Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Rental kit as option (POWER ON RENT). PRIME POWER PRP EMERGENCY POWER LTP Voltage Frequency Power factor 1104A-44TG2 Water 1.500 4.400 0,8 209 14,9 / 11,2 96 71 2.285x920x1.500 GSW80P (*) 77,0 (61,6) 80,0 (64,0) 400 50 SU800TPA Water 1.500 3.300 19,9 / 14,9 96 71 2.285x920x1.500 1.119 1103A-33TG2 GSW65P (*) SU600TPA 60,7 (48,6) 63,0 (50,4) 400 50 0,8 209 1.190 Displacement DIESEL ENGINE c.c. CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS WITHOUT PRIOR NOTICE Canopy made in zincted steel profiles with green power coated layer. Cos φ Speed rpm Hz Dimensions (LxWxH) mm Autonomy (75/100% load PRP) h Acoustic pressure at 7m Acoustic power LWA Litres dB(A) Perkins CODE Cooling system kg Volt Three phase Type kVA (kW) kVA (kW) Weight (3ph) Liquid cooling Diesel engine. Control panel protected by lockable door MODEL | GSW65-80Perkins Fuel capacity MODEL Fully bunded / Completly sealed baseframe as option. REF. PC5208_3St.00 IP23 GSW65P GSW80P • Start/stop selector switch with key (Glow plugs preheating function also included). • Emergency stop button installed on canopy side. • Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature. Ouput 71,9 / 79,1 14,0 / 18,7 229 Mechanical 12 UCI224F 10,5 / 14,0 228 H 4.400 4 L Turbo 12 UCI224E H 3.300 3ç L Turbo 53,8 / 59,3 Displacement MANUAL CONTROL PANEL (MCP) ALTERNATOR 3ph c.c. Type Type (%) Insulation Mechanical TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CU Cyliders and disposition l/h Engine governor Volt g/kWh Type Electrical system (DC) Specific consumption PRP MANUAL CONTROL PANEL (MCP) Commands and others Fuel consumption (75/100% load) Engine power PRP / LTP kWm Aspiration n° disp. Protections with shutdown STAMFORD Voltage regulation Mechanical degree protection Class IP23 Electronic (±1,5%) • Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature. • Circuit breaker protection: III poles. • Differential protection. • Genereting set voltage (1 phase). • Generating set current (1 phase). • Hours-counter. Type • Power cables connected to Circuit Breaker (*) Only for non mobile applications, according to COM II regulation. Manual control panel, mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set and sockets, protected through door with lockable handle. Instrumentation (analogue) Protections with alarm REF. PC5208_3St.00 Rev.00 (Ago2010) Pag. 1 of 3

Upload: phungdieu

Post on 03-Jul-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

Internal residential muffler.

Detachable central lifting point.

Complete with engine and battery liquids.

Oil draining facilities.

Baseframe capable to be moved with hand pallet truck.

Rental kit as option (POWER ON RENT).

PRIME POWER PRP

EMERGENCY POWER LTP

Voltage

Frequency

Power factor

1104A-44TG2

Water

1.500

4.400

0,8

209

14,9 / 11,2

96

71

2.285x920x1.500

GSW80P (*)

77,0 (61,6)

80,0 (64,0)

400

50

SU800TPA

Water

1.500

3.300

19,9 / 14,9

96

71

2.285x920x1.500

1.119

1103A-33TG2

GSW65P (*)

SU600TPA

60,7 (48,6)

63,0 (50,4)

400

50

0,8

209

1.190

Displacement

DIESEL ENGINE

c.c.

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Canopy made in zincted steel profiles with green power coated layer.

Cos φ

Speed rpm

Hz

Dimensions (LxWxH) mm

Autonomy (75/100% load PRP) h

Acoustic pressure at 7m

Acoustic power LWA

Litres

dB(A)

Perkins

CODE

Cooling system

kg

Volt

Thre

e p

hase

Type

kVA (kW)

kVA (kW)

Weight (3ph)

Liquid cooling Diesel engine.

Control panel protected by lockable door

MODEL|GSW65-80Perkins

Fuel capacity

MODEL

Fully bunded / Completly sealed baseframe as option.

REF. PC5208_3St.00

IP23

GSW65P GSW80P

• Start/stop selector switch with key (Glow plugs preheating function also included).

• Emergency stop button installed on canopy side.

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

Ouput

71,9 / 79,1

14,0 / 18,7

229

Mechanical

12

UCI224F

10,5 / 14,0

228

H

4.400

4 L

Turbo

12

UCI224E

H

3.300

3ç L

Turbo

53,8 / 59,3

Displacement

MANUAL CONTROL PANEL (MCP)

ALTERNATOR 3ph

c.c.

Type

Type (%)

Insulation

Mechanical

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Cyliders and disposition

l/h

Engine governor

Volt

g/kWh

Type

Electrical system (DC)

Specific consumption PRP

MANUAL CONTROL PANEL (MCP)

Commands and

others

Fuel consumption (75/100% load)

Engine power PRP / LTP kWm

Aspiration

n° disp.

Protections with

shutdown

STAMFORD

Voltage regulation

Mechanical degree protection

Class

IP23

Electronic (±1,5%)

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

• Circuit breaker protection: III poles.

• Differential protection.

• Genereting set voltage (1 phase).

• Generating set current (1 phase).

• Hours-counter.

Type

• Power cables connected to Circuit Breaker

(*) Only for non mobile applications, according to COM II regulation.

Manual control panel,

mounted on the genset and

complete of: analogue

instrumentation, control,

protection of the generating

set and sockets, protected

through door with lockable

handle.

Instrumentation

(analogue)

Protections with

alarm

REF. PC5208_3St.00

Rev.00 (Ago2010) Pag. 1 of 3

Page 2: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

GSW65P GSW80P

GSW65P GSW80P

Protections with

shutdown

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Plinth row for connection from ACP to LTS panel.

AUTOMATIC CONTROL PANEL (AMF)

Automatic control panel

mounted on the genset,

complete with digital control

unit AC03 for monitoring,

control and protection of

the generating set,

protected through door with

lockable handle.

AUTOMATIC CONTROL PANEL (ACP)

Digital

instrumentation

through AC-03

control unit.

AUTOMATIC CONTROL PANEL (AMF)

AUTOMATIC CONTROL PANEL (ACP)TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model)

Digital

instrumentation

through AC03

control unit.

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model)

Commands and

others

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Remote starting availability.

• DC system disconnection switch.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

• Emergency stop button installed on canopy side.

Protections with

alarm

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage

• Power cables connected to Circuit BreakerOuput

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

• Circuit breaker protection:III poles.

• Differential protection by means of the control unit.

GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

GENSET SUPPLEMENTS

IV poles - 90A. IV poles - 140A.

Earth rod.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Emergency stop button.

• Remote starting inhibition availability.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

Fuel filter water separator.

Three phase

Protections with

alarm

AUTOMATIC CONTROL PANEL (AMF)

Change over

contactors

Mains/Genset

Commands and

others

EEG: ENGINE ELECTRONIC GOVERNOR.

KRT: RENTAL KIT.. Complete of:

Battery switch.

1 x 400V/63A 3P+N+T CE.

1 x 230V/16A Schuko.

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

External terminal board

Output

Protections with

shutdown

APM: PMG FOR STAMFORD ALTERNATOR + MX321 AVR.

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Automatic control panel for

automatic starting by Mains

failure. Delivered loose from

the genset, and complete

with digital control unit

AC03 for monitoring,

control and protection of

the generating set. • Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage.

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage.

• Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel.

• Power cables connected to terminals board (internal).

AFP: AUTOMATIC FUEL TRANSFER PUMP.

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

PHS: COOLANT PREHEATING SYSTEM.

DCC: DIFFERENT CANOPY COLOUR.

1 x 400V/32A 3P+N+T CE.

Three way valve.

Manual set folder

Rev.00 (Ago2010) Pag. 2 of 3

Page 3: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

IV poles - 90A. IV poles - 140A.

GSW65P GSW80P

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

• Power cables connection to terminals board (internal).

MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION.

Output

Protections with

alarmManual control panel

mounted on the genset,

with analogue

instrumentation, and

protected through door with

lockable handle.

Commands and

others

1 x 230V/16A Schuko.

1 x 400V/63A 3P+N+T CE.

1 x 400V/32A 3P+N+T CE.

Instrumentation

(analogue)

CONTROL PANEL SUPPLEMENTS

• Voltmeter with selector switch (3 phases).

• Frequency meter.

• Ammeter with selector switch (3 phases).

• Hours-counter.

• Fuel level indicator.

• Oil pressure indicator.

• Engine temperature indicator.

• Start/stop selector switch with key (single key system)

• Emergency stop button.

• Engine protections: low fuel level, low oil pressure, high engine temperature, battery charger failure.

TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES.

Protections

Change over

contactors

Connections

Load transfer switch panel

built in a metal cabinet and

LOAD TRANSFER SWITCH PANEL.

• Plinth row for connection from ACP to LTS panel.

• Terminals board for power cables connection (Genset-Mains-Load).

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

SKB: SOCKETS KIT B WITH 5 SOCKETS.

with individual CB and Earth Fault protection

• Contactors mechanically and electrically interlocked.

• Emergency stop button.

ACCESSORIES

Protections with

shutdown

ETB: EXTERNAL TERMINAL BOARD. Heavy duty cupper bars of easy external power cables connection.

• Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure.

• Circuit breaker protection: III poles.

• Differential protection.

Three phase

RSS: REMOTE START/STOP. Only for MCP

RTR: ROAD TRAILER (only for Spanish terrritories). Single axle.

ACCESSORIES

GSB: GALVANIZED SKIDS. Heavy duty galvanized skid to be installed under the genset.

Easily transportable with fork lift.

built in a metal cabinet and

supplied loose from the

genset.

RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication

available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request.

These kits are only available on the automatic versions.

STR: SITE TRAILER. Single axle.

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It

transfers immediately the load again to the genset when the Mains voltage returns within the rated values.

Rev.00 (Ago2010) Pag. 3 of 3

Page 4: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Product Cards GSW65-80P (50Hzstf) Sound

Internal residential muffler.

Detachable central lifting point.

Complete with engine and battery liquids.

Oil draining facilities.

Baseframe capable to be moved with hand pallet truck.

Rental kit as option (POWER ON RENT).

PRIME POWER PRP

EMERGENCY POWER LTP

Voltage

Frequency

Power factor

DIESEL ENGINEBrand

Model

Hz

Dimensions (LxWxH) mm

LWA

dB(A)

Canopy made in zincted steel profiles with green power coated layer.

Weight (3ph)

Speed rpm

Cooling system

kg

Autonomy (75/100% load PRP) h

Acoustic pressure at 7m

Acoustic power

Fuel capacity

MODEL

CODE

Volt

Thre

e p

hase kVA (kW)

kVA (kW)

Cos φ

Litres

Liquid cooling Diesel engine.

Control panel protected by lockable door

MODEL|GSW65-80Perkins

Type

Fully bunded / Completly sealed baseframe as option.

1.085

Perkins

1103A-33TG2

Water

1.500

71

2.285x920x1.500

0,8

209

19,9 / 14,9

96

GSW65P (*)

SU600TPA

60,7 (48,6)

66,5 (53,2)

400

50

GSW80P (*)

SU800TPA

74,3 (59,4)

77,7 (62,2)

400

50

0,8

209

14,9 / 11,2

96

71

2.285x920x1.500

1.144

Perkins

1104A-44TG2

Water

1.500

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

REF. PC5208_3Me.00

MANUAL CONTROL PANEL (MCP)

ALTERNATOR 3ph

Mechanical degree protection

Volt

Displacement

Cyliders and disposition

l/h

c.c.

Type

Type (%)

Type

Commands and

others

Protections with

shutdown

Instrumentation

(analogue)

Manual control panel,

mounted on the genset and

complete of: analogue

instrumentation, control,

protection of the generating

set and sockets, protected

through door with lockable

handle.

Voltage regulation

g/kWh

Electrical system (DC)

Engine governor

Fuel consumption (75/100% load)

Engine power PRP / LTP

Speed rpm

kWm

Aspiration

Specific consumption PRP

n° disp.

• Start/stop selector switch with key (Glow plugs preheating function also included).

• Emergency stop button installed on canopy side.

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

MeccAlte

MANUAL CONTROL PANEL (MCP)

Protections with

alarm

Insulation Class

• Power cables connected to Circuit Breaker

Electronic (±1,5%)

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

• Circuit breaker protection: III poles.

• Differential protection.

• Genereting set voltage (1 phase).

• Generating set current (1 phase).

• Hours-counter.

Ouput

1.500

3.300

3 L

Turbo

53,8 / 59,3

10,5 / 14,0

228

Mechanical

12

ECO 32 2L

H

IP21

1.500

4.400

4 L

Turbo

71,9 / 79,1

14,0 / 18,7

229

Mechanical

12

ECO 32 3L

H

IP21

GSW65P GSW80P

(*) Only for non mobile applications, according to COM II regulation.

Type

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

REF. PC5208_3Me.00

Rev.00 (Ago2010) Pag. 1 of 3

Page 5: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Product Cards GSW65-80P (50Hzstf) Sound

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

Ouput

AUTOMATIC CONTROL PANEL (AMF)

AUTOMATIC CONTROL PANEL (AMF)

Automatic control panel

mounted on the genset,

complete with digital control

unit AC03 for monitoring,

control and protection of the

generating set, protected

through door with lockable

handle.

AUTOMATIC CONTROL PANEL (ACP)

Digital

instrumentation

through AC-03

control unit.

Protections with

shutdown

GSW65P GSW80P

AUTOMATIC CONTROL PANEL (ACP)TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model).

Digital

instrumentation

through AC03

control unit.

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model).

Commands and

others

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Remote starting availability.

• DC system disconnection switch.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

• Emergency stop button installed on canopy side.

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage

• Plinth row for connection from ACP to LTS panel.

GSW80P

Protections with

alarm

• Power cables connected to Circuit Breaker

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

• Circuit breaker protection:III poles.

• Differential protection by means of the control unit.

GSW65P

GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

IV poles - 90A. IV poles - 140A.

1 x 400V/63A 3P+N+T CE.

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Emergency stop button.

• Remote starting inhibition availability.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

Fuel filter water separator.

Three phaseChange over

contactors

Mains/Genset

AUTOMATIC CONTROL PANEL (AMF)

Output

Commands and

others

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

External terminal board

Earth rod.

Battery switch.

1 x 230V/16A 2P+T CE.

Manual set folder

KRT: RENTAL KIT.. Complete of:

Protections with

alarmTECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

Automatic control panel for

automatic starting by Mains

failure. Delivered loose from

the genset, and complete

with digital control unit

AC03 for monitoring,

control and protection of the

generating set. • Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage.

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage.

• Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel.

• Power cables connected to terminals board (internal).

AFP: AUTOMATIC FUEL TRANSFER PUMP.

Three way valve.

1 x 230V/16A Schuko.

1 x 400V/32A 3P+N+T CE.

DCC: DIFFERENT CANOPY COLOUR.

EEG: ENGINE ELECTRONIC GOVERNOR.

PHS: COOLANT PREHEATING SYSTEM.

Protections with

shutdown

1 x 400V/16A 3P+N+T CE.

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

Rev.00 (Ago2010) Pag. 2 of 3

Page 6: PCsu GSW65-80P stf 50Hz Soundproof Stamford Trifasic Rev ... · • Engine protections: low fuel level, low oil pressure, high engine temperature, • Genset protection: under/over

Product Cards GSW65-80P (50Hzstf) Sound

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

GSW65P GSW80P

IV poles - 90A. IV poles - 140A.

1 x 230V/16A Schuko.

1 x 400V/63A 3P+N+T CE.

1 x 400V/32A 3P+N+T CE.

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

• Power cables connection to terminals board (internal).

• Voltmeter with selector switch (3 phases).

• Frequency meter.

• Ammeter with selector switch (3 phases).

• Hours-counter.

• Fuel level indicator.

• Oil pressure indicator.

• Engine temperature indicator.

Output

Protections with

alarm

Manual control panel

mounted on the genset, with

analogue instrumentation,

and protected through door

with lockable handle.

CONTROL PANEL SUPPLEMENTS

TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES.

Protections with

shutdown

ETB: EXTERNAL TERMINAL BOARD. Heavy duty cupper bars of easy external power cables connection.

Commands and

others

• Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure.

• Circuit breaker protection: III poles.

• Differential protection.

• Start/stop selector switch with key (single key system)

• Emergency stop button.

• Engine protections: low fuel level, low oil pressure, high engine temperature, battery charger failure.

Protections

Change over

contactors

Connections

Load transfer switch panel

LOAD TRANSFER SWITCH PANEL.

• Plinth row for connection from ACP to LTS panel.

• Terminals board for power cables connection (Genset-Mains-Load).

• Contactors mechanically and electrically interlocked.

• Emergency stop button.

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

SKB: SOCKETS KIT B WITH 5 SOCKETS.

with individual CB and Earth Fault protection

MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION.

ACCESSORIES

Three phase

RSS: REMOTE START/STOP. Only for MCP

Instrumentation

(analogue)

ACCESSORIES

GSB: GALVANIZED SKIDS. Heavy duty galvanized skid to be installed under the genset.

Easily transportable with fork lift.

Load transfer switch panel

built in a metal cabinet and

supplied loose from the

genset.

RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication

available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request.

These kits are only available on the automatic versions.

STR: SITE TRAILER. Single axle.

RTR: ROAD TRAILER (only for Spanish terrritories). Single axle.

Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers

immediately the load again to the genset when the Mains voltage returns within the rated values.

• Emergency stop button.

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS W

ITHOUT PRIOR NOTICE

Rev.00 (Ago2010) Pag. 3 of 3