SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
REVISIONS:
01SCALE: N.T.S. IMAGERY MAY NOT CORRECTLY INDICATE CURRENT POTENTIAL SHADING OF PROPERTY.
PARCEL - (AHJ PROPERTY APPRAISER)SCALE: NTS - http://www.s-5.com
S5 STANDING SEAM MOUNTING CLAMP
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATICDRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.
03SCALE: NTS. - STEEL, 1.5" MECHANICALLY SEAMED PANEL
MIAMI DADE APPROVED ROOFING, NOA 11-1202.03
CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S I
NT
ELL
EC
TU
AL
PR
OP
ER
TY
WH
ICH
BE
LON
GS
TO
ALL
EN
GE
ZE
LMA
N P
E.
•A
CC
ES
S I
S G
IVE
N T
O T
HE
IN
FO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H I
T I
S I
NT
EN
DE
D.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ES
S,
WR
ITT
EN,
PE
RM
ISS
ION
OF
ALL
EN
GE
ZE
LMA
N P
E
ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC
C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC
C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF
OWNER:
Address 115 S ANDREWS AVE RM 326 FORT LAUDERDALE FL 33301
BROWARD COUNTY, BOARD OF COUNTY COMMISSIONERS THIS PLAN IS ONLINE FOR REVIEW @C
ON
TA
CT
DE
SIG
N T
EA
M @
ww
w.G
eze
lma
nP
E.c
om
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM
www.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE FBC2007
W/09 SUPP. AND NATIONALELECTRICAL CODE.
AD
MIN
IST
RA
TIV
E B
UID
LIN
G ,
IN
ST
ALL
AT
ION
OF
A
SPEED: 140 MPH
EXPOSURE: C
IP CATEGORY: II
UPLIFT(PSF) : PZ1-32; PZ2-55.8; PZ3-82.5_PSF
ASCE PRESSURE ZONES:
HTTP://UNIRAC.COM/PDF/II227.PDFCO
DE
VE
RIF
YDESIGNED PER: ASCE 7-05, 2010 NEC,FBC2007 W/09 SUPP.
AHJ: BROWARD COUNTY, P ID# 4842 17 00 0010
TR
AD
EW
IND
S P
AR
K
NOTES FOR INSTALLATION OF SDHW (SOLAR DOMESTIC HOT WATER) COLLECTORS ON STANDING SEAM METAL ROOF:
THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY USERS (SOLAR INSTALLERS AND INSPECTOR
FOR AHJ, AUTHORITY HAVING JURISDICTION). THIS PLAN IS ALSO ONLINE FOR CONVENIENCE OF PLAN REVIEWER AND OTHERS WHO WISH TO
VIEW SUPPLEMENTARY INFORMATION AND STUDY PLAN AT INCREASED MAGNIFICATION. ALL USERS ARE WELCOME TO ACCESS EV
(ELECTRONIC VERSION) OF THIS PLAN. ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS
VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR
BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, THIS PLAN SHALL PREVAIL.
SUBJECT SOLAR COLLECTORS ARE FSEC APPROVED. S-5 CLAMPS ARE WIDELY USED FOR ATTACHMENT OF EXTERNAL EQUIPMENT TO STANDING
SEAM METAL ROOFS. S-5 OEM INFORMATION IS AVAILABLE BY HYPERLINK HTTP://WWW.S-5.COM/HOME/INDEX.CFM
S-5 T-CLAMPS ARE SHOWN IN THE DRAWING ON THIS PLAN. HOWEVER, CONTRACTOR IS FREE TO CHOOSE THE S-5 VERSION CONTRACTOR
BELIEVES TO BEST FIT THE STANDING SEAM PROFILE OF THE BUILDING. SET SCREWS OF S-5S SHALL BE TORQUED TO 115 INCH-POUNDS.
EACH COLLECTOR SHALL BE ATTACHED TO STANDING SEAM ROOF AT FOUR LOCATIONS USING OEM MOUNTING HARDWARE SHOWN ON THIS
PLAN. CONTRACTOR MAY USE EITHER FIXED OR HINGED AT HIS OPTION. COLLECTORS ARE SHOWN IN THIS PLAN LONG AXIS VERTICAL.
HOWEVER, CONTRACTOR IS FREE TO INSTALL COLLECTRORS LONG AXIS HORIZONTAL IF HE SO CHOOSES.
CONTRACTOR IS FREE TO SELECT THE SOLAR PLUMBING ARRANGEMENT OF HIS PREFERENCE FROM
OEM INSTRUCTIONS OR ALTERNATE PLUMBING METHODS DRAWING
HTTP://WWW.GEZELMANPE.COM/GENERIC/P.1.1.PDF
WHICH APPEARS AS PAGE 2 OF THIS TWO SHEET PLAN.
EOR (ENGINEER OF RECORD) MAY BE CONTACTED WITH QUESTIONS - [email protected] OR 813 909 1956.
INSTALLATION LOCATION
WIN
D
06SCALE: 3/16" = 1'-0"
ROOF LAYOUT PLAN
02
CONTRACTOR:
ZAGER PLUMBING & SOLAR, INC.149 SE 4TH STREETDEERFIELD BEACH, FL. 334411-800-870-6321
954-481-2629 / FAX 954-481-1654
CVC 56804 // CFC 041677
COLLECTOR: SOLENE SLAR-32, SRCC OG-100, FSEC# 00472N
36
00
W S
AM
PLE
RO
AD
, C
OC
ON
UT
CR
EE
K,
FL
33
07
3
INSTALLATION LOCATION2 SOLENE COLLECTORS
04SCALE: NTS
SOLAR THERMAL COLLECTOR05
SCALE: 1" = 1'-0"
COLLECTOR MOUNTING DETAIL
OEM MOUNTING BRACKET OEM MOUNTING HARDWARE
PLUMBING DETAILS
ALTERNATE SYSTEM TANK PLUMBING DETAILS.
SCOPE OF WORK: SOLAR SYSTEM COLLECTOR:
MODEL: ALL
SHEET NO:
DATE:
SOLAR WATER HEATER
REVISION NO./DATE:
SHEET NAME:
ALLEN GEZELMAN
16502 HANNA RD.
LUTZ, FLORIDA 33549
PH. 813 650 7246
FX. 866 397 [email protected]
DRAWN:
APPLICABLE CODE:
FLORIDA 2007 CODE W/09 SUPP
THIS SHEET IS A SUPPLAMETAL
PUMBING DETAIL SHEET
CHECKED:SB AG
C
OP
YR
IGH
T &
INT
ELL
EC
TU
AL
PR
OP
ER
TY
NO
TIC
E
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S I
NT
ELL
EC
TU
AL
PR
OP
ER
TY
WH
ICH
BE
LON
GS
TO
ALL
EN
GE
ZE
LMA
N P
E.
•A
CC
ES
S I
S G
IVE
N T
O T
HE
IN
FO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H I
T I
S I
NT
EN
DE
D.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ES
S,
WR
ITT
EN,
PE
RM
ISS
ION
OF
ALL
EN
GE
ZE
LMA
N P
E
EXPLANATORY INSTRUCTION:
THIS DRAWING IS INTENDED TO PROVIDE PLUMBING DETAILS FOR OEM SOLAR HOT WATER SYSTEMS NOT SHOWN ONOEM, PERMIT-READY, SOLAR DOMESTIC HOT WATER PLAN. THAT PLAN SHOWS THE PLUMBING DETAILS FOR OEM'SMOST COMMON SYSTEM “DIRECT” WHICH DETAILS ARE THEREFORE NOT REPEATED ON THIS “ALTERNATE SYSTEM
PLUMBING DETAILS” DRAWING.
04SCALE: N.T.S.
GENERIC MULTIPLE TANK INSTALLATION
TANK ALTERNATE PLUMBING SHEET:
THIS PLAN SHEET SHOWS THE VARIOUS TANK ALTERNATE PLUMBING ARRANGEMENTS FOR SOLAR WORLD SOLARDOMESTIC HOT WATER SYSTEMS - EXCLUDING THE STANDARD DIRECT SYSTEM WHICH IS SHOWN ON THE
COLLECTOR/SYSTEM INSTALLATION SHEETS A.1.0 AND A1.1. AND THEREFORE NOT DUPLICATED ON THIS TANK
ALTERNATE PLUMBING SHEET. CONTRACTORS, INSPECTORS, AHJS, AND OTHERS ARE CAUTIONED THAT LATITUDE ISALLOWED, E.G. A PARTICULAR SYSTEM PLUMBING MAY APPEAR SLIGHTLY DIFFERENT FROM WHAT IS SHOWN HEREAND STILL BE ACCEPTABLE SO LONG AS THE HYDRAULICS WORK THE SAME AS ONE OR THE OTHER OF THEARRANGEMENTS SHOWN N THIS SHEET.
02SCALE: N.T.S.
DRAIN BACK SYSTEM INSTALLATION03
SCALE: N.T.S.
CLOSED LOOP SYSTEM INSTALLTION01
SCALE: N.T.S.
DHW RETROFIT STANDARD TANK INSTALLATION
INSTALLATION INSTRUCTIONS:
1) REMOVE ALL PIPING FROM TOP OF THE EXISTING WATER HEATER
2) INSTALL ARRANGEMENT SHOWN AT THE MIDDLE TANK HOLE #2
A. MATERIALS NEEDED:
● DI-ELECTRIC NIPPLE ● 4" LONG DIP TUBE ● 34" FFC TEE ● 34" T&P W/8" STEM ● 34" MALE
ADAPTER ● 34" PIPE ABOUT 24" LONG.
B. PRE SOLDER MALE ADAPTER TO ONE END OF THE 34" PIPE AND THE TEE TO THE OTHER
END OF THE TUBE, LET COOL. CUT 24" TUBE IN HALF.
C. INSTALL DI-ELECTRIC NIPPLE ONTO THE TANK & INSERT THE 4" DIP TUBE INTO THE NIPPLE.
D. INSTALL TEE ASSEMBLY FROM STEP 1 ONTO NIPPLE.
E. INSTALL T&P INTO THE TEE AND T&P DRAIN PIPE
F. NOTE: FFC = FEMALE THREAD X FEMAL THREAD X COPPER
3) INSTALL ARRANGEMENT SHOWN AT THE LEFT TANK HOLE#1
A. MATERIALS NEEDED:
● DI-ELECTRIC NIPPLE ● A PLAIN NO HOLES DIP TUBE
B. INSTALL THE 34" DI-ELECTRIC NIPPLE.
C. CUT THE DIP TUBE TO PROPER LENGTH, ABOUT 12" FROM TANK BOTTOM, BUT NEVER LESS
THAN ONE FOOT BELOW TOP ELEMENT, INSTALL IN NIPPLE.
D. CONNECT THE PREFABRICATED FROM COLLECTOR ASSEMBLY SUPPLIED IN THE
"DREAM PACKAGE" BOX.
4) INSTALL ARRANGEMENT SHOWN AT THE RIGHT TANK HOLE#3
A. MATERIALS NEEDED:
● DI-ELECTRIC NIPPLE ● 12" MALE ADAPTER ● 34X
12X
34 FFC TEE ●PLAIN NO HOLES DIP TUBE ●
34X3"
PIECE OF COPPER TUBING
B. PRE SOLDER THE 12" MALE ADAPTER TO THE TO SOLAR (PUMP ASSEMBLY), AND PRE
SOLDER THE 34"X3" LG. COPPER PIPE TO TEE, LET COOL.
C. INSTALL PLAIN DIP TUBE AFTER CUTTING TO PROPER LENGTH, ABOUT 6" OFF TANK
BOTTOM.
D. SCREW BOTH PIECES TO THE NIPPLE, AFTER INSTALLING NIPPLE TO TANK TOP. POINT
TEE ASSEMBLY TO BACK OF TANK, PUMP ASSEMBLY TO TANK FRONT. FINISH THE COLD
WATER HOOK UP BY WRAPPING A WET RAG AROUND THE 3" COPPER TUBE WHEN SOLDERING
TO PREVENT OVERHEATING OF THE DIP TUBE.
INSTRUCTIONS
DIAGRAM
NOTE: IF THE HOUSE IS PLUMBED IN CPVC THEN TRANSITION TO COPPER BEFORE THE CITY WATER
SUPPLY SHUT OFF VALVE. MAKE SURE TO USE TEFLON TAPE ON ALL THREADED CONNECTIONS.
IF THE EXISTING TANK HAS A SIDE MOUNTED T&P, FOLLOW THE SAME INSTRUCTIONS AS LISTED IN
THE FIRST SECTION ABOVE. MAKE SURE AN EXPANSION TANK AND PROPER SIZED COLLECTORS ARE
USED TO REDUCE THE PROBABILITY OF OVERHEATING/BURSTING PLASTIC PIPING.
NOTE: PROPER SENSOR LOCATION AND INSTALLATION: REMOVE LOWER ELEMENTCOVER , WEDGE
SENSOR TIGHTLY TO TANK WALL AT ELEMENT OPENING AFTER THOROUGHLY CLEANING AND HEAT
SINKING THE SENSOR AND TANK WALL. INSULATE THOROUGHLY.
DIAGRAM DIAGRAM
INSTRUCTIONS INSTRUCTIONS
INSTALLATION NOTES: DRAIN BACK
DRAIN BACK TANK NEED NOT BE CO-LOCATED AT THE SOLAR TANK. DRAIN BACK TANK CAN BE LOCATED IN THE
ATTIC WITHIN REASONABLE DISTANCE OF SOLAR TANK (30-FEET ONE-WAY SHOULD BE CONSIDERED A
MAXIMUM)
A WIDE VARIETY OF HEAT TRANSFER FLUIDS MAY BE USED. WATER IS THE NORM. HOWEVER, FOOD GRADE
ANTI-FREEZE IS AN ACCEPTABLE ALTERNATE (AMONG OTHERS) .
FILL THE DRAIN BACK TANK UNTIL THE HEAT TRANSFER FLUID SHOWS AT THE TOP END OF THE VIEW TUBE.
THE FREEZE RECIRCULATION MODE IS TURNED “OFF” IN THE ELECTRONIC PUMP CONTROLLER.
BOTH PUMPS RUN AT THE SAME TIME.
CLOSED LOOP CHARGING INSTRUCTIONS
FOOD GRADE ANTI-FREEZE (AVAILABLE FROM COMMERCIAL REFRIGERATION PARTS HOUSES) IS THE ONLY HEAT
TRANSFER FLUID ACCEPTABLE.
A SEPARATE PUMP AND “CHARGING BUCKET” ARE NEEDED.
THE CLOSED LOOP WILL HOLD 2-PLUS GALLONS.
THE CHARGING BUCKET SHOULD HAVE A NIPPLE AT THE BOTTOM WITH A VALVE AND THE CHARGING PUMP.
THE CHARGING PUMP SHOULD CONNECT TO THE UPPER CHARGING VALVE ON THE CLOSED LOOP WITH A
WASHER CONNECTION HOSE.
THE BALL VALVE ON THE CLOSED LOOP SHOULD BE CLOSED.
THE LOWER CHARGING VALVE SHOULD BE PARTIALLY CLOSED AND HAVE A WASHER HOSE CONNECTED TO IT
WITH THE OTHER END OF THE WASHER SUPPLY HOSE DROPPED INTO THE CHARGING BUCKET .
USE THE SOLAR PUMP TO ASSIST IN FILLING THE CLOSED LOOP. OPEN THE VALVE AT THE BOTTOM OF THE
CHARGING BUCKET AND TURN ON BOTH THE CHARGING PUMP AND THE SOLAR PUMP.
PUMP FLUID THRU THE CLOSED LOOP UNTIL AIR STOPS COMING OUT OF THE LOWER CHARGING VALVE. THEN
CLOSE THE LOWER CHARGING VALVE AND TURN OFF BOTH PUMPS.
SWAP HOSES. THE HOSE FROM THE UPPER CHARGING VALVE SHOULD DROP INTO THE CHARGING BUCKET.
THE HOSE FROM THE CHARGING PUMP SHOULD NOW CONNECT TO THE LOWER CHARGING VALVE.
OPEN THE BALL VALVE.
START THE CHARGING PUMP, OPEN THE LOWER CHARGING VALVE AND “CRACK” THE UPPER CHARGING VALVE.
WHEN STEADY FLUID WITH NO AIR IS COMING OUT OF THE UPPER CHARGING VALVE, CLOSE THE CHARGING
VALVES AND TURN OFF THE CHARGING PUMP.
THE FREEZE RECIRCULATION MODE IS TURNED “OFF” IN THE ELECTRONIC PUMP CONTROLLER.
GENERAL NOTES:
BRASS NIPPLES MAY BE USED IN PLACE OF DI-ELECTRIC NIPPLES.
VALVES SHOWN ARE THE MINIMUM. CONTRACTOR IS FREE TO ADD ADDITIONAL VALVES AT PLACES OF HIS CHOOSINGSUCH AS ABOVE PUMP TO ENABLE SWAPPING WITHOUT HAVING TO DRAIN SOLAR.
NOTE:
NUMBER OF TANKS AND SIZE DETERMINED BY SQUARE FOOTAGE OF SOLAR COLLECTOR. SIZING SHOULD USETHE GENERAL RULE OF THUMB, “2-GALLONS OF STORAGE PER SQUARE FOOT OF COLLECTOR”.
FULL LENGTH DIP TUBE ON INLETS.
NO DIP TUBE ON OUTLETS.
FULL LENGTH DIP TUBE ON COLLECTOR FEED. (MAY BE BY TEE OFF COLD INLET)
½-LENGTH DIP TUBE ON COLLECTOR RETURN.
ELECTRIC BACK UP HOOKED UP IN THE LAST TANK IN THE CHAIN WHICH FEEDS HOT WATER TO THE BUILDINGONLY.
DIAGRAM
INSTRUCTIONS
THIS IS THE ONLY ONE OF MY MANY PLANS WHICH I ALLOW TO BE PLACED AS ‘PLAN ON FILE’
WITH BUILDING DEPARTMENTS – I WILL PROVIDE A SEALED AUTHORIZATION LETTER – IF
REQUESTED FOR A SPECIFIC BUILDING DEPARTMENT
STARDARD DETAILS WHICH MAY BE PLACED ON FILE WITH AHJS
ENLARGED VIEWING & HYPERLINKS:
PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS.
ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK
ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT:
WWW.CADVICE.US/SW/P.1.1.PDF
5/12/2011 6:10 PM
P.1.1.dwg
CONTRACTOR:
ZAGER PLUMBING & SOLAR, INC.
149 SE 4TH STREET
DEERFIELD BEACH, FL. 33441
1-800-870-6321
954-481-2629 / FAX 954-481-1654
CVC 56804 // CFC 041677