performence check for building designed with nbc, is

72
Check for Performance of Building Designed with NBC and IS Codes

Upload: aditya2053

Post on 05-Apr-2018

223 views

Category:

Documents


1 download

TRANSCRIPT

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 1/72

Check for Performance of Building

Designed with NBC and IS Codes

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 2/72

TASKS

• Study of IAEE Manual( Guidelines for EarthquakeResistant Non-Engineered Construction)

• Comments on Existing NBC 205

Nonlinear static analysis of Building designed withNBC 205,105 and IS 1893,2002 for life safety

criteria

• Recommendations for further work

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 3/72

Methodology Select Building

Code

NBC 205 NBC 105/IS 1893,2002

Prepare Analysis

Building Model

Analyze building and design as

per selected code

Select Design load level and Load

factors from Selected code

Produce Beam and column Reinforcement detailing

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 4/72

Methodology

Determine, Capacity

Curve, Demand Curve

and Performance point

Development of Pushover

hinges for Beam and column

Nonlinear Static ,Pushoveranalysis

Select Codal Response spectra and

evaluate Spectra parameter Ca, Cv

Repeat the whole process

till satisfaction of Life

safety criteria

Life

safety

Criteria?

Does not

Meet

Increase design force level,

Modification in codal

provision

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 5/72

Methodology

Determine, Capacity

Curve, Demand Curve

and Performance point

Repeat Nonlinear Static,Pushover analysis

Upgrade Codal Response spectra and

evaluate Spectra parameter Ca, Cv

Repeat the whole

process till satisfaction

of Life safety criteria

Need to upgrade

performance

level?

Does notMeet

Increase design force

level,

Modification in codal

provision

Life

safety

Criteria

Recommend New Design Response spectrum

curve and load factors

Use this spectra for

design of representative

nos of models

Compile detailing outputs

And recommend in NBC

205

No Use Codal spectra

for design of 

representative nosof models

Compile detailing

outputs

And recommend

in NBC 205

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 6/72

Nonlinear Static Pushover analysis

Push-over Curve

Load Vs. DeflectionVb

UN

UN F

Vb

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 7/72

Analysis Building Model

4.5 m

3.5 m

3.35 m

5X 3 Bays

Vertical Loadings are confirming to

NBC 102, 103

Steel :Fe 415

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 8/72

Performance check for Building

Detailed with NBC 205

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 9/72

Beam Detailing , NBC 205

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 10/72

Beam Detailing , NBC 205

Beam Size: 230 X 325

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 11/72

Column Detailing, NBC 205

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 12/72

NBC 205, Column Detailing

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 13/72

Pushover Hinges; beam moment

A

B

C

D

E

M/My

Curvature/SF

Yield Moment, My : From Analysis of section with Material partial factor of safety = 1

Steel ultimate strength = 1.25*steel yield strength

Hysteresis Type: Isotropic 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 14/72

Column Hinge

• Column hinge is based up on Interaction diagram of 

column

• Removing partial factor of safety for concrete and steel

Ultimate strength of steel = 1.25*yield strength{ Fema356}

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 15/72

Selection of Response Spectra

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 16/72

300 YRS Return Period PGA Distributions

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 17/72

Response Spectra Parameter: Ca, Cv

Ground Acceleration, Ca = 0.32gStructural Response ,Acceleration at 1 sec, Cv =0.4g

0.32 g

0.32 g*2.5 =0.8g

0.32 g*2.5/2 =0.4 g

NBC Fits Response spectra with IS

Response spectra:

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 18/72

Pushover Analysis Output, PUSH X

 Just before Structural instability:

Total nos of elastic hinge: 198 Nos

Total Immediate occupancy Hinge: 114 Nos

Total life safety hinge: 6 nos

Total Collapse prevention hinge: 14 Nos

Column Need to be strong for avoiding Collapse prevention hinge in

column

IO LS

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 19/72

ATC 40, Global Building Acceptability

Limits

0.33*0.08 =0.0264

0.01*10050 =100.5 mm 100.5mm to 201 mm

Top Story Displacementlimits

265.32 mm

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 20/72

ATC 40 Capacity Spectrum;

Earthquake: 300 Years of Return period

Earthquake: 300 years Return period 

Target base shear: 923.544 KN 

Target Displacement: 127.27 mm

Corresponding Inter story Drift: 127.27/(10050)=0.013 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 300 Years Return period 

Push X

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 21/72

PUSHX, Capacity Curve and Elastic Response

L

S

L

C

P

LE

I

D

I

0

L Ductility Demand > Available Ductility 

=> For Higher earthquake there will be

no ductility 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 22/72

Pushover Analysis Output, PUSH Y

 Just before Structural instability:

Total nos of elastic hinge: 204 Nos

Total Immediate occupancy Hinge: 24 Nos

Total life safety hinge: 2 nos

Total Collapse prevention hinge: 30 Nos

Column Need to be strong for avoiding Collapse prevention

hinge

IO LS

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 23/72

ATC 40, Capacity Spectrum

Earthquake: 300 Years of Return period

Earthquake: 300 years Return period 

Target base shear: 929.51 KN 

Target Displacement: 125.561 mm

Corresponding Inter story Drift: 125.561/(10050)=0.0125 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 300 Years Return period 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 24/72

PUSHY Capacity Curve and

Elastic response

L

S

L

C

P

LEI

D

I

0

LDuctility Demand > Available Ductility 

=> For Higher earthquake there will be

no ductility 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 25/72

Check For NBC205 Designed Building

For 500 YRS RP Earthquake

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 26/72

26

500 YRS RP Ground Acceleration

Distributions

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 27/72

27

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 28/72

500 Yrs Response Spectra Parameter: Ca, Cv

Ground Acceleration, Ca = 0.36gStructural Response, Acceleration at 1 sec, Cv

=0.45g

0.36 g

0.36 g*2.5 =0.9g

0.36 g*2.5/2 =0.45g

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 29/72

ATC40 Capacity Spectra for 500 yrs return period

Earthquake

Capacity Curve and Demand curve do not meet:

This is due to formation of collapse prevention

hinges in columns and high seismic loading both

PUSH X

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 30/72

ATC40 Capacity Spectra for 500 yrs return

period Earthquake

PUSH X

Capacity Curve and Demand curve do not meet:

This is due to formation of collapse prevention

hinges in columns and high seismic loading both

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 31/72

Check for Performance of NBC105

Designed Building :

300 YRS RP Earthquake ResponseSpectra

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 32/72

NBC 105, Seismic Load

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 33/72

NBC 105, Seismic Force Distribution

54.55 KN

218.21 KN

304.03 KN

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 34/72

NBC105;

End Beam

Design

Output 

Beam:

230 X 350 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 35/72

Column Design Output, NBC105

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 36/72

Response Spectra Parameter: Ca, Cv For 300 YRS RP

Ground Acceleration, Ca = 0.32g

Structural Response ,Acceleration at 1 sec, Cv

=0.4g

0.32 g

0.32 g*2.5 =0.8g

0.32 g*2.5/2 =0.4 g

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 37/72

ATC 40, Capacity Spectrum

Earthquake: 300 Years of Return period

PUSH X Output 

Earthquake: 300 years Return period 

Target base shear: 1314.596 KN 

Target Displacement: 92 mm

Corresponding Inter story Drift: 92/(10050)=0.01 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 300 Years Return period 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 38/72

Pushover Analysis Output, PUSH X

 Just before Structural instability:

Total nos of elastic hinge: 158 Nos

Total Immediate occupancy Hinge: 124 Nos

Total life safety hinge: 68 nosTotal life safety to collapse prevention hinge: 18 nos

Total Unstable hinge: 4 Nos

Column Need to be strong for avoiding Collapse prevention

hinge

IO LS

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 39/72

Capacity Curve and Elastic Response

L

S

L

E

I

D

I

0

L

Ductility Demand> Available Ductility=> For Higher earthquake there will be no

ductility

Same as recommended in

Seismic hazard mapping and

risk assessment for Nepal

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 40/72

ATC 40, Capacity Spectrum

Earthquake: 300 Years of Return period

Earthquake: 300 years Return period 

Target base shear: 1315.983 KN 

Target Displacement: 91 mm

Corresponding Inter story Drift: 91/(10050)=0.01 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 300 Years Return period 

PUSH Y Output 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 41/72

Capacity Curve and Elastic Response

L

S

L

E

I

D

I

0

L

Ductility Demand> Available Ductility

=> For Higher earthquake there will be no

ductility

Same as recommended in

Seismic hazard mapping and

risk assessment for Nepal

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 42/72

Check For NBC 105 Designed Building

For 500 YRS RP Earthquake

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 43/72

500 Yrs Response Spectra Parameter: Ca, Cv

Ground Acceleration, Ca = 0.36gStructural Response, Acceleration at 1 sec, Cv

=0.45g

0.36 g

0.36 g*2.5 =0.9g

0.36 g*2.5/2 =0.45g

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 44/72

ATC40 Capacity Spectra for 500 yrs return

period Earthquake

PUSH X

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 45/72

ATC40 Capacity Spectra for 500 yrs return

period Earthquake

PUSH Y

Performance point does not meet in Y direction

Buildings designed for 300 YRS RP is Not safe in 500 YRS RP Earthquake

Demand curve above capacity curve indicates need of increase in design force level 

Performance point 

Not available

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 46/72

Check For Modified NBC 105 DesignedBuilding For 500 YRS RP Earthquake

Proposed Modification in NBC 105

Considers Basic seismic Coefficient of 

0.09 instead of 0.08

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 47/72

Proposed Response spectrum: 10% in 50 years( 500 YRS RP)

Short period spectral acceleration: 0.9 g

Ground acceleration: 0.36 g

1 Sec , Spectral acceleration : 0.45 g

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 48/72

500 Yrs Response Spectra Parameter: Ca, Cv

Ground Acceleration, Ca = 0.36gStructural Response, Acceleration at 1 sec, Cv

=0.45g

0.36 g

0.36 g*2.5 =0.9g

0.36 g*2.5/2 =0.45g

C= Ct*Z*I*K= 0.09

Load factors are remains

as it is

0.045/T

0.09/T0.09

0.036/T

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 49/72

Seismic Load

NBC 105, Modified Response spectra

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 50/72

Seismic Load Distribution

61.37 KN

245.48 KN

342.04 KN

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 51/72

Beam Design output

Beam 230X350

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 52/72

Column Design Output

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 53/72

ATC40 Capacity Spectra for 500 yrs return period

Earthquake

Earthquake: 500 years Return period 

Target base shear: 1636.357 KN 

Target Displacement: 103.403 mm

Corresponding Inter story Drift: 103.403/(10050)=0.01 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 500 Years Return period 

PUSH X

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 54/72

PUSH X , Output

 Just before Structural instability:

Total nos of elastic hinge: 154 Nos

Total Immediate occupancy Hinge: 124 Nos

Total life safety hinge: 74 nos

Total life safety to collapse prevention hinge: 10 nos

Total Unstable hinge: 10 Nos

Column Need to be strong for avoiding Collapse prevention

hinge

IO LS

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 55/72

Capacity Curve and Elastic Response

L

S

L

E

I

D

I

0

L

Ductility Demand> Available Ductility

=> For Higher earthquake there will be no

ductility

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 56/72

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 57/72

PUSH X , Output

 Just before Structural instability:

Total nos of elastic hinge: 168 Nos

Total Immediate occupancy Hinge: 106 Nos

Total life safety hinge: 74 nos

Total life safety to collapse prevention hinge: 14 nos

Total Unstable hinge: 10 Nos

Column Need to be strong for avoiding Collapse prevention

hinge

IO LS

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 58/72

Building with Additional , SCWB Satisfying condition

500 YRS Return period 1000 YRS Return period

300 YRS Return Period

Strong column Weak beam condition

improves linear ductility

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 59/72

Check for performance level for IS

1893,2002 Designed Building

500 YRS RP Response Spectra

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 60/72

500 Years Return period

IS 1893, 2002, Response spectra

0.36 g

0.45 g

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 61/72

Response Spectra Parameter: Ca, Cv

Ca =0.36Cv=0.45

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 62/72

Evaluation of Seismic Static Load:• Seismic wt, W =Wt of the

building due to DL+0.25LL

• Base shear = Ah* W

• W= W1+W2+W3

• Z = zone factor

• I =Importance factor

• R = response reduction factor

• Sa/g = Spectral acceleration

coefficients

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 63/72

S i i F Di t ib ti

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 64/72

Seismic Force Distribution

61.4 KN

245.5 KN

342.0 KN

ATC40 Capacity Spectra for 500 yrs return

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 65/72

ATC40 Capacity Spectra for 500 yrs return

period Earthquake

PUSH X

Earthquake: 500 years Return period 

Target base shear: 1973.06 KN 

Target Displacement: 104.0 mm

Corresponding Inter story Drift: 104.0/(10050)=0.01 < 0.02( Damage control,0.01 to 0.02)

Life Safety Limit is ensured for 500 Years Return period 

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 66/72

C it C d El ti R

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 67/72

Capacity Curve and Elastic Response

Ductility Demand is very close to Available

Ductility but still lacking in ductility

Conclusion

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 68/72

Conclusion

• Building Detailed with NBC 205

 – Meets life safety criterion for 300

 – No global linear ductility for higher earthquake

 – Failure in 500 Yrs RP Earthquake

Conclusion

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 69/72

Conclusion

• Building Detailed with NBC 105

 – Meets life safety criterion for 300

 – No global linear ductility for higher earthquake

 – Failure in 500 Yrs RP Earthquake

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 70/72

Conclusion

• Building Designed with Modified NBC 105 Response

spectra

 – Life safety criteria meets for 500 YRS RP Earthquake

 – Needs more global ductility for ensuring collapse

prevention for higher earthquake

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 71/72

Recommendations

Replace 300 Yrs Response spectra with 500 yrsResponse spectra in NBC 105

• Add additional clause for strong column weak beamfor ensuring collapse prevention in higher earthquake

• Use modified NBC 105 for the analysis of Samplebuildings belongs to NBC 205

• Develop summary of detailing and replace old Existingdetailing

8/2/2019 Performence Check for Building Designed With NBC, Is

http://slidepdf.com/reader/full/performence-check-for-building-designed-with-nbc-is 72/72

THANK YOU