zone along

which shearing occurred

While the landfill only accepted about 20% LSSW

by total tonnage in 2015/2016, these operational

factors resulted in a zone in the landfill estimated

to have >40% LSSW

Page 36: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

36

Greentree MSW Landfill, Pennsylvania (2017) Waste Mass Failure

Representative samples of MSW

and LSSW were obtained from

bucket auger and sonic core

samples retrieved from the slide

area

Direct shear testing was

conducted on test specimens of

MSW, LSSW, and mixtures of

MSW + LSSW

Test results showed that

MSW/LSSW mixtures became

substantially weaker at LSSW

mass fractions above about 40%

At 70 to 80% LSSW content, the

mixture behaves similarly to

saturated bentoniteTesting was conducted by Chris Bareither and Joseph Scalia

at Colorado State University using Craig Benson’s shear box

Page 37: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

37

Greentree MSW Landfill, Pennsylvania (2017)Lessons Learned

Special (non-MSW) wastes can create

operational problems - procedures

developed to mitigate the problems can

have unintended consequences

LSSW (e.g., municipal and industrial

sludges) if placed at too high a mass

fraction, and if not thoroughly mixed with

MSW or other stronger waste, will create

weak zones that adversely affect waste fill

stability

Low permeability zones in the waste (from

LSSW, intermediate cover soil layers, odor

control layers) trap liquids and gases in

the waste fill causing fluid pressures to

become elevated

Page 38: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Observations and Recommendations in

Light of Continuing Challenges

Page 39: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

39

Observations and Recommendations:

Re-Learning the Lessons from 20 – 30 Years Ago

Thorough geotechnical site investigations and an in-depth

understanding of soil behavior and foundation response are essential

elements of the design of waste fills (e.g., Crossroads Landfill

[1989] and Confidential Southern Landfill [2012])

Operating conditions in the field can (and often do) deviate from the

design, resulting in the potential for unstable field conditions (e.g.,

Rumpke Landfill [1996] and Confidential Eastern Landfill [2011])

Coordination by the owner/operator with the design engineer is

essential throughout the facility life

Field deviations from design should be pre-checked by the design

engineer

Page 40: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

40

Observations and Recommendations:

Re-Learning the Lessons from 20 – 30 Years Ago

Waste properties (i.e., total unit weight, permeability, moisture content,

compressibility, and shear strength) must be reliably evaluated or

conservatively estimated for design

(e.g., Crossroads Landfill [1989] and Greentree Landfill [2017])

This is especially important for special wastes, special waste/MSW mixtures,

recirculation landfill wastes, and elevated temperature landfill wastes

Project-specific waste testing is recommended for these conditions

It is essential that design engineers have a thorough understanding of the

shear strength and deformation behavior of all interfaces that will exist in their

structure (Kettleman Hills [1988] and Chrin Brothers Landfill [2013])

Project-specific soil and geosynthetic interface testing should be conducted

Page 41: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

41

Observations and Recommendations:

More Recent Lessons Learned

Aggressive leachate recirculation to accelerate waste biodegradation (and to

reduce leachate off-site disposal costs) has had a number of unintended

consequences that can degrade waste mass stability (e.g. Confidential

Eastern Landfill [2011], and Big Run Landfill [2013])

Buildup of liquid heads in landfills

Watering out of gas wells and saturation of the waste

Reduction in the gas permeability and buildup of gas pressures

Increasing landfill temperatures leading to faster/greater waste degradation

Recirculation rates need to be moderated, landfill internal drainage features

enhanced, and proper water balance maintained when recirculation is used -

this will have a cost to the owner, but also a large benefit (fewer stability

issues, fewer elevated temperature issues)

Page 42: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

42

Observations and Recommendations:

More Recent Lessons Learned

Co-disposal of special wastes with MSW can lead to geotechnical stability

and other problems (e.g., Confidential Eastern Landfill [2011] and

Greentree Landfill [2017])

Owners/operators should have their engineers develop detailed special

waste acceptance plans (SWAPs) for each special waste stream

The SWAPs should consider the influence of the special waste on leachate

and gas generation, waste properties, slope stability, and operations

Unintended consequences of special operating procedures must be carefully

considered (unintended consequence analysis)

A higher level of operating vigilance is needed in fills that accept special

wastes – engineers should integrate the classical observational approach

into the operating plans they prepare as part of their designs

Page 43: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

43

Observations and Recommendations:

More Recent Lessons Learned

The cost and permitting challenges in developing greenfield sites is leading to

the increasing use of vertical and lateral expansions at existing waste sites

(Confidential Eastern Landfill [2011], and Greentree Landfill [2017])

Vertical expansion configurations and materials have contributed to landfill

problems

The intermediate cover interface must be carefully engineered for stability

and permeability

in some cases, the cover should be removed, or at least breached

in others, a new LCRS should be installed on top of the cover

The effects of the vertical expansion on the properties of the original waste

mass must be carefully considered [density (↑), saturation (↑), gas

permeability (↓)]

Page 44: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

44

Estimated Annual Probabilities of Failure

– Earth Dams and MSW Landfills

Silva, Lambe, and Marr (2008) - “Probability and Risk of Slope Failure.”

Page 45: presented at KU 50th Annual Geotechnical Engineering ... · Geotechnical design engineers must be cognizant of multiple potential static and seismic failure and displacement modes,

Thank You