paperless recording system · paperless recording system ... replace paper chart recorders and save...
TRANSCRIPT
437ISP ’12
Paperless Recording System
Versatile data recording and intuitive operation
Replace paper chart recorders and save cost of supplies and maintenance. Flexible I/O and networking capabilities.
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12
G
438
438 Paperless Recorder
73VR SeriesSignal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electric Actuators& Position Sensors
Lightning Surge Protectors
73VR Series
Paperless Recording System
73VR3100
73VR2100
73VR1100
71VR1
Replace paper chart recorders and save cost of supplies and maintenance.Environmentally friendly data recording solution – no chart paper, pens and cartridges.73VR Series offers 3 types to select in many applications.Versatile data recording.
◆ Touch panel operation
◆ Selectable number of pens to display
◆ 5.5-inch TFT color display with backlight
◆ Selectable chart colors available White or from blue to black (plain light, plain dark or gradation)
◆ IP65 front cover
Remote I/O type 73VR1100
Built-in universal input type
73VR2100
Selectable input module type 73VR3100
Direct operation and configuration from PLC ◆ The host PLC can control the 73VR3100 via built-in gateway module to start/stop recording, enter comments and set displays. *1
◆ Data sent from PLC can be displayed and recorded. *2
*1. In “Remote” mode, local control at the 73VR3100 is locked*2. Storing rate 20msec. is not selectable
PLC
Input Input
Open Network
73VR3100
Operator Panel
OperationOperation, Data
Data
Data
■ Gateway Interface Modules*3
Network Model Function
R3-GC1 Ver. 2.00
R3-GD1 Analog 64 ch.
Modbus/TCP R3-GE1 Ethernet
Modbus R3-GM1 RS-485
R3-GFL1 OPCN-2FL-net
New Feature of Paperless Recorder 73VR3100
*3. The number of gateway module vary by its settings
NEWNEW
73VR3100,73VR2102,73VR2104,73VR2106,73VR2108,73VR2110,73VR211
2,73VR1100
73VR2100 73VR310073VR1100
Specifications are subject to change without notice.ISP ’12
G
439
439Paperless Recorder with selectable built-in I/O 73VR3100Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electric Actuators& Position Sensors
Lightning Surge Protectors
Paperless Recording System
73VR Series
73VR3100
73VR2100
73VR1100
71VR1
■ Paperless Recorder with selectable built-in I/O 73VR3100
Selectable input modules.
◆ Up to four R3 Series I/O modules can be selected (Max. 64 inputs).
◆ By replacing one of the I/O modules with Network Module for the R3 Series, the 73VR3100 can directly communicate to major PLC via Modbus, Ethernet (Modbus/TCP), DeviceNet, PROFIBUS-DP, CC-Link, LONWORKS, T-Link and FL-net.
◆ 20 msec. storing rate with the combination of 8 analog and 8 discrete inputs.
◆ Real time trending and recording on the PC Recorder software MSR via Ethernet.
Number of input channels 4 through 64Function pen points 16, 64Storing rate (high speed mode) 20 msec., 100 msec.
Storing rate (normal mode)
500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes
Input typesR3 series I/O modules (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse, Di/o)
Trigger input Max. 64 (depending on input modules types)Alarm/Run output Max. 32 (depending on input modules types)Weight 2.3 kg (5.1 lbs) except I/O modulesDisplay•Display device 5.5-inch TFT LCD•Display colors 256•Resolution 320 × 240 pixels
Ethernet10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX)
Degree of protection
IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout)
CE marking –
5.5-inch TFT LCD touch panel screen
Selectable I/O modules (max. 4)
Network / Gateway modules
Open network module installed, using 73VR3100 as remote I/O with local display and recording function.
PLC
PLC PLC
CPU
73VR3100
73VR3100
InputInput
Input Input
Isolator
Open Network
Open Network
Recorder Operator Panel Operator Panel
Display & recording data input to a control system
SPECIFICATIONS
Flexible I/O capability using the R3 series modules. Compatible with various open networks.
73VR3100
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12
G
440
440 Paperless Recorder with built-in I/O 73VR2100
Intuitive “Help View” screen for easy user setup and use.
Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electric Actuators& Position Sensors
Lightning Surge Protectors
73VR Series
Paperless Recording System
73VR3100
73VR2100
73VR1100
71VR1
■ Paperless Recorder with built-in I/O 73VR2100
Built-in universal input modules.Universal input – DC, Thermocouple, RTD
◆ Independent input type and range selectable for each channel
◆ 100 msec. storing rate up to 6 point
◆ 2, 4, 6, 8, 10 or 12 points
◆ Real time trending and recording on the PC Recorder software MSR via Ethernet
Number of input channels 2, 4, 6, 8, 10 or 12Function pen points 12Storing rate (high speed mode) 100 msec.
Storing rate (normal mode)
500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes
Input types Universal input (DC mV and voltage, thermocouple, 3-wire RTD)
Trigger input Dry contact × 1Alarm/Run output Relay contact × 1Weight 2.4 kg (5.3 lbs)Display•Display device 5.5-inch TFT LCD•Display colors 256•Resolution 320 × 240 pixels
Ethernet10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX)
Degree of protection
IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout)
CE marking Yes
DC Voltage Input resistance 900kΩ minimum (Excluding the case in which, with range setting other than ±12V, ±6V or ±3V, a voltage exceeding ±1.3V is applied.)
Input range ±60mV, ±125mV, ±250mV, ±500mV, ±1000mV, ±3V, ±6V, ±12V
DC Current 4-20mA, use optional REM3-250 resistor module
Thermocouple Input range (PR), K (CA), E (CRC), F (IC), T (CC), B (RH), R, S, C (WRe 5-26), N, U, L, P (Platinel II)
Burnout sensing • Upscale: ≤130nA• Downscale: ≤220nA• No burnout: ≤10nA
RTD (3-wire) Input range Pt 100 (JIS ’89), Pt 100 (JIS ’97, IEC), Pt 200, Pt 300, Pt 400, Pt 500, Pt 1000, Pt 50Ω (JIS ’81), JPt 100 (JIS ’89), Ni 100, Ni 120, Ni 508.4Ω, Ni-Fe 604, Cu 10 @25°C
Burnout sensing Upscale or Downscale: ≤130nAAllowable lead-wire resistance 20Ω per wire
QUICK SETUP
SPECIFICATIONS INPUT TYPE
73VR2102,73VR2104,73VR2106,73VR2108,73VR2110,73VR2112,
Model Function
73VR2102 Paperless Recorder (built-in input modules, 2-point inputs)
73VR2104 Paperless Recorder (built-in input modules, 4-point inputs)
73VR2106 Paperless Recorder (built-in input modules, 6-point inputs)
73VR2108 Paperless Recorder (built-in input modules, 8-point inputs)
73VR2110 Paperless Recorder (built-in input modules, 10-point inputs)
73VR2112 Paperless Recorder (built-in input modules, 12-point inputs)
Specifications are subject to change without notice.ISP ’12
G
441
441Paperless Recorder with Remote I/O 73VR1100Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electric Actuators& Position Sensors
Lightning Surge Protectors
Paperless Recording System
73VR Series
73VR3100
73VR2100
73VR1100
71VR1
■ Paperless Recorder with Remote I/O 73VR1100
Connects to remote I/O.Designed to utilize a wide variety of M-System's remote I/O devices.
◆ Best suited to record data transmitted from I/O located remotely in the field, or inside an instrumentation or control cabinet.
◆ Instead of using expensive sensor cables, reduce wiring runs by using open field networks through remote I/O.
◆ I/O separated 73VR1100 provides the installation flexibility which fits in the tight space of a control panel or machinery chassis.
Number of input channels 64, 128 (Function pen points included)Function pen points 32, 64Storing rate (high speed mode) 100 msec.
Storing rate (normal mode)
500 msec., 1, 2, 5, 10 seconds, 1minute, 10 minutes
Input typesR3 series I/O modules (DC voltage, DC current, Thermocouple, RTD, AC voltage, AC current, Encoder, Totalized pulse)
Trigger input Max. 128 via remote I/O
Alarm/Run output Alarm × 1, Run × 1; Alarm also available via remote output modules
Weight 1.7 kg (3.7 lbs)Display•Display device 5.5-inch TFT LCD•Display colors 256•Resolution 320 × 240 pixels
Ethernet10BASE-T / 100BASE-TX automatically switched; Conforms to IEEE802 (10BASE-T) or IEEE802.3 (100BASE-TX)
Degree of protection
IP65 (applicable to the front panel of with the cover closed when a single unit is mounted according to the specified panel cutout)
CE marking Yes
73VR1100 R3 Series
R7 Series
73VR1100
Up to 128 points
Max. 500 metersModbus RS-485
Remote I/O
Up to 15 remote I/O Ethernet - Up to 2 stations
Multichannel remote data acquisition
Reduce wiring cost
73VR1100
Sensor Sensor Sensor Sensor
Remote I/O
SPECIFICATIONS
73VR1100,
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP ’12
G
442
442 Compact Paperless Recorder
71VR1Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electric Actuators& Position Sensors
Lightning Surge Protectors
73VR Series
Paperless Recording System
73VR3100
73VR2100
73VR1100
71VR1
73VR Series
Paperless Recording System
73VR3100
73VR2100
73VR1100
71VR1
◆ 1/4 DIN size (96 x 96 mm) panel mount compact recorder
◆ 3.5 inch TFT color LCD display
◆ Max. 8-point each of analog and discrete inputs are stored, displayed and alerted.
◆ Max. 8-point discrete outputs can be assigned for alarm trips.
◆ Direct field inputs at the built-in terminals and optional remote inputs via Modbus RTU
◆ Data can be transferred to PC via the front IR port
■ Remote I/O Type 71VR1-E001 ■ DC Input Type 71VR1-E101 ■ Universal Input Type 71VR1-E501
Do x 2
Remote I/O
Analog sensorinput x 8
Discreteinput x 6
Discreteoutput x 6
Di x 2
Modbus RS-485
Do x 2
Remote I/O
Analog sensor input x 6Discrete input x 6
Discrete output x 6
Di x 2
Modbus RS-485
DC V/mA input x 2
Do x 2
Remote I/O
Analog sensor input x 3Discrete input x 6
Discrete output x 6
DC V/mA input x 2
Universal input x 3(DC, TC and RTD)
Di x 2
Modbus RS-485
FUNCTION MODEL
Di x 2, Do x 2 and Modbus 71VR1-E001Di x 2, Do x 2 and Modbus+ DC mA/V input x 2 71VR1-E101
Di x 2, Do x 2 and Modbus+ DC mA/V input x 2 + Universal input x 3 71VR1-E501
M-System’s Model 71VR1 is a 1/4 DIN size (96 x 96 mm panel cutout), compact paperless recorder that can store and display the maximum of 8-point analog inputs and 8-point discrete inputs. The 3.5 inch TFT color LCD display can show two pen channels at once on a trend graph or digital/bargraph indicators.Field signals are connected to local terminals and polled remotely from Modbus RTU I/O devices. Three models are available depending on the number of local inputs.Data sampling rate is selectable between 100 msec. and 10 seconds depending upon the type and number of local and remote inputs. In addition to manual and continuous recording mode, conditional recording triggered by AND/OR functions in combinations of analog/discrete signal values/states is available. This allows the user to record only necessary part of the data in order to save memory area.Each analog input signal is independently set with four (4) alarm thresholds. In addition to the built-in DO terminals, at the maximum of 8-point discrete outputs can be mapped on remote output devices to alert externally. Alarm events are recorded in an alarm history file, up to 200 events.Data is stored in a memory card at the rear side of the recorder, and can be transferred to a PC and converted into CSV format files with this card or via the front IrDA port.Thanks to its small panel size and shallow depth of only 10 centimeters (4 inches) needed behind the panel surface, the 71VR1 can be mounted on control panels built into industrial and commercial machineries. Imagine the 71VR1 mounted on a wave soldering machine. Single unit can monitor and record solder temperature, conveyor speed, starting/stopping of the machine, current consumption and their alarm history.IP 65 front panel is also suitable for applications and installations where splashing water is present such as sanitary plants.
71VR1 71VR1
Trend Graph Alarm History