packaged air conditioning systems · heat exchanger in mhi outdoor units are coated with specially...
TRANSCRIPT
![Page 1: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/1.jpg)
PACKAGED AIR CONDITIONING SYSTEMS
DUCTED | CEILING CASSETTE | CEILING SUSPENDED
![Page 2: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/2.jpg)
Mitsubishi Heavy Industries Air-Conditioners Australia PTY LTD (MHIAA) is one of Australia’s leading suppliers of premium residential and commercial air conditioning systems. Delivering engineering excellence for over 130 years, the MHI brand is instantly recognisable for quality and technological advancement.
With innovation central to both the organisation and the development of air conditioning systems, MHI carries a strong philosophy of engineering products that are designed to improve the lives of those who use them and, at the same time, create a sustainable future for our company and the world we live in.
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONERS AUSTRALIA
Interior designer and Television presenter Tara Dennis joins MHIAA as the brand’s first ambassador to Australia and New Zealand. With an extensive experience in home decoration and design, Tara represents the home renovator looking to improve the conditions in their homes and offices.
“As someone who has a passion for styling and renovating homes you want to push the boundaries and create a space that people love being in. Mitsubishi Heavy Industries Air-Conditioners Australia is the perfect extension of this and a brand that I am proud to be supporting” – Tara Dennis.
BRAND AMBASSADORTARA DENNIS
![Page 3: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/3.jpg)
Introduction
Contents
Our Technology
Ducted Sytems
Ceiling Cassette
Ceiling Suspended
Remote Control Options
Specifications
Product Specifications
Exterior Dimensions
Notes
2
3
4
5-7
8-10
11-12
13-19
20
22-25
26-34
35
CONTENTS
![Page 4: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/4.jpg)
OUR TECHNOLOGY
IMPROVED HEAT EXCHANGER
HIGH EFFICIENCY COMPRESSOR
BLUE FIN TECHNOLOGYCOATED PCB
WIDE OPERATION RANGE
With our advanced technology and high quality components, MHI air conditioners can operate in ambient outdoor temperatures as low as -15°C in heating mode and as high as +43°C in cooling mode (50°C for FDCA160/200).
This permits the installation in areas where temperature conditions can be considered extreme.
DC PAM INVERTER
The PAM control used in MHI air conditioners helps minimise loss of electricity and boost efficiency by allowing the unit to reach the temperature quickly before slowing down the compressor. This allows the unit to save energy while maintaining a comfortable temperature in the room.
IMPROVED HEAT EXCHANGER
Our new and improved heat exchanger, with a unique ‘M’ shape design, has been developed to improve refrigerant distribution and increase the systems effectiveness. The new design features a larger heat exchange area, boosting the unit’s overall efficiency.
HIGH EFFICIENCY COMPRESSOR
One of the key features that provides MHI’s range of air conditioners with its powerful performance is our highly efficient compressor. Combined with a Neodymium Motor that uses powerful, rare earth magnets, MHI air conditioners can deliver a higher motor efficiency while producing much less operational noise.
BLUE FIN TECHNOLOGY
Along with a new, efficient design, the heat exchanger in MHI outdoor units are coated with specially formulated layers that assist in preventing the hydrophilicity effect and also assists in reducing the corrosion rate of the aluminium section from harsh Australian weather conditions.
COATED PCB
To protect against humid weather a protective coating is applied to the circuit board in the outdoor unit, allowing it to withstand Australia’s varying weather conditions and ensure the longevity of your MHI system.
4
![Page 5: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/5.jpg)
With enhanced components incorporated into a slim and compact design, as well as improved serviceability, Mitsubishi’s Heavy Industries ducted systems deliver a reliable and highly efficient solution for applications with small ceiling clearances such as small and medium density apartments.
DUCTED SYSTEMS
5
![Page 6: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/6.jpg)
REMOTE CONTROL OPTIONS
More details on p.15
WIRED WIRELESS Wi Fi
RC-EX3 RC-E5 RCH-E3 RCN-KIT 4-E2 Phone not included
FEATURESMANUAL EXTERNAL STATIC PRESSURE SETTINGBy manually setting the external static pressure during installation, the FDUA series is able to deliver even and optimal airflow to each outlet.
INCREASED ENERGY EFFICIENCYWith an improved heat exchanger, designed to increase refrigerant distribution and overall output, combined with a our DC fan motor, the FDUA series boasts huge energy efficiencies with the 7.1kW achieving a high COP of up to 3.60 in heating and 3.2 in cooling.
QUITE OPERATIONThanks to our highly efficient DC fan motor the FDUA series boasts super quiet operation levels (25dBA on the FDUA71VF low setting) which ensures no interruptions to room acoustics.
DUCTED SYSTEMS
HIGH STATIC PRESSURE
SINGLE PHASE MODELS ( 7.1 kW - 14.0kW)THREE PHASE MODELS (12.5kW - 20.0kW)
Model lineup and product specifications on p.22
FDUA100-160VF (10.0kW - 16.0kW)
FDUA71VF (7.1kW) FDUA200VG (20.0kW)
FDUA SERIES
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
*Not all functions are available with all remote control options.
Keep the same air flow volume
Ceiling
FDUAIndoor unit
Setting No.
E.S.P.
No.1
10Pa
No.2
20Pa
No.3
30Pa
No.4
40Pa
...
...
No.17
170Pa
No.18
180Pa
No.20
200Pa
No.19
190Pa
case1
F D U A E S P R A N G E
case2
Duct Longer DuctDuct
Keep the same air flow volume
Ceiling
FDUAIndoor unit
Setting No.
E.S.P.
No.1
10Pa
No.2
20Pa
No.3
30Pa
No.4
40Pa
No.5
50Pa
No.6
60Pa
No.7
70Pa
No.9
90Pa
No.10
100Pa
No.8
80Pa
case1
F D U M E S P R A N G E
case2
Duct Longer DuctDuct
Keep the same air flow volume
Ceiling
Indoor unit
*Range of 80~150 Pa is set at ex-factory default. Range of 10~200 Pa is available by setting SW8-4 switch on at site.
Setting No.
E.S.P.
No.8
80Pa
No.9
90Pa
No.10
100Pa
No.11
110Pa
No.12
120Pa
No.13
130Pa
No.14
140Pa
No.16
160Pa
No.18
180Pa
No.17
170Pa
No.19
190Pa
No.20
200Pa
No.15
150Pa
case1 case2
<Expansion of external static pressure range>Previous
10~130PaCurrent
10~200Pa
Duct Longer DuctDuct
Ceiling
Indoor unit Duct Longer DuctDuct
6
![Page 7: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/7.jpg)
REMOTE CONTROL OPTIONS
More details on p.15
WIRED WIRELESS Wi Fi
RC-EX3 RC-E5 RCH-E3 RCN-KIT 4-E2 Phone not included
FEATURESAUTOMATIC EXTERNAL STATIC PRESSURE SETTINGThe automatic external static pressure can be set during installation. The FDUM indoor unit will adjust the fan speed as required to maintain the set ESP in ducts and deliver even and optimal airflow to each room.
IMPROVED SERVICEABILITYDesigned to improve serviceability for both the FDUA and FDUM series, the fan unit (comprising of impeller and motor) can be inspected easily due to the slide out fan deck innovative provision.
FLEXIBLE INSTALLATIONThe built-in drain pump which includes a lift of 600mm also allows greater flexibility with installation, offering a great solution for applications with limited space.
DUCTED SYSTEMS
MEDIUM STATIC PRESSURE
SINGLE PHASE MODELS ( 5.0 kW - 14.0kW)THREE PHASE MODELS (12.5kW - 14.0kW)
Model lineup and product specifications on p.23
FDUM SERIES
*Not all functions are available with all remote control options.
Keep the same air flow volume
Ceiling
FDUAIndoor unit
Setting No.
E.S.P.
No.1
10Pa
No.2
20Pa
No.3
30Pa
No.4
40Pa
...
...
No.17
170Pa
No.18
180Pa
No.20
200Pa
No.19
190Pa
case1
F D U A E S P R A N G E
case2
Duct Longer DuctDuct
Keep the same air flow volume
Ceiling
FDUAIndoor unit
Setting No.
E.S.P.
No.1
10Pa
No.2
20Pa
No.3
30Pa
No.4
40Pa
No.5
50Pa
No.6
60Pa
No.7
70Pa
No.9
90Pa
No.10
100Pa
No.8
80Pa
case1
F D U M E S P R A N G E
case2
Duct Longer DuctDuct
Keep the same air flow volume
Ceiling
Indoor unit
*Range of 80~150 Pa is set at ex-factory default. Range of 10~200 Pa is available by setting SW8-4 switch on at site.
Setting No.
E.S.P.
No.8
80Pa
No.9
90Pa
No.10
100Pa
No.11
110Pa
No.12
120Pa
No.13
130Pa
No.14
140Pa
No.16
160Pa
No.18
180Pa
No.17
170Pa
No.19
190Pa
No.20
200Pa
No.15
150Pa
case1 case2
<Expansion of external static pressure range>Previous
10~130PaCurrent
10~200Pa
Duct Longer DuctDuct
Ceiling
Indoor unit Duct Longer DuctDuct
Maintenance hole
Service space
100 ~ 200
150
~20
010
010
00 o
r mor
eor
mor
e Pipe
Fan unit
Energy Saving Silent Operation Weekly/Sleep/Peak-Cut Timer
Hi Power Automatic Operation
Self-Diagnostics
FDUM50-140VF (5.0kW - 14.0kW)
7
![Page 8: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/8.jpg)
With a modern yet discreet design, Mitsubishi Heavy Industries ceiling cassettes are designed to be easily integrated into any commercial space.
The award winning FDT range, which features new draught control technology and individual louvre control, eliminates uncomfortable draughts and ensures every corner of the room is kept at an optimal temperature.
CEILING CASSETTE
8
![Page 9: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/9.jpg)
FEATURES
Draft prevention panel workingDraft prevention
panel not workingCOOLING
HEATING
DRY
FAN
LB-T-5W-E
Motion Sensor
LB-T-5W-E
Motion Sensor
Motion Sensor detectspresence/absence and
activity amounts ofhumans in a room toimprove comfort and
energy savingperformance.
CEILING CASSETTE
SINGLE PHASE MODELS ( 5.6 kW - 14.0kW)THREE PHASE MODELS (12.5kW - 14.0kW)
Model lineup and product specifications on p.24
FDT SERIES
DRAUGHT CONTROL TECHNOLOGY*New to the Australian and New Zealand market, MHI’s Draught Control Technology utilises 4 specially designed louvres to direct airflow horizontally along the ceiling, allowing it to evenly disperse within the room.
By controlling the airflow, these louvres, which are individually controlled via the touch-screen controller, eliminate uncomfortable and annoying draughts which can often occur with ceiling cassettes and ensures every corner of the room is kept at the perfect temperature. * This feature can only be enabled using the RC-EX3 wired controller.
MOTION SENSOR (OPTIONAL)The new optional motion sensor regulates temperature settings according to the level of human activity detected in the room. This enables energy saving mode when the human activity is low and will automatically turn the unit off when no activity is detected for 12 hours.
EASY INSTALLATION AND SERVICINGThe built-in drain pump on our FDT ceiling cassettes can be conveniently discharged up to 850mm upwards allowing for more flexibility during installation and easier servicing.
Energy Saving Hi Power Louvre Control Home Leave Silent Operation Favourite Setting
*Not all functions available with all remote control options.
NEW
REMOTE CONTROL OPTIONS
More details on p.15
WIRED WIRELESS Wi Fi
RC-EX3 RC-E5 RCH-E3 RCN-T-5AW-E2 Phone not included
FDT60-140VG (5.6kW - 14.0kW)
9
![Page 10: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/10.jpg)
FEATURES
SINGLE PHASE MODEL ( 5.0 kW)
Product specifications on p.24
FDTC SERIES
COMPACT CEILING CASSETTE
COMPACT DESIGNWith one of the smallest designs on the market (with a height of just 248mm and weight of 15kg) the FDTC series delivers a compact and convenient solution suitable for a variety of applications where roof space is at a premium.
*Not all functions available with all remote control options.
AIRFLOW DIRECTION CONTROLUsers can control the airflow distribution by adjusting the position of the louvres on the indoor unit. The angle of each louvre can be easily changed remotely from the unit’s wired control display.
OUTSIDE AIR INTAKE (OPTIONAL)The Outside Air (OA) spacer which comes as an optional extra, is used to draw fresh air from outside, into circulation indoors. This is beneficial for commercial spaces where a fresh air system is unable to be installed.
EASY INSTALLATION AND SERVICINGThe built-in drain pump on our FDTC ceiling cassettes can be conveniently discharged up to 600mm upwards allowing for more flexibility during installation and easy maintenance and servicing.
Energy Saving Hi Power Flap Control Home Leave Silent Operation Favourite Setting
REMOTE CONTROL OPTIONS
More details on p.15
WIRED WIRELESS Wi Fi
RC-EX3 RC-E5 RCH-E3 RCN-TC-24W-ER Phone not included
FDTC50VF (5.0kW)
10
![Page 11: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/11.jpg)
MHI ceiling suspended systems offer a convenient alternative to wall mounted or floor standing systems and free up vital floor space, making them perfect for restaurants, cafes, stores and other applications where floor space is at a premium.
The new and improved FDE range includes a lighter design as well as offering no disruptions to room acoustics.
CEILING SUSPENDED
11
![Page 12: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/12.jpg)
FEATURES
WIRELESS
RCN-E-E2
1
2
3
SelectedUpper Position
Max SwingRange
SelectedLower Position
4
56
EFFICIENT AND QUIET The improved design of the fan motor and heat exchanger allows for a more energy efficient and quieter operation, with operation noise being reduced by up to 8dB (A)*. *applies to FDE125VG.
AIRFLOW DIRECTION CONTROLUsers can control the airflow distribution in the room by adjusting the louvre position on the indoor unit. By selecting from 1 of the 6 different set positions via the controller, users are able to achieve the desired airflow to suit their environment.
FLEXIBLE PIPE LAYOUTOur ceiling suspended units are designed to allow for maximum flexibility during the installation process. With refrigerant piping that can be arranged in 3 different directions (rear, right or up), combined with the drain outlet that allows water to be drained from either the left or right hand side of the unit, the FDE series allows for a variety of pipe layouts and caters to a range of applications with varied installation conditions.
CEILING SUSPENDED
SINGLE PHASE MODELS ( 7.1 kW - 14.0kW)THREE PHASE MODELS (12.5kW - 14.0kW)
Model lineup and product specifications on p.25
FDE SERIES
Energy Saving Hi Power Louvre Control Home Leave Silent Operation Favourite Setting
*Not all functions are available with all remote control options.
NEW
REMOTE CONTROL OPTIONS
More details on p.15
WIRED Wi Fi
RC-EX3 RC-E5 RCH-E3 Phone not included
FDE71 -140VG (7.1kW - 14.0kW)
12
![Page 13: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/13.jpg)
Whether you have a ducted system in your home or office or a ceiling suspended system in your cafe, retail store or other business, we have a solution to suit your needs with our flexible control options.
REMOTE CONTROL OPTIONS
13
![Page 14: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/14.jpg)
FULL CONTROLOF YOUR INDOOR CLIMATE
RC - EX3WIRED CONTROL
HIGH POWERRapid cooling/heating for 15 minutes to quickly adjust the room temperature to a comfortable level.
HOME LEAVE MODEMaintains the room temperature at a moderate level when the room is unoccupied for a prolonged period of time.
SILENT OPERATIONSet your system to run at reduced noise levels for certain periods of time. Perfect for night-time operation and an uninterrupted sleep.
FAVOURITE SETTINGSQuickly select your preferred combination of operation mode, temperature, fan speed and airflow direction with the click on a button.
SLEEP TIMERSet a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.
AIRFLOW DIRECTION CONTROLControl the airflow of your ceiling cassette or ceiling suspended unit by adjusting the louvre settings.
![Page 15: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/15.jpg)
The RC-E5 controller allows users to turn the unit ON/OFF, switch operation modes, adjust the temperature, fan speed and air flow direction (up or down), as well as set timer operation. RC-E5 can also display real-time operational data such as refrigerant and air temperatures, compressor speed and error codes.
INDIVIDUAL CONTROL
WIRED CONTROL
WIRELESS CONTROL
RCH-E3
NEW RC-EX3
WIRELESS KIT AND NEW REMOTE CONTROL THERMISTOR (OPTIONAL)
RC-E5With the ability to control up to 16 indoor units, RCH-E3 is intended for use in a setting where everyday users only need access to the basic functions.With the RCH-E3 users can turn the air conditioner ON/OFF and control the mode, temperature and fan speed settings.
The new and improved RC-EX3 incorporates a range of smart features and functions, giving you complete control over your MHIAA air conditioner.
Key Features:
• Easy to use, intuitive touch screen interface with back light.
• A variety of energy saving functions such as Energy Saving mode, Peak Cut timer, Night Setback mode, Home Leave Mode.
• Control airflow direction of your FDT, FDTC or FDE unit.
Key Features:
• Hi Power Mode
• Energy Saving Mode
• Home Leave Mode
• Silent Mode
• ON / OFF Timer
• Child Lock
• Sleep and weekly timers.
• Hi Power Mode temporarily boosts performance to rapidly cool or heat the room to desired temperature.
• Favourite setting to quickly revert to your preferred combination of operation mode, temperature, fan speed and airflow direction.
The SC-THB-E3 sensor is used in cases where the sensor in the indoor unit or the remote control can not detect the room temperature correctly or individual remote control in each room is not required.
FDTC
FDE FDUA/FDUM
FDT
RCN-TC-24W-ER
RCN-E-E2 RCN-KIT4-E2
RCN-T-5AW-E2
NEW
NEW
15
![Page 16: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/16.jpg)
CONTROLYOUR AIRANYTIME, ANYWHERENo matter where you are, enjoy the same control of your Mitsubishi Heavy Industries air conditioner as you would from your home remote, using your smartphone, tablet or computer.
*to be used in conjunction with MH-RC-WIFI-1 wi-fi adaptor
With Wi-Fi Control You Can:• Turn your air conditioner on and off
• Change the operation mode
• Adjust the fan speed
• Set the desired temperature in your room
• Set and control timers
Plus much more
Available for download
![Page 17: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/17.jpg)
CENTRAL CONTROL
BUILDING MANAGEMENT SYSTEMS
SC-SL1N-E
SC-WBGW256* (Web Gateway / BACnet Gateway)
SC-SL2NA-E
SC-LGWNB* (LonWorks Gateway)
SC-SL4-AE/BE
Simple, On/Off controller designed for centralised control of up to 16 indoor units.
Production By Order Provides On/Off control of up to 256 units. Designed for large commercial applications.
*Additional engineering service is required. Please consult your dealer or sale representative for more information.
Centralized control of up to 64 indoor units. Weekly timer function as standard.
Production By Order Centralised control of up to 96 indoor units connected to 1 network.
A large, easy to use, colour LCD touch screen offering control of up to 128 indoor units.
NEWNEW
Model Interface Remote Control
SRK-ZSX-SSRK-ZR-SSRK-ZS-S
SRF-ZMX-SSRR-ZM-S
RC-EX1ARC-E5
SC-BIKN-ESC-ADNA-E
FDTC-VFFDUM50VFFDE50VG
SC-ADNA-E
SRK series SRF/SRR series FDTC/FDUM/FDE series
SC-BIKN2-E
SC-ADNA-E
RC-EX3RC-E5
SC-ADNA-E SC-ADNA-E
SC-SL4-AESC-BIKN2-E
RC-EX3RC-E5
RC-EX3RC-E5
NETWORK CONTROL
17
![Page 18: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/18.jpg)
COMPLETE COMFORT THE ZONING SOLUTION WITHOUT LIMITATIONSAirzone, zoning solution offers the ultimate level of comfort by providing unrivalled control over your system and in turn, delivering high energy efficiencies and huge cost savings.
Top Of The Line, European Design Designed and manufactured in a state-of-the-art facility in Europe, all Airzone components, from the intelligent damper assemblies to the sleek and stylishly designed controllers are of the highest quality and designed to last.
High Efficiencies, Lower Running CostsAirzone’s Q-adapt algorithms, which constantly monitor temperatures and adjusts fan speeds accordingly, will ensure your unit is running as efficiently as possible, delivering huge cost savings.
Comfort In The Palm Of Your Hand Whether you’re at the office, on the move or just across the room, the easy to use Airzone Cloud app gives you complete access to all functions of the system.
Advanced Features, Simplified ControlsControl and monitor the temperature in up to 10 zones, access timers, scheduling and other advanced features via intuitive and easy to use controllers.
![Page 19: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/19.jpg)
CONTROLLER OPTIONSBLUEFACE – MAIN CONTROLLER
THINK – ZONE CONTROLLER
LITE – ZONE CONTROLLER
The sleek and stylish Blueface master controller gives you complete control over your system by allowing you to monitor and the temperatures in each individual zone, adjust airflow, access timers, schedules plus much more.
The THINK zone controller, with it’s low-energy, e-ink screen, provides accurate humidity and temperature reading and allows you to control the entire system or individual zones in your system, including temperature, operation mode and system speed.
The LITE controller offers the same level of accurate comfort control as the THINK controller, in a simplified and compact design. The LITE, which allows you to adjust the temperature in increments, but can be controlled completely via the Airzone cloud app is perfect for areas where you may want to limit access to controls but want full control remotely.
Key Features:
• Wired, intuitive, 3.5” colour touch screen
• Complete system control for up to 10 zones
• Temperature control of every zone
• System mode settings (Cool, Heat, Auto, Dry)
• Operation mode (Eco, Vacation, Stop, Comfort or Night)
Key Features:
• E-Ink-screen with capacitive buttons
• Complete system control for up to 10 zones
• Zone thermostat
• Wired or wireless (battery)
• System mode settings (Cool, Heat, Auto, Dry)
Key Features:
• Simplified zone temperature controller
• Zone thermostat & controller
• Set-point temperature control (accuracy: ±1ºC, up to a limit of ±3ºC)
• 7 day timer schedule
• Zone temperature control and humidity reading
• Technical system settings and readings
• Sleep mode
• Automatic system software updates* *Webserver Airzone Cloud WiFi must be installed.
• User operation mode (Eco, Vacation, Stop, Comfort or Night Time)
• 7 day timer schedule
• Sleep mode
• On/Off functionality
• Wired or wireless (battery)
CONTROL
Control temperature, operating mode and system speed.
ECO-ADAPT
Maximize your saving thanks to our Eco-Adapt saving function.
MASTER
Control all zones of your system.
SCHEDULES
Timers, scheduling and sleep modes
19
![Page 20: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/20.jpg)
SPECIFICATIONS20
![Page 21: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/21.jpg)
FEAT
URES
AN
D FU
NCT
ION
SFU
NCT
ION
DESC
RIPT
ION
FDT
FDTC
FDUA
FDUM
FDE
Louv
re C
ontro
l Sy
stem
This
func
tion
allo
ws
you
to s
et th
e up
per a
nd
low
er li
mit
posi
tions
of t
he lo
uvre
at e
ach
air o
utle
t in
divi
dual
ly, p
rovi
ding
you
with
com
plet
e co
ntro
l ove
r in
terio
r air
flow.
Auto
mat
ic F
an
Spee
d
The
unit’
s on
-boa
rd m
icro
com
pute
r con
tinuo
usly
m
onito
rs th
e ro
om’s
air
tem
pera
ture
and
adj
usts
the
air fl
ow a
utom
atic
ally.
Verti
cal A
uto
Swin
g
The
verti
cal l
ouvr
es o
n yo
ur u
nit w
ill m
ove
up a
nd
dow
n co
ntin
uous
ly d
urin
g op
erat
ion.
Thi
s fu
nctio
n al
low
s yo
u to
set
the
up/d
own
swin
g po
sitio
n of
the
louv
er to
you
r pre
ferre
d op
erat
ion
angl
e.
Air F
ilter
The
air fi
lter i
n th
e un
it tra
ps a
nd re
mov
es a
irbor
ne
dust
par
ticle
s an
d ot
her a
llerg
ens
to p
rovi
de y
ou w
ith a
cl
ean
air f
unct
ion.
Filte
r Sig
nTh
is w
arni
ng a
lerts
you
to w
hen
the
filte
r nee
ds to
be
clea
ned.
Out
side
Air
Inta
keTh
is fu
nctio
n pr
ovid
es c
lean
fres
h ai
r int
o th
e ro
om
thro
ugh
the
exte
rnal
air
inta
ke, a
void
ing
the
cons
tant
re
cycl
ing
of in
tern
al a
ir.
Self-
Dia
gnos
tics
The
inte
rnal
mic
roco
mpu
ter a
utom
atic
ally
runs
a
diag
nost
ic o
f the
sys
tem
in th
e ev
ent o
f a m
alfu
nctio
n.
This
ena
bles
you
r aut
horis
ed d
eale
r to
isol
ate
and
repa
ir an
y is
sues
.
Impr
oved
Se
rvic
eabi
lity
The
fan
unit
(com
pris
ed o
f im
pelle
r and
mot
or) i
s ea
sily
acc
essi
ble
from
eith
er th
e si
de o
r bot
tom
of t
he
unit
and
can
be s
lid o
ut fo
r eas
y m
aint
enan
ce.
Built
in D
rain
Pu
mp
The
built
-in d
rain
pum
p, w
hich
incl
udes
a li
ft of
60
0mm
, allo
ws
grea
ter fl
exib
ility
with
inst
alla
tion,
off
erin
g a
grea
t sol
utio
n fo
r app
licat
ions
with
lim
ited
spac
e. (F
DU
M a
nd F
DU
A m
odel
)
FUN
CTIO
NDE
SCRI
PTIO
NFD
TFD
TCFD
UAFD
UMFD
E
Set T
empe
ratu
re
Auto
Ret
urn*
This
func
tion
allo
ws
you
to p
rogr
am a
pre
ferre
d se
t te
mpe
ratu
re th
at th
e un
it w
ill re
turn
to e
ach
time
it is
op
erat
ed.
Hom
e Le
ave
Ope
ratio
n*
This
func
tion
ensu
res
that
whe
n th
e ro
om is
un
occu
pied
for l
ong
perio
ds o
f tim
e, th
e un
it w
ill m
aint
ain
a m
oder
ate
indo
or te
mpe
ratu
re, a
void
ing
extre
mel
y ho
t or c
ool t
empe
ratu
res.
Hi P
ower
O
pera
tion*
Use
the
high
pow
er fu
nctio
n to
qui
ckly
reac
h yo
ur
optim
um te
mpe
ratu
re le
vel w
hen
you
first
turn
on
the
unit.
Thi
s fu
nctio
n w
ill op
erat
e fo
r a m
axim
um o
f 15
min
utes
bef
ore
retu
rnin
g to
nor
mal
ope
ratio
n.
Sile
nt O
pera
tion
This
func
tion
allo
ws
you
to p
rogr
am p
erio
ds w
here
the
unit
will
oper
ate
with
redu
ced
nois
e le
vels
, per
fect
for
nigh
t tim
e an
d an
uni
nter
rupt
ed s
leep
.
Auto
mat
ic
Ope
ratio
n
This
func
tion
auto
mat
ical
ly s
elec
ts th
e re
quire
d he
atin
g or
coo
ling
func
tion
base
d on
the
curre
nt ro
om
cond
ition
s.
Wee
kly
Tim
erSe
t you
r uni
t to
turn
on
and
off a
utom
atic
ally
on
a w
eekl
y ba
sis
to s
uit y
our u
sual
room
usa
ge o
n ea
ch
day.
Slee
p Ti
mer
This
func
tion
allo
ws
you
to s
et a
pre
-det
erm
ined
am
ount
of t
ime
betw
een
30 a
nd 2
40 m
ins
that
you
r uni
t w
ill op
erat
e fo
r bef
ore
switc
hing
off.
Peak
-Cut
Tim
er*
Thi
s fu
nctio
n le
ts y
ou to
pre
set t
he c
apac
ity li
mit
durin
g ce
rtain
per
iods
of t
he d
ay, m
inim
isin
g en
ergy
co
nsum
ptio
n du
ring
peak
billi
ng ti
mes
, thu
s re
duci
ng
oper
atio
n co
sts.
Func
tion
Switc
h*
From
the
six
avai
labl
e fu
nctio
ns o
n th
e un
it, th
is
func
tion
allo
ws
you
to s
et tw
o fu
nctio
ns to
ope
rate
au
tom
atic
ally.
(Not
e: th
is is
not
ava
ilabl
e w
hen
a ce
ntra
lised
rem
ote
cont
rol i
s co
nnec
ted)
.
ENERGY SAVING
AIRFLOW CLEAN AIR
COMFORT & CONVENIENCE
MAINTENANCE
*Fun
ctio
ns c
an o
nly
be e
nabl
ed u
sing
the
RC
-EX3
wire
d co
ntro
ller
Opt
iona
l
21
![Page 22: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/22.jpg)
FDUA
SER
IES
FDUA
CAPA
CITY
7.1
KW10
.0 K
W10
.0 K
W10
.0 K
W12
.5 K
W14
.0 K
W12
.5 K
W14
KW
16 K
W20
KW
Set
FDU
A71A
VNXA
VFFD
UA1
00VN
P1VF
2FD
UA1
00AV
NVF
2FD
UA1
00AV
NXV
F2FD
UA1
25AV
NXV
FFD
UA1
40AV
NXV
FFD
UA1
25VS
XVF
FDU
A140
AVSX
VFFD
UA1
60AV
SAVF
FDU
A200
AVSA
VG
Indo
orFD
UA7
1VF
FDU
A100
VF2
FDU
A100
VF2
FDU
A100
VF2
FDU
A125
VFFD
UA1
40VF
FDU
A125
VFFD
UA1
40VF
FDU
A160
VFFD
UA2
00VG
Out
door
FDC
A71V
NXA
FDC
100V
NP
FDC
A100
VNFD
CA1
00VN
XFD
CA1
25VN
XFD
CA1
40VN
XFD
C12
5VSX
FDC
A140
VSX
FDC
A160
VSA
FDC
A200
VSA
Pow
er S
uppl
yO
utdo
or U
nit
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
3 Ph
ase
415V
50H
z3
Phas
e 41
5V 5
0Hz
3 Ph
ase
415V
50H
z3
Phas
e 41
5V 5
0Hz
Cap
acity
Coo
ling
T1kW
7.1
(3.2
-8.0
)10
.0 (2
.8-1
1.2)
10.0
(4.0
-11.
2)10
.0 (4
.0-1
1.2)
12.5
(5.0
-14.
0)14
.0 (5
.0-1
4.5)
12.5
(5.0
- 14
.0)
14.0
(5.0
-14.
5)16
.0 (6
.9-2
0.0)
20.0
(6.9
-28.
0)
Hea
ting
H1
8.0
(3.6
-9.0
)11
.2 (2
.5-1
2.5)
11.2
(4.0
-12.
5)11
.2 (4
.0-1
2.5)
14.0
(4.0
-17.
0)16
.0 (4
.0-1
8.0)
14.0
(4.0
- 17.
0)16
.0 (4
.0-1
8.0)
18.0
(5.5
-22.
4)22
.4(5
.5-3
1.5)
Inpu
tC
oolin
g T1
kW2.
222.
993.
052.
853.
834.
443.
834.
444.
836.
03
Hea
ting
H1
2.22
2.88
2.87
2.74
3.68
4.41
3.68
4.44
4.66
5.5
EER
Coo
ling
T13.
203.
343.
283.
513.
263.
153.
263.
153.
313.
32
CO
PH
eatin
g H
13.
603.
893.
904.
093.
803.
633.
83.
63.
864.
07
Soun
d Pr
essu
re L
evel
(J
S C
9612
)
Indo
orP-
Hi:3
8 H
i:33
Me:
29 L
o:25
P-H
i:43
Hi:4
2 M
e:40
Lo
:37
P-H
i:43
Hi:4
2 M
e:40
Lo
:37
P-H
i:43
Hi:4
2 M
e:40
Lo
:37
P-H
i:45
Hi:4
3 M
e:41
Lo
:37
P-H
i:47
Hi:4
6 M
e:43
Lo
:40
P-H
i : 4
7 H
i : 4
6 M
e : 4
3 Lo
: 40
P-H
i:47
Hi:4
6 M
e:43
Lo
:40
P-H
i:49
Hi:4
8 M
e:45
Lo
:42
P-H
i:52
Hi:5
0 M
e:47
Lo
:45
Out
door
5157
4948
4849
4849
5959
Soun
d Po
wer
Lev
el
(JS
C96
12)
Out
door
6670
7070
7072
7070
7373
Airfl
owIn
door
I/sP-
Hi:
400
Hi:
317
Me:
250
Lo:
167
P-H
i:650
Hi:6
00
Me:
550
Lo:4
83P-
Hi:6
50 H
i:600
M
e:55
0 Lo
:483
P-H
i:650
Hi:6
00
Me:
550
Lo:4
83P-
Hi:7
17 H
i:650
M
e:60
0 Lo
:500
P-H
i:850
Hi:8
00
Me:
700
Lo:6
00P-
Hi:7
17 H
i:650
M
e:60
0 Lo
:500
P-H
i:850
Hi:8
00
Me:
700
Lo:6
00P-
Hi:8
50 H
i:800
M
e:70
0 Lo
:600
P-H
i:133
3 H
i:120
0 M
e:10
67 L
o:93
3
Exte
rnal
Sta
tic P
ress
ure
Ps20
020
020
020
020
020
020
020
020
020
0
Exte
rnal
Dim
ensi
ons
(HXW
XD)
Indo
orm
m28
0x95
0x63
539
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5039
8x11
50x6
5037
9x16
00x8
93
Out
door
750x
880(
+88)
x340
845x
970x
370
845x
970x
370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1505
x970
x370
1505
x970
x370
Net
Wei
ght
Indo
orKg
3452
5252
5252
5252
5289
Out
door
6070
8110
510
510
510
510
514
314
3
Ref
riger
ant P
ipin
g
Liqu
id L
ine
mm
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø12
.7Ø
12.7
Gas
Lin
eØ
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
22.2
2 , Ø
25.4
or
Ø28
.58*
Ø22
.22
, Ø25
.4 o
r Ø
28.5
8*
Con
nect
ion
Met
hod
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Liqu
id: F
lare
/ G
as:
Braz
ing
Liqu
id: F
lare
/ G
as:
Braz
ing
Ref
riger
ant R
410A
Qua
ntity
Kg2.
952.
553.
84.
54.
54.
54.
54.
57.
27.
2
Pre
Cha
rged
To
Pipe
Len
gth
m30
1530
3030
3030
3030
30
Max
imum
Pip
e Le
ngth
m50
3050
100
100
100
100
100
70*
70*
Supp
ly A
ir C
onne
ctio
nm
m17
0x88
034
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
825
0x14
50
Ret
urn
Air C
onne
ctio
nm
m20
0x74
034
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
834
8x89
825
0x14
50
Con
trolle
rR
C-E
5, R
C-E
X3 o
r RC
N-K
IT4-
E2
Safe
ty P
enU
A-SP
1-E
(Opt
iona
l)U
A-SP
2-E
(Opt
iona
l)U
A-SP
2-E
(O
ptio
nal)
UA-
SP2-
E (O
ptio
nal)
UA-
SP2-
E
(Opt
iona
l)U
A-SP
2-E
(O
ptio
nal)
UA-
SP2-
E
(Opt
iona
l)U
A-SP
2-E
(O
ptio
nal)
UA-
SP2-
E
(Opt
iona
l)N
A
FDUA
71VF
FDUA
100-
160V
FFD
C100
VNP/
FDC
A100
VN
FDUA
200V
GFD
CA10
0-14
0VN
X, F
DC12
5VSX
, FD
CA14
0VSX
FDCA
71VN
XA
FDCA
160-
200V
SA
PROD
UCT
SPEC
IFIC
ATIO
NS
* Ref
er to
tech
nica
l man
ual
22
![Page 23: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/23.jpg)
FDUM
CAPA
CITY
5.0
KW5.
6 KW
7.1
KW10
.0 K
W10
.0 K
W12
.5 K
W14
.0 K
W12
.5 K
W14
.0 K
WSe
tFD
UM50
ZMXA
VFFD
UM60
ZMXA
VFFD
UM71
AVN
XAVF
1FD
UM
100V
NP1
VF2
FDU
M10
0AVN
VF2
FDU
M12
5AVN
XVF
FDU
M14
0AVN
XVF
FDU
M12
5VSX
VFFD
UM
140A
VSXV
F
Indo
orFD
UM
50VF
FDU
M60
VFFD
UM
71VF
1FD
UM
100V
F2FD
UM
100V
F2FD
UM
125V
FFD
UM
140V
FFD
UM
125V
FFD
UM
140V
F
Out
door
SRC
50ZM
XA-S
SRC
60ZM
XA-S
FDC
A71V
NXA
FDC
100V
NP
FDC
A100
VNFD
CA1
25VN
XFD
CA1
40VN
XFD
C12
5VSX
FDC
A140
VSX
Pow
er S
uppl
yO
utdo
or U
nit
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z3
Phas
e 41
5V 5
0Hz
3 Ph
ase
415V
50H
z
Cap
acity
Coo
ling
T1
kW
5.0
(2.2
-5.6
)5.
6 (2
.8-6
.3)
7.1
(3.2
-8.0
)10
.0 (2
.8-1
1.2)
10.0
(4.0
-11.
2)12
.5 (5
.0-1
4.0)
14.0
(5.0
-14.
5)12
.5 (5
.0-1
4.0)
14.0
(5.0
-16.
0)
Hea
ting
H1
5.4
(0.6
-6.3
)6.
7 (0
.6-7
.1)
8.0
(3.6
-9.0
)11
.2 (2
.5-1
2.5)
11.2
(4.0
-12.
5)14
.0 (4
.0-1
6.0)
16.0
(4.0
-16.
5)14
.0 (4
.0-1
8.0)
16.0
(4.0
-20.
0)
Hea
ting
H2
4.3
4.9
7.0
8.3
11.4
13.7
14.3
16.2
NA
Inpu
tC
oolin
g T1
kW1.
561.
752.
203.
002.
923.
604.
403.
604.
40
Hea
ting
H1
1.70
2.00
2.20
2.93
3.20
3.90
4.54
3.90
4.54
EER
Coo
ling
T13.
213.
203.
233.
333.
423.
473.
183.
473.
18
CO
PH
eatin
g H
13.
183.
353.
643.
823.
503.
593.
523.
593.
52
Soun
d Pr
essu
re L
evel
(J
S C
9612
)
Indo
or
dB(A
)
P-H
i:37
Hi:3
2 M
e:29
Lo
:26
P-H
i:36
Hi:3
1 M
e:28
Lo
:25
P-H
i:38
Hi:3
3 M
e:29
Lo
:25
P-H
i:44
Hi:3
8 M
e:36
Lo
:30
P-H
i:44
Hi:3
8 M
e:36
Lo
:30
P-H
i:45
Hi:4
0 M
e:34
Lo
:29
P-H
i:47
Hi:4
0 M
e:35
Lo
:30
P-H
i : 4
7 H
i : 4
0 M
e :
35 L
o : 3
0P-
Hi:4
7 H
i:40
Me:
35
Lo:3
0
Out
door
5054
5157
4950
4948
49
Soun
d Po
wer
Lev
el
(JS
C96
12)
Out
door
6364
6670
7070
7270
70
Airfl
owIn
door
I/sP-
Hi:
217
Hi:
167
Me:
15
0 Lo
: 133
P-H
i:333
Hi:2
50
Me:
217
Lo:1
67P-
Hi:
400
Hi:
316
Me:
25
0 Lo
: 166
P-H
i:600
Hi:4
67
Me:
417
Lo:3
17P-
Hi:
600
Hi:
467
Me:
41
7 Lo
: 317
P-H
i:650
Hi:5
33
Me:
433
Lo:3
33P-
Hi:8
00 H
i:583
M
e:46
7 Lo
:367
P-H
i:650
Hi:5
33
Me:
433
Lo:3
33P-
Hi:8
00 H
i:583
M
e:46
7 Lo
:367
Exte
rnal
Sta
tic P
ress
ure
Pa10
010
010
010
010
010
010
010
010
0
Exte
rnal
Dim
ensi
ons
(HXW
XD)
Indo
orm
m28
0x75
0x63
528
0x95
0x63
528
0x95
0x63
528
0x13
70x7
4028
0x13
70x7
4028
0x13
70x7
4028
0x13
70x7
4028
0x13
70x7
4028
0x13
70x7
40
Out
door
640x
800(
+71)
x290
640x
800(
+71)
x290
750x
880(
+88)
x340
845x
970x
370
845x
970x
370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
Net
Wei
ght
Indo
orKg
2934
3454
5454
5454
54
Out
door
4545
6070
8110
510
510
510
5
Ref
riger
ant P
ipin
g
Liqu
id L
ine
mm
Ø6.
35Ø
6.35
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52
Gas
Lin
eØ
12.7
Ø12
.7Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8
Con
nect
ion
Met
hod
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
n
Ref
riger
ant R
410A
Qua
ntity
Kg1.
51.
52.
952.
553.
84.
54.
54.
54.
5
Pre
Cha
rged
To
Pipe
Len
gth
m15
1530
1530
3030
3030
Max
imum
Pip
e Le
ngth
m30
3050
3050
100
100
100
100
Supp
ly A
ir C
onne
ctio
nm
m17
0x68
017
0x88
017
0x88
017
0 x
1200
170
x 12
0017
0 x
1200
170
x 12
0017
0 x
1200
170
x 12
00
Ret
urn
Air C
onne
ctio
nm
m20
0x66
020
0x86
020
0x86
023
5 x
1280
235
x 12
8023
5 x
1280
235
x 12
8023
5 x
1280
235
x 12
80
Con
trolle
rR
C-E
5, R
C-E
X3 o
r RC
N-K
IT4-
E2
FDUM
SER
IES
PROD
UCT
SPEC
IFIC
ATIO
NS
FDUM
50-1
40VF
,FD
C100
VNP/
FDC
A100
VN
SRC5
0-60
ZMXA
-S
FDC1
25VS
X, F
DCA1
40VS
XFD
CA71
VNXA
23
![Page 24: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/24.jpg)
FDT
FDTC
FDTC
& F
DTCA
PACI
TY5.
0 KW
Set
FDTC
50ZM
XAVF
Indo
orFD
TC50
VF
Out
door
SRC
50ZM
XA-S
Pow
er S
uppl
yO
utdo
or U
nit
1 Ph
ase
230V
50H
z
Cap
acity
Coo
ling
T1
kW
5.0(
1.1-
5.6)
Hea
ting
H1
5.4
(0.6
-6.3
)
Hea
ting
H2
5.1
Inpu
tC
oolin
g T1
kW1.
56
Hea
ting
H1
1.45
EER
Coo
ling
T13.
20
CO
PH
eatin
g H
13.
72
Soun
d Pr
essu
re L
evel
(J
S C
9612
)
Indo
or
dB(A
)
P-H
i:47
Hi:4
2 M
e:36
Lo
:30
Out
door
54
Soun
d Po
wer
Lev
el
(JS
C96
12)
Out
door
63
Airfl
owIn
door
I/sP-
Hi:
225
Hi:
191
Me:
15
0 Lo
: 133
Pane
lTC
-PSA
-25W
-E
Exte
rnal
Dim
ensi
ons
(HXW
XD)
Pane
l
mm
35x7
00x7
00
Indo
or24
8x57
0x57
0
Out
door
640x
800(
+71)
x290
Net
Wei
ght
Indo
orKg
Uni
t 15
Pane
l 3.5
Out
door
45
Ref
riger
ant P
ipin
g
Liqu
id L
ine
mm
Ø6.
35
Gas
Lin
eØ
12.7
Con
nect
ion
Met
hod
Flar
e co
nnec
tion
Ref
riger
ant R
410A
Qua
ntity
Kg1.
5
Pre
Cha
rged
To
Pipe
Len
gth
m15
Max
imum
Pip
e Le
ngth
m30
Con
trolle
rR
CH
-E3,
RC
-E5,
R
C-E
X3 o
r RC
N-T
C-
24W
-ER
5.6
KW7.
1 KW
10.0
KW
10.0
KW
12.5
KW
14.0
KW
12.5
KW
14.0
KW
FDT6
0ZM
XAVG
FDT7
1AVN
XAVG
FDT1
00AV
NVG
FDT1
00VN
PVG
FDT1
25AV
NXV
GFD
T140
AVN
XVG
FDT1
25VS
XVG
FDT1
40AV
SXVG
FDT6
0VG
FDT7
1VG
FDT1
00VG
FDT1
00VG
FDT1
25VG
FDT1
40VG
FDT1
25VG
FDT1
40VG
SRC
60ZM
XA-S
FDC
A71V
NXA
FDC
A100
VNFD
C10
0VN
PFD
CA1
25VN
XFD
CA1
40VN
XFD
C12
5VSX
FDC
A140
VSX
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
3 Ph
ase
415V
50H
z3
Phas
e 41
5V 5
0Hz
5.6
(1.1
-6.3
)7.
1 (3
.2-8
.0)
10.0
(4.0
-11.
2)10
.0 (2
.8-1
1.2)
12.5
(5.0
-14.
0)14
.0 (5
.0-1
6.0)
12.5
(5.0
-14.
0)14
.0 (5
.0-1
6.0)
6.7
(0.6
-7.1
)8.
0 (3
.6-9
.0)
11.2
(4.0
-12.
5)11
.2 (2
.5-1
2.5)
14.0
(4.0
-17.
0)16
.0 (4
.0-1
8.0)
14.0
(4.0
-18.
0)16
.0 (4
.0-2
0.0)
5.4
6.6
8.8
8.7
12.8
13.4
15.0
14.5
1.52
1.94
2.76
2.76
3.42
4.26
3.42
4.26
1.56
1.91
2.74
2.84
3.43
4.20
3.43
4.20
3.68
3.66
3.65
3.62
3.65
3.29
3.65
3.29
4.29
4.19
4.08
4.52
4.08
3.81
4.08
3.81
P-H
i:44
Hi:3
4 M
e:32
Lo
:28
P-H
i:46
Hi:3
5 M
e:34
Lo
:29
P-H
i:49
Hi:4
1 M
e:39
Lo
:32
P-H
i:51
Hi:4
0 M
e:37
Lo
:35
P-H
i:49
Hi:4
1 M
e:39
Lo
:32
P-H
i:49
Hi:4
2 M
e:39
Lo
:33
P-H
i : 4
9 H
i : 4
1 M
e :
39 L
o : 3
2P-
Hi:4
9 H
i:42
Me:
39
Lo:3
3
5251
4857
4849
4849
6566
7070
7072
7072
P-H
i: 43
3 H
i: 28
3 M
e:
233
Lo: 1
83P-
Hi:
467
Hi:
300
Me:
25
0 Lo
: 200
P-H
i: 61
6 H
i: 45
0 M
e:
400
Lo: 3
33P-
Hi:6
16 H
i:450
M
e:40
0 Lo
:333
P-H
i: 63
3 H
i: 46
7 M
e:
417
Lo: 3
00P-
Hi:
633
Hi:
483
Me:
43
3 Lo
: 317
P-H
i: 63
3 H
i: 46
7 M
e:
417
Lo: 3
00P-
Hi:
633
Hi:
483
Me:
43
3 Lo
: 317
T-PS
AE-5
AW-E
35x9
50x9
50 3
5x95
0x95
0 3
5x95
0x95
0 3
5x95
0x95
0 3
5x95
0x95
0 3
5x95
0x95
0 3
5x95
0x95
0 3
5x95
0x95
0
236x
840x
840
236x
840x
840
298x
840x
840
298x
840x
840
298x
840x
840
298x
840x
840
298x
840x
840
298x
840x
840
640x
800(
+71)
x290
750x
880(
+88)
x340
845x
970x
370
845x
970x
370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
Uni
t 21
Pane
l 5U
nit 2
1 Pa
nel 5
Uni
t 25
Pane
l 5U
nit 2
5 Pa
nel 5
Uni
t 25
Pane
l 5U
nit 2
5 Pa
nel 5
Uni
t 25
Pane
l 5U
nit 2
5 Pa
nel 5
4560
8170
105
105
105
105
Ø6.
35Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø12
.7Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
Flar
e co
nnec
tion
1.5
2.95
3.8
2.55
4.5
4.5
4.5
4.5
1530
3015
3030
3030
3050
5030
100
100
100
100
RC
H-E
3, R
C-E
5, R
C-E
X3 o
r RC
N-T
-5AW
-E2
FDTC
& F
DT
PROD
UCT
SPEC
IFIC
ATIO
NS
FDTC
50VF
FD
C100
VNP/
FDC
A100
VN
FDT6
0-14
0VG
FDC1
25VS
X, F
DCA1
40VS
XFD
CA71
VNXA
24
![Page 25: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/25.jpg)
FDE
CAPA
CITY
7.1
KW10
.0 K
W10
.0 K
W10
.0 K
W12
.5 K
W14
.0 K
W12
.5 K
W14
.0 K
WSe
tFD
E71A
VNXA
VGFD
E100
VNP1
VGFD
E100
AVN
VGFD
E100
AVN
XVG
FDE1
25AV
NXV
GFD
E140
AVN
XVG
FDE1
25VS
XVG
FDE1
40AV
SXVG
Indo
orFD
E71V
GFD
E100
VGFD
E100
VGFD
E100
VGFD
E125
VGFD
E140
VGFD
E125
VGFD
E140
VG
Out
door
FDC
A71V
NXA
FDC
100V
NP
FDC
A100
VNFD
CA1
00VN
XFD
CA1
25VN
XFD
CA1
40VN
XFD
C12
5VSX
FDC
A140
VSX
Pow
er S
uppl
yO
utdo
or U
nit
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
1 Ph
ase
230V
50H
z1
Phas
e 23
0V 5
0Hz
3 Ph
ase
415V
50H
z3
Phas
e 41
5V 5
0Hz
Cap
acity
Coo
ling
T1
kW
7.1
(4.0
-8.0
)10
.0 (2
.8-1
1.2)
10.0
(4.0
-11.
2)10
.0 (4
.0-1
1.2)
12.5
(5.0
-14.
0)14
.0 (5
.0-1
6.0)
12.5
(5.0
-14.
0)14
.0 (5
.0-1
6.0)
Hea
ting
H1
8.0
(3.6
-9.0
)11
.2 (2
.5-1
2.5)
11.2
(4.0
-12.
5)11
.2 (4
.0-1
2.5)
14.0
(4.0
-17.
0)16
.0 (4
.0-1
8.0)
14.0
(4.0
-18.
0)16
.0 (4
.0-2
0.0)
Hea
ting
H2
7.0
8.1
9.5
12.6
13.2
13.5
14.6
15
Inpu
tC
oolin
g T1
kW2.
112.
662.
852.
553.
504.
403.
614.
40
Hea
ting
H1
2.11
2.94
2.9
2.68
3.77
4.69
3.78
4.69
EER
Coo
ling
T13.
363.
763.
513.
923.
573.
183.
463.
18
CO
PH
eatin
g H
13.
793.
813.
864.
183.
713.
413.
73.
41
Soun
d Pr
essu
re L
evel
(J
S C
9612
)
Indo
orP-
Hi:4
7 H
i:41
Me:
37
Lo:3
2P-
Hi:4
8 H
i:43
Me:
38
Lo:3
4P-
Hi:4
8 H
i:43
Me:
38
Lo:3
4P-
Hi:4
8 H
i:43
Me:
38
Lo:3
4P-
Hi:4
8 H
i:45
Me:
40
Lo:3
5P-
Hi:4
9 H
i:45
Me:
40
Lo:3
6P-
Hi :
48
Hi :
45
Me
: 40
Lo :
35P-
Hi:4
9 H
i:45
Me:
40
Lo:3
6
Out
door
5157
4948
4849
4849
Soun
d Po
wer
Lev
el
(JS
C96
12)
Out
door
6670
7070
7072
7072
Airfl
owIn
door
I/sP-
Hi:3
33 H
i:267
Me:
217
Lo:1
67P-
Hi:5
33 H
i:433
Me:
350
Lo:2
75P-
Hi:5
33 H
i:433
Me:
350
Lo
: 275
P-H
i:533
Hi:4
33 M
e: 3
50
Lo: 2
75P-
Hi:5
33 H
i:483
Me:
383
Lo
: 283
P-H
i:567
Hi:4
83 M
e: 3
83
Lo: 3
00P-
Hi:5
33 H
i:483
Me:
383
Lo
: 283
P-H
i:567
Hi:4
83 M
e: 3
83
Lo: 3
00
Exte
rnal
Dim
ensi
ons
(HXW
XD)
Indo
orm
m21
0x13
20x6
90 2
50x1
620x
690
250
x162
0x69
0 2
50x1
620x
690
250
x162
0x69
0 2
50x1
620x
690
250
x162
0x69
0 2
50x1
620x
690
Out
door
750x
880(
+88)
x340
845x
970x
370
845x
970x
370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
1300
x970
x370
Net
Wei
ght
Indo
orKg
3343
4343
4343
4343
Out
door
6070
8110
510
510
510
510
5
Ref
riger
ant P
ipin
g
Liqu
id L
ine
mm
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Ø9.
52Ø
9.52
Gas
Lin
eØ
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8Ø
15.8
8
Con
nect
ion
Met
hod
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Flar
e C
onne
ctio
nFl
are
Con
nect
ion
Ref
riger
ant R
410A
Qua
ntity
Kg2.
952.
553.
84.
54.
54.
54.
54.
5
Pre
Cha
rged
To
Pipe
Len
gth
m30
1530
3030
3030
30
Max
imum
Pip
e Le
ngth
m50
3050
100
100
100
100
100
Con
trolle
rR
C-E
5, R
C-E
X3, R
CH
-E3
or R
CN
-E-E
2
FDE
SERI
ESPR
ODUC
T SP
ECIF
ICAT
ION
S
FDE7
1-14
0VG
FDC1
00VN
P/ F
DCA1
00VN
FD
CA10
0-14
0VN
X, F
DC12
5VSX
, FD
CA14
0VSX
FDCA
71VN
XA
25
![Page 26: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/26.jpg)
(Su
spen
sion
bolts
pitc
h)
Cont
rol b
ox
C2
D
(Du
ct dim
ensio
n)
(Duct dimension)
(Suspension bolts pitch)
AB
susp
ensio
n bo
ltHa
nger
plat
e fo
r
AGa
s pipi
ngB
Liquid
pipi
ng
DHo
le fo
r wirin
gE
Susp
ensio
n bo
lts(
M10)
Sym
bol
Cont
ent
Drain
pipi
ng(
Grav
ity d
raina
ge)
φ9.
52(
3/8")(
Flar
e)φ
15.8
8(5/
8")(
Flar
e)
FIn
spec
tion
hole
(45
0X45
0)
Air s
upply
duc
t
E
(Duct dimension)
(Du
ct dim
ensio
n)
Under
Retu
rn a
ir du
ctDr
ain h
ose
piece
(Ac
cess
ory)
(In
stalle
d on
site)
C2C1Dr
ain p
iping
VP25(
I.D.2
5,O.
D.32)
VP20(
I.D.2
0,O.
D.26)
28 472 135
1895
018
986
5588
055
250
175105
467
471
510
635
3030
280
67
82
41
200 39
6574
018
5 58
43170
1560
413
600(Max. drain lift) or less
76
295~
325
284 69
C1
Unit:m
m
AGa
s pipi
ngB
Liquid
pipi
ng
DHo
le fo
r wirin
gE
Susp
ensio
n bo
lts(
M10)
Sym
bol
Cont
ent
Drain
pipi
ngC2
φ9.
52(
3/8")(
Flar
e)φ
15.8
8(5/
8")(
Flar
e)
FIn
spec
tion
hole
(45
0X45
0)
(Su
spen
sion
bolts
pitc
h)
Cont
rol b
ox
C2D
(Du
ct dim
ensio
n)
(Duct dimension
(Suspension bolts pitch)
AB
susp
ensio
n bo
ltHa
nger
plat
e fo
r
Air s
upply
duc
t
E(Duct dimension)
(Du
ct dim
ensio
n)
(Gr
avity
dra
inage
)
Under
C1Dr
ain p
iping
VP25(
I.D.2
5,O.
D.32)
VP25(
I.D.2
5,O.
D.32)
Retu
rn a
ir du
ctDr
ain h
ose
piece
(Ac
cess
ory)
(In
stalle
d on
site)
28 472 150
17.5
1150
17.5
1185
111
898
181
370248172
506
498
531
650
4040
398
74
86
26348 24
111
898
181 61
24348
1560
458
600(Max. drain lift) or less
215
295-
325
284 69
C1
) A)
FDUA
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
INDO
OR U
NITS
FDUA
100V
F2IN
DOOR
UNI
TSFD
UA71
VF
26
![Page 27: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/27.jpg)
Unit:m
m
AGa
s pipi
ngB
Liquid
pipi
ng
DHo
le fo
r wirin
gE
Susp
ensio
n bo
lts(
M10)
Sym
bol
Cont
ent
Drain
pipi
ngC2
φ9.
52(
3/8")(
Flar
e)φ
15.8
8(5/
8")(
Flar
e)
FIn
spec
tion
hole
(45
0X45
0)
(Su
spen
sion
bolts
pitc
h)
Cont
rol b
ox
C2D
(Du
ct dim
ensio
n)
(Duct dimension)(Suspension bolts pitch)
AB
susp
ensio
n bo
ltHa
nger
plat
e fo
r
Air s
upply
duc
t
E
(Duct dimension)
(Du
ct dim
ensio
n)
(Gr
avity
dra
inage
)
Under
C1Dr
ain p
iping
VP25(
I.D.2
5,O.
D.32)
VP25(
I.D.2
5,O.
D.32)
Retu
rn a
ir du
ctDr
ain h
ose
piece
(Ac
cess
ory)
(In
stalle
d on
site)
28 472 150
17.5
1150
17.5
1185
111
898
181
370248172
506
498
531
650
4040
398
74
82
26348 24
111
898
181 61
24348
1560
458
600(Max. drain lift) or less
215
295~
325
284 69
C1
Unit:m
m
AGa
s pipi
ngB
Liquid
pipi
ng
DHo
le fo
r wirin
gE
Susp
ensio
n bo
lts(
M10)
Sym
bol
Cont
ent
Drain
pipi
ng(
Grav
ity d
raina
ge)
C2
φ9.
52(3/
8")(
Flar
e)φ
15.8
8(5/
8")(
Flar
e)*
FIn
spec
tion
hole
(45
0X45
0)
(Su
spen
sion b
olts p
itch)
Contr
ol bo
x
(Du
ct dim
ensio
n)
(Duct dimension)(Suspension bolts pitch)
Hang
er pl
ate fo
rsu
spen
sion b
olt
Air s
upply
duct
(Duct dimension)
(Du
ct dim
ensio
n)
Under
C1Dr
ain p
iping
VP25(
I.D.2
5,O.
D.32)
VP25(
I.D.2
5,O.
D.32)
Retur
n air d
uct
Drain
hose
piec
e(
Acce
ssor
y)(
Instal
led on
site)
28 472 150
17.5
1150
17.5
1185
11189
818
1
370248172
506
498
531
650
4040
398
74
86
26348 24
11189
818
1 61
24348
1560
458
600(Max. drain lift) or less
215
295~
325
284 69 C2
DAB
E
C 1*Ple
ase
refe
r to
the
inst
alla
tion
man
ual.
Be s
ure
to u
se th
e pi
ping
acc
esso
ries
that
co
me
with
the
indo
or a
nd o
utdo
or u
nits
.
FDUA
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
INDO
OR U
NITS
FD
UA16
0VF
INDO
OR U
NITS
FD
UA12
5VF,
FDUA
140V
F
27
![Page 28: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/28.jpg)
AGa
s pipi
ngB
Liquid
pipi
ng
DHo
le fo
r wirin
gE
Susp
ensio
n bo
ltsM
10
Sym
bol
Cont
ent
Drain
pipi
ng(
Grav
ity d
raina
ge)
C2
φ25
.4(1")(
Braz
ing)
FIn
spec
tion
hole
(45
0X45
0)
C1Dr
ain p
iping
VP25(
O.D.
32)
VP25(
O.D.
32)
(Suspension bolts pitch)
φ12
.7(1/
2")(
Braz
ing)
1600
85
50250(Duct dimension)
7514
50(Du
ct dim
ensio
n)75
Unit:m
m
486
579 539
133165
349
379
893
2525
1634(
Susp
ensio
n bolt
s pitc
h)17
17
31 831 3179
7514
50(Du
ct dim
ensio
n)75
Air s
upply
duct
Retur
n air d
uct
759
69
284
80
250(Duct dimension)506
600 or less(Max. drain lift)
295~
325
179
Contr
ol bo
x
Hang
er pl
ate fo
rsu
spen
sion b
olt
Drain
hose
piec
e(
Acce
ssor
y)(
Instal
led on
site)
50
D BA
C2
C1
E
FDUA
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
INDO
OR U
NITS
FD
UA20
0VG
28
![Page 29: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/29.jpg)
View
M
tappin
gscre
wsHo
lesfor
Retur
naird
uct
Drain
hose
piece
(Ac
cess
ory)
(Ins
talled
onsit
e)
Hole
tappin
gscre
wHo
lesfor
AGa
spipi
ngB
Liquid
piping
C1Dr
ainpip
ingVP
20(I.D
.20,O
.D.26
)Note
(2)
DHo
lefor
wirin
gE
Susp
ensio
nbolt
s(M
10)
FOu
tside
airop
ening
Airo
utlet
open
ingG
Symb
olCo
ntent φ
12.7(
1/2")
(Flar
e)
fordu
cting
fordu
cting
(φ15
0)(K
nock
out)
(φ12
5)(K
nock
out)
Drain
piping
C2(
Grav
itydr
ainag
e)VP
20(I.
D.20
,O.D
.26)
φ6.3
5(1/
4")(F
lare)
HIns
pecti
onho
le(4
50X4
50)
φ17
0
φ12
4
φ17
0
tappin
gscre
wsHo
lesfor
4-φ
4
(Su
spen
sionb
oltsp
itch)
Airs
upply
duct
Contr
olbo
x 600(Max.drainlift) orless
(Du
ctdim
ensio
n)
(Ductdimension)
4317028 472 135
1875
018
786
susp
ensio
nbolt
Hang
erpla
tefor
5568
055
76
6758
81284
152
262
41200 39
6566
065
139
90
46002
00246
200
31 170 31
12-φ
4280
467413
471
510
635
3030 105
175250
(Du
ctdim
ensio
n)
(Ductdimension)
69
295~
325
113
4-φ
4
Unit:m
m
1550
(Suspensionboltspitch)
FG
M
E
C 2
DA
1 C
BGF
Notes
(1)
Them
odel
name
label
isatt
ache
dont
helid
ofthe
contr
olbo
x.(2
)Pr
epar
ethe
conn
ectin
gsoc
ket(
VP20
)ons
ite.
FDUM
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
INDO
OR U
NITS
FD
UM50
VF
View
M
tappin
gscre
wsHo
lesfor
Retur
naird
uct
Drain
hose
piece
(Ac
cess
ory)
(Ins
talled
onsit
e)
tappin
gscre
wHo
lesfor
AGa
spipi
ngB
Liquid
piping
C1Dr
ainpip
ingVP
20(I.
D.20
,O.D
.26)N
ote(2
)
DHo
lefor
wirin
gE
Susp
ensio
nbolt
s(M
10)
FOu
tside
airop
ening
Airou
tleto
penin
gG
Symb
olCo
ntent
φ6.35
(1/4
")(Fla
re)
fordu
cting
fordu
ctingMo
del
6071
Drain
piping
C2(G
ravity
draina
ge)
VP20
(I.D.
20,O
.D.26
)
(φ15
0)(Kn
ocko
ut)
(φ12
5)(Kn
ocko
ut)
φ9.52
(3/8
")(Fla
re)φ1
2.7(1/2
")(Fla
re)φ
15.88
(5/8
")(Fla
re)
HIns
pecti
onho
le(4
50X4
50)
Hole
φ17
0
φ12
4
φ17
0
tappin
gscre
wsHo
lesfor
4-φ
4
(Su
spen
sionb
oltsp
itch)
Contr
olbo
x 600(Max.drainlift) orless
(Du
ctdim
ensio
n)
(Ductdimension)
(Suspensionboltspitch)
28 472 135
1895
018
986
susp
ensio
nbolt
Hang
erpla
tefor
5588
055
76
250175
105
467413
471
510
635
3030
280
67
81284
152
262
41200 39
6586
065
139
90
464×
200=
800
46
1307113
14-φ
4
58
113
Airs
upply
duct
295~
325
43170(Ductdimension)
(Du
ctdim
ensio
n)
69
4-φ
4
200
1550
M
C2
DA
C1
BGF
FG
E
Notes
(1)
Them
odel
name
label
isatt
ache
dont
helid
ofthe
contr
olbo
x.(2
)Pr
epar
ethe
conn
ectin
gsoc
ket(
VP20
)ons
ite.
INDO
OR U
NITS
FD
UM60
VF, F
DUM
71VF
29
![Page 30: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/30.jpg)
FDUM
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
View
M
tappin
g scre
wsHo
les fo
r
Retur
n air d
uct
Hole
tappin
g scre
wHo
les fo
r
φ9.5
2(3/
8")8F
lare)
φ15
.88(5
/8")
(Flar
e)
Drain
hose
piec
e(
Acce
ssor
y)(
Instal
led on
site)
φ17
0
φ12
4
φ17
0
tappin
g scre
wsHo
les fo
r 4-
φ4
(Su
spen
sion b
olts p
itch)
Air s
upply
duct
Contr
ol bo
x
(Du
ct dim
ensio
n)
(Duct dimension)
1813
6818
1404
susp
ensio
n bolt
Hang
er pl
ate fo
r
104
1200
104
92
250184.5134.5
467405
468
635
738
3030
280
71
59
81284
152
285
23.5235 21.5
6412
8064
139
□90
100
100
24.5 205 24.5
14-φ
4600(Max. drain lift)
(Suspension bolts pitch)
28 530 180
or less
4×28
0=11
20
113
69
43170(Duct dimension)
(Du
ct dim
ensio
n)
280
4-φ
4
1545
FG
M
C2
DAC1
BGF E
Unit:m
m
Note(
1)Th
e mod
el na
me la
bel is
attac
hed o
n the
lid of
the
contr
ol bo
x.
AGa
s pipi
ngB
Liquid
pipin
g
C1Dr
ain pi
ping
VP25(I.
D.25
, O.D
.32)
DHo
le for
wirin
gE
Susp
ensio
n bolt
s(M
10)
FOu
tside
air o
penin
g
Air o
utlet
open
ingG
Symb
olCo
ntent
for du
cting
for du
cting
(φ15
0)(K
nock
out)
(φ12
5)(K
nock
out)
Drain
pipin
gC2
(Gr
avity
drain
age)
VP20(I.
D.20
, O.D
.26)
HIns
pecti
on ho
le(4
50X4
50)
295‑
325
INDO
OR U
NITS
FD
UM10
0VF2
View
M
tappin
gscre
wsHo
lesfor
Retur
naird
uct
Hole
tappin
gscre
wHo
lesfor
AGa
spipi
ngB
Liquid
piping
C1Dr
ainpip
ingVP
20(I.D
.20,O
.D.26)
Note(
2)
DHo
lefor
wirin
gE
Susp
ensio
nbolt
s(M
10)
FOu
tside
airop
ening
Airo
utlet
open
ingG
Symb
olCo
ntent φ
9.52(
3/8")
8Flar
e)
fordu
cting
fordu
cting
Drain
piping
C2(
Grav
itydr
ainag
e)VP
20(I.
D.20
,O.D
.26)
φ15
.88(5/
8")(F
lare)
(φ15
0)(
Knoc
kout
)
(φ12
5)(
Knoc
kout
)
Drain
hose
piece
(Ac
cess
ory)
(Ins
talled
onsit
e)
HIns
pecti
onho
le(4
50X4
50)
φ17
0
φ12
4
φ17
0
tappin
gscre
wsHo
lesfor
4-φ
4
(Su
spen
sionb
oltsp
itch)
Airs
upply
duct
Contr
olbo
x
(Du
ctdim
ensio
n)
(Ductdimension)
1813
6818
1404
susp
ensio
nbolt
Hang
erpla
tefor
104
1200
104
92
250184.5134.5
467405
468
635
738
3030
280
71
59
81284
152
285
23.5235 21.5
6412
8064
139
90
100
100
24.5 205 24.5
14-φ
4
600(Max.drainlift)
(Suspensionboltspitch)28 530 180
orless
4×28
0=11
20
113
69
295~
325
43170(Ductdimension)
(Du
ctdim
ensio
n)
280
4-φ
4
1545
FG
M
C2
DAC1
BGF E
Unit:m
m
Notes(
1)Th
emod
elna
melab
elis
attac
hedo
nthe
lidof
theco
ntrol
box.
(2)
Prep
aret
heco
nnec
tings
ocke
t(VP
20)o
nsite
.
INDO
OR U
NITS
FD
UM12
5VF,
FDUM
140V
F
30
![Page 31: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/31.jpg)
FDTC
SER
IES
EXTE
RIOR
DIM
ENSI
ONS
G G
G
G
FC
AB
D
INDO
OR U
NITS
FD
TC50
VF
31
![Page 32: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/32.jpg)
FDT
SERI
ESEX
TERI
OR D
IMEN
SION
S
A
Conte
nt
Gas p
iping
BLiq
uid pi
ping
CDr
ain pi
ping
VP25
(O.D
.32)
DHo
le for
wirin
gF
Susp
ensio
n bolt
s(M
10 or
M8)
G
Obsta
cle
Make
a sp
ace o
f 500
0 or m
ore b
etwee
nthe
units
whe
n ins
tallin
g mor
e tha
n one
.
Deco
rativ
e pan
el
Hang
er pla
te for
susp
ensio
n bolt
(Max. Drain lift)
H1φ
125(
Knoc
k out)
Contr
ol bo
xAn
ti draf
t func
tion(
※1)
177
02
770ー
800
725
725ー
770
P1P2
Symb
ol
H2φ
200(
Knoc
k out)
Outsid
e air o
penin
gfor
ductin
gAir
outle
t ope
ning
for du
cting
or more
or mo
re
Contr
olbo
x
Susp
ensio
n bolt
s pitc
h:P1
(770
)
Suspension bolts pitch:P2(770)
(Ins
talled
on si
te)
Drain
hose
piec
e(A
cces
sory)
Hole
Holes
for
tappin
g scre
ws
Holes
for
tappin
g scre
ws
(Kno
ck ou
t)
Hole
Hole
Holes
for
tappin
g sc
rews
Air su
pply
Air re
turn g
rille
Note
s(1) T
he m
odel
nam
e la
bel is
atta
ched
to th
eco
ntro
l box
lid.
(2)S
uspe
nsio
n bo
lt pi
tch
P1,P
2 is
adju
stab
leby
a p
atte
rn o
f the
righ
t tab
le.
(3)S
ectio
n 1
(※1)
is p
rovid
ed o
n th
e pa
nel
T-PS
AE-5
AW-E
onl
y.
Patte
rnSy
mbol
Mode
l71
60φ
12.7(1
/2")(F
lare)φ
15.88(
5/8")(
Flare)
φ6.3
5(1/4
")(Flare
)φ9.5
2(3/8
")(Flare
)
1000
1000
□630
□950
860ー
910(
Ceilin
g hole
size
)
568420
420
245 30
333
3
50 or more140
188
□840
131173
236 35
512ー
542850 or less
88100
10060140
140
6-φ4
88100
130
240
140
6-φ4
200
76
112
137
67
5038
3740
65
5-φ4
105
4413
Unit:
mm
Spac
e fo
r ins
talla
tion
and
serv
ice
H1,2
G
H1,2
H1,2
BA
FC
H1H2
H1,2
D
G
Susp
ensio
n bolt
pitch
rang
e
INDO
OR U
NITS
FD
T60V
G, F
DT71
VG
Deco
rativ
e pan
el
Note
s(1) T
he m
odel
nam
e la
bel is
atta
ched
to th
e
con
trol b
ox lid
.
(2) S
uspe
nsio
n bo
lt pi
tch
P1,P
2 is
adju
stab
le
by
a pa
ttern
of t
he ri
ght t
able
.
(
3) S
ectio
n 1
(※1)
is p
rovid
ed o
n th
e pa
nel
T
-PSA
E-5A
W-E
onl
y.
Unit:
mm
Obsta
cle
Make
a sp
ace o
f 500
0 or m
ore b
etwee
nthe
units
whe
n ins
tallin
g mor
e tha
n one
.
or more
or mo
re10
00
1000
Spac
e fo
r ins
talla
tion
and
serv
ice
177
02
770ー
800
725
725ー
770
P1P2
Patte
rnSy
mbol
Susp
ensio
n bolt
pitch
rang
e
ACo
ntent
Gas p
iping
φ15
.88(5/
8")(Fla
re)B
Liquid
pipin
gφ
9.52(3
/8")(
Flare)
CDr
ain pi
ping
VP25(
O.D.
32)
DHo
le for
wirin
gF
Susp
ensio
n bolt
s(M
10 or
M8)
G
Hang
er pla
te for
susp
ensio
n bolt
(Max. Drain lift)
H1φ
125(K
nock
out)
Contr
ol bo
x
Symb
ol
H2φ
200(K
nock
out)
Outsi
de ai
r ope
ning
for du
cting
Air ou
tlet o
penin
gfor
ducti
ng
Contr
olbo
x
Susp
ensio
n bolt
s pitc
h:P1(7
70)
Suspension bolts pitch:P2(770)
(Ins
talled
on si
te)
Drain
hose
piec
e(A
cces
sory)
Hole
Holes
for
tappin
g scre
ws
Holes
for
tappin
g scre
ws
(Kno
ck ou
t)
Hole
Hole
Holes
for
tappin
g sc
rews
Air su
pply
Air re
turn g
rille
Anti d
raft fu
nctio
n(※1)
□630
□950
860ー
910(C
eiling
hole
size)
568420
420
245 30
333
3
50 or more140
188
□840
131173
298 35
512ー
542
850 or less
140100
10060140
140
6-φ4
140100
130
240
140
6-φ4
200
76
112
137
129
5038
9940
65
5-φ4
167
4413
H1,2
G
H1,2
H1,2
BA
FC
H1H2
H1,2
D
G
INDO
OR U
NITS
FD
T100
VG, F
DT12
5VG,
FDT
140V
G
32
![Page 33: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/33.jpg)
FDE
SERI
ESEX
TERI
OR D
IMEN
SION
S
C 2C 1
AB
AB
D
C 1,C
2
C 1,C
2
EG
F
INDO
OR U
NITS
FD
E71V
G
33
![Page 34: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/34.jpg)
FDE
SERI
ESEX
TERI
OR D
IMEN
SION
S
C 1,C
2
C 1,C
2
C 2C1
A
EG
F
AB
B
D
INDO
OR U
NITS
FD
E100
VG, F
DE12
5VG,
FDE
140V
G
34
![Page 35: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/35.jpg)
NOTES
35
![Page 36: PACKAGED AIR CONDITIONING SYSTEMS · heat exchanger in MHI outdoor units are coated with specially formulated ... THREE PHASE MODELS (12.5kW - 20.0kW) Model lineup and product specifications](https://reader033.vdocuments.us/reader033/viewer/2022050314/5f7629b74a2ee80f43253cb4/html5/thumbnails/36.jpg)
For all sales enquires email:
Dealer
9C Commercial Road Kingsgrove NSW 2208PO Box 318 Kingsgrove NSW 1480Office: 02 8571 7977Hotline: 1300 138 007
2/15 Howleys Road Notting Hill VIC 3168Office: 03 9544 3400Hotline: 1300 138 007
NEW SOUTH WALES & ACT VICTORIA, SOUTH AUSTRALIA & TASMANIA
5/26 Flinders Parade, North Lakes QLD 4509PO Box 142, North Lakes QLD 4509Office: 07 3385 0334Hotline: 1300 138 007
12/31 Fleming Street, Aitkenvale, QLD 4814PO Box 1386, Aitkenvale, QLD, 4814Office: 07 4775 1169Hotline: 1300 138 007
QUEENSLAND & NORTHERN TERRITORY TOWNSVILLE
1/15-17 Capital Road, Malaga WA 6090 PO Box 2089, Malaga WA 6944Hotline: 1300 138 007
698A Great South Road, Penrose, 1061PO Box 112310, Penrose, 1642Office: 9525 3019Hotline: 0800 138 007
WESTERN AUSTRALIA NEW ZEALAND
MHIAA.COM.AUMHIAA.CO.NZ
Connect with MHIAA