pain points in practice and - ppa-europe.euthe european association for panels and profiles pain...
TRANSCRIPT
![Page 1: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/1.jpg)
The EuropeanAssociation for
Panels and Profiles
Pain pointsin practice and
possible solutionsfor panels
Prof. Dr.-Ing. Klaus Berner
![Page 2: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/2.jpg)
Slide 2
Pain Points
what means pain points??a number of issueswhich are not satisfactorily solvedbut which are very important for theapplication of sandwich panels andwhich should be definitely improved
![Page 3: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/3.jpg)
Slide 3
Main Topics
Ø Hidden fixingØ Visible fixingØ Stiffening effect of sandwich panels for
substructuresØ Panels as supporting substructures for
facadesØ Resistance of sandwich panels to point
loads and line loads
![Page 4: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/4.jpg)
Slide 4
Pain Points
Hidden fixing
![Page 5: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/5.jpg)
Slide 5
Hidden fixing, schematic pictures
![Page 6: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/6.jpg)
Slide 6
Characteristic values for hidden fixing in a German approval
![Page 7: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/7.jpg)
Slide 7
Example
maximum utilization of the panel: 89,3 %utilization of the fixing:
Fixing with two screws and a plate!
Support no.5: 163 %
Support no.4: 169 %
Support no.3: 120 %
Support no.2: 189 %
Support no.1: 145 %
stat. system:
l»3,
2m
Panel: PUR; D = 175 mm,t1 = 0,75 mm, t2 = 0,50 mm, lightly profiled
![Page 8: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/8.jpg)
Slide 8
Example
Fixing with two screws and a plate!
Support no.10: 163 %Support no. 9: 96 %Support no. 8: 72 %Support no. 7: 75 %Support no. 6: 83 %Support no. 5: 82 %Support no. 4: 87 %Support no. 3: 76 %Support no. 2: 97 %Support no. 1: 175 %
utilization of the fixing: stat. system:
l»1,
5m
maximum utilization of the panel: 78,8 %
Panel: PUR; D = 175 mm,t1 = 0,75 mm, t2 = 0,50 mm, lightly profiled
![Page 9: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/9.jpg)
Slide 9
Test arrangement for hidden fixing
![Page 10: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/10.jpg)
Slide 10
failure state, compression
![Page 11: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/11.jpg)
Slide 11
Possible improvement
![Page 12: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/12.jpg)
Slide 12
Possible improvement with additional steel plates
![Page 13: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/13.jpg)
Slide 13
Possible improvement with additional steel plates
![Page 14: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/14.jpg)
Slide 14
Possible improvement with additional steel plates
![Page 15: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/15.jpg)
Slide 15
Summery for improvement for hidden fixing
Summery:
ØHow can we make it better with the pain point just shown andsolve the problems??ØThis is in my opinion only possible by systematic, general
studies with universally valid results for the benefit of the wholesandwich industry!
![Page 16: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/16.jpg)
Slide 16
Pain Points
Visible fixing
![Page 17: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/17.jpg)
Slide 17
Example for a practical design
![Page 18: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/18.jpg)
Slide 18
Example for a practical design
2 3,25 m
2,75 m
stat. system
Position 2: 2-span-panelPanel: PUR; D = 60 mmt1 = 0,50 mm, t2 = 0,40 mmlightly profiled
colorgroup IIIwind suction: -0,78 kN/m2
wind suction for fasteners: -0,91 kN/m2
substructure: Z-profile; t = 3 mm
maximum utilization of the panel: 81,7 %
![Page 19: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/19.jpg)
Slide 19
Visible fixing, ETA
EJOT JT3-6-5,5 x L
![Page 20: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/20.jpg)
Slide 20
Example for a practical design
Design of fixing:max. uplifting support force: 6,12 kN/m
for the middle-support with cold formed substructuren = 6 screws EJOT JT3-6-5,5 x L are needed
NR,k/per screw = 1,90 kN * 0,7 = 1,33 kN; gM = 1,33NS,d = 6,12 kN / 6 screws = 1,02 kN ≈ 1,00 kN = 1,33 kN / 1,33 = NR,d
But:Big pain point! Because of the large
number of required screws!!
![Page 21: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/21.jpg)
Slide 21
Dependence of the wrinkling stress on the number of screws
The wrinkling stresses for the outer faces upon thecentral support are only valid for fixing up to a maximumof 3 screws per meter. For more screws per meter thesewrinkling stresses shall be reduced with the factor
k = (11 - n) / 8 (n = number of screws per meter).
In the example with n = 6 screwsreduction factor: k = (11 - n) / 8 = (11 – 6) / 8 = 0,625σw,reduced = k * σw = 0,625 * 115 N/mm2 = 71,8 N/mm2
![Page 22: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/22.jpg)
Slide 22
Example for a practical design
Design for the panel not fulfilledØ A panel with higher load bearing capacity shall be chosen
e.g. panel: PUR; D = 60 mm; t1 = 0,75 mm, t2 = 0,60 mm(instead of t1 = 0,50 mm, t2 = 0,40 mm )
Big pain point!
Take into account the reduction factormaximum utilization
of the panel: 131,0 %
![Page 23: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/23.jpg)
Slide 23
Test set-up for pull-through tests with steel strips
![Page 24: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/24.jpg)
Slide 24
Testing based on small sandwich panel specimens
![Page 25: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/25.jpg)
Slide 25
Background on the definiton of thed value VR,k
NR,k/per screw = 1,90 kN * 0,7 = 1,33 kN
Value defined in ETA …
Test result (5% fractile value) x 0,67
Required acc. toEAD DP 15-33-0548-06.2, chapt. 2.2.2.4Fastening screws for sandwich-panelsαcycl. = 2/3 = 0,67, takes into account theinfluence of repeated wind loads
Reduction factor
Required acc. toETA 13/0177, chapt. 4.2.1Reduction 0,7 is taken into account forconnections of sandwich panels to thin walledasymmmetric profiles like Z- or C- shapedprofiles
![Page 26: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/26.jpg)
Slide 26
Realistic characteristic values for VR,k
ØRealistic characteristic values for the tensile resistance VR,k
NR,k = value given in ETA / 0,67 x 0,7
no influence of cycling loading no influence regarding thinwalled asymmetric profiles
In the example:relevant NR,k = 1,90 kN / 0,67 = 2,84 kN (instead of 1,33 kN!!)That means an improvement of 2,84 / 1,33 = 2,13 = 213 %n = 3 screws EJOT JT3-6-5,5 x L are neededNS,d = 6,12 kN / 3 screws = 2,04 kN ≤ 2,13 kN = 2,84 kN / 1,33 = NR,d
That means: Only 3 screws are neededby that no reduction for the wrinkling stress is required and theoriginally chosen panel can be used
![Page 27: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/27.jpg)
Slide 27
Summery for improvement for visible fixing
Summery:
Even if I see the situation somewhat too positive I think it isabsolutely clear that there is a great potential to improve thedesign of the fastening with visible fixing and to reduce the currentpain points.
![Page 28: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/28.jpg)
Slide 28
Values for resistance for steel grade S220
At the end I would like to mention one more but a smaller paint point:
The values for resistance in the Annexes of the ETA are always for asteel grade higher than S 280.But a lot of sandwich panel types have faces with S 220 or S 250.In these cases no official valid design values are available for thefastening. New tests or an (un-)official defined adjustment(extrapolation) are necessary.
![Page 29: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/29.jpg)
Slide 29
Summery for improvement for hidden fixing
Summery:
ØHow can we make it better with the pain point just shown andsolve the problems??ØThis is in my opinion only possible by systematic, general
studies with universally valid results for the benefit of the wholesandwich industry!
![Page 30: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/30.jpg)
Slide 30
Pain Points
Stiffening effect of sandwichpanels for substructures
![Page 31: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/31.jpg)
Slide 31
Stiffening effect of sandwich for supporting structures
Parameters needed for determining stiffening effect of sandwichpanels when connected to supporting structures
Annex G(normative)
CEN/TC 128prEN 14509-2
![Page 32: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/32.jpg)
Slide 32
Stiffening effect of sandwich for supporting structures
![Page 33: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/33.jpg)
Slide 33
Exampel for the influence of torsional restraint
at CϑA = 0,0
at CϑA = 0,5
at CϑA = 0,9
Load bearing capacity for wind suction loading for aCold formed Profile C 140-30, t = 3 mm, L = 6,0 mregarding different torsional restraint of sandwich panels
© Ingenieurbüro Schrag, Netphen
qR,d = - 1,11 kN/m
qR,d = 1,75 kN/m
qR,d = 2,02kN/m
![Page 34: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/34.jpg)
Slide 34
Test set up for heavy hot rolled profiles
![Page 35: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/35.jpg)
Slide 35
No torsional restraint by uplift loading
There is no torsional restraint by sandwich panels foruplifting loading (wind suction) due to the gap betweenupper flange of the beam and the inner face of thepanel caused by the indentation of the fastener`shead.
![Page 36: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/36.jpg)
Slide 36
Test set up for thin walled profiles
The sandwich panels are loaded by a load q ( e.g. wind pressure orwind suction). The profile is loaded by a horizontal line load, whichcauses the rotation of the beam.
in contrast to the set-up for heavy hot rolled profiles the set-uphas to be adapted for thin walled Z- or U-profiles, as follows:
![Page 37: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/37.jpg)
Slide 37
test with thin walled profiles
![Page 38: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/38.jpg)
Slide 38
Summery for improvement for hidden fixing
Summery:
ØHow can we make it better with the pain point just shown andsolve the problems??ØThis is in my opinion only possible by systematic, general
studies with universally valid results for the benefit of the wholesandwich industry!
![Page 39: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/39.jpg)
Slide 39
Pain Points
Panels as supportingsubstructures for facades
![Page 40: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/40.jpg)
Slide 40
sandwich panels with additional attached facades
![Page 41: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/41.jpg)
Slide 41
sandwich panels with additional attached facades
![Page 42: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/42.jpg)
Slide 42
Sandwich panel as a vertically upright positioned beam
A
A
section A-A
![Page 43: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/43.jpg)
Slide 43
Research with sandwich beams
![Page 44: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/44.jpg)
Slide 44
Sandwich panel as a vertically upright positioned beam
A
A
section A-A
Torsionalmoment
S
![Page 45: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/45.jpg)
Slide 45
Summery for improvement for hidden fixing
Summery:
ØHow can we make it better with the pain point just shown andsolve the problems??ØThis is in my opinion only possible by systematic, general
studies with universally valid results for the benefit of the wholesandwich industry!
![Page 46: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/46.jpg)
Slide 46
Pain Points
Resistance of sandwich panelsto point loads and line loads
![Page 47: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/47.jpg)
Slide 47
point-loads on sandwich panels due of solar-photovoltaic-systems on the roof
load-bearing widths
![Page 48: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/48.jpg)
Slide 48
Point loads, possible load positions
To cover all possible effects due to point loads under all possible loadpositions only per testing (design by testing), a very large number oftests would be required. It would need tests for each panel type, allstatic systems with all load positions.
point load firstflange
point load second flange
0,5*L0,15*L0,3*L
![Page 49: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/49.jpg)
Slide 49
simplified procedure
To reduce the number of tests only confirmation tests mustbe done, regarding load bearing widths given in DIN 18807,Part 3, Table 2 for point loads for concrete-filled trapezoidalsheets . If these widths are in a first step accepted, tests canbe carried out for example only for one span panels.
![Page 50: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/50.jpg)
Slide 50
Available list of load bearing widths
But the availablelists are out of date and thestructural behavior ofconcrete-filled trapezoidalsheets and sandwich panelsis different for sure.
List of load bearing widthsgiven in DIN 18807, Part 3,Table 2
![Page 51: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/51.jpg)
Slide 51
Missing valid list of effective width for all sandwich panels
It is therefore a major pain point that there are no valid listsfor effective width specifically for sandwich panels, so thatthese costly tests are not necessary again and again. Ofcourse, extensive series of tests, possibly in the context ofbasic researching should be the base.
![Page 52: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/52.jpg)
Slide 52
Summery for improvement for hidden fixing
Summery:
ØHow can we make it better with the pain point just shown andsolve the problems??ØThis is in my opinion only possible by systematic, general
studies with universally valid results for the benefit of the wholesandwich industry!
![Page 53: Pain points in practice and - ppa-europe.euThe European Association for Panels and Profiles Pain points in practice and possible solutions for panels Prof. Dr.-Ing. Klaus Berner](https://reader031.vdocuments.us/reader031/viewer/2022011813/5e4155b64538f0794f5e6a03/html5/thumbnails/53.jpg)
Slide 53
Pain points in practice and possible solutions for panels
Thank you for your attention!