  • 7/24/2019 OXO Admin Training Presentation

    1/67

    Alcatel OMNIPCX OFFICE

    TRAINING MATERIALS for ADMINISTRATORS

    Prepared by Dave Rebong

  • 7/24/2019 OXO Admin Training Presentation

    2/67

    Omni PCX Office

    Overview

    Architecture

    HardwareConfiguration

  • 7/24/2019 OXO Admin Training Presentation

    3/67

    OVERVIEW

  • 7/24/2019 OXO Admin Training Presentation

    4/67

    OVERVIEW

  • 7/24/2019 OXO Admin Training Presentation

    5/67

    ArchitectureTRADITIONALPABX

    Private AutomaticBranch ExchangePABX

    Analog

    Proprietary Phone

    Fax

  • 7/24/2019 OXO Admin Training Presentation

    6/67

    Architecture

    CONTINUESWIDE PHONE SECURITYINNOVATIONSTERMINAL PLATFORMS

    MOBILITY

    CONTACT UNIFIED SOLUTIONCENTER COMMUNICATION

    ADVANCED INTERNET APPLICATIONRICH HOTEL

    TELEPHONYACCESS OPENNESSFEATURES VOIP SERVICE Via XML

    Using Linux and the Wide ALCATEL Platform

  • 7/24/2019 OXO Admin Training Presentation

    7/67

    Architecture

    TOPHOLOGY Environment

  • 7/24/2019 OXO Admin Training Presentation

    8/67

    Cabinets

    BoardsHardware & Design

    Alcatel-Lucent Omni-PCX Office Compact Edition

    AND RACK S/M/L MODULES:

    Alcatel-Lucent Omni-PCX Office Compact Edition -

    - Alcatel-Lucent Omni-PCX Office Compact Edition is a wall-mountedversion - It provides 2 slots (1xCPU slot+1xMIX slot)

    -TThe Alcatel-Lucent Omni-PCX Office Compact Edition rack is not expandableand cannot be used as satellite

    12 ports1 CPU slot + 1 MIX slot

    Power consumption: 1.5 A (240 V)

    Dimensions: H = 345 mm; W = 370 mm; D = 65mm. Weight: 5.1 kg.

  • 7/24/2019 OXO Admin Training Presentation

    9/67

    Cabinets

    BoardsHardware & Design

    The following mixed boards areavailable:

    MIX 448

    MIX 484

    AMIX 444-1

    AMIX 484-1

    AMIX 448-1

  • 7/24/2019 OXO Admin Training Presentation

    10/67

    Cabinets

    BoardsHardware & Design

    RACK 1 (SMALL) or Small

    - The RACK S module (formerly known as RACK 1) mainly consists of a plastic frame -

    The plastic frame receives all the parts for attaching the power supply board, the

    fans, the battery and the mains power connector, and everything. -There is no

    backplane board: the metric connectors are on the power supply module. -19" rack

    modules which can be mounted in a rack or placed on a shelf - it has 3 slots 1 for CPU

    & 2 for card interfaces28 ports

    1 CPU slot + 2 general-purpose slots (no SLI16

    board) Power consumption: 1 A (230 V) / 2 A (110 V)

    - 80 W. Dimensions: H = 66 mm (2.6 inches);

    W = 442 mm (17,4 inches); D = 400 mm (15.76

    inches). Weight: 6 kg.

  • 7/24/2019 OXO Admin Training Presentation

    11/67

    Cabinets

    BoardsHardware & Design

    Hardware Assembly Details:

  • 7/24/2019 OXO Admin Training Presentation

    12/67

    Cabinets

    BoardsHardware & Design

    RACK M (MEDIUM) AND RACK L (LARGE)

    - The frame consists of a "U"-shaped sheath closed on the top by a riveted plate -The boards are guided by 2 rails for RACK M (formerly known as RACK 2), or 3 rails

    for RACK L (formerly known as RACK 3), riveted vertically to the frame.

    -The enclosure consists of a metal top part, two metal side parts and a plastic front face

    Access to the fans, the power supply module and the batteries is gained by

    disconnecting the power cable and unscrewing the backplane.-IIt has 6 Slots 1 for CPU & 5 for card interfaces

    56 ports

    1 CPU slot + 5 general-purpose slots

    Power consumption: 1.2 A (230 V) / 2.3 A (110 V)- 120W.

    Dimensions: H = 110 mm (4.3 inches);

    W = 442 mm (17.4 inches); D = 400 mm (15.76inches). Weight: 11 kg.

  • 7/24/2019 OXO Admin Training Presentation

    13/67

    Cabinets

    BoardsHardware & Design

    - 96 ports

    - 1 CPU slot + 4 specific general-purpose

    slots (no UAI16 and MIX boards)- Power consumption: 1.2 A (230 V) / 2.3 A (110 V) -150W. - Dimensions: H = 154 mm (6.1 inches)

    RACK L (LARGE) W = 442 mm (17.4 inches); D = 400 mm (15.76inches). -Weight: 13 kg.

    - It has 9 slots, 1 for CPU & 8 for card interfaces

    The Maximum capacity:

    -The system can be extended by adding oneor two modules to the main module

    -All combinations are possible, with a maximum of3 modules

    RACK XL (LARGE) -The maximum capacity is 236 stations.

    -It has MAX of 27 slots, 1 for CPU, 2 for MEX, & 24for card interfaces

  • 7/24/2019 OXO Admin Training Presentation

    14/67

    Cabinets

    BoardsHardware & Design

    Hardware Assembly Details:

  • 7/24/2019 OXO Admin Training Presentation

    15/67

    Cabinets

    BoardsCard, Modules & Interfaces

    CPU Overview & Migration History

    The CPU-1 board is based on the new tracking of the ASPEN CPU board and has thefollowing characteristics: 133 MHz processor, 32 MB NAND Flash, 64 MB SDRAM, DSP5410.

    The CPU-2board has the same main characteristics as the CPU-1 board, except that the32 MB NAND Flash memory is replaced by a 64 MB NAND Flash memory.

    The CPU-3 board has the following characteristics: 133 MHz processor, 128 MBNAND Flash, 64 MB SDRAM.

    The CPU-3m board is fitted with a 133 MHz processor, a 128 MB NAND Flash memoryand 64 MB of SDRAM.

    The CPU-4 board is fitted with a 133 MHz processor, a 128 MB NAND Flash memoryand 128 MB of SDRAM.

    The Latest CPU is POWERCPU

  • 7/24/2019 OXO Admin Training Presentation

    16/67

    Cabinets

    Boards

    Daughter Boards

    The CPU-1/CPU-2/CPU-3/CPU-3m/CPU-4 boards can be equipped with the following

    daughter boards:

    HSL (High Speed Link): module interconnections. This daughter board is notcompatible with the Mini-Mix daughter board.

    XMEM, XMEM-1, XMEM128-1 (eXpansion MEMory): memory extension. This

    daughter board is not compatible with the VoIP daughter board.This daughter board includes a 2.5" hard drive

    connector: Use a flat cable to connect a PATA harddiskUse a P2SATA-AXV daughter board to connect a SATA hard disk

    AFU, AFU-1 (Auxiliary Function Unit): supporting auxiliary functions such as general bell,

    door-phone, audio In, audio Out, etc. The AFU-1 board is required for the connection ofthe ISDN-EFM box (T0/S0 forwarding)

    VoIP, VoIP-1 (Voice over IP): Gateway H.323 with integrated Gatekeeper function or

    SIP Gateway. Supports management of CODECs and DSPs for IP telephony and IP

    Trunk (IP trunk lines) applications

  • 7/24/2019 OXO Admin Training Presentation

    17/67

    Cabinets

    BoardsCard, Modules & Interfaces CPU-4

    CPU Module

    VOIP or XMEM card

    CPU Module

    SATA HD ConnectorProcessor

    High Speed Link AFU -x

    Mix Connector

  • 7/24/2019 OXO Admin Training Presentation

    18/67

    Cabinets

    BoardsCard, Modules & Interfaces CPU-4

    Available functions:

    -LAN: 10/100 base T Ethernet port (MDI-II/straight)

    - AUDIO-OUT: loudspeaker, alarm and general bell interfaces; 12V output -

    AUDIO-IN: please-wait message and background music interfaces -DOORPHONE: door phone interfaces- CONFIG: RS232 for MMC, NMC and PPP connections

    - MODULE1: HSL link to add-on module 1 (if HSL daughter board present) - MODULE2: HSL link to add-on

    module 2 (if HSL daughter board present) - ISDN T0 1: T0 access 1 if Mini-Mix daughter board present

    (CPU-3m or CPU-4 only) - ISDN T0 2: T0 access 2 if Mini-Mix daughter board present (CPU-3m or CPU-4

    only) - SLI1/2: access to analog terminals 1 and 2 (if Mini-Mix daughter board present on CPU-3m or CPU-

    4)

  • 7/24/2019 OXO Admin Training Presentation

    19/67

    Cabinets

    BoardsCard, Modules & Interfaces CPU-4

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    20/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPU

    The Power CPU board, based on processor Power Quicc II Pro MPC8377

    from Free scale, has the following characteristics:

    -667 MHz processor, 256 MB DDR2 SDRAM, SD/MMC Memory card(2GB), -VoIP DSP C6421/4 (16 VoIP channels).

    The Power CPU board is built around 2 main blocks interconnected viaPCI:

    -CPU part with MPC8377 processor and following interfaces:

    DDR 2 memory

    BOOT (NOR Flash) Serial ATA for Hard Disk

    SD card controller PCI

    LAN interfacesI2C

  • 7/24/2019 OXO Admin Training Presentation

    21/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPU

    -Telecom part with INOX ASIC and with connections to:

    Telecom DSP

    Modem DSPVoIP DSP

    Legacy Telecom architecture (PCM buses, ASL, HSL)

    Daughter Boards

    The POWER CPU boards can be equipped with the following daughter boards:

    HSL (High Speed Link): module interconnections. This daughter board isnot compatible with the Mini-Mix daughter board.

    ARMADA 16 -Gateway H.323 with integrated Gatekeeper function or SIPGateway. Supports management of CODECs and DSPs for IP telephony and IP

    Trunk (IP trunk lines) applications

  • 7/24/2019 OXO Admin Training Presentation

    22/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPU

    AFU-1 (Auxiliary Function Unit): supporting auxiliary functions such as general bell,

    door- phone, audio In, audio Out, etc. The AFU-1 board is required for the connection of

    the ISDN-EFM box (T0/S0 forwarding)

    MINI-MIX - Supports a combination of 2 SLI ports or 1 SO & 1 TO, or 1 SLI & 1 TO

    SATEX RoHS board-connects the HD SATA to POWER CPU Module

  • 7/24/2019 OXO Admin Training Presentation

    23/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPU

    Power CPU Front Panel LEDs

    LED Indicators & meanings

  • 7/24/2019 OXO Admin Training Presentation

    24/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPU

    Output Port

    Available functions:

    - LAN: 10/100/1000 base T Ethernet port (MDI-II/straight).

    - SLI1/SLI2: Analog Z accesses from Mini-MIX board, General ringer; 12Voutput -AUX: General ringer; 12V output

    -- MODULE1: HSL1 link of HSL board for connection to module expansion1 - ISDN T01: ISDN T01 port of Mini-MIX board

    - MODULE2: HSL2 link of HSL board for connection to module expansion2 - ISDN T02: ISDN T02 port of Mini-MIX board

    - AUDIO: Interfaces Please wait message, Background music, Loudspeaker,Alarm - DOORPHONE: Interfaces doorphone

  • 7/24/2019 OXO Admin Training Presentation

    25/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER CPUPOWER CPU Front Panel

    Output Port

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    26/67

    Cabinets

    BoardsCard, Modules & Interfaces POWER MEX

    -The Power MEX board is a controller board for extension or module expansion.

    -The Power MEX board (POWER Module EXPANSION) performs the controllerfunctions in the expansion platforms.

    -The Power MEX board is equipped with an HSL1 (High Speed Link) boardfor interconnecting with the basic platform.

    - The Power MEX board is connected to the MODULE 1 or MODULE 2 connector

    on the Power CPU boardMeaning of the LED Indications

    MEX Front Panel

    RJ 45 PIN SOCKET ASSIGNMENT

    Figure 2.15: HSL1 Daughter Board on Power MEX Board

  • 7/24/2019 OXO Admin Training Presentation

    27/67

    Cabinets

    BoardsCard, Modules & Trunk cards BRA T0 ISDN card

    The BRA board The BRA(Basic Rate Access) board provides the basic access points (2 x

    64-Kbps B-channels + 1 x 16-Kbps D-channel per access) for connecting the system to theISDN digital public network (point-to-point or multipoint T0 link)starting with version

    R2.0,to a private network (point-to-point DLT0 link); 3 versions are offered:

    Types:

    - BRA2: 2 T0 accesses OUTPUT PORTS (FACEPLATE)

    - BRA4: 4 T0 accesses- BRA8: 8 T0 accesses

    Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    28/67

    Cabinets

    BoardsCard, Modules & Trunk cards PRI /E1 ISDN card

    The PRA board (Primary Rate Access) board provides 1 primary access for connecting the

    Alcatel-Lucent Omni-PCX Office Communication Server system to the ISDN digital publicnetwork or to private networks.

    Types:

    PRA -T2, DASS2, DLT2: 30 x 64-Kpbs B-channels + 1 x 64-Kbps D-channel; 2048

    KbpsPCM R2: 30 x 64 Kbps B-channels + 1 x 4 Kbps signaling channel; 2048 Kbps.

    OUTPUT PORTS (FACEPLATE)Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    29/67

    Cabinets

    BoardsCard, Modules & Interfaces PRI /E1 ISDN card

    T2 board example

    ALARM LEDS & Meanings

  • 7/24/2019 OXO Admin Training Presentation

    30/67

    Cabinets

    BoardsCard, Modules & Interfaces APA 4/8 card

    APA Boards

    This board is used to connect to the analog public network ( 4 or 8 ports).

    Types: OUTPUT PORTS (FACEPLATE)

    - APA 4- APA 8

    Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    31/67

    Cabinets

    BoardsCard, Modules & Interfaces SLI - xx-1

    The SLI, SLI-1 or SLI-2 board (Single Line) allows the connection of 2-wireanalog terminals (Z). 3 board versions are available:

    Types:OUTPUT PORTS (FACEPLATE)

    - SLI4: 4 Z interfaces -

    SLI8: 8 Z interfaces -

    SLI16: 16 Z interfaces

    Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    32/67

    Cabinets

    BoardsCard, Modules & Interfaces UAI - xx-1

    The UAI board allows the connection of digital stations (UA). The UAI-16 board

    allows to remotely supply the terminals connected to the 16 interfaces from a EPS48external power supply connected to interface 1 using an external adaptation power

    cable (splitter).

    Types:OUTPUT PORTS (FACEPLATE)

    - boards without external power supplycapability: UAI4: 4 UA interfaces

    UAI8: 8 UA interfaces UAI16: 16 UA interfaces

    - boards with external power supplycapability: UAI16-1: 16 UA interfaces

    Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    33/67

    Cabinets

    BoardsCard, Modules & Interfaces AMIX x/x/x-1

    The AMIX-1 (Analog Mixed Line) board is used to connect the analog publicnetwork (PSTN) to the PBX. It has the following characteristics:

    - 4 analog line accesses

    - a maximum of 8 UAinterfaces - a maximum of 8 Zinterfaces- an OBC system interface supporting AT, Z and UAsignaling - protection features

    OUTPUT PORTS (FACEPLATE)Types:

    AMIX 4/8/4 -1 AMIX 4/4/8 -1AMIX 4/4/4 -1

    RJ 45 PIN SOCKET ASSIGNMENT

    Connection Diagram:

    SAME as other modules

  • 7/24/2019 OXO Admin Training Presentation

    34/67

    Cabinets

    BoardsCard, Modules & Interfaces LANX -1

    The LAN X board (Ethernet LAN Switch) serves to connect Ethernet terminals (IEEE 802.3 compatible)

    3 board versions are available:

    - LanX8 = 810/100 BT Ethernet ports (ports 1 to 7: MDI-X/crossover; Uplink: MDI-II/straight link) -LanX16 = 16 10/100 BT Ethernet ports (ports 1 to 15: MDI-X/crossover; Uplink: MDI-II/straight link) -

    LANX16-1 = 16 10/100 BT Ethernet ports (ports 1 to 15: MDI-X/crossover; Uplink: MDI-II/straight link);

    low consumption. Contrary to the LANX8 and LANX16 boards that are seen by the system as CPU

    boards,-Green LED (left) = link status and activity:LED off: link disconnected

    LED steady: link connected

    LED flashing: link active -

    Yellow LED (right) = speed:

    off: low speed (10 or 100 Mb for Gigabit port, 10 Mb for the other ports) on: high speed (1 Gb for Gigabit port, 100 Mb for the other ports)

    Connection Diagram

    RJ 45 PIN SOCKET ASSIGNMENT

  • 7/24/2019 OXO Admin Training Presentation

    35/67

    SYSTEM Programming / Configuration/ OMC

    Alcatel OMNI-PCX OFFICE -Can be configure easy. By Default the SYSTEM is alreadypre-configured via the ALCATEL Lucent. The OXO System has its General

    Characteristic:All CARDS / Modules are all HOT swappable (excluding CPU & MEX modules)

    OXO automatically creates in the System Profile the cards/modules that are in-place at system usable slots.

    Upon System Prep-up the PH version is loaded via LOLA tool or ex-factory configuration.

    Used ONLY OMC tool for System configuration.

    TELNET is not Support for OXO system.

    Default IP address is 192.168.92.246/24

    OXO System interface on configuration are via IP, V.24, & z modem

    All System configuration/ CDB files are stored at OXO HD or NAND FLASH or can be

    stored at your PC as CBD files for back-up purposes.

  • 7/24/2019 OXO Admin Training Presentation

    36/67

    SYSTEM Programming / Configuration/ OMC

    Starter for System programming:

    GENERAL REQUIREMENTS

    +CONNECT

    OXO SystemPC OMC Software

  • 7/24/2019 OXO Admin Training Presentation

    37/67

    SYSTEM Programming / Configuration/ OMC

    OMC overview -A thick client software proprietary to OXO systems, which can be use to

    fully manage the OXO system. Install the package application on your PC, used Windows

    platforms such as XP Pro, SP1, SP2, & SP3, MS Server 2003, SP1 & SP2, or WIN7 SP1.

    OMC LEVELS -There are 3 OMC access to the OXO Systems:

    - Operator Access- Administrator Access- Installer Access

    OMC Passwords -Each Levels are protected w/ unique passwords. These password

    can be change depending on your requirement. Below are thedefault passwords:

    - Operator Access = help1954 -Administrator Access= kilo1987

  • 7/24/2019 OXO Admin Training Presentation

    38/67

    SYSTEM Programming / Configuration/ OMC

    HOW TO CONNECT

    Assuming that OMC was already installed follow the step procedures

    Launch OMC, Select Connectto PCX

    ModificationTypical PressOKStep 2 Select LAN, Fill the IP @ of

    Step 1OXO, & PressOK

    Step 3

    kilo1987 Select ADMINISTRATOR

    Enter correct password & PressOKStep 4

  • 7/24/2019 OXO Admin Training Presentation

    39/67

    SYSTEM Programming / Configuration/ OMC

    Accessing the Main Menu

    Assuming that PMC is logged-in successfully, the administrator should see the ff menus:

    Subscriber- Use the this menu for modifying pre-programmed profiles of All Extensions.

    GROUP - For modifying Operator Groups, Hunting Groups & Pickup groups. System- Basic

    modifications for System Date & Time, Numbering Plans, System software key Common SD -

    for Add/delete & edit of Company Speed Dials/ Directory & Class grouping External Access -

    Displays the current setting for External lines & edits of trunk groups.

  • 7/24/2019 OXO Admin Training Presentation

    40/67

    SYSTEM Programming / Configuration/ OMC/ Subscriber

    BASIC Subscriber Menu

  • 7/24/2019 OXO Admin Training Presentation

    41/67

    SYSTEM Programming / Configuration/ OMC/ Subscriber

    BASIC Subscriber Menu

    Int. No. = Display/edit the Internal Extension Number of an Extension for OXOusers Pub. No. = Display/edit the Public DID number of an Extension for OXO

    users. NAME = Display/edit/delete the Names Spelling of a user

    SET TYPES = Display only the Model or Phone type assigned to a

    User. REST. = Display/modify barring setting of a User Extension

    Accessible Trunk Groups = Display/edit/delete trunk group access code to a given

    user/s Call Distributions = 2ndpage under BASIC Subscriber Menu that display

    information & routing status between external lines & subscribers. Distribution lists

    may be display/edit/delete.

    Rest/barring = A submenu of BASIC Subscriber Menu that contains number prefixes thateither to be allowed or restricted to the use of a user.

    Advanced = A submenu of BASIC Subscriber Menu that re-direct the administrator tothe more deeper configuration for users extension.

    Apply, OK, Cancel - for Validation or cancelation of any modification.

  • 7/24/2019 OXO Admin Training Presentation

    42/67

    SYSTEM Programming / Configuration/ OMC/Subscriber/Call Dist.

    Basic Call Distribution via External Lines

  • 7/24/2019 OXO Admin Training Presentation

    43/67

    SYSTEM Programming / Configuration/ OMC

    Basic Call Barring table of prefixes & rights

    Apply

  • 7/24/2019 OXO Admin Training Presentation

    44/67

    SYSTEM Programming via OMC\ADVANCED USER CONFIG

    USER ADVANCED PROGRAMMINGCLICK ADVANCEDAdd a non Physical portsTo navigate on this

    Areas to edit the for a User via IP, DECT,

    OMC Page basic USER parameters Virtual users.

    To apply all modified

    Item at this page menu

    PhysicalGo to deeper & editAddress

    in Details the userOf a Portconfiguration

    ExtensionUse to delete user

    NumberMailbox immediately

    Assigned to Name of a user,Phone set

    A User Used by Dial By NameModel assigned

    featuresto a user

  • 7/24/2019 OXO Admin Training Presentation

    45/67

    SYSTEM Programming / Configuration/ OMC/Subscriber

    CLICK DETAILSKEY

    To navigate on this

    OMC Page

    Detailed

    Configuration

    Of a user

    Apply

  • 7/24/2019 OXO Admin Training Presentation

    46/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK GROUPSICON

    To navigate on this

    OMC Page

    Select, edit,

    Add, Delete Select, edit, Select, edit, Add, DeleteEntries or members Add, Delete Entries or membersOf an Operator group Entries or members Select, edit, Of a Pickup GroupsThere are 8 groups: Of a User Group/s

    Add, Delete There are 16 groups that1 for Default Group There are 30 groups thatEntries or members can be created, each1 for Opening Hours Can be created, from 540Of a Paging Groups group has 16 members1 for Restricted Hours Up to 570, each group hasThere are 8 groups thatEach group has 8 16 membersCan be created, each group hasmembers32 members

  • 7/24/2019 OXO Admin Training Presentation

    47/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK GROUPSICON

    To navigate on this

    OMC Page

    Attendant GROUPS

    Select, edit,

    Add, Delete

    Entries or members Of

    an Operator groupThere are 8 groups: 1

    for Default Group 1 for

    Opening Hours 1 for

    Restricted Hours Each

    group has 8 members

  • 7/24/2019 OXO Admin Training Presentation

    48/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK AttendantGroups

    To navigate on this

    OMC Page

    Use this area toModifyparameters

    Apply

  • 7/24/2019 OXO Admin Training Presentation

    49/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    HUNTING GROUPS

    Select, edit,

    Add, Delete

    Entries or membersOf a User Group/s

    There are 30 groups that

    Can be created, from 540

    Up to 570, each group has

    16 members

  • 7/24/2019 OXO Admin Training Presentation

    50/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK HUNTINGGroups

    To navigate on this

    OMC Page

    Use this area toModifyparameters

    Apply

    / / /

  • 7/24/2019 OXO Admin Training Presentation

    51/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    BROADCAST GROUPS

    Select, edit,

    Add, Delete

    Entries or members Of a

    Paging Groups There are

    8 groups that

    Can be created, each group has32 members

    / f / /

  • 7/24/2019 OXO Admin Training Presentation

    52/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK BROODCASTGroups

    To navigate on this

    OMC Page

    Use this area toModifyparameters

    Apply

    i / fi i / /

  • 7/24/2019 OXO Admin Training Presentation

    53/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    PICKUP GROUPS

    Select, edit, Add, Delete

    Entries or members Of a

    Pickup Groups There are

    16 groups that can be

    created, each group has

    16 members

    SYSTEM P i / C fi i / OMC/GROUPS

  • 7/24/2019 OXO Admin Training Presentation

    54/67

    SYSTEM Programming / Configuration/ OMC/GROUPS

    CLICK PICKUPGroups

    To navigate on this

    OMC Page

    Use this area toModifyparameters

    Apply

    SYSTEM P i / C fi ti / OMC/SYSTEMS

  • 7/24/2019 OXO Admin Training Presentation

    55/67

    SYSTEM Programming / Configuration/ OMC/SYSTEMS

    CLICK GROUPSICON

    To navigate on this

    OMC Page

    Numbering Plans

    Select, edit,

    Add, Delete

    Entries or members Of

    an Operator groupThere are 8 groups: 1

    for Default Group 1 for

    Opening Hours 1 for

    Restricted Hours Each

    group has 8 members

    SYSTEM P i / C fi ti / OMC/SYSTEMS

  • 7/24/2019 OXO Admin Training Presentation

    56/67

    SYSTEM Programming / Configuration/ OMC/SYSTEMS

    CLICK DialingPlans

    To navigate on this

    OMC Page

    Use this to

    Select numberformats

    Select to NavigateOn advanced

    Numbering PlanApplyConfiguration

    SYSTEM P i / C fi ti / OMC/SYSTEMS

  • 7/24/2019 OXO Admin Training Presentation

    57/67

    SYSTEM Programming / Configuration/ OMC/SYSTEMS

    CLICK

    To navigate on this

    OMC Page

    Used by Numbering PlansSame as Internal Numbering PlansUsed byExternal callers, Intended for PBXNumbering Plan, For Private PABXInternalTELCO, Networks Features while inUsed during NetworkingUsers of theTo reach internal Restricted hours conversationPCX SystemUsers via AA or DID

    SYSTEM P i / C fi ti / OMC/SWK

  • 7/24/2019 OXO Admin Training Presentation

    58/67

    SYSTEM Programming / Configuration/ OMC/SWK

    CLICK

    To navigate on this Software KEYS

    OMC Page

    Actual CPU ID

    Actual SoftwareKey Codes

    To view the actual

    Active features via

    License unlock

    Apply

    SYSTEM Programming / Configuration/ OMC/SWK

  • 7/24/2019 OXO Admin Training Presentation

    59/67

    SYSTEM Programming / Configuration/ OMC/SWK

    CLICK

    To navigate on thisOMC Page

    On These Screen Menu , the SYSTEM will allow you to VIEW all the ActiveLicenses of the Omni-PCX Office.

    Each TABs are Comprise of licenses that applies to a group or specific features

    & Application.

    Values indicated on TABs are not to modify. These are dependent on SWK

    SYSTEM Programming / Configuration/ OMC/CSD

  • 7/24/2019 OXO Admin Training Presentation

    60/67

    SYSTEM Programming / Configuration/ OMC/CSD

    CLICK the SPEED DIAL ICON

    To navigate on this

    OMC Page

    Add, Remove, Edit w/

    Numbers & Names for

    Each Speed dial entries

    Click here to go to

    Advance configurationApply

    Validate & Apply any

    Modification for BASIC

    MENU

    SYSTEM Programming / Configuration/ OMC/CSD

  • 7/24/2019 OXO Admin Training Presentation

    61/67

    SYSTEM Programming / Configuration/ OMC/CSD

    CLICK

    To navigate on this Common Speed Dials

    OMC Page

    Right Click & Apply

    SYSTEM Programming / Configuration/ OMC/External Access

  • 7/24/2019 OXO Admin Training Presentation

    62/67

    SYSTEM Programming / Configuration/ OMC/External Access

    CLICK ExternalAccesses

    To navigate on this

    OMC Page

    Add, Remove, Edit the

    Trunk Groups & DISA

    Activation for eachLine access

    Apply

    SYSTEM BACK / RESTORE via OMC

  • 7/24/2019 OXO Admin Training Presentation

    63/67

    SYSTEM BACK / RESTORE via OMC

    Starter for System Backup / Restore

    GENERAL REQUIREMENTS

    CONNECT

    DATA TRANSFER

    OXO SystemPC w/ RESTOREOMC

    SYSTEM Programming / Configuration/ OMC

  • 7/24/2019 OXO Admin Training Presentation

    64/67

    SYSTEM Programming / Configuration/ OMC

    HOW TO BACKUP/RESTORE

    Assuming that OMC is already connected ONLINE at OXO

    Step 1

    Step 2

    SYSTEM Programming / Configuration/ OMC

  • 7/24/2019 OXO Admin Training Presentation

    65/67

    SYSTEM Programming / Configuration/ OMC

    DATA TRANSFER from OXO to PC

    Select the item to backup

    Use to select detail coin target backup or restore

    DATA transfer is going on

    Step 3

    Step 4

    SYSTEM Programming / Configuration/ OMC

  • 7/24/2019 OXO Admin Training Presentation

    66/67

    SYSTEM Programming / Configuration/ OMC

    Client database saveas

    Assuming that DATA transfer was already done

    Click Saveastab at File Menu

    Define device name

    Or Customer IDDefine Client

    Database Name

    Saved Database on your PC

    Disconnect Access to the system

  • 7/24/2019 OXO Admin Training Presentation

    67/67

    End of Document