pleasantly di˜ erent - terumo-europe.com

6
Pleasantly different

Upload: others

Post on 01-May-2022

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Pleasantly di˜ erent - terumo-europe.com

Visit www.terumo-diabetes.com

Pleasantly di� erent

Page 2: Pleasantly di˜ erent - terumo-europe.com

HELPFUL GUIDANCE

The display shows helpful on-screen instructions and patient guidance:

1 Easy to navigate with text and illustrations.

2 Easy to read with universal font.

3 Easy to understand error messages and suggestions to correct the error.

PATIENT SUPPORT

Menu supports patient by:

Displaying a smiley for blood glucose levels in the target range. Alerting when the blood glucose level is outside the target range.

Post-Meal marking helps patient by:

Managing glucose levels related to meals. Adjusting target ranges related to pre- and post-meal values.

Display

The acceptable ranges of blood glucose can be fully customized.

Alternate reverse display at intervals of 1 sec

Low HighBlood glucose level

Beep, Beep, Beep (3 x)

Beep, Beep, Beep, Beep, Beep (5 x)

Medium

Post-Meal marking helps patient by:

Managing glucose levels related to meals.

Adjusting target ranges related to pre- and post-meal values.

Alternate reverse display at intervals of 1 sec

1 2 3

Functional design supporting patients

Page 3: Pleasantly di˜ erent - terumo-europe.com

EXCEPTIONAL TEST TIP

Individually packed Test TIPs, which are protected from environmental in� uence, like humidity and dirt.

Easy to attach Test TIP.

The nozzle of the Test TIP allows easy blood sampling.

Clean disposal with the ejector lever.

No coding.

ERGONOMIC DESIGN

Fit-curve design

Fits to a variety of patient’s holding styles. Allows to measure when placed on the table.

Page 4: Pleasantly di˜ erent - terumo-europe.com

SIMPLE DATA TRANSFER

Wireless data transfer via Near Field Communication (NFC) technology

Placing the meter on top of the NFC reader unit allows records to be transferred directly to a computer.

THE COMPLETE SYSTEM

The blood glucose meter that combines accuracy and ease of use

MEDISAFE FITBlood Glucose Meter

The Medisafe FIT blood glucose meter is a high quality medical device, which combines reliability and ease of use.The design of the meter and single-packed Test TIPs is pleasantly di� erent, meetingthe patient's needs.

TERUMO FINETOUCHLancing Device

The Terumo Finetouch lancing device provides 5 adjustable penetration depths. With the functional design of the lancet, accidental needle stick injuries can be prevented. The majority of patients in a survey perceived the lancet as less painful.2

Requires NFC Reader / Writer

1 Terumo Corporation has launched Nanopass 34G in September 2012.2 Kordonouri O. et al., 2007, Diabetologie & Sto� wechsel; 2:S72.3 Patented technology.4 Asakura T., Seino H., 2013, Jpn J Med Pharm Sci 69(1):137-146. & Asakura T., 2013, Jpn J Med Pharm Sci 69(1):147-155.5 Based on research by Terumo Corporation in May 2017.

NANOPASSPen Needle

The Nanopass pen needles with the unique asymmetric bevel3 cut are designed to reduce pain4 during insulin injection. Nanopass 32.5G o� ers a pen needle for every type of patients. For the more sensible patients choose Nanopass 34G, the world's thinnest double tapered pen needle.5

Wor

ld's First 1

Page 5: Pleasantly di˜ erent - terumo-europe.com

Visit www.terumo-diabetes.com

IN COMPLIANCE WITH EN ISO 15197:2015 ACCURACY REQUIREMENTS

Complies fully with EN ISO 15197:20151,2 accuracy requirements in the laboratory and at the user performance.3

DUAL RS™ MEASUREMENT TECHNOLOGY

Medisafe FIT with Dual RS™ technology ensureshigh analytical performance.

1 Reliable within hematocrit value 20-60%

2 Not a� ected by dissolved oxygen or maltose

3 Recognition of insu� cient blood sample

1 ISO (International Organization for Standardization). EN ISO 15197:2015 In vitro diagnostic test systems – Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013), Geneva, Switzerland, 2015

2 EN ISO 15197:2015 system accuracy performance criteria• performed by trained operators:

- 95% of the glucose values shall fall within either ±15 mg/dL of the comparison measurement values at glucose concentrations <100 mg/dL or within ± 15% at glucose concentrations ≥100 mg/dL

- 99 % of the glucose values shall fall within zones A and B of the Consensus Error Grid (CEG) for type 1 diabetes

• performed by lay persons: - 95% of the glucose values shall fall within either ±15 mg/dL of the comparison

measurement values at glucose concentrations <100 mg/dL or within ± 15% at glucose concentrations ≥100 mg/dL

3 Freckmann G. et al. Analytical and User Performance Evaluation of a Blood Glucose Monitoring System following ISO 15197:2013FREC1454D – Poster Session; 6th November 2014; Diabetes Technology Meeting 2014, Bethesda, Maryland, USA, 6th – 8th November 2014.

Technology that provides high accuracy

Colo

ur in

tens

ity

Dual RS™ measurement technology usestwo beams for measuring separatelyhematocrit and glucose.

Wavelength (nm)

Hematocrit reading Reagent colour intensity reading

Blood density (for hematocrit measurement)

Reagent colour intensity (for glucose measurement)

(Con

cept

illu

stra

tion)

System accuracy evaluation

Med

isaf

e Fi

t (m

g/dL

)

Cobas Integra® 400 plus (Hexokinase) (mg/dL)

- 100

- 80

- 60

- 40

- 20

0

20

40

60

80

100

0 50 100 150 200 250 300 350 400 450 500 550

3 lot numbers

100% of the results with glucose concentration <100 mg/dL3 and

99.8% of the results with glucose concentration ≥100 mg/dL are within the accuracy limits3

User performance evaluation

Med

isaf

e Fi

t (m

g/dL

)

YSI 2300 Stat Plus™ (Glucose oxidase) (mg/dL)

- 100

- 80

- 60

- 40

- 20

0

20

40

60

80

100

0 50 100 150 200 250 300 350 400 450 500 550

1 lot number

100% of the results measured by patients arewithin the accuracy limits3

E D C B A

B

C

D

3 lots numbers

A

Consensus Error Grid (CEG)

Med

isaf

e Fi

t (m

g/dL

)

Cobas Integra® 400 plus (Hexokinase) (mg/dL)

0

50

100

150

200

250

300

350

400

450

500

550

0 50 100 150 200 250 300 350 400 450 500 550

100% of the results are within CEG zone A3

Page 6: Pleasantly di˜ erent - terumo-europe.com

DI 1

19GB

-091

4FK-

III(1

1.17

)E

Terumo Deutschland GmbH +49 6196 80 230

Terumo Deutschland GmbH ZweigniederlassungSwitzerland+41 56 419 10 10

Terumo Corporation+81 3 3374 8111

Terumo Europe NV+32 16 38 12 11

Terumo Italia S.r.l.+39 06 94 80 28 00

Terumo Middle East FZE +971 4 292 0200

www.terumo-europe.com® Registered TrademarkPublished by Terumo Europe NV

The blood glucose meter that combines accuracy and ease of use

Product Name Product Code Pieces

MEDISAFE FIT Control Solution

Low MS*CSL02

1Medium MS*CSM02

High MS*CSH02

* Please contact your local Terumo o� ce.

Visit www.terumo-diabetes.com

Starter KitMEDISAFE FIT Blood Glucose Monitoring System

Accessory

Product Name Product Code Pieces

MEDISAFE FIT Blood Glucose Meter

mg/dL or mmol/L country related* 1

MEDISAFE FIT Blood Glucose Test TIP MS*FC025C 25

TERUMO FINETOUCH Lancing Device MS*GN02C 1

TERUMO FINETOUCH Lancet MS*GN4525C 25