Presentation On Sea Water Flue Gas Desulperisation System
Why FGD? Burning of fuels like Coal & oil produces a colourless
Gas - Sulphur Di-Oxide So2 is very harmful to the environment & we know
that it causes Acid Rain; harm ful to plants environment
&
By employing FGD units, S02 emissions are cut down;
thus we will strive closer to a clean environment
Current Methodologies Dry Absorption injection Systems
Spray Dry scrubbing (using sorbet slurries) Wet Scrubbing
Emission Guarantees So2 Removal Ph COD increase
-
89% 6.5 2.5 mg/Ltr 60 % @ 20- 25 Deg C 70 Deg C
DO Dissolved Oxygen Stack Inlet Gas Temp -
Emission Guarantees Sea Water Temperature rise Increase of TSS Power Consumption
-
4 Deg C 10 ppm 38 MW (3 units)
The ProcessSea Water
Flue Gas
Dust Removal
So2 Absorption
Reheat
Treated Gas
Sea Water
Sea Water Treatment Plant
Air
Treated Sea Water
FGD System ComprisesGas CircuitBooster fan GGH Absorber
Water CircuitDilution Pump House Absorption Pump House
SeaWater Treatment PlantAeration Fans
FGD System ComprisesAuxiliary/ Common SystemCooling Water Pump HouseCCC Pumps ACW Pump
Chlorination System Compressed Air System
Single Line Diagram
ReactionAbsorption SO2 + H2O SO32- + 2H-
So2 is absorbed in sea water
ReactionOxidation SO3 2- + 1/2O2 SO4 2(Sulphate ions)
SO3 2- Consumes oxygen to form sulphate Sea Water is further oxygenated to complete the oxidation reaction, and to bring the Dissolved oxygen to an environmentally acceptable level
ReactionNeutralisation HCO3- + H+ Co2 + H2O
Bicarbonate ions in the sea water react with hydrogen ions, hence neutralises the acidifying effect of the sulphur oxidation and thereby raising pH
Gas Circuit
Single Line Diagram
Gas Circuit70 Deg C 136.9 Deg C
Outlet Damper FGD Bypass Damper FGD Inlet Damper
Booster Fan Type of Fan Blade Type Rated Capacity Suction Pressure Static Pressure
-
Axial FlowVariable Pitch Blade 25,20,000 Nm3/hr 100 Pa 3100 Pa
Temp/Density of gas Rated Power of Motor
-
136 deg/ 0.886100 kw
GGHGas to Gas Heater As the name implies it takes heat from the hot flue gas
and reheat the clean flue gas coming out of the absorber and let it to the chimney
GGH Type Heating Surface area Speed of rotation Drive
-
Bi-Sector8600 sq.m 2 rpm Motor Driven
Absorber Absorber is a concrete structure which houses the sea
water distribution pipes & fill packs It acts like a cooling tower
Flue gas to Seawater interaction takes place And So2 is absorbed from flue gas by sea water and
clean gas leaves to GGH
Absorber
Absorber Lining Lining Material Make
Ceilkote 242 MR FlakelineAkzo Noble International Paint Co Ltd., 2.5 to 3.2 mm 48 hrs
-
Coating Thickness Curing Time
-
Water Circuit
Single Line Diagram
Dilution Pump House It takes water from sea water reservoir
Pumps
the water to Absorption pump house
forebay/Distribution Channel
And Part of the water is sent to aeration basin for
diluting the effluent water
Steel Gate
Trash Rack
Dilution Pump House
Travelling Screen
Dilution Pump Capacity Head Speed
-
35000 cum/hr 11.3 m 370 rpm
Motor Capacity MOC Casings Shaft
1500 kw , 11 KV
-
HT200Ni2Cr022Cr22Ni5Mo3N
Absorption Pump House Pumps the sea water to absorbers located in unit 7, 8 &
9 for absorption of so2 from flue gas through FRP
piping.
Absorption Pump House
Absorption Pump Capacity Head
-
15700 cum/hr 18.2 m
Speed
-
495 rpm1100 kw , 11 KV
Motor Capacity -
Sea Water Treatment Plant
Aeration Fans - Function Takes air from atmosphere
Pressurises and send the air to distribution pipes,
which are submerged by the effluent water from absorber. Thereby Dissolved oxygen is increased in the water &
discharged to outfall channel.
Aeration Building Cross Sec
Aeration Fans - Spec Type Flow
-
Radial Flow Fan 27.07 cum/s (110 TPH)
Pressure Speed
-
30 kPa2970 rpm
Motor Capacity -
1120 kw, 11 Kv
Auxiliary Systems
Cooling Water Pump House Function of cooling water pump house is to provide
cooling water for HT motors & cooling of lub oilsystem & equipment bearings
Cooling Water Pump House It comprises CCW Pumps
ACW Pumps Plate Heat Exchangers Rotary Filters
Cooling Water System - SLDDM Water from Phase IV OH Tank
CCCW Pump
ACW Pump
PHETo BoosterFan To Compressor To Chlorination Sys To Dilution pump To Absorption Pump To Aeration System
Forebay
CCCW Pump Capacity Head
-
1562 cum/hr 41 m
Speed
-
1480 rpm250 kw , 11 KV
Motor Capacity -
ACW Pump Capacity Head
-
2015 cum/hr 17.6 m
Speed
-
980 rpm160 Kw, 415 v
Motor Capacity -
Chlorination System
Purpose To dose the chlorine in the intake channel of Dilution
Pumps It controls microbes like algae
Acts against Odor
Chlorination System- SLD
Booster Pump 120 Cum/hr Filter Hypo-Chlorite Generator
Hypochlorite Storage Tank
Sea Water From ACW SystemDosing Pump 192 Cum/hr To Dilution Pump Intake
Chlorination Sys - Spec Type Generation Capacity
-
Electrochlorination 2 x 186 kg/hr
Sea Water Booster Pump Continuous dosing Pump
-
120 cum/hr (3 Nos)192 cum/hr (2 nos)
Hypochlorite Storage Tank
-
50 cum (3 nos)
Compressed Air System Type of Compressor Capacity
-
Screw Compressor 35 cum/min
Pressure Speed
-
1 mpa2980 rpm
Power
-
260 kw, 11 Kv
Electrical Scheme220 KV Line 1 from Phase I 220 KV Line 2 from Phase I
220 KV Bus 1 220 KV Bus 2
66/ 11 Kv 11 Kv Bus
Dilution Pump
Booster Fan
Absorption
Aeration
CCW
Chlorination
An Overview Civil StructuresName of Structure ABSORBER Absorber (Unit #7,#8,#9 each) Duct Support (Unit #7,#8,#9 each) Booster Fan (Unit #7,#8,#9 each) SWTP Dilution Pump House Absorber Pump House Cooling Water Pump House Aeration Basin 16,150 2,650 400 10,800 1,800 750 700 Appx. Concrete (CUM) Total Concrete (CUM) 9,750 5,400 2,250 2,100 52,100 16,150 2,650 400 10,800
Aeration EnclosureOutfall Channel Chlorination Building EC Building ( 2 Nos) GRAND TOTAL
3,0504,650 650 750
3,0504,650 650 1,500 58,000
An Overview Mechanical StructureCommon System1 2 3 4 5 6 7 8 9 10 Dilution Pump house steel structure & EOT Dilution Pumps - 5 nos Absorption PP house steel structure & EOT erection Absorber Pumps -4 Nos. Compressed Air system ACW/CCCW system Chlorination system DG House structure + DG Set FGD Pipe / Cable Rack Str. Cooling water and service water piping MT MT MT MT MT MT MT MT MT MT 400 400 388 240 80 100 65 80 350 130
11
FGD GRP PipeTotal
MTMT
27124945
An Overview Mechanical StructureUnit 7 Equipment1 2 3 4 5 6 7 8 Unit-7 FGD Gas duct support Str Unit-7 Ducts Unit-7 Booster Fan Unit-7 GGH steel structure Unit-7 GGH Proper Aeration Fan enclosure #7 - 03 Nos. Unit-7 Seal Fir fan-2 nos Unit-7 Absorber Total MT MT MT MT MT MT MT MT MT 340 670 112 260 313 54 30 90 1869
An Overview Mechanical StructureSummary
Common System Unit 7 Equipment Unit 8 Equipment Unit 9 Equipment
-
4945 MT1869 MT 1868 MT 1868 MT
Total
-
10550 MT
Benefits/ Features of SWFGD Simple & reliable Proven Technology
Uses only sea water & air No by-product handling No Chemicals Addition Fully automated operation Meeting emission standards