Ensure Quality Milk and Dairy ProductsFrom Farm to Fridge Using FT-NIRDr. Florian Eigenmann, Business Development Manager DairyBruker Optics Inc. (USA)6/19/2013 11:00 AM EST
September 12, 2013
QC from raw milk to dairy products with one instrument
12.09.2013
2
MPA fully equipped
Each customer buys exactly the instrument that matches his application. There is no need to purchase anything that is not wanted or needed.
MPA basic configuration
Custom made Instrument:
Fiber Optic Probes
Sample Compartment
Reflection withsmall Spinner
Reflection withlarge spinner
Maximum Flexibility with one Analyzer:
12.09.2013
3
Inte
ract
ion
X-Ray
Nuclear Excita-
tion
SpinOrientation in
Magnetic Fields
Molecule RotationMolecule VibrationValence Electron
Excitation
Inner Elec-tron
Excita-tion
-Radiation
Radio WaveMikro WaveInfra Red
NMRESRFIRMIRV I S
NIR
UV
Reg
ion
10-310-210-11101102103104105106107108
101110-110-210-310-410-510-610-710-810-910-10
Wavenumber(cm-1)
Wavelength(m)
Infrared Light and especially FT-NIR
Principle of FT-NIR
12.09.2013
4
FT-NIR spectroscopy in quality controlallows the use of robust cells, 1-10 mm
200040006000800010000
Wellenzahl / cm-1
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Ab
sorb
anz
(CH)3(CH)
MIR & NIR (d = 25 µm)
NIR (d = 1 mm)
2(CH)
Milk: 1 mm
Olive Oil: 8 mm
The exceptional performance of the instrument ensures a smooth calibration transfer not only to other MPA instruments but also to the MATRIX process spectrometers.
Calibration Transfer
12.09.2013
5
Principle of an homogenizer
To get reproducible measurement results for raw milk it is an absolute must to use an homogenizer first to stabilize the sample
9
Liquids Sampling System (LSM) with MPA
10
12.09.2013
6
Liquids Sampling System (LSM)
Inlet Valve
Homogenizer Valve
Peristaltic PumpHigh Pressure Pump
11
USDA data: external validation
12
12.09.2013
7
Fat in Raw Milk with homogenizer
05/2013
MPA + LSM are the perfect combination: DAIRY ANALYZER
• The new Dairy Analyzer is not a MilkoScan – it is more!
• The Dairy Analyzer measures more types of liquid products even with higher viscosity (peristaltic pump)
• More parameters for raw milk under investigation, e.g.
• Milk fat composition or quality, i.e. fatty acids
• Long, medium and short chain length
• Saturated and un-saturated• Trans fatty acid
• Freezing point
14
12.09.2013
8
Dairy Analyzer
Applications
• Raw, skim, processed and condensed milk
• Whey and whey concentrate• Cream and whey• Whey protein and lactose concentrates• Milk, cream and whey powder• Cheese (soft, hard, sliced, processed,
white cheese, curd, etc...)• Butter (salted, un-salted)• Yogurt, desserts• Milk drinks and ice cream (melted)
15
raw milk R² RMSECV
Fat 99.9 0.025
Protein 98.5 0.035Total Solids(TS) 98.4 0.057
Lactose 94.2 0.045
MPA + LSM – new calibrations in milk...
16September 12,
R² RMSECVFreezing Point 85.23 0.025
LCFA* 94.45 0.064MCFA* 96.64 0.081SCFA* 98.05 0.015Casein 99.73 0.017
Mono FA* 79.22 1.38Saturated FA* 84.65 1.72
Unsaturated FA* 84.65 1.72TFA 74.50 0.01Urea 70.70 3.60
* FA = Fatty Acids* LC = Long Chain* MC = Medium Chain* SC = Short Chain
12.09.2013
9
New Feature for LSMHomogenizer Efficiency Test
• Maintaining Homogenizers is an important task
• FT-NIR can detect mean fat globule size
• This test ensures that LSM homogenizer is working well.
• Common analyzers are based on FT-IR and can’t provide such a test capability
• Homogenizer valve of LSM can be changed easily by customer• Raw milk
• Homogenized raw milk (LSM)• In-sufficient homogenized raw milk,
Homo valve of LSM needs to be changed• UHT Milk (Supermarket), more
homogenized as required for analysis
17
Easy Software GUI O/LAB for Operators
Click 1Click 2
12.09.2013
10
© Copyright Bruker Corporation. All rights reserved.
Innovation with Integrity
Copyright © 2011 Bruker Corporation. All rights reserved. www.bruker.com
Salesmeeting 2012, Pforzheim
Innovation with Integrity
Click
19
Raw Milk
Easy Software GUI O/LAB for Operators
12.09.2013
11
Easy Software GUI O/LAB for Operators
Results:
R2 Range RMSEP
Fat 99.61 0.2 - 8.5 ± 0.14%
Dry Matter 99.01 13.4 - 31.7 ± 0.36%
Other applications with the same analyzer:yoghurt, milk powder, cheese
12.09.2013
12
Trends to large plants, automation
23
>> This are trends towards fast analysis, like infrared analysis
Tango with Touch-Screen Interface
24
12.09.2013
13
Tango with Touch-Screen Interface
25
26
New technology: FT-NIRno drifts over time: rugged and solid
dedicated software GUI
rugged FT-NIR instrumentsapproved calibration transfer
released database, OPUS 7.0DAIRY ANALYZER
TANGO
MATRIX
12.09.2013
14
12.09.2013 27
Network connections and Performance Qualification
28
O/NET, database
12.09.2013
15
Total Cost of Ownership: PROCESS
29
MATRIX-F:
Source inside spectrometer
Detector
12.09.2013
16
Milk online... with fiber optics
Milk and Liquid Milk Analysis using probe
• Transflection probe unique in the market and very suitable for dairy processes to analyze cloudy or turbid samples with high water content
• Sample types are:– Raw and skim milk
– Feed of spray towers even for infant formula (Baby milkpowder)
– Milk drinks
– Fresh cheeses and curds with low total solid content
12.09.2013
17
Spray tower
Fluid bed dryer Sifter
Feed (liquid)
Reflection probeALBEDO
Transflection probe IN271
On-line analysis of Spray Dryer Feed and Milk Powder at Sifter
34
Principle of Transflection
1 mm distance
≊2 mm optical distance
12.09.2013
18
Application fields:cloudy reflecting samples(suspensions, emulsions) like
• fermentation processes• polymer emulsions• milk• cream• …
Transflection Probe
detection of transmitted and reflected light
NEW Q412/A NIR Sensor Head
12.09.2013
19
NEW Q412/A NIR Sensor Head
2x 5 W NIR lamps
working distance: 10 cm
measurement area: 10 mm
protection class: NEMA 4
ambient temperature: max. 60oC
housing: stainless steel (1.4301)
sapphire window
with internal reference
Fibre-coupled probe head for contactless measurements2 pairs of halogen lamps for sample illumination
The MATRIX-F Emission for contactless measurements
12.09.2013
20
Sifter-application
Sifter-application
12.09.2013
21
Sifter-application
Sapphire Window Implementation
12.09.2013
22
Contactless on-line Analysis of Butter with Q412 Emission Head
Process Adaptation – Yogurt
12.09.2013
23
contact your local dairy expert:
45
Houston, TX
Madison, WIFremont, CA
Bruker Methods
Customer Methods
From Raw Milk to Dairy Products
12.09.2013
24
Installation at Konolfingen Switzerland
Installation in coffee creamer factory
12.09.2013
25
Online milk measurements