    Grounds

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    3/24

    Electrical Ground actually a path forcurrent to return from some load back

    to the source.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    4/24

    A Ground to earth is REQUIRED of mostelectrical equipment to protect against

    shock hazard!

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    5/24

    Proper Grounding is EXTREMELYIMPORTANT for minimizing EMI

    problems.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    6/24

    Grounds Symbol :

    1. Signal/Earth Ground2. Chassis Ground3. Special Ground

    (1) (2) (3)

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    7/24

    Bond Wires

    Circuit connected to Ground using bondwires.

    Keep leads short and keep impedancelow.

    Lower inductance is attained using flat,wide-cross-section conductive straps.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    8/24

    Signal Grounds

    1. Single-Point

    Tying the grounds together at a singlepoint,so all signal ground will be at the

    same potential. The facility ground may not be

    equipotential.

    Avoid significant difference in the groundpotential in some case (ex: lightning strike).

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    9/24

    Ground Loop

    Circuit

    FacilityGround

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    10/24

    1. Single-Point

    a) Series-Connected Single-Point

    Circuit 1 Circuit 3Circuit 2

    Source

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    11/24

    Very commonly used.

    Can see a potential difference at

    the ground level that can affectoperation and cause EMIproblems. For this reason, the

    bond leads must be kept as shortas possible.

    a) Series-Connected Single-

    Point

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    12/24

    1. Single-Point

    b) Parallel-Connected Single-Point

    Circuit 1 Circuit 3Circuit 2

    Source

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    13/24

    b) Parallel-Connected Single-

    Point Offers much better EMI control.

    The circuit operates best at lowfrequency where the wireinductance is low.

    Can require an excessive amountof wire for a large system.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    14/24

    Signal Grounds

    2. Multipoint Arrangement

    Circuit 1 Circuit 3Circuit 2

    Source

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    15/24

    2. Multi-Point Arrangement

    A better approach for highfrequency.

    Work best for frequencies above10 MHz.

    It is CRITICAL that the groundleads from circuit to the commonground plane be as short as

    possible (preferably less than

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    16/24

    Loop Area

    IC

    +5V

    IC IC

    IC

    +5V

    SmallerLoop AreaLarger

    Loop Area

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    17/24

    Loop Area

    A circuit containing : a source,connecting wire, load, and groundcreates a current loop that resemblesa loop antenna. It can serve an

    unintentional source of radiatedemissions and also susceptible toreception of incident fields (ex: fromradio transmitters)

    Because of radiated power from a loopantenna is proportional to the looparea squared, the area enclosed by

    these current loops should beminimized to reduce EMI.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    18/24

    Shields

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    19/24

    Shields is metal or metal screen boxplaced around circuit to block radiation.

    Metal/ metal box/ metal braid Shield attenuate electromagnetic

    wave and reflect waves

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    20/24

    Fundamentals of Electromagnetics With Engineering Applicationsby Stuart M. Wentworth

    Copyright 2005 by John Wiley & Sons. All rights reserved.

    Figure 9-23 (p. 479)Some of a field Ei incident on a shield will be reflected at the air -shield boundary,

    some will be transmitted and attenuated within the shield, some will be reflected at

    the shield-air boundary, and finally some will be transmitted as Et.

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    21/24

    Shielding effectiveness = SE

    SE adalah tingkat performa Shield,didefinisikan sebagai desibel

    SE = 10log (Pns/Ps) = 20log (|Ens|/|Es|)= 20log (|Hns|/|Hs|)

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    22/24

    Atenuasi (attenuation) atau absorsimengkonfersi energi electromagneticmenjadi panas dalam materi Shield

    Material dengan permebealitas tinggimembuat proses absorsi yang bagus,karena

    =

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    23/24

    SE tergantung dari : komposisi dan ketebalan Shield itu

    sendiri

    Frekuensi radiasi gelombangelektromagnetik

    Bentuk dari Shield itu sendiri

    Diskontinuitas yang mungkin beradadalam Shield

  • 7/31/2019 Presentasi Elektromagnetika Ground & Shield

    24/24

    Dalam Shield terkadang terpadatbeberapa lubang yaitu: Opening untuk mnejalankan sinyal,

    power dan koneksi grounding

    Ventilasi Shield

    Lubang yg tidak tertutup sempurna pada

    penggabungan dua Shields

    Lubang-lubang ini terkadangmengurangi integritas SE