Plug on Type MCBs & Distribution Boards Intelligent Choice for Prestigious Buildings

Upload: vuongthuan

Post on 22-Apr-2018

242 views

Category:

Documents


10 download

TRANSCRIPT

Page 1: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

Plug on Type MCBs & Distribution BoardsIntelligent Choice forPrestigious Buildings

Page 2: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against
Page 3: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

Table of ContentsQO Series Miniature Circuit Breakers

Specifications

QOvsRCBO Residual Current Circuit Breakers

with Integral Overcurrent Protection

QOE QWIK-GARD Residual Current Circuit

Breakers with Integral Overcurrent Protection

QOvs Miniature Circuit Breakers

LoadCentre Distribution Boards

Specifications

Rated Current 100A

Rated Current 200A

CLASSIC Metal Consumer Units

Specifications

Rated Current 100A

Certificates

1

2

3

4

6

8

9

10

11

11

12

Page 4: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

2

QO Series Miniature Circuit Breakers

Specifications

Comply with BS EN 60898.Comply with BS EN 60947-3 : 1992.Add i t i ona l sa fe ty requ i rements fo r Disconnectors and Switch Disconnectors as referred to in BS 7671.Trip-free handle ensures tripping even when the circuit breaker handle is held or locked in the ON position.To restore service, simply switch the indicative buttom from OFF to ON position once the fault has been cleared, which completely eliminates the cost and inconvenience of replacing fuse links or fuse wire.

All circuit breakers fit all LoadCentre Distribution Boards and Consumer Units in the range.Plug-on circuit breakers are tamperproof and provide positive connection to the busbar in one quick operation.Easy for installation and maintenance, with labour cost saved up to 50%.Current ratings from 6A to 63A, single, double and triple pole.Instantaneous trip type B, C and D.Rated voltage up to 240V AC single phase or 415V AC three phase 50/60Hz.

Full Range of QO Series Miniature Circuit Breaker Breakers

Page 5: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

3

QO Series RCBO

QOvsRCBO Residual Current Circuit Breakerswith Integral Overcurrent Protection

Used in Schneider Electric consumer units, LoadCentre Distribution Boards.Compliance with International Standards: IEC 61009-2-2 and BSEN 61009-1, CE marked.Rated voltage: 240V AC, +10%, -15%.Frequency: 50...60 Hz.Class: AC.Ratings: 10-45 A to 40ºC.Breaking capacity as per IEC 61009: 6 kA.Tripping characteristics: Type C (5-10 In).Tripping time is in compliance with IEE wiring regulations BS7671.Sensitivities: 10 or 30 mA (for protection against direct and indirect contact).ON/OFF Indication:

Trip-free handle through an over-center toggle mechanism that ensure tripping even when the handle is held or locked at the ON position.Overload, short circuit, and earth fault currects are indicated by location of the handle in the OFF position.

Push-to-test Function:A Yellow push-test button “T” is positioned on the front of the device for testing that product is operationalThe smallest operating voltage for the test button: 200V AC (0.85 Un)

Connection:Phase in: plug-on tyepPhase & Neutral out: 1 to 16mm2 flexible or rigid cable (tightening torque 2 N.m)

Catalogue Number

Single Pole

QO110vs6RCBO10QO160vs6RCBO10QO120vs6RCBO10QO132vs6RCBO10QO140vs6RCBO10QO145vs6RCBO10

QO110vs6RCBO30QO160vs6RCBO30QO120vs6RCBO30QO132vs6RCBO30QO140vs6RCBO30QO145vs6RCBO30

101010101010

303030303030

101620324045

101620324045

Sensitivity

mA

Rated Current

A

-

-

-

-

--

QO132vs6RCBO30

Page 6: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

4

QO Series RCBO

QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection

Rated voltage of 220V to 240V AC, 50/60Hz, operating voltage: 50V 250V AC, 50/60Hz.Used in Schneider Electric Consumer Units, LoadCentre Distribution Boards and can be retrofitted to existing installations.Compliance with International Standards : Certfiied to IEC 60898 and IEC 61009, 10kA at 240V AC, 50/60Hz, CE market.ON/OFF Indication: ON/OFF marketings are on the face of the circuit breaker along with the international I/O markings.Handle Operation: Trip-free handle through an over-centre toggle mechanism that ensures tripping even when the handle is held or locked in the ON position.Trip Indication: Indication of a tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position. Indication of a tripped circuit breaker on residual current ground fault is by location of the handle in an intermediate position.Push-to-test Function: A push-to-test button is positioned on the front of the device for testing the residual current electronic trip circuit and mechanism tripping interface.Thermal Trip Element: Thermal trip elements are factory calibrated at 30ºC ambient temperature.Instantaneous trip level:- Type B: (3-5In) Overcurrent protection for sensitive equipment- Type C: (5-10In) Overcurrent protection for all application typesClass: ACResidual Current Protection: Residual ground-fault trip currents are factory set at 10mA, 30mA or 100mA.Trip Mechanism:

Loss of neutral Protection: Device will trip on loss of neutral and is sensitive to both AC and pulsat-ing DC fault current. Device will trip on voltage between neutral and earth greater than 50V AC.Protection against reversed polarity (Phase and Neutral)Protection against nuisance tripping (compliance with IEC 61543 for EMC)

Mounting: Plug-on connection.

-

--

QOE120C03

Page 7: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

5

QO Series RCBO

QOE QWIK-GARD Residual Current Circuit Breakerswith Integral Overcurrent Protection

QOE132C03

Catalogue Number

Single Pole

Maximum Earth FaultLoop Impedance Zs

OHMs at 50V AC (RCCB)

Short Circuit Capacity (Icn) : 10000A

5 Seconds 0.4 Seconds

QOE106B01QOE110B01QOE116B01QOE120B01QOE132B01

QOE106B03QOE110B03QOE116B03QOE120B03QOE132B03

Type B Instantaneous Trip (3In to 5In)1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

575575575575575

575575575575575

50005000500050005000

16671667166716671667

50005000500050005000

16671667166716671667

500500500500500

500500500500500

610162032

610162032

1010101010

3030303030

QOE106C01QOE110C01QOE116C01QOE120C01QOE132C01

QOE106C03QOE110C03QOE116C03QOE120C03QOE132C03

QOE106C10QOE110C10QOE116C10QOE120C10QOE132C10

Type C Instantaneous Trip (5In to 10In)1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

1 - 161 - 161 - 161 - 161 - 16

575575575575575

575575575575575

575575575575575

50005000500050005000

16671667166716671667

500500500500500

50005000500050005000

16671667166716671667

500500500500500

500500500500500

500500500500500

500500500500500

610162032

610162032

610162032

1010101010

3030303030

100100100100100

RatedCurrent

A

TerminalCapacityLoad L&N

mm2

Pigtail Wire ConnectionColor & Length

EarthYellow & Green

mm

NeutralBluemm

ResidualTrippingCurrent

mA

Page 8: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

6

QO Series Miniature Circuit Breakers

QOvs Miniature Circuit Breaker

QO132VSC6 QO132VSC10

QO110VSC10QO116VSC10QO120VSC10 QO125VSC10QO132VSC10QO140VSC10QO150VSC10QO163VSC10

Type C Instantaneous Trip (5In to 10In)1016202532405063

1 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

Short Circuit Capacity (Icn) : 10000ARated Current

A

Teminal Capacity

mm2

QO210VSC10QO216VSC10QO220VSC10 QO225VSC10QO232VSC10QO240VSC10QO250VSC10QO263VSC10

QO310VSC10QO316VSC10QO320VSC10 QO325VSC10QO332VSC10QO340VSC10QO350VSC10QO363VSC10

Catalogue Number

Single Pole Double Pole Triple Pole

QO110VSC6QO116VSC6QO120VSC6 QO125VSC6QO132VSC6QO140VSC6QO150VSC6QO163VSC6

Type C Instantaneous Trip (5In to 10In)1016202532405063

1 - 251 - 251 - 251 - 25

2.5 - 352.5 - 352.5 - 352.5 - 35

Short Circuit Capacity (Icn) : 6000ARated Current

A

Teminal Capacity

mm2

QO210VSC6QO216VSC6QO220VSC6 QO225VSC6QO232VSC6QO240VSC6QO250VSC6QO263VSC6

QO310VSC6QO316VSC6QO320VSC6 QO325VSC6QO332VSC6QO340VSC6QO350VSC6QO363VSC6

Black in color.Instantaneous trip level type C.Indication of tripped circuit breaker on overload or short circuit is by location of the handle in the OFF position & trip status window.

BS EN 60898, IEC 898 - Miniature Circuit BreakerBS EN 60947-3 : 1992Additional safety requirements for Disconnectors and Switch Disconnectors as referred to in BS 7671.

In compliance with specifications:

Catalogue Number

Single Pole Double Pole Triple Pole

QO232VSC10

QO332VSC10

Page 9: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

7

QO Series Miniature Circuit Breakers

QOvs Miniature Circuit Breaker

Technical data

Main characteristics QOvs 6 kA QOvs 10 kA

Insulation voltage (Ui) 500 V ACOperating voltage (Ue) 240/415 V ACRated impulse withstand voltage (Uimp) 4 kV according to

IEC 60898-1Reference temperature 40°COperating frequency 50/60 HzPollution degree 3Magnetic tripping Curve C 5 to 10 In b b

According to IEC/EN 60898-1

Limitation class 3Rated breaking capacity

(Icn)

6000 A 10000 A

Service breaking capacity (Ics) 100 % Icn 75 % Icn

Additional characteristics

Degree of protection

(IEC 60529)

Device only IP20Device in modular enclosure

IP40Insulation classe II

Endurance (O-C) Electrical 4000 cyclesMechanical 20,000 cycles

Operating temperature -5°C to +60°CStorage temperature -40°C to +85°CTropicalization (IEC 60068-1) Treatment 2 (relative humidity

95 % to 55°C)

Dimensions (mm)

DB

4045

41

Weight (g)

Circuit-breaker

Type QOvs

1P 1042P 2083P 312

Circuit-breaker Type Number of poles A B C C' D E

QOvs 1P 78.3 18.7 58.8 51.4 81 86.3

2P 78.3 37.4 58.8 51.4 81 86.3

3P 78.3 56.1 58.8 51.4 81 86.3

1P, 240 V AC2P, 240/415 V AC3P, 240/415 V AC

Page 10: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

8

Full Range of Miniature Circuit Breaker Boards

LoadCentre Distribution Boards with Finger Safe Protection

Specifications

Finger safe design for plug on - main busbar to maximize safety (live part have been totally insulated).Built-in with 4 pole main switch for complete isolation (TPN Type).Quick and easy to install.Accepts 1, 2 & 3 pole Plug-on circuit breakers and RCBOs.Range of incoming devices, including 4 pole.Brass neutral and earth terminal bars for every single pole outgoing way.Plenty of cable space, with knock-outs provid-ed at top and bottom.

Used in offices, banks, IT buildings, hotels and commercial premises.Bluish white color epoxy powder paint. Zinc coated corrosion resistant steel enclosure.Rated voltage up to 415V AC three phase.Main switch comply with BS EN 60439-3. Enclosure protection to BS EN 60529 IP41 (on request for higher IP rating).Comply with BSEN 60439 & IEC 60439.

Finger Safe

Page 11: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

9

LoadCentre Distribution Boards

Rated Current 100A

CatalogueNumber

No. of Ways Dimensions

Heightmm

Widthmm

Depthmm

SQDLC104-100SQDLC106-100SQDLC108-100SQDLC110-100SQDLC112-100SQDLC114-100SQDLC116-100SQDLC118-100SQDLC120-100

LoadCentre TPN Type (Installed with 100A TPN Main Switch)

SQDLC204-100SQDLC206-100SQDLC208-100SQDLC210-100SQDLC212-100SQDLC214-100SQDLC216-100SQDLC218-100SQDLC220-100

468101214161820

Main isolator

SQDLC112-100

SAFE

453510567624681738795852909

380380380380380380380380380

121121121121121121121121121

453510567624681738795852909

380380380380380380380380380

121121121121121121121121121

For installation of Circuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection

LoadCentre Lug Type (For direct connection w/o Main Switch)

468101214161820

Page 12: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

10

LoadCentre Distribution Boards

Rated Current 200A

CatalogueNumber

No. of Ways Dimensions

Heightmm

Widthmm

Depthmm

SQDLC104-200SQDLC106-200SQDLC108-200SQDLC110-200SQDLC112-200SQDLC114-200SQDLC116-200SQDLC118-200SQDLC120-200

LoadCentre TPN Type (Installed with 200A TPN Main Switch)468101214161820

SQDLC204-200SQDLC206-200SQDLC208-200SQDLC210-200SQDLC212-200SQDLC214-200SQDLC216-200SQDLC218-200SQDLC220-200

LoadCentre Lug Type (For direct connection w/o Main Switch)468101214161820

For installation of Circuit Breaker orResidual CurrentCircuit Breakerwith IntegralOvercurrent Protection

SAFE

SQDLC112-200

5676246817387958529099661023

380380380380380380380380380

121121121121121121121121121

5676246817387958529099661023

380380380380380380380380380

121121121121121121121121121

Main isolator

Page 13: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

11

CLASSIC Metal Consumer Units with Finger Safe Protection

Specifications

Catalogue Number No. of Ways Dimensions

Heightmm

Widthmm

Depthmm

SDCS14SDCS16SDCS110SDCS114SDCS118

100A Rated With Space for Incoming Device46101418

206206206206206

200238315391517

9898989898

Weight

kg

1.91.92.53.14

Catalogue Number Description Dimensions

Heightmm

Widthmm

Depthmm

QO2100MBXPlug-on Incoming Device

100A double pole main switch 80 40 85

Weight

kg

0.28

Terminal Capacity

mm2

35

Finger safe design for plug on main busbar to maximize safety.Used in apartments. IT buildings, banks, hotels and commercial premises.White color, epoxy power paint.Zinc coated corrosion resistant steel enclosure.Rated voltage up to 240V AC single phase.Comply with BS EN 60439 & IEC 60439.Plug-on main switch complies with BS EN 60947-3 : 1992.Plug-on circuit breakers provide positive connection to the busbar in one quick operation, saving up to 50% on wiring and connection time.

SAFE

Rated Current 100A

SDCS14

Main Isolator

Circuit Breaker or RCBO

Finger Safe Main Busbar

Page 14: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

12

Certificates

Miniature Circuit Breaker

Page 15: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

Certificates

Consumer unit / LoadCentre

13

Page 16: Plug on Type MCBs & Distribution Boards - Schneider … · Plug on Type MCBs & Distribution Boards ... the circuit breaker handle is held or locked in ... (for protection against

Schneider Electric (HK) Ltd. 13th Floor, East Wing, Warwick House, Taikoo Place,979 King’s Road, Quarry Bay, Hong KongTel: (852)2565 0621 Fax: (852)2811 1029Customer Care Centre: (852)2579 9699www.schneider-electric.com/hk

Macau Branch Office:Alameda Dr Carlos D’Assumpcao 180,Tong Nam Ah Central Comercio 13G, 13H & 13I, MacauTel : (853)2871 7488Fax: (853)2871 7499

SEHK/SQD/008 05/2012

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

Certificates