Pre-Shipment Inspection Report
I. GENERAL INFORMATION
Service Performed: Pre-Shipment Inspection
Client: XXX
Supplier: XXX
Factory: XXX
Product Name: Lock & Lock MiNi Blender
P.O. No.: 4900010870
Item No.: EJM331
Destination Country: XXX
Inspection Date: 27 July 2016
Inspection Location: China
Reference Sample: No Sample
II. INSPECTION SUMMARY
Passed Failed Pending N/A
A. Quantity
B. Workmanship
C. On-Site Tests
D. Product Specification
E. Packing
F. Marking & Labeling
G. Client Special Requirement
Workmanship Summary
Inspection Standard: ANSI/ASQ Z1.4 Critical Major Minor
Sampling Plan: Normal, Single AQL: Not Allowed 2.5 4.0
Inspection Level: Level II Accepted: 0 10 14
Order Quantity: 6504 Found: 0 2 8
Available Quantity: 6504 pcs (100%) Result Within AQL
Sample Size: 200
III. Remarks
Problem Remarks:
1. Nil
General Remarks:
2.
For CDF check, the result was as below table,
Component Actual Conform to CDF or not
Plug Guangzhou xxx Qiu, HQ-B201, AC 250V, 2.5A,VDE
Conform
Power cord Guangxxx Qiu,H03VVH2-F, 2x0.5mm2,VDE
Conform
X capacitor Dain, MPX, 0.39uF, AC 275V, X2,T110,VDE
Conform
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 2 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Y capacitor JEC,JY, 4700uF, 300V, Y2,VDE Conform
Motor Harvest, H5425M23, 220-240V, 50/60Hz,250W, Class B
Conform
Thermal link for motor Changzhou xxx KW-A2, 105°C, 250V,VDE
Conform
Internal wire SHUNDE xxxx, 1015, 20-24AWG, 105°C, 600V
Conform
Micro-switch Zhongshanxxxx, WS-3, 250V, 3A,TUV
Conform
3. The Logo sticker on the bottle was skew in 30% of selected samples. It was confirmed by client.
4. All gift boxes were not sealed well inside the carton and it was confirmed by client. Please refer to below photo for details.
5. For plastic bottle water leakage test, as client's requirement, the bottle was filled in max water level and horizontal placed for 10mins and the result was OK.
6. No silica gel including in the package.
7. When the inspector left the factory, the factory had not started re-packing the inspected samples. Only one carton was re-packed for reference.
8. The factory was requested to repair, replace the defective products our inspector found during the inspection.
Factory Information:
9.
Factory cooperation: □ Good - Enough manpower to assist, and good cooperation.
Average - Enough manpower to assist. □ Poor - Manpower, equipment or document not provided timely.
10.
Number of workers in factory: □ Less than 50 people □ 50-100 people □ 100-500 people □ 500-1000 people
□ More than 1000 people
Unknown
11.
The observed level of production/manufacturing activity at the inspection site was: □ Extremely busy
Normal activity □ Low activity □ N/A (Reasons: Inspection was held at warehouse or port. / Inspector had no access to workshops. / Factory was
unwilling to disclose information, etc)
12.
Inspector's opinion on the factory: □ Good - The factory was neat and tidy. The testing equipment was well maintained and calibrated.
Average - The factory was tidy, and the testing equipment ran normally. □ Poor - The factory was messed, the basic testing equipment was not available / not workable.
Sample Collection Record:
13. No sample was collected on site.
Photos:
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 3 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Remark 3, The Logo sticker on the bottle was skew in 30%
of selected samples. Remark 3, The Logo sticker on the bottle was skew in 30%
of selected samples.
Remark 3, The Logo sticker on the bottle was skew in 30%
of selected samples. Remark 3, The Logo sticker on the bottle was skew in 30%
of selected samples.
Remark 4, All gift boxes were not sealed well inside the
carton, but client have confirmed it on site. Remark 4, All gift boxes were not sealed well inside the
carton, but client have confirmed it on site.
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 4 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
IV. CONCLUSION
PASSED
PASSED - Conform to Client's Requirement PENDING - Subject to Client's Evaluation FAILED - Not Conform to Client's Requirement
Approved by : Tony Lee, Manager of Report Reviewing
Inspector & Report Reviewer:
Inspector(s): Jenson Liu Report Reviewer: Second Zeng
Should you have any question, please contact us:
Ellen Yao Account Manager E: [email protected] T: +86-20-89089938-823 M: +86-13826082485
Clara Chen Vice General Manager-Customer Service E: [email protected] T: +86-20-89089928-802 M: +86-13600063774
Note: 1. This report reflects our findings at the time and the place of inspection based on random samples selected. 2. This inspection was carried out to the best of our knowledge and abilities, and our responsibility is limited to the exercise of reasonable one. 3. This report does not relieve the sellers from their contractual obligations nor does it prejudice buyer's right for compensation for any apparent and/or hidden defects not detected during our inspection or occurring thereafter. 4. This report does not evidence shipment. 5. Our services are subject to the General Conditions of Service of V-Trust, which is shown at our website and can be sent to you upon written request. 6. This report's inspection results only relate to the samples as (randomly picked) by our inspector. 7. This report is complete and its content may not be reproduced. ************************************************************************************************************************************************************** Please find our inspection details from next page.
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 5 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
A. QUANTITY
Quantity Unit: pcs
P.O. Item Order Qty
Qty / Carton
Order Cartons
Quantity Breakdown Sample Size
Packed Unpacked Unfinished Packed Unpacked
4900010870
EJM331 6504 6 1084 6504 0 0 200 0
Total: 6504 - 1084 6504 0 0 200 0
Selected Cartons :
34 Cartons were selected randomly on site. No carton number in shipping mark.
Carton No.:
/ / / / / / / / / / /
Result: Passed
Remark:
B. WORKMANSHIP
Inspection Standard: ANSI/ASQ Z1.4 AQL Accepted Total Found Result
Sampling Plan: Normal, Single Critical: Not Allowed 0 0 Passed
Inspection Level: Level II Major: 2.5 10 2 Passed
Sample Size: 200 pcs Minor: 4.0 14 8 Passed
Workmanship Defectives / Function Inspection Findings
Description Critical Major Minor
For Item EJM331 (4900010870) Sample Size: 200 pcs
1. The feet was not flat (gap about 1mm) 2
2. Scratch mark on body 4
3. Bits inside sticker 1
4. Scratch mark on bottle 2
5. Sticker out of position 1
Total found: 0 2 8
Accepted: 0 10 14
Sample size: 200 200 200
Result: Passed
Remark:
Note: Defective is defined as a unit of product that contains one or more defects. A Defect is defined as any non-conformance of the inspected unit of product with specified requirements. A single defect is taken into account per each defective unit; only one most serious defect is taken into account per each defective unit.
1 Defect photos of Items: EJM331 (4900010870)
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 6 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
The feet was not flat (gap about 1mm) The feet was not flat (gap about 1mm)
Scratch mark on body Scratch mark on body
Scratch mark on body Scratch mark on body
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 7 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Bits inside sticker Scratch mark on bottle
Scratch mark on bottle Sticker out of position
C. ON-SITE TESTS
Description Method Sample Size Result / Reading
1. Function check
1. According to the description on the item's box and in the instruction manual. 2. Test the power on/off function 5 times 3. Test the indicator light if applicable. 4. Speed dial function test if applicable 5. Safety switch test if applicable 6. Normal power consumption, normal speed level, normal noise level, no Malfunction No critical malfunction
200 pcs Passed
2. Assembly check
Assemble the unit according to the description. (e.g. user manual or instruction sheet or any packing). Easy to assemble
200 pcs Passed
3. Fatigue Test 20times for each button, plug and switch. No damage or block
8 pcs Passed
4. Rub Check
Use cotton dripped with water, rub the marking on rating label and silk-screen printing or electro-plating by hand for 15 seconds. Marking is clear after the rub, no peel off or lite
2 pcs Passed
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 8 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
upward on rating label.
5. Tape Check
Use the 3M (600) gummed tape to paste total cover the printing or electro-plating, peel the tape at 90°±30° rapidly; Marking is clear after the test, no peel off on plating.
2 pcs Passed
6. Stability Test
Place the product in the most unfavorable position under normal use 10degree incline, the product does not cause a plane inclined plate slide. No overturn or tip over
3 pcs Passed
7. Running Test Max setting, for 4 hours running. No malfunction and safety issue
3 pcs Passed
8. Carton drop test One corner, three edges, six sides, at height of
30inch (﹤9.5kg) on the cement floor. No unit drop out, no any damage on unit.
1 carton Passed
9. Hi-pot test 1S, setting. 3500V for class II; 1500V for class I No breakdown
200 pcs Passed
10. Input Power check
Motor appliance: within +20% of 25W~300W, Rated: 250W Within tolerance
200 pcs
Passed Without load: 110-
150W With load: 200-260W
Lock motor: 550W(max)
11. Pull test and Strain relief for power cord
25 times, for 2s, displacement≤2mm with pull force:
30N (≤1kg), 60N(1-4kg) or 100N (﹥4kg) Within tolerance
3 pcs Passed
12. Internal test
According to the BOM provided by client. 1. Take all related picture to show each main component and prepare a list of them. 2. Check and show the quality of welding. 3 .If the earth pin or any pin is not connected to a wire; fail the test and put an important remark. IF the product is a class 2 product and only the earth pin is not linked to a cable, test result should not change but write an important remark. No damage on component
3 pcs Passed
13. Abnormal test
-- Lock the motor for motor-operation products -- Switch on the product until it reaches overload condition Fuse shall work and no safety issue.
1 pc Passed
14. Standby/Off powe test for ErP
The standby power should less than 1W or the off power should less than 0.5W Within tolerance
200 pcs Passed
off power:0.1W and no standby power
15. Spark check Should no spark during switch on/off, running, spring operation or any other operation No failure
200 pcs Passed
16. Smell check
When the appliance is OFF, there is no unpleasant smell. When the appliance is switched ON at Max. Power, there is no burning smell. When open the unit, there is no odor inside the unit. No failure
200 pcs Passed
17. Application test Use food for real function check No failure
3 pcs Passed
18. Noise level check
Apply rated voltage at highest setting. 1m away, use the noise meter to measure. Mark the background noise level. (sound pressure level) Actual recording or compare the requirements.
3 pcs Actual Finding
81-88dB
19. Rotation speed check
Use tachometers, aligning the maximum speed of the blade and reading.
3 pcs Actual finding #01:20054rpm
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 9 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Actual recording or compare the requirements. #02:21139rpm #03:24037rpm
20. Low voltage start up check
85 % rated voltage, should start up normally No failure
3 pcs Passed
21. Water capacity check
Fill water to the Max level marking, Check the capacity by weight or volume, within ±5% tolerance No failure
3 pcs Passed 505ml
22. Water leakage check
Fill with water, oil or other available liquid for 4hours, should no leakage No failure
20pcs Passed
Result: Passed
Remark:
*Refer to V-Trust Work Instruction: VTR-WI-CZ-1000.
D. PRODUCT SPECIFICATION
Client's Spec. Ref. Sample 1# Sample 2# Sample 3# Sample
Item No.: EJM331 (4900010870)
L×W×H (mm) 113.6x111.6x374 / 113.2x111.1x375 113.2x111.1x375 113.2x111.1x375
Net Weight (kg) 1.14 / 1.14 1.13 1.14
Gift box size (cm)
/ / 27.5x13.5x22 27.5x13.5x22 27.5x13.5x22
Gift box weight (kg)
1.35 / 1.41 11.39 11.41
Cord length (cm)
/ / 75 75 75
Result: Passed. The actual measuring difference was within client's tolerance.
Remark:
E. PACKING
Package Details
Item No. Qty / Carton Carton Size (L×W×H, cm)
Gross Weight (kgs)
Qty / Inner box
Marking / Spec.
Actual Marking / Spec.
Actual Marking / Spec.
Actual Marking / Spec.
Actual
EJM331 (4900010870)
6 6 41.5x28.8x46.5 42x29x46 8.65 8.88 / /
Export Carton Details
Fastening Metal Staples No Nylon Band No
Material Cardboard Corrugated Paper Plies 5-ply
Packing Method
Each set with accessories, warranty card and IM packed with poly bag and cardboard into a gift box and then 6pcs gift box packed into a carton
Assortment Method
No assortment
Result: Passed. The actual measuring difference was within client's tolerance.
Remark:
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 10 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
F. MARKING & LABELING
Barcode/Labeling/Printing
Name Location Result
Barcode Gift Box Passed
Rating label Unit Passed
Warning word/marking Unit,Gift Box Passed
Logo Unit,Carton,Gift Box Passed
Instruction manual and documentation check Shi Provided By
The functionality description in English on the instruction manual is adopted on the actual unit.
Client, Factory Passed
The components of inspected samples were compared with the provided CDF.
Factory Passed
Shipping Marks
Shipping Marks (on 2 Side ) Passed
Side Marks (on 2 Side ) Passed
Inner Box Marks (on 0 Side ) N/A
Result: Passed
Remark:
G. CLIENT SPECIAL REQUIREMENT
Client Requirements Result
1. Nil N/A
Result: N/A, No client special requirement
Remark:
H. PHOTOS
1 Photos of EJM331 (4900010870)
Carton Shipping mark
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 11 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Side mark Shipping mark
Side mark Open
Gift box Gift box
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 12 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Gift box Gift box
Gift box Gift box
Gift box Gift box
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 13 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Gift box Gift box
Gift box Gift box
Gift box Gift box
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 14 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Open Packing
Poly bag All parts
Warranty card Warranty card
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 15 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Instruction manual Instruction manual
Instruction manual Instruction manual
Instruction manual Instruction manual
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 16 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Instruction manual Instruction manual
Lid Detail
Detail Bottle
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 17 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Bottle Bottle
Bottle Bottle
Main body Front
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 18 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Switch Logo
Side Back
Side Top
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 19 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Blade Detail
Detail Detail
Detail Detail
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 20 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Bottom Feet
Rating label Cord
Cord Plug
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 21 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Plug Assembly
Nil
Assembly Nil
2 Photos of On-Site Tests
Internal check Internal check
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 22 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Internal check Internal check
Internal check Internal check
Internal check Internal check
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 23 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Internal check Internal check
Internal check Hi pot test
Hi pot test Power consumption test
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 24 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Power consumption test Power consumption test
Power consumption test Off power test
Off power test Low voltage start
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 25 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Low voltage start Motor rotational speed test
Motor rotational speed test Motor rotational speed test
Motor rotational speed test Application test
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 26 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Application test Application test
Application test Application test
Abnormal test Abnormal test
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 27 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Capacity check Tape test
Barcode scan test Barcode scan test
Stability test Cord pull test
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 28 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Cord pull test Noise check
Noise check Noise check
Noise check Noise check
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 29 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Running test Leakage test
Leakage test Leakage test
Leakage test Leakage test
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 30 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Leakage test Drop test
Nil
Drop test Nil
3 Photos of Other Information
Goods in warehouse Goods in warehouse
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 31 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Goods selection Inspection site
Inspection site Inspection site
Inspection site Stamp
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 32 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Calibration label Weight check
Weight check Weight check
Weight check Weight check
Client Name: XXX Conclusion
Inspection Number: L076523 PASSED
Report Date: 28 July 2016
Page 33 of 33
Address: 1507-1509 West Tower, Poly World Trade Centre, 1000 Xingang Road E., Guangzhou, China Tel: +86-20-89089938 Fax: +86-20-89089025 E-mail: [email protected] Website: www.v-trust.com
V-TRUST Copyright © All Rights Reserved VTR-QR-CZ-RF-003 V7
Weight check Size check
Size check Size check
Nil
Size check Nil
*********************************************** This is The End of the Report *******************************************