oregon state university (osu) · elevator. the only elevator in building is designated as a freight...

277
OREGON STATE UNIVERSITY (OSU) PHARMACY BUILDING ADA ASSESSMENT & SURVEY

Upload: others

Post on 21-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OR

EG

ON

STA

TE U

NIV

ER

SIT

Y (

OSU

)

PHARMACY BUILDING

ADA ASSESSMENT & SURVEY

ADA ON-CALL CONSULTING

Page 2: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

Sacramento Office 770 L Street, Suite 950 Sacramento, CA 95814 Tel: 916.669.8750 Fax: 888.211.7441 Silicon Valley Office 2225 E. Bayshore Road, Suite 200 Palo Alto CA 94303 Tel: 866.694.7637 www.szs-consulting.com

April 13, 2016

GABRIEL MERRELL ASSOCIATE DIRECTOR AND DEPUTY ADA COORDINATOR OFFICE OF EQUAL OPPORTUNITY AND ACCESS OREGON STATE UNIVERSITY 330 SNELL HALL CORVALLIS, OR 97331

Re: ADA Accessibility Survey and Assessment – Pharmacy Building Dear Gabriel, We are pleased to submit this report for the Pharmacy Building. This report is part of our project to provide a Campus Accessibility Survey and Assessment for Oregon State University. It is our hope that this report will assist OSU in improving access to people with disabilities to campus facilities. SZS has been pleased to be a part of this effort to evaluate campus buildings using federal and state statutes and regulations, as well as universal design principles in order to create performance standards that will guide design, construction and maintenance on campus. We look forward to discussing our findings with your team. Regards,

Syroun Z. Sanossian, Principal SZS Consulting Group LLC

Page 3: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

TABLE OF CONTENTS

1. EXECUTIVE SUMMARY OF FINDINGS p. 1

a. Pedestrian Facilities and Exterior Spaces Analyzed p. 2

b. Building Entrances p. 3

2. INTERIOR SPACES

Basement p. 4

First Floor p. 5

Second – Sixth Floors p. 5

3. BARRIER DATA RECORDS Exterior Area Barriers p. 7

Interior Area Barriers p. 25

Cost Estimate p. 271

Page 4: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

1

1. EXECUTIVE SUMMARY OF FINDINGS

The field investigation for the interior spaces began on October 30, 2015. The exterior site elements were assessed originally as part of the pedestrian facilities assessment in June- September 2011 and are included as an essential part of this report. Images of each physical element identified in this report were captured in HD digital photos, while manual measurements were taken to establish as-built conditions to facilitate the process of cost estimating. Digital photographs are provided within the report for each barrier to access, to facilitate the review of the data collected. We have found that technical data can be difficult to interpret without a visual component; the photos provide a clear connection between the technical data and each barrier to access.

The Pharmacy building is a historic structure and many barriers to access were identified in the building. That is quite typical, as barriers to access exist in virtually every building, whether new or existing.

No “perfect” building exists in the real world.

This ADA Assessment and Survey report is intended to not only identify barriers to access, but to provide solutions. The basis for this ADA Assessment and Survey process is the underlying desire, on the part of OSU, to improve access by relying on higher standards than the minimum requirements in state and federal building codes. SZS intends to provide the information in this report in a clear and easy to understand format. The information in this report is compiled for use by designated OSU staff and other interested persons, so the content is designed to be understood by professionals and laymen alike.

The findings presented are both narrative and technical in nature; barriers to access identified during the field investigation process are documented in two ways;

1. Narrative Analysis: The analysis of findings is contained in an executive summary in a narrative form that not only describes each type of barrier identified, but also provides a discussion that analyzes the functionality of physical elements. We also provide the reasoning and research behind the identification of barriers that conflict with universal design principles. This analysis may be accompanied by digital photographs or diagrams, where applicable.

NOTE: Understanding building function and usage is essential when interpreting the findings held in this report. The narrative is intended to facilitate this process.

2. Barrier Data Records: Individual barriers to access are entered into the SZS database so that technical information on the barriers can be provided as barrier data records. These barrier data records include digital photographs of each barrier identified, code references that determine the barrier to access, as-built measurements, barrier severity ratings, budgetary cost estimates, recommended solutions for barrier removal and a priority for barrier removal. The information is formatted with two barriers on each report page.

In order to consolidate the report data, some of the more typical barriers found in multiple locations have been grouped within the barrier data records with a description of the locations in which they were found.

Page 5: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

2

A. Pedestrian Facilities and Exterior Spaces Analyzed

This report provides information on campus pedestrian facilities that serve the Pharmacy building. Many physical elements are part of the comprehensive whole that creates a pedestrian facility. The fundamental elements evaluated as to whether they provide accessible pedestrian facilities include the following:

Sidewalks

Walkways

Ramps

Curb Ramps

Blended Transitions

Signalized Intersections

Stairways (94% of people with disabilities are not mobility impaired)

Benches and other Seating Elements

Picnic Facilities

The descriptions provided for physical elements in this report are intended to clearly describe the differences between each physical element, such as when a pedestrian route is a sidewalk, rather than a walkway. The descriptions are intended to explain how the elements interact to form a cohesive pedestrian facility. Other more specific information described within this section intends to provide guidance on determinations made in this report. The key to providing accessible pedestrian facilities is in recognizing that different people with disabilities have different needs. Setting policies that speak to the entire group is essential, rather than focusing one particular subset of the overall group. Universal design principles govern here – physical elements should be usable to everyone that visits campus without having to resort to any adaptation or specialized design. In summary, an accessible route exists within a building, property boundary or interior space and is separate from the PROW. Pedestrian walkways are similar to sidewalks, as paved surfaces are improved for use by pedestrians, but walkways are not located along or adjacent to the curb line, gutter or roadway. Also, walkways are generally not considered part of the PROW. The pedestrian facility is the combination of the PROW and the accessible route, which functions as a whole to provide pedestrian access to facility entrances. As a public building that was constructed prior to the passage of the ADA, the Pharmacy building should have at least one accessible entrance, which was identified at the west entrance. This entrance is provided with an accessible ramp that leads to the first floor where a freight elevator is used to carry passengers to reach all floors.

Page 6: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

3

The Pharmacy building has an accessible route provided within the site from accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible building or facility entrance they serve1 as compared to the 2010 ADA Standard for Accessible Design. Details on barriers identified in that route are provided within the ADA Assessment and Survey of the pedestrian facilities (as a separate report), as well as in the following records. Please see the barrier data records for details.

B. Building Entrances

The building is located near the corner of SW Jefferson Way and SW 15th Street within campus. The building is not connected to the existing sidewalk by an accessible route and accessible parking is not provided on-site. The accessible entrance to the building is located on the back side of the building and is not connected to an accessible route throughout campus. The accessible entrance can be reached by traveling 180 feet along a vehicular traffic lane, which is not provided with a detectable warning for the visually impaired. The pedestrian route to the accessible entry door is sloped and the door to the building is equipped with an automatic door opening device, but the device actuator is not identified with an ISA symbol that has a 70% contrast with the background of the wall on which it is mounted and the actuator is not located on a level landing. It is recommended to move the actuator for the automatic door to a level location along the route to the door. As a performance standard, it is recommended that where a powered door is provided in a building or facility, a sign displaying the International Symbol of Accessibility (ISA) measuring at least 4” x 4” should accompany the automatic door actuating mechanism and that signage needs to provide a 70% contrast against the background wall surface (dark-on-light or light-on-dark).

1 2010 ADA Standards for Accessible Design, Section 206.2.1 Site Arrival Points

Page 7: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

4

INTERIOR SPACES

BASEMENT

The Pharmacy building is a six-story building with a full basement. The Pharmacy building is accessed on the basement level through a corridor which leads to the public spaces and a freight elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is not to be used as a passenger elevator. The elevator was identified with significant over/under-travel of more than 3". Controls and a sign inside the elevator indicate that a "jig button" should be used to correct the travel and bring the car level with floor landings but that control is located at 56" high and is not usable for the visually impaired. The elevator has car call buttons that are outside of accessible reach ranges and travel in the elevator is highly inconsistent, with a step at the threshold of several inches, in some locations. A leveling device is provided within the elevator to allow some self-leveling which is not considered accessible. The control button for self-leveling is not within accessible reach range and the mechanism is not simple to operate and causes the elevator car to move abruptly, which may cause people using mobility assist devices or others with balance challenges to fall. Additional functional issues identified at the elevator included a lack of a door delay when the doors meet an obstruction, no audible controls or lanterns, the call and car buttons were not within reach range and did not illuminate and no functional emergency call system was provided.

One men’s restroom is provided on this floor. The door is not identified with tactile signage and a separate toilet room for wheelchair access is provided. The accessible toilet room also lacked identification signage on the wall or door. A coat rack was provided opposite from the accessible toilet room and no coat hooks were provided within accessible reach ranges. The accessible toilet room was identified with no door closer, which is a functional issue for people with disabilities. People using wheelchairs have an especially difficult challenge to open and close doors, which is why standard toilet stall compartment doors need have self-closing doors. An entry door to a single accommodation toilet room is no different. Other barriers to access include a lavatory that lacks accessible knee clearance, insulation and the distance between the wall and lavatory which is used for maneuvering clearance is not at least 60” wide. The rear grab bar is not centered and the side grab bar is installed so close to the toilet paper dispenser that the bar cannot be used. Access to the seat cover dispenser is blocked by the toilet and the toilet room is not provided with a visual signal appliance (strobe) device to warn the visually impaired. The larger toilet room was identified with a narrow entry door that could prevent access for people using wheelchairs, but it is the only location in this toilet facility that provides urinals, but those fixtures are not installed at an accessible height.

No low fountain was provided in the basement. The existing high fountain may not be usable for short people or for those who use mobility assist devices. Also, lobby informational signage is not provided, even though gender specific restrooms are provided on every other floor, and accessible drinking fountains are not provided on every floor. A ramp provides access from one level of the corridor to the upper level. The ramp was identified with an excessive slope, no wheel guides at the bottom of the handrails and the surface of the ramp did not appear to be slip-resistant. Exit stairways located on the east and west sides of each floor were identified with heavy double doors at the stairway entries and no accessible handrails or guardrails, handrail extensions and grip height, as is common in historic structures with original handrails and guardrails. The ramp also caused a severe cross slope at the entrance door for one of the classrooms on the basement level. A sink where deionized water is available was also

Page 8: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

5

located within the ramp and lacks a level landing, knee clearance and controls. The supply store is located on the basement level and neither of the two service counters were identified with accessible surface height. Visual signage was provided at each door on this level but tactile signage was lacking at each location, including exits and within stairways. The stairways lacked level identification signage for the visually impaired, although visual signage for emergency personnel was provided where the exit stairways were enclosed. No contrasting color was identified at the stairway treads, which can be important to those with low vision and the stairway riser height was not consistent from step to step. This can cause difficulty for pedestrians with disabilities. As a performance standard, it is highly recommended to provide contrasting color at stairway treads to improve visibility for all users.

FIRST FLOOR

The main offices for academic departments are located on the first floor within the central corridor. The women’s restroom on this floor is similar to the men’s restroom on the basement floor. Laboratories and student PC laboratories on this floor lacked accessible entry door hardware, operating force where closers were installed, accessible signage, view panels usable by short people and the spaces lacked maneuvering clearance within the space to allow wheelchair users to participate in meetings. The clear floor space needed to enable use of whiteboards and chalkboards were blocked by furniture or stored items in some locations and the spaces generally lacked accessible light switches and outlets, accessible desks, computer workstations, coat racks and strobe devices. Where sinks were provided, access for wheelchair users and short people was not available. Light switches, and fire pulls throughout the building are located above accessible reach ranges and electrical panels or other elements protruded into the circulation path in corridors throughout the building. Common use areas, hallways and corridors lacked visual signal appliances (strobes), although horns connected to the fire alarm system were installed in corridors. Fire pulls used to actuate the fire alarm system were located above accessible reach ranges and the control mechanisms on the devices were also not usable for people with hand impairments. Many staff use only areas were identified in the building. These spaces include IT rooms, janitorial rooms, private faculty offices and associated spaces. Signage at the door/doorway to these spaces were included in this report as it is located along the public circulation route of travel, but these interior spaces were not investigated as part of this assessment process. In general, institutions and organizations make staff-use-only areas accessible as needed through the reasonable accommodation iterative process between the employer and employee.

SECOND – SIXTH FLOORS

Floor 2 was identified with a laboratory with mock exam rooms. There were two rooms but neither room was designed with accessible counters, sinks, exam tables or maneuvering clearance. The upper floors were found to have the same barriers in the exit stairways and elevator as identified on other floors described above. A hi-low drinking fountain unit was identified on the third floor corridor, but the fixture was not located in an alcove and the fixture was not installed with accessible knee clearance. Classrooms on the upper floors were identified with barriers similar to those described on the first floor. Restrooms on the upper floors were single gender restrooms with the same or similar barriers as described above on the basement or first floors. Exit stairways at the north side of corridors, or within classrooms located on the north side of the building, were identified with narrow doors, a 4” step in two locations and a fire hose bib that protrudes into the exit route with no detectable warning. Exit stairways in corridors are designated

Page 9: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

ADA Assessment & Survey Pharmacy Building

6

as rescue areas, but the door thresholds at the stairway doors are ½” high with no bevel. No communication devices are provided within the rescue areas for people with disabilities to use to call for help or alert emergency personnel of their location. Door knobs were identified on the stairway side of the doors to the rescue areas.

The wheelchair lift on the third floor was labeled by the manufacturer as a porch lift. The lift was not initially identified with an operation key. After the inspection, one key was found in one of three control boxes. The lift needs a key to be inserted in each control at each location (north entry, lift, south entry) in order to operate. Students registered with Student Disability Services may be given a key to use, that they can carry with them, for each of the 3 control boxes, but visitors cannot use the lift at present. An incline platform lift may be a solution for this location that could both increase the stairway egress width to provide emergency egress for all people using the building while also providing vertical access at the stairway in the middle of the central corridor. Areas assessed on floors 4 – 6 did not include restrooms or classrooms. Corridors and exit stairways on these levels were identified with barriers similar to those described above. The following barrier data records provide more detailed information on the barriers described above.

Page 10: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

EXTERIOR AREA BARRIERS

Page 11: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Walkway

Barrier #: 447

X Coordinate: 7478930.789

Barrier Area: Walkways

Barrier Type: Running Slope ‐ Existing (8.3% or more)

Barrier  Description:

Walkway running slope exceeds 5.0% (8.3% or more)

Rec. Solution: Demolish and reconstruct walkway with accessible slope

              Findings:

9.7% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340018.879

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southwest Walkway

Barrier #: 448

X Coordinate: 7479015.771

Barrier Area: Walkways

Barrier Type: Running Slope ‐ Existing (8.3% or more)

Barrier  Description:

Walkway running slope exceeds 5.0% (8.3% or more)

Rec. Solution: Demolish and reconstruct walkway with accessible slope

              Findings:

10.7% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339929.322

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 7

Page 12: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southwest Walkway

Barrier #: 449

X Coordinate: 7479002.863

Barrier Area: Walkways

Barrier Type: Running Slope ‐ Existing (8.3% or more)

Barrier  Description:

Walkway running slope exceeds 5.0% (8.3% or more)

Rec. Solution: Demolish and reconstruct walkway with accessible slope

              Findings:

8.6% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339947.459

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 450A

X Coordinate: 7479025.425

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Bottom

Barrier  Description:

Bottom handrail extension not level for min. 12"

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

No level bottom handrail extension provided

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6.(2)

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.699

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 8

Page 13: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 450B

X Coordinate: 7479025.425

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

44" top handrail extension height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6.(5) and 2010 ADAS 505.10.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.699

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 450C

X Coordinate: 7479025.425

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

30" bottom handrail extension height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6.(5) and 2010 ADAS 505.10.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.699

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 9

Page 14: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 450D

X Coordinate: 7479025.425

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of exterior stairway

Rec. Solution: Consider providing contrasting color on each tread

              Findings:

No contrasting color provided

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 35

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.699

Performance Standard: Yes

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 450E

X Coordinate: 7479025.425

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Directional Sign

Barrier  Description:

No form of vertical access provided at stairway to reach entry door or upper floors

Rec. Solution: Provide directional sign leading to accessible entry

              Findings:

No information on alternate accessible entrance to building

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.699

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 10

Page 15: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ West Entrance

Barrier #: 451

X Coordinate: 7479039.303

Barrier Area: Doors or Gates

Barrier Type: Abrupt Change in Level

Barrier  Description:

Change in level greater than 1/2" leading to door

Rec. Solution: Construct ramp to provide access to door landing

              Findings:

3" step at door landing

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.9.3 and 2010 ADAS 303.3

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340002.19

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southwest Walkway

Barrier #: 452

X Coordinate: 7479036.555

Barrier Area: Walkways

Barrier Type: Abrupt End

Barrier  Description:

Walkway ends abruptly forcing pedestrians to retrace their steps

Rec. Solution: Provide directional sign at junction to identify accessible route

              Findings:

Provide ISA directional sign at junction in route before end

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.1 and 2010 ADAS 206.2.1

As‐built : 250

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339920.089

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 11

Page 16: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southeast Pharmacy Building ‐ Corner A

Barrier #: 454

X Coordinate: 7479128.521

Barrier Area: Blended Transitions

Barrier Type: Truncated Domes

Barrier  Description:

No truncated domes provided at transition into roadway

Rec. Solution: Provide accessible truncated domes as detectable warnings

              Findings:

No detectable warning provided

Quantity: EACH

Notes: Two ‐ way intersection corners  A,D

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.3.1 and 2010 ADAS 705.1.3

As‐built : 1000

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339959.966

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southeast Pharmacy Building ‐ Splitter Island A

Barrier #: 455

X Coordinate: 7479112.066

Barrier Area: Blended Transitions

Barrier Type: Truncated Domes

Barrier  Description:

No truncated domes provided at transition into roadway

Rec. Solution: Provide accessible truncated domes as detectable warnings

              Findings:

No detectable warning provided

Quantity: EACH

Notes: Two ‐ way intersection corners  A,D

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.3.1 and 2010 ADAS 705.1.3

As‐built : 1000

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339942.928

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 12

Page 17: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southeast Pharmacy Building ‐ Splitter Island D

Barrier #: 456

X Coordinate: 7479099.106

Barrier Area: Curb Ramps

Barrier Type: No Curb Ramp

Barrier  Description:

No curb cut at corner (intersection)

Rec. Solution: Demolish existing and construct curb cut

              Findings:

No curb ramp at corner

Quantity: EACH

Notes: Two ‐ way intersection corners  A,D

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

25 CFR 35.131(i)(2) and 2010 ADAS 402.2

As‐built : 3000

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339928.567

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Southeast Pharmacy Building ‐ Corner D

Barrier #: 457

X Coordinate: 7479084.706

Barrier Area: Curb Ramps

Barrier Type: No Curb Ramp

Barrier  Description:

No curb cut at corner (intersection)

Rec. Solution: Demolish existing and construct curb cut

              Findings:

No curb ramp at corner

Quantity: EACH

Notes: Two ‐ way intersection corners  A,D

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

25 CFR 35.131(i)(2) and 2010 ADAS 402.2

As‐built : 3000

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339912.651

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 13

Page 18: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 464

X Coordinate: 7479115.474

Barrier Area: Walkways

Barrier Type: Connecting Acc Route

Barrier  Description:

No connecting accessible route provided

Rec. Solution: Provide additional walkway to connect to existing paths

              Findings:

No accessible route is connected to walkway. Walkway through vehicular traffic lane CS 3.8%

Quantity: LF

Notes: Accessible route to entry thru vehicular traffic lane 180 LF with no detectable warning.  CS 3.8 % in some locations.

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

25 CFR 35.131(i)(2) and 2010 ADAS 206.2.2

As‐built : 0

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340013.392

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 465A

X Coordinate: 7479099.976

Barrier Area: Doors or Gates

Barrier Type: Automatic Doors ‐ Actuation location

Barrier  Description:

Actuation location not at least 36" from nearest point of moving door

Rec. Solution: Relocate actuation device

              Findings:

Automatic door actuator too close to door and is not centered on 30" x 48" wheelchair landing

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.9.6

As‐built : 1250

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340009.063

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 14

Page 19: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 465B

X Coordinate: 7479099.976

Barrier Area: Doors or Gates

Barrier Type: Door/Gate Landing ‐ Existing (4.1% to 4.9%)

Barrier  Description:

Door or gate lacks landing on both sides of door

Rec. Solution: Demolish and reconstruct level landing

              Findings:

4.2% slope at automatic door actuator

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340009.063

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 466

X Coordinate: 7479108.047

Barrier Area: Street Furniture

Barrier Type: Bench ‐ Multiple Barriers

Barrier  Description:

Seat not 20" to 24" deep, 17" to 19" high, min. 42" long or backrest not accessible

Rec. Solution: Recommended: Provide min. 1 accessible seating element or 5% of total

              Findings:

13" bench seat height and no backrest provided

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 903.3

As‐built : 1100

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339969.507

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 15

Page 20: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 467A

X Coordinate: 7479108.099

Barrier Area: Stairways

Barrier Type: Handrail ‐ Both Sides

Barrier  Description:

No handrail provided at both sides of stairway

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

No handrail provided at both sides

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6 and 2010 ADAS 505.10.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339976.631

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 467B

X Coordinate: 7479108.099

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of exterior stairway

Rec. Solution: Consider providing contrasting color on each tread

              Findings:

No contrasting color provided

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 35

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339976.631

Performance Standard: Yes

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 16

Page 21: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ East Entrance

Barrier #: 467D

X Coordinate: 7479108.099

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Lift

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Provide a wheelchair lift to reach upper floors

              Findings:

Stairway is the only pedestrian route into building

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 339976.631

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 468A

X Coordinate: 7479088.184

Barrier Area: Ramps

Barrier Type: Handrail

Barrier  Description:

No handrail provided at both sides

Rec. Solution: Determine if this element is part of accessible route. If so, provide accessible handrails at both s

              Findings:

No handrail provided at both sides

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.7.6 and 2010 ADAS 505.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340081.089

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 17

Page 22: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 468B

X Coordinate: 7479088.184

Barrier Area: Ramps

Barrier Type: Running Slope ‐ Existing (>9.5% or more)

Barrier  Description:

Running slope exceeds 8.33% (>9.5% or more)

Rec. Solution: Determine if this element is part of accessible route. If so, demolish existing and construct new 

              Findings:

19.5% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.7.2 and 2010 ADAS 405.3

As‐built : 200

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340081.089

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 469A

X Coordinate: 7479120.458

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of exterior stairway

Rec. Solution: Consider providing contrasting color on each tread

              Findings:

No contrasting color provided

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 35

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340116.744

Performance Standard: Yes

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 18

Page 23: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 469B

X Coordinate: 7479120.458

Barrier Area: Stairways

Barrier Type: Handrail ‐ Both Sides

Barrier  Description:

No handrail provided at both sides of stairway

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

No handrail provided at both sides

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6 and 2010 ADAS 505.10.2

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340116.744

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 469C

X Coordinate: 7479120.458

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Bottom

Barrier  Description:

Bottom handrail extension not level for min. 12"

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

Bottom handrail extension not level for min. 12"

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6.(2)

As‐built : 225

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340116.744

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 19

Page 24: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 469D

X Coordinate: 7479120.458

Barrier Area: Stairways

Barrier Type: Handrail Extension

Barrier  Description:

Handrail extension does not return to wall, guard or landing surface

Rec. Solution: Provide accessible handrails at both sides of stairway

              Findings:

Top handrail extension does not return to wall, guard or landing surface

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1109.8.6.(2) and 2010 ADAS 505.10.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340116.744

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ Northeast Entrance

Barrier #: 469E

X Coordinate: 7479120.458

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Directional Sign

Barrier  Description:

No form of vertical access provided at stairway to reach entry door or upper floors

Rec. Solution: Provide directional sign leading to accessible entry

              Findings:

No information on alternate accessible entrance to building

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340116.744

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 20

Page 25: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Walkway

Barrier #: 477A

X Coordinate: 7479121.853

Barrier Area: Walkways

Barrier Type: Cross Slope ‐ Existing (5.0% or more)

Barrier  Description:

Cross slope exceeds 2.0%  (5.0% or more)

Rec. Solution: Demolish existing and construct new route

              Findings:

5.3% cross slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340137.049

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Walkway

Barrier #: 477B

X Coordinate: 7479122.161

Barrier Area: Walkways

Barrier Type: Running Slope ‐ Existing (8.3% or more)

Barrier  Description:

Walkway running slope exceeds 5.0% (8.3% or more)

Rec. Solution: Demolish and reconstruct walkway with accessible slope

              Findings:

13.4% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340137.771

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 21

Page 26: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Walkway

Barrier #: 478A

X Coordinate: 7479002.353

Barrier Area: Walkways

Barrier Type: Running Slope ‐ Existing (5.0% ‐ 8.2%)

Barrier  Description:

Walkway running slope exceeds 5.0% (5.0% ‐ 5.5%)

Rec. Solution: Provide accessible handrails at both sides with landings where needed

              Findings:

8.2% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340198.354

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Walkway

Barrier #: 478B

X Coordinate: 7479008.513

Barrier Area: Walkways

Barrier Type: Surface Condition ‐ Damaged

Barrier  Description:

Walkway surface is not firm and stable (cracked, broken or loose soil, etc.)

Rec. Solution: Repair surface to make firm and stable

              Findings:

Broken bricks

Quantity: LF

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.5 and 2010 ADAS 302.1

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340124.221

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 22

Page 27: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Walkway

Barrier #: 479

X Coordinate: 7479017.332

Barrier Area: Walkways

Barrier Type: Cross Slope ‐ Existing (5.0% or more)

Barrier  Description:

Cross slope exceeds 2.0%  (5.0% or more)

Rec. Solution: Demolish existing and construct new route

              Findings:

12.7% cross slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1103.2.4.3 and 2010 ADAS 403.3

As‐built : 45

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340119.773

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Entrance

Barrier #: 480A

X Coordinate: 7479077.185

Barrier Area: Doors or Gates

Barrier Type: Door/Gate Landing ‐ Existing (3.1% to 4.0%)

Barrier  Description:

Door or gate lacks landing on both sides of door

Rec. Solution: Demolish and reconstruct level landing

              Findings:

4.3% slope

Quantity: SF

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 125

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340143.704

Performance Standard: No

Reference Dwg: 1 of 6

ADA Assessment and Survey 2015 23

Page 28: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  7/1/2011 Report Date 7/1/2011

Location: Exterior ‐ North Entrance

Barrier #: 480B

X Coordinate: 7479077.185

Barrier Area: Doors or Gates

Barrier Type: Threshold (ramp req'd.)

Barrier  Description:

Door/Gate threshold height exceeds 1/2" with a bevel

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

OSSC 1008.1.7 and 2010 ADAS 404.2.5

As‐built : 750

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: 340143.704

Performance Standard: No

Reference Dwg: 1 of 6

Field Date:  Report Date

Location:

Barrier #:

X Coordinate:

Barrier Area:

Barrier Type:

Barrier  Description:

Rec. Solution:

              Findings:

Quantity:

Notes: Barrier record intentionally left blank to facilitate printing

Barrier Severity: Cost Est

Implementation Date:

Status: Open

Implementation Phase:

Code References:

As‐built :

Facility Function: Public

Implementation Priority:

Bldg Name: Pharmacy Building

Y Coordinate:

Performance Standard:

Reference Dwg:

ADA Assessment and Survey 2015 24

Page 29: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

INTERIOR AREA BARRIERS

Page 30: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1A

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Accessible Route

Barrier  Description:

Clear floor space does not adjoin an accessible route or another space

Rec. Solution: Remodel area to provide connection to accessible route

              Findings:

Clear floor space not accessible

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $175.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1B

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Floor Surface ‐ Slope

Barrier  Description:

Floor surface slope exceeds 2.0%

Rec. Solution: Remodel to provide level clear floor space at controls/mechanisms

              Findings:

5.6% running slope

Quantity: SF

Notes:

Barrier Severity: 2 Necessary Cost Est $2,300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302 & 303

As‐built : 4

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 25

Page 31: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Automatic Doors ‐ Actuation Clear Floor Space

Barrier  Description:

Actuation control lacks clear floor space min. 30" x 48" at device beyond the arc of the door swing

Rec. Solution: Relocate actuation device

              Findings:

3.6% slope

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $400.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.3.5 & 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height 1/2" with Ramp

Barrier  Description:

Door/Gate threshold bevel at max 1/2" lip exceeds 1:2 or 50% slope

Rec. Solution: Provide ramp leading to new level landing at door

              Findings:

Metal door threshold 1/2" without a bevel at exit side of door

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 26

Page 32: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Automatic Doors ‐ Reopening

Barrier  Description:

Automatic doors do not remain open for at least 6 seconds

Rec. Solution: Adjust door mechanism

              Findings:

Doors do not remain open for at least 6 seconds

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADA 404.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Automatic Doors ‐ Reopening

Barrier  Description:

Automatic doors do not reopen after encountering an obstruction

Rec. Solution: Adjust door mechanism

              Findings:

Door does not re‐open after encountering an obstacle

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADA 404.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 27

Page 33: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1G

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Provide detectable warning (wing walls)

              Findings:

Electrical panels protrude  4‐1/2" ‐ 6" at 44" ‐ 67" high at latch side of accessible entry door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1H

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 28

Page 34: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Accessible Entrance

Barrier #: 1I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Automatic Doors ‐ Sign

Barrier  Description:

ISA symbol at automatic door opening device not min. 4" x 4" in size

Rec. Solution: Recommended: Provide ISA symbol min. 4" x 4" in size

              Findings:

Existing symbol 1‐3/4" high. Not visible from a distance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: ISA ‐ Non‐Accessible Entry

Barrier  Description:

Sign directing people to accessible entrance needed where all doors are not accessible

Rec. Solution: Provide ISA directional sign with arrow directing people to accessible entrance

              Findings:

ISA directional sign not provided where door is not on an accessible route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 29

Page 35: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 30

Page 36: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Exterior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period

Rec. Solution: Replace or adjust existing  closer

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 31

Page 37: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Northeast Entrance

Barrier #: 2F

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Door

Barrier  Description:

Ground floor doors that exit to exterior lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT” at exit side of door

              Findings:

Exit door with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Corridor

Barrier #: 3

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 32

Page 38: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 15

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Door

Barrier  Description:

Ground floor doors that exit to exterior lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT” at exit side of door

              Findings:

Exit door with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 33

Page 39: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

13 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 34

Page 40: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4F

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Lobby Info Sign

Barrier  Description:

No lobby informational sign with location of accessible elements

Rec. Solution: Provide lobby informational sign

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 35

Page 41: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Side Reach

Barrier  Description:

Fire extinguisher forward or side reach exceeds 48"

Rec. Solution: Relocate fire extinguisher

              Findings:

52" high

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4H

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Flyer holders 63" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 36

Page 42: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4I

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4J

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Display protrudes 7‐1/2" at 48" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 37

Page 43: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4K

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Knee Clearance

Barrier  Description:

Knee clearance under fountain not min. 27" high

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4L

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Bubbler height

Barrier  Description:

Bubbler height exceeds 36"

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

42" bubbler height

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 38

Page 44: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4M

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Operation ‐ Replacement

Barrier  Description:

Operating mechanism involves more than 5 lbf to operate

Rec. Solution: Replace drinking fountain with accessible hi‐low unit

              Findings:

Needed more than 5 lbf where fountain is not adjustable

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4N

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Hi‐Low Unit

Barrier  Description:

No hi‐low drinking fountain provided in facility

Rec. Solution: Provide min. one hi‐low fountain within facility

              Findings:

No low fountain provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 211.2 & 602.7

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 39

Page 45: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4O

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Running Slope ‐ Existing (>9.5% or more)

Barrier  Description:

Running slope exceeds 8.33% (>9.5% or more)

Rec. Solution: Demolish existing and construct new ramp

              Findings:

7.7% ‐ 10.5% running slope

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $7,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 405.3

As‐built : 35

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4P

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Edge Protection ‐ Wheel Guides

Barrier  Description:

No wheel guides where the ramp surface is not bounded by a wall

Rec. Solution: Provide min. 2" curb or wheel guide centered at 3" above ground at both sides of ramp 

              Findings:

No wheel guides provided

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $7,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 405.9

As‐built : 35

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 40

Page 46: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4Q

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Handrail Grip

Barrier  Description:

Handrail grip is not continuous

Rec. Solution: Replace handrails at both sides of ramp

              Findings:

Handrail grip is not continuous at supports

Quantity: LF

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4R

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Floor Surface ‐ Slip resistance

Barrier  Description:

Floor surface not slip‐resistant

Rec. Solution: Remodel facility to provide slip resistant floor surface

              Findings:

Floor surface not slip‐resistant

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $27,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302 & 303

As‐built : 110

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 41

Page 47: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4S

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Landing ‐ Existing (≥ 5.0%)

Barrier  Description:

Door or gate lacks landing on both sides of door

Rec. Solution: Demolish and reconstruct level landing

              Findings:

Door landing to room 131 within running slope CS 5.3% and RS 4.1%

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.4.4

As‐built : 40

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4T

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Provide detectable warning (wing walls)

              Findings:

Sink located at top of ramp protrudes 10‐1/4" at 32" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 42

Page 48: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Central Corridor

Barrier #: 4U

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink Faucet ‐ Operation

Barrier  Description:

Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist

Rec. Solution: Replace faucet

              Findings:

Faucet not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.4 & 309

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5A

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 43

Page 49: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

1 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 44

Page 50: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5E

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 45

Page 51: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Discharge

Barrier  Description:

Tactile stairway signage not provided to indicate stair level or discharge level

Rec. Solution: Provide sign indicating stair level and discharge level (raised star) where applicable

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Opening Limitations

Barrier  Description:

Guard or handrail have openings that allow passage of a 4" sphere

Rec. Solution: Replace guardrail

              Findings:

Guardrail 35" high with 13" openings

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $3,150.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 14

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 46

Page 52: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Top

Barrier  Description:

Extension does not extend horizontally above landing for min. 12" from first riser nosing

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

4" ‐ 11" long

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5I

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension ‐ Top

Barrier  Description:

Extension does not extend horizontally above landing for min. 12" from first riser nosing

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

4" ‐ 11" long

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 47

Page 53: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5J

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

32" handrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $37,800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 168

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5K

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $4,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 120

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 48

Page 54: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5L

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Opening Limitations

Barrier  Description:

Guard or handrail have openings that allow passage of a 4" sphere

Rec. Solution: Replace guardrail

              Findings:

Guard 35" high with 14" openings

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Exit Stairway

Barrier #: 5M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $27,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 5

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 49

Page 55: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6A

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Car Control Buttons ‐ Location

Barrier  Description:

Car control buttons located above 48" from finish floor measured at the centerline

Rec. Solution: Replace control panel

              Findings:

52" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.6.1 & 409.4.6

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Evacuation Plan

Barrier  Description:

No evacuation plan provided

Rec. Solution: Provide evacuation sign usable by the visually impaired

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 50

Page 56: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6C

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall lanterns ‐ Audible Direction

Barrier  Description:

Audible signal does not sound once for the up direction and twice for the down direction 

Rec. Solution: Replace hall lanterns

              Findings:

No audible controls provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,675.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6D

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ Registration

Barrier  Description:

Visual indication not provided to show each call registered and extinguished when answered

Rec. Solution: Replace hall call buttons

              Findings:

No indication of travel within lobby

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 51

Page 57: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6E

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Threshold

Barrier  Description:

Elevator car landing is not level with entry. (Overtravel or undertravel identified)

Rec. Solution: Adjust to maintain car in level condition within 1/2" of the landing, irrespective of load.

              Findings:

1‐1/2" high

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.4

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6F

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Door Delay Duration

Barrier  Description:

Door reopening devices does not remain effective for 20 seconds minimum

Rec. Solution: Adjust door delay

              Findings:

3 second delay

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.3.3.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 52

Page 58: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6G

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Handrails ‐ None Provided

Barrier  Description:

No handrail provided within elevator car

Rec. Solution: Provide handrail on at least one wall of car

              Findings:

No handrail provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6H

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Car Control Buttons ‐ Location

Barrier  Description:

Car control buttons located above 48" from finish floor measured at the centerline

Rec. Solution: Replace control panel

              Findings:

49" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.6.1 & 409.4.6

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 53

Page 59: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6I

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Car Control Buttons ‐ Illumination

Barrier  Description:

Visual floor buttons do not illuminate as the car passes floors or stops

Rec. Solution: Replace car controls

              Findings:

Buttons do not illuminate

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.8

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6J

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Controls

Barrier  Description:

Emergency controls (incl. emergency stop and alarm) are located below 35"

Rec. Solution: Replace emergency controls

              Findings:

31" high

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.6.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 54

Page 60: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Elevator

Barrier #: 6K

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Controls ‐ 2‐way

Barrier  Description:

Emergency two‐way communication system not provided

Rec. Solution: Replace emergency system

              Findings:

Uses voice communication

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.9 & ASME A17.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Pharmacy Storeroom 115

Barrier #: 7A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 55

Page 61: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/29/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Pharmacy Storeroom 115

Barrier #: 7B

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max.  34" high

              Findings:

36‐1/4" ‐ 39‐1/2"  high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 56

Page 62: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8B

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Discharge

Barrier  Description:

Tactile stairway signage not provided to indicate stair level or discharge level

Rec. Solution: Provide sign indicating stair level and discharge level (raised star) where applicable

              Findings:

No tactile sign provided with a raised star provided at discharge level on the intermediate landing

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $3,360.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 96

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 57

Page 63: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull ‐ Height

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

63" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 58

Page 64: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

29" handrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $32,400.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 144

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Grip

Barrier  Description:

Handrail grip is not continuous

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

Handrail grip is not continuous at supports

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 59

Page 65: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Both Sides

Barrier  Description:

No handrail provided at both sides of stairway

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No handrail provided at both sides at inner guardrail

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ADAAG 4.9.4* & 2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8I

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension

Barrier  Description:

Handrail extension does not return to wall, guard or landing surface

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No extension provided

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 60

Page 66: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8J

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

32‐1/2" guardrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8K

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Riser Height ‐ Existing

Barrier  Description:

Stair riser height or tread width is not consistent

Rec. Solution: No remediation recommended in historic structure

              Findings:

No consistent stair riser height or tread width provided. Riser height varies from 5‐1/2" to 6".

Quantity: SF

Notes:

Barrier Severity: 5 Technically Infea Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 61

Page 67: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8L

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ East Stairway

Barrier #: 8M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 62

Page 68: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9A

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided at basement level

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9B

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Discharge

Barrier  Description:

Tactile stairway signage not provided to indicate stair level or discharge level

Rec. Solution: Provide sign indicating stair level and discharge level (raised star) where applicable

              Findings:

No tactile sign provided at discharge level on intermediate landing

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 63

Page 69: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9C

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $3,360.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 96

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9D

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull ‐ Accessible Route

Barrier  Description:

Fire pull not on accessible route

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not accessible. Fire pull located above stairs on 3 treads from intermediate landing.

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 64

Page 70: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured at lower/intermediate landing and exterior

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

29" handrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $32,400.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 144

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 65

Page 71: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Grip

Barrier  Description:

Handrail grip is not continuous

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

Handrail grip is not continuous at supports

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9H

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Both Sides

Barrier  Description:

No handrail provided at both sides of stairway

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No handrail provided at both sides at inner guardrail

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ADAAG 4.9.4* & 2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 66

Page 72: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9I

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Extension

Barrier  Description:

Handrail extension does not return to wall, guard or landing surface

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

No extension provided at inner guardrail

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9J

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide accessible guardrail at min. 42" high

              Findings:

32‐1/2" guardrail height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 67

Page 73: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9K

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Riser Height ‐ Existing

Barrier  Description:

Stair riser height or tread width is not consistent

Rec. Solution: No remediation recommended in historic structure

              Findings:

No consistent stair riser height or tread width provided. Riser height varies from 5‐1/2" to 6".

Quantity: SF

Notes:

Barrier Severity: 5 Technically Infea Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ West Stairway

Barrier #: 9L

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Door

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 68

Page 74: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs in corridor

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 4

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 69

Page 75: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf at both doors although they were propped open

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

3 second sweep at both doors although they were propped open

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 70

Page 76: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10E

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10F

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

25‐1/2" knee clearance in waiting area

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 71

Page 77: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10G

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Vending Machine ‐ High Reach Range

Barrier  Description:

Vending machine point of control not at max. 48" high for side reach

Rec. Solution: Contact vendor to obtain replacement

              Findings:

52" and 53" high

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Southeast Corridor

Barrier #: 10H

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 72

Page 78: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 73

Page 79: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/push 12" SEC

Barrier  Description:

Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer

Rec. Solution: Move stored item

              Findings:

Strike edge clearance blocked by trash bin at push (exit) side

Quantity: ADMINI

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 74

Page 80: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11E

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Pedestal Base

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Pedestal base blocks knee clearance at 3 tables

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.2.2 & 306.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Clear Floor Space ‐ Stored Elements

Barrier  Description:

Clear floor space for wheelchair not provided at control or mechanism

Rec. Solution: Move stored items

              Findings:

Furniture blocks refrigerator clear floor space

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 75

Page 81: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted between 40" and 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible. Provide assistance

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

51" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 76

Page 82: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Self‐learning Lounge 101

Barrier #: 11I

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12A

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Vision Lights

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 77

Page 83: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12B

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Door Hardware ‐ Privacy Latch

Barrier  Description:

Privacy latch provided involves tight grasping, pinching or twisting

Rec. Solution: Replace door latch

              Findings:

Hardware not operable with a closed fist

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12C

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

Switch 52" and blocked by podium

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 78

Page 84: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Podium  ‐ Surface Height

Barrier  Description:

Surface height exceeds 34" high

Rec. Solution: Provide min. 1 accessible  podium

              Findings:

48" surface height

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12E

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Clear Floor Space ‐ Stored Elements

Barrier  Description:

Clear floor space for wheelchair not provided at control or mechanism

Rec. Solution: Move stored items

              Findings:

Stationary podium blocks emergency phone block clear floor space

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 79

Page 85: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Projector Screen Pull

Barrier  Description:

Screen pull not at max. 48" high for side reach

Rec. Solution: Relocate to max. 48" high or provide extension

              Findings:

Projector screen pull above 48" when retracted

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Podium ‐ Knee Clearance

Barrier  Description:

Podium knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible  podium

              Findings:

Adjustable podium has 14" toe clearance and 9‐1/4" high shelf under work surface

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 80

Page 86: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide min. 2 accessible desks

              Findings:

32 total desks and none are accessible

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $1,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12I

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Table at front of classroom has 22" high and 13" deep knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 81

Page 87: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12J

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Accessible Route ‐ Encroaching Objects

Barrier  Description:

Clear floor space does not adjoin an accessible route or another space

Rec. Solution: Move elements to provide connection to accessible route

              Findings:

No passage through seating to reach pencil sharpener

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Classroom 107

Barrier #: 12K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ No Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 82

Page 88: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Restroom Entry Vestibule 109

Barrier #: 13A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Restroom Entry Vestibule 109

Barrier #: 13B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ ISA at Accessible Restroom

Barrier  Description:

No ISA symbol on wall sign posted at accessible toilet room

Rec. Solution: Provide ISA symbol on restroom wall sign

              Findings:

No ISA sign provided at entry

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.8

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 83

Page 89: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Restroom Entry Vestibule 109

Barrier #: 13C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/push 12" SEC

Barrier  Description:

Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer

Rec. Solution: Remove stored item

              Findings:

Trash bin blocks strike edge clearance at exit side

Quantity: ADMINI

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Restroom Entry Vestibule 109

Barrier #: 13D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

63" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 84

Page 90: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ ISA at Accessible Restroom

Barrier  Description:

No ISA symbol on wall sign posted at accessible toilet room

Rec. Solution: Provide ISA symbol on restroom wall sign

              Findings:

No ISA sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.8

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

No closer provided where door needs to self‐close

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 85

Page 91: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clearance ‐ SEC Blocked

Barrier  Description:

Trash bin or stored items block strike edge clearance at exit side of door

Rec. Solution: Move trash bin

              Findings:

No strike edge clearance

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/2" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 86

Page 92: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Maneuvering Clearance

Barrier  Description:

No 60" turning circle provided in toilet facility (min. 27" high above floor)

Rec. Solution: Remodel toilet room

              Findings:

57" turning circle

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $57,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.2.1

As‐built : 100

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 87

Page 93: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser to wall adjacent to lavatory

              Findings:

Dispenser protrudes 9" into side transfer space

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Rear Grab Bar

Barrier  Description:

Rear grab bar not centered 12" from wall and 24" on the other side of WC

Rec. Solution: Replace grab bars with reinforcement

              Findings:

11" from wall side

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 88

Page 94: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser interferes with use of side grab bar

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

3/4" from side grab bar

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 609.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Centerline

Barrier  Description:

Water closet centerline not between 16" and 18" O. C.

Rec. Solution: Relocate water closet

              Findings:

19‐1/2" on center

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $850.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 89

Page 95: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Men's Accessible Restroom 109B

Barrier #: 14L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 90

Page 96: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ No Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Replace sign

              Findings:

No sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

29‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 91

Page 97: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/2" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 92

Page 98: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

48‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Rim

Barrier  Description:

Min. 1 urinal has no elongated rim projecting  at least 13‐1/2" from wall

Rec. Solution: Replace urinal

              Findings:

12" from rim

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $1,600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 605.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 93

Page 99: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Flush Controls

Barrier  Description:

Urinal flush controls mounted higher than 48" above the floor

Rec. Solution: Replace urinal controls where possible or entire urinal

              Findings:

50" high

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $1,600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser 6‐1/4" deep at 54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 94

Page 100: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Height

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Stall ‐ Unobstructed Access

Barrier  Description:

Stall lacks clear, unobstructed access path of at least min. 36" to door

Rec. Solution: Replace compartment

              Findings:

24‐1/2" to door

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $4,950.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 95

Page 101: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Inside of compartment door lacks a loop or U‐pull below latch

Rec. Solution: Provide hardware

              Findings:

No U‐pull provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Outside of compartment door lacks a loop or U‐pull below latch

Rec. Solution: Provide hardware

              Findings:

No U‐pull provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 96

Page 102: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Compartment door hardware  involves user to grasp or twist to operate

Rec. Solution: Provide hardware

              Findings:

Hardware not operable with a closed fist

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $900.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

68" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 97

Page 103: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser not within 7" to 9" from front edge of toilet

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

24‐1/2" from rim

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Accessible Route

Barrier  Description:

Accessible route not provided to restroom (min. 36" clear width)

Rec. Solution: Relocate restroom or redesign

              Findings:

No min. 36" clear width provided

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 402 & 403

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 98

Page 104: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 1 ‐ Mul ‐accommoda on Toilet Room 109A

Barrier #: 15R

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 2 of 6

ADA Assessment and Survey 2015 99

Page 105: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16A

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Knee Clearance

Barrier  Description:

Knee clearance under fountain not min. 27" high

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/30/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16B

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: High Bubbler

Barrier  Description:

Fountain high bubbler located below 42" above ground or floor

Rec. Solution: Replace fountain with accessible unit

              Findings:

41" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 211.2 & 602.7

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 100

Page 106: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16C

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Bubbler height

Barrier  Description:

Bubbler height exceeds 36"

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

40" water spigot control high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16D

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Hi‐Low Unit

Barrier  Description:

No hi‐low drinking fountain provided on each floor of building

Rec. Solution: Provide min. one hi‐low fountain on each floor

              Findings:

No low fountain provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 211.2 & 602.7

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 101

Page 107: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16E

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

25‐1/2" knee clearance at the only table provided in lobby

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Central Lobby

Barrier #: 16F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No sign provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 102

Page 108: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17A

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Permanent Room/Space

Barrier  Description:

No sign with raised characters and Braille at permanent room or space with visual sign

Rec. Solution: Provide sign at latch side of entry door, where possible

              Findings:

No tactile info on sign with visual information in 10 locations within corridor

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 10

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 103

Page 109: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: No remediation recommended. Fire doors are propped open at all times.

              Findings:

Operating force could not be measured on fire doors

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17D

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Vision Lights in Doors

Barrier  Description:

Doors or gates with view panels or side lights adjacent to doors not max. 43" high

Rec. Solution: Replace door or vision panel in door

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 104

Page 110: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17E

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: No remediation recommended. Fire doors are propped open at all times.

              Findings:

Unable to test door closer

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17F

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Outlets 12" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 105

Page 111: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Side Reach

Barrier  Description:

Fire extinguisher forward or side reach exceeds 48"

Rec. Solution: Relocate fire extinguisher

              Findings:

52" high

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17H

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Visual Sign

Barrier  Description:

No Braille/tactile information on visual sign

Rec. Solution: Provide Braille/tactile sign

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 106

Page 112: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17I

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

First aid kit  protrudes 4‐3/4" at 60" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17J

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high and provide detectable warning

              Findings:

First aid kit  controls 68" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 107

Page 113: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17K

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Sink protrudes 9‐1/4" into path of travel

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17L

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and  8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Replace cabinet and remount sink

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 108

Page 114: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17M

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Exposed Pipes

Barrier  Description:

Exposed hot water/drain pipes not insulated or configured so as to protect against contact

Rec. Solution: Provide insulation at drain pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $120.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink Faucet ‐ Operation

Barrier  Description:

Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist

Rec. Solution: Replace faucet

              Findings:

Faucet not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.4 & 309

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 109

Page 115: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17O

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Door Mat

Barrier  Description:

Recessed doormat not anchored to floor (possible trip hazard)

Rec. Solution: Replace door mat

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17P

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Fire Alarm ‐ Pull Actuator Height

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

63" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 110

Page 116: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17Q

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Hi‐Low Unit

Barrier  Description:

No hi‐low drinking fountain provided on each floor of building

Rec. Solution: Provide min. one hi‐low fountain on each floor

              Findings:

No hi‐low drinking fountain provided on this floor

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 211.2 & 602.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17R

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 111

Page 117: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Central Corridor

Barrier #: 17S

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

Outlet 12" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 112

Page 118: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 113

Page 119: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 114

Page 120: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/2"

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide new door threshold

              Findings:

Metal door threshold 1/2" without a bevel at exit side of door leading to designated rescue area

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide tactile sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 115

Page 121: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Stairway

Barrier #: 18H

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Elevator

Barrier #: 19A

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ 42" High

Barrier  Description:

The centerline of the hall call buttons not max. 42" above the floor

Rec. Solution: Replace hall call buttons

              Findings:

52" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 116

Page 122: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Elevator

Barrier #: 19B

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons

Barrier  Description:

Hall call buttons not internally illuminated with a white light over the entire button surface

Rec. Solution: Replace hall call buttons

              Findings:

Hall call buttons not internally illuminated

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Elevator

Barrier #: 19C

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Sign at Call Station

Barrier  Description:

Sign stating "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS" not provided with tactile information

Rec. Solution: Replace sign

              Findings:

Evacuation sign not tactile

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 117

Page 123: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Elevator

Barrier #: 19D

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall lanterns ‐ Audible Direction

Barrier  Description:

Audible signal does not sound once for the up direction and twice for the down direction 

Rec. Solution: Replace hall lanterns

              Findings:

No audible controls provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,675.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Elevator

Barrier #: 19E

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ Registration

Barrier  Description:

Visual indication not provided to show each call registered and extinguished when answered

Rec. Solution: Replace hall call buttons

              Findings:

No indication of travel within lobby

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 118

Page 124: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign at entry doors and closet within interior space

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: ISA ‐ Directional Sign

Barrier  Description:

No directional signage provided where accessible route diverges from main route

Rec. Solution: Provide ISA directional signage indicating location of accessible entry door

              Findings:

South door has 2" SEC at pull (entry) side

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6 Advisory

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 119

Page 125: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ New Construction

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $4,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device and ISA directional sign at other door

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 120

Page 126: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device and ISA directional sign at other door

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knobs not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 121

Page 127: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Computer table in 3 locations has 25‐1/2" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20H

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

Flyers above 48" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 122

Page 128: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20I

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

Outlets on floor at meeting table

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20J

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")

Barrier  Description:

Outlet located over an 10" to 24" obstruction max. 34" high located above 46"

Rec. Solution: Relocate control or mechanism to max. 46" high

              Findings:

40‐1/2" high and 23" deep behind PC stations

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 123

Page 129: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20K

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

Printer controls 54" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20L

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible. Provide assistance

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 124

Page 130: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Rite Aid Resource Room 235

Barrier #: 20M

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Office Room 235B

Barrier #: 21A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 125

Page 131: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Office Room 235B

Barrier #: 21B

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Pedestal Base

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Pedestal base blocks knee clearance

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.2.2 & 306.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Office Room 235B

Barrier #: 21C

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Clear Floor Space

Barrier  Description:

Clear floor space 30" x 48" not provided at table

Rec. Solution: Rearrange furniture to provide wheelchair access

              Findings:

Clear floor space not accessible

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 126

Page 132: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 127

Page 133: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 128

Page 134: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/push 12" SEC

Barrier  Description:

Door/Gate at push side with min. 48" lacks min. 12" strike edge clearance with latch/closer

Rec. Solution: Provide automatic door opening device

              Findings:

4" strike edge clearance at exit (push) side 4" due to fixed cabinet

Quantity: ADMINI

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted between 40" and 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible. Provide assistance.

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 129

Page 135: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max.  34" high

              Findings:

Work counter 37" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and  8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Replace cabinet and remount sink

              Findings:

Sink 26‐1/2" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 130

Page 136: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22I

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Actuator/Control ‐ Side Reach Obstructed (10"‐24")

Barrier  Description:

Control or mechanism over an 10" to 24" obstruction max. 34" high located above 46"

Rec. Solution: Relocate control or mechanism to max. 46" high

              Findings:

Soap dispenser 25" deep and 45" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22J

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Electrical Outlets ‐ Side Reach Obstructed (10"‐24")

Barrier  Description:

Outlet located over an 10" to 24" obstruction max. 34" high located above 46"

Rec. Solution: Relocate control or mechanism to max. 46" high

              Findings:

48" high and 25" deep over an obstruction 36" high

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $175.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 131

Page 137: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22K

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Shelves or Cabinet

Barrier  Description:

Shelf or cabinet not mounted between 40" and 48" above floor or ground

Rec. Solution: Provide additional shelf/cabinet at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible. Provide assistance

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22L

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Fume Hood ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible biosafety cabinet in lab

              Findings:

15: deep knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $12,450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 132

Page 138: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22M

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Biosafety Cabinet ‐ Work Surface Rim

Barrier  Description:

Work surface height exceeds 34" high

Rec. Solution: Reposition cabinet to provide rim height

              Findings:

Work counter 38‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Flynn Prescrip on Laboratory 237

Barrier #: 22N

X Coordinate: N/A

Barrier Area: Laboratory Facilities

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 133

Page 139: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs at entry doors

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: ISA ‐ Directional Sign

Barrier  Description:

No directional signage provided where accessible route diverges from main route

Rec. Solution: Provide ISA directional signage leading to accessible entrance door

              Findings:

South door has 2" strike edge clearance at pull (entry) side

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.6 Advisory

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 134

Page 140: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other door

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 135

Page 141: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device at one door and ISA directional sign at other door

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knobs not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 136

Page 142: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Workstation ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 27" high, 30" wide and 8" deep not provided

Rec. Solution: Provide min. 1 accessible workstation of each type or overall 5%

              Findings:

Instructors workstation has 28‐1/2" wide knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23H

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Shelves or Cabinets

Barrier  Description:

Shelf or cabinet not mounted max. 48" above floor or ground

Rec. Solution: Provide additional shelf at accessible height or provide assistance

              Findings:

Shelf or cabinet not accessible. Provide assistance

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 137

Page 143: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23I

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table by adjusting it and leaving it in place for use at any time. Avoid p

              Findings:

12 student tables provided with 26‐1/4" knee clearance to supports under work surface, but tables are adjustable

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Weighing Scale ‐ Clear Floor Space

Barrier  Description:

Clear floor space of min. 30" by 48" not provided at public scale

Rec. Solution: Provide min. 1 wheelchair accessible  scale

              Findings:

Scales in two locations not wheelchair accessible

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $675.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 138

Page 144: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23K

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Accessible Route

Barrier  Description:

Clear floor space does not adjoin an accessible route or another space

Rec. Solution: Remodel area to provide connection to accessible route through min. 1 mock exam room

              Findings:

Clear floor space not accessible between exam table and counter

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $7,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305

As‐built : 40

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23L

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Treatment tables have 23‐1/2" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 139

Page 145: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23M

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max.  34" high

              Findings:

Counters 36" high with no accessible section

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and  8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Provide min. 1 accessible wash sink in mock exam room

              Findings:

Sink in mock treatment area has 26" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 140

Page 146: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23O

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max.  34" high

              Findings:

Fixed counters at east wall 36" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23P

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 3 ft segment of accessible counter. Flip‐up counters, adjacent tables and similar de

              Findings:

Fixed counters at east wall have no knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 141

Page 147: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23Q

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

Phone control 62" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Longs Patient Care Center

Barrier #: 23R

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 142

Page 148: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 143

Page 149: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

16 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 144

Page 150: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $3,600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 16

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24F

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Protruding Hazard

Barrier  Description:

Fire extinguisher protrudes into circulation path more than 4" between 27" and 80"

Rec. Solution: Remount extinguisher with leading edge below 27" or provide detectable warning

              Findings:

Fire extinguisher creates a protruding hazard

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 145

Page 151: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24G

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Clear width passage through door, sliding/folding door or gate is not min. 32"

Rec. Solution: Replace door or gate and frame

              Findings:

29‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24H

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 146

Page 152: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  10/31/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace closer or provide automatic door opening device

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24J

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 147

Page 153: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24K

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide tactile stair ID sign inside stairway

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24L

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail Height

Barrier  Description:

Handrail grip measured at center not 34"‐ 38" high

Rec. Solution: Provide handrails at both sides of stairway

              Findings:

31" handrail grip height

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $37,800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.10.2

As‐built : 168

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 148

Page 154: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24M

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $4,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 120

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24N

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Handrail ‐ Opening Limitations

Barrier  Description:

Guard or handrail have openings that allow passage of a 4" sphere

Rec. Solution: Replace handrails

              Findings:

Guardrail 35" high with 14" openings

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $37,800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 168

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 149

Page 155: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ North Exit Stairway

Barrier #: 24O

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

Exit door at ground level has 4" curb at threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $3,600.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 16

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs at 5 doors in corridor

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 5

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 150

Page 156: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: No remediation recommended

              Findings:

Unable to test door closer

Quantity: EACH

Notes:

Barrier Severity: 5 Technically Infea Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 151

Page 157: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25D

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

Mailboxes above 48" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Doormat at classroom 213 not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 152

Page 158: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ South Central Corridor

Barrier #: 25F

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Horn/Strobe Device

Barrier  Description:

No horn or strobe in corridor where fire alarm exists in building

Rec. Solution: Provide horn/strobe in common use area

              Findings:

No horn/strobe provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign at entry and 2 offices within space

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 3

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 153

Page 159: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 154

Page 160: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 155

Page 161: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26G

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Clear Floor Space ‐ Wheelchair Use

Barrier  Description:

Clear floor space of min. 30" by 48" not provided

Rec. Solution: Rearrange furniture to provide wheelchair access

              Findings:

Waiting area lacks clear floor space within existing seating rows

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 156

Page 162: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26H

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Counter ‐ Surface Height

Barrier  Description:

No section at least 3 feet long between 28" and 34" provided at existing counter

Rec. Solution: Provide min. 3 ft long section of counter at max.  34" high

              Findings:

Service counter 42" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knobs not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,700.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 9

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 157

Page 163: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26J

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Hi/low Reach

Barrier  Description:

Use of control involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate to area at min. 15" or max. 48" high

              Findings:

Thermostat 62" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Pharmacy School Office 203

Barrier #: 26K

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 158

Page 164: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Restroom Entry Vestibule 215

Barrier #: 27A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ No Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces

Rec. Solution: Replace sign

              Findings:

No visual sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Restroom Entry Vestibule 215

Barrier #: 27B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ ISA at Accessible Restroom

Barrier  Description:

No ISA symbol on wall sign posted at accessible toilet room

Rec. Solution: Provide ISA symbol on restroom wall sign

              Findings:

No ISA sign provided at entry

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.8

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 159

Page 165: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Restroom Entry Vestibule 215

Barrier #: 27C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Front App/pull 18" SEC ‐ Blocked

Barrier  Description:

Door/Gate at pull side with min. 60" lacks min. 18" strike edge clearance at pull side

Rec. Solution: Move trash bin

              Findings:

Strike edge clearance reduced by trash bin

Quantity: ADMINI

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Figure 404.2.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Restroom Entry Vestibule 215

Barrier #: 27D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

63" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 160

Page 166: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Restroom Entry Vestibule 215

Barrier #: 27E

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

24‐1/2" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ ISA at Accessible Restroom

Barrier  Description:

No ISA symbol on wall sign posted at accessible toilet room

Rec. Solution: Provide ISA symbol on restroom wall sign

              Findings:

No ISA sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.8

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 161

Page 167: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ Location

Barrier  Description:

Braille/Tactile sign not mounted between 48" and 60" from floor

Rec. Solution: Provide Braille/tactile sign at latch side of door

              Findings:

No tactile wall sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

No closer where door needs to be self‐closing

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 162

Page 168: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Feminine product dispenser protrudes 5‐3/4" at 32‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/2" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 163

Page 169: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Clear Floor Space

Barrier  Description:

No clear floor space 30" x 48" at lavatory to allow forward approach

Rec. Solution: Relocate or replace lavatory

              Findings:

Table blocks lavatory clear floor space

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 164

Page 170: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28H

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Clear Floor Space ‐ 60" Turning Circle

Barrier  Description:

Clear floor space of min. 60" in diameter not provided where 360 degree turn is made

Rec. Solution: Remodel area to provide min. 60" turning space

              Findings:

56" between wall and lavatory

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $19,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 304.3.1

As‐built : 110

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Dispenser protrudes 9" into side transfer area

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 165

Page 171: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Rear Grab Bar

Barrier  Description:

Rear grab bar not centered 12" from wall and 24" on the other side of WC

Rec. Solution: Replace grab bars with reinforcement

              Findings:

10‐1/2" from wall

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser interferes with use of side grab bar

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

3/4" from side grab bar

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 609.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 166

Page 172: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Women's Accessible Restroom 215B

Barrier #: 28M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 167

Page 173: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ Location

Barrier  Description:

Braille/Tactile sign not mounted between 48" and 60" from floor

Rec. Solution: Provide Braille/tactile sign at latch side of door

              Findings:

Sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 168

Page 174: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

29" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/4" without bevel

Barrier  Description:

Door/Gate threshold exceeds 1/4" in height without a bevel

Rec. Solution: Provide new door threshold

              Findings:

Threshold damaged and has 1/2" lip at exit side

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 169

Page 175: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Sanitary Products

Barrier  Description:

Sanitary product dispenser not usable with a closed fist

Rec. Solution: Replace sanitary napkin dispenser

              Findings:

Dispenser not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $650.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Feminine product dispenser protrudes 48" at 32" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 170

Page 176: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/2" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 171

Page 177: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

48‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser protrudes 6‐1/4" at 54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 172

Page 178: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Height

Barrier  Description:

Dispenser control point or operating mechanism not max. 48" AFF

Rec. Solution: Remount no higher than 48" above floor

              Findings:

54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

24‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 173

Page 179: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Stall Door Hardware

Barrier  Description:

Stall door hardware involves tight grasping/pinching to close and no U‐pull provided

Rec. Solution: Provide U‐pull hardware on outside and inside of stall door

              Findings:

No U‐pulls on either side of door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Compartment door hardware  involves user to grasp or twist to operate

Rec. Solution: Provide hardware

              Findings:

Hardware not operable with a closed fist

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 174

Page 180: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

68" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser not within 7" to 9" from front edge of toilet

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

24‐1/2" from rim

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 175

Page 181: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Mul ‐accommoda on Toilet Room 215A

Barrier #: 29R

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 176

Page 182: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Doormat

Barrier  Description:

Doormat not anchored to floor (possible trip hazard)

Rec. Solution: Secure exiting doormat or replace

              Findings:

Door mat not secured

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 302.2 & Advisory 302.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 177

Page 183: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 178

Page 184: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30E

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Table at corner where refreshments are served has 26‐1/4" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Chalkboard/Whiteboard ‐ Area of Use

Barrier  Description:

Bottom edge of writing surface not max. 38" high

Rec. Solution: Remount whiteboard/chalkboard or provide alternate for use by short people

              Findings:

Lower edge of writing surface 46‐1/4" high from floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $1,200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard (2010 ADAS 904.3.3)

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 179

Page 185: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Clear Floor Space

Barrier  Description:

Clear floor space for wheelchair not provided at control or mechanism

Rec. Solution: Remodel area to provide wheelchair space at control or mechanism

              Findings:

Cabinet blocks whiteboard clear floor space

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 2 ‐ Conference Room 213

Barrier #: 30H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ No Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 3 of 6

ADA Assessment and Survey 2015 180

Page 186: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31A

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Permanent Room/Space

Barrier  Description:

No sign with raised characters and Braille at permanent room or space with visual sign

Rec. Solution: Provide sign at latch side of entry door, where possible

              Findings:

No tactile info on signs with visual information at 12 doors in corridor

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 12

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31B

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Side Reach

Barrier  Description:

Fire extinguisher forward or side reach exceeds 48"

Rec. Solution: Relocate fire extinguisher

              Findings:

52" high in two locations

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 181

Page 187: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31C

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

First aid kit  protrudes 4‐3/4" at 60" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31D

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

First aid kit  68" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 182

Page 188: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31E

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Sink protrudes 9‐1/4" into path of travel

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and  8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Replace cabinet and remount sink

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 183

Page 189: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Exposed Pipes

Barrier  Description:

Exposed hot water/drain pipes not insulated or configured so as to protect against contact

Rec. Solution: Provide insulation at drain pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $120.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink Faucet ‐ Operation

Barrier  Description:

Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist

Rec. Solution: Replace faucet

              Findings:

Faucet not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.4 & 309

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 184

Page 190: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31I

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Fire Alarm ‐ Pull Actuator Height

Barrier  Description:

Fire pulls not between 42" and 48" high

Rec. Solution: Replace fire pull when remodeling

              Findings:

63" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $7,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 2

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31J

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36"

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Demolish existing and construct new passageway

              Findings:

29‐1/2" wide circulation route in stairway at top where stairway narrows

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 185

Page 191: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31K

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Lift

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Provide a wheelchair lift with unassisted operation

              Findings:

Sign indicates user must call the college or public safety for assistance. Wheelchair lift provided has key operation

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $16,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31L

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Fist Operable

Barrier  Description:

Control or mechanism not usable with a closed fist

Rec. Solution: Replace operating control

              Findings:

No key provided at all 3 control boxes needed to enable travel

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 186

Page 192: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31M

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Vertical Access ‐ Lift

Barrier  Description:

No form of vertical access provided at stairway to reach upper floors

Rec. Solution: Replace wheelchair lift to reach upper floors

              Findings:

Ramp to lift sloped at 17.0% where no pit was provided at installation to ensure safe travel into lift

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.1

As‐built : 0

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31N

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Clear Floor Space

Barrier  Description:

Clear floor space for wheelchair not provided at control or mechanism

Rec. Solution: Replace wheelchair lift to reach upper floors

              Findings:

Ramp flare blocks clear floor space at side controls

Quantity: SF

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 0

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 187

Page 193: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31O

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Actuator/Control ‐ Fist Operable

Barrier  Description:

Control or mechanism not usable with a closed fist

Rec. Solution: Replace operating control

              Findings:

Controls not fist operable

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31P

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Visual Information Provided (Exhibitions)

Barrier  Description:

Visual sign providing information for program, service or activity not accessible

Rec. Solution: Provide information in alternate format to provide access to people with vision impairments

              Findings:

Visual information not provided in format usable for the visually impaired

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ADA Title II Technical Assistance Manual 3.2000 Denial of participation

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 188

Page 194: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31Q

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Display cases protrude 5‐1/2" ‐ 12" at 42" ‐ 44" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,100.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 2

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31R

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Photo gallery protrudes 24" at 36" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 189

Page 195: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31S

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Alcove ‐ Existing (pre‐1992)

Barrier  Description:

Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.

Rec. Solution: Provide wing walls as detectable warning (existing unit only)

              Findings:

No alcove provided

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31T

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Knee Clearance

Barrier  Description:

Knee clearance under fountain not min. 27" high

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

26‐3/4" high knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 190

Page 196: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31U

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Spout Location

Barrier  Description:

Spout not located at max. 5" from rim or max 15" from backsplash

Rec. Solution: Replace fountain with accessible unit

              Findings:

Water spigot 12" deep and 42" high over 40" obstruction

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Central Corridor

Barrier #: 31V

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $11,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 2

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 191

Page 197: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Location ‐ 48" to 60" high

Barrier  Description:

Braille/Tactile information on sign not mounted between 48" and 60" from ground or floor

Rec. Solution: Provide Braille/tactile sign at latch side of door

              Findings:

Tactile sign not mounted properly

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32B

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Braille ‐ Distance from Characters

Barrier  Description:

Braille not 3/8" and max. 1/2" directly below the tactile characters

Rec. Solution: Provide accessible sign

              Findings:

Braille is 1‐1/4" from raised characters

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.3

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 192

Page 198: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 193

Page 199: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Provide automatic door opening device

              Findings:

4 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door 10" Bottom Surface ‐ Door Hardware

Barrier  Description:

Door hardware interrupts min. 10" smooth bottom surface

Rec. Solution: Remove element at bottom of door at push side

              Findings:

Door hardware extends into bottom 10" of door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.10

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 194

Page 200: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32G

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Door

Barrier  Description:

Ground floor doors that exit to exterior lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT” at exit side of door

              Findings:

Exit door with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.4.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Protruding Object ‐ Wall‐mounted

Barrier  Description:

Wall mounted object protrudes more than 4" from wall

Rec. Solution: Remove object or provide detectable warning for the visually impaired

              Findings:

Emergency phone protrudes 20" at 48" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 195

Page 201: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Podium  ‐ Surface Height

Barrier  Description:

Surface height exceeds 34" high

Rec. Solution: Provide min. 1 accessible  podium

              Findings:

42" surface height

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32J

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Instructional table has 24" knee clearance

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 196

Page 202: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32K

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Accessible Route ‐ Remodel

Barrier  Description:

Clear floor space does not adjoin an accessible route or another space

Rec. Solution: Provide ISA directional sign indicating location of ramp to upper level of dias

              Findings:

6‐1/2" step blocks access to instructional dias

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $175.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32L

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Ramp Landing ‐ Top Landing

Barrier  Description:

Top landing is not min. 60" long

Rec. Solution: Demolish existing and construct new ramp

              Findings:

48" bottom landing length due to stored items

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $200.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 405.7.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 197

Page 203: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32M

X Coordinate: N/A

Barrier Area: Ramps

Barrier Type: Handrail

Barrier  Description:

No handrail provided at both sides

Rec. Solution: Replace handrails at both sides of ramp

              Findings:

Ramp lacks handrail at both sides

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 505.2

As‐built : 10

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32N

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Podium ‐ Knee Clearance

Barrier  Description:

Podium knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible  podium

              Findings:

Podium has shelf blocking knee clearance space with phone at 12" high

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 504.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 198

Page 204: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32O

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Desk ‐ Ratio

Barrier  Description:

At least 1 desk or 5% of all desks not accessible

Rec. Solution: Provide min. 6 accessible desks (5 additional desks)

              Findings:

184 total seats with 1 desk identified as accessible

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $4,375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 5

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 302

Barrier #: 32P

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ No Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 199

Page 205: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Restroom Entry Vestibule 304

Barrier #: 33A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Location ‐ Suspended

Barrier  Description:

Suspended or projecting sign lacks min. character height of 2"

Rec. Solution: Provide accessible sign

              Findings:

Accessible sign not provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Table 703.5.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/1/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Restroom Entry Vestibule 304

Barrier #: 33B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ ISA at Accessible Restroom

Barrier  Description:

No ISA symbol on wall sign posted at accessible toilet room

Rec. Solution: Provide ISA symbol on restroom wall sign

              Findings:

No tactile wall sign provided at entry

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.8

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 200

Page 206: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Restroom Entry Vestibule 304

Barrier #: 33C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Electrical Outlets

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor

Rec. Solution: Relocate outlet to area with max. 15 low reach

              Findings:

13" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 205.1 & 309.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Restroom Entry Vestibule 304

Barrier #: 33D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Electrical Switches

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

49" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 205.1 & 309.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 201

Page 207: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Restroom Entry Vestibule 304

Barrier #: 33E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Sign ‐ Braille Location

Barrier  Description:

Braille not 3/8" and max. 1/2" directly below the tactile characters

Rec. Solution: Replace signage

              Findings:

1/4" from raised characters

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 202

Page 208: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

Hook on door 62" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Closer ‐ Interior Automatic Door

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Provide automatic door opening device

              Findings:

No closer where door needs to be self‐closing

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,000.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 203

Page 209: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/3" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/3" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 204

Page 210: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Maneuvering Clearance

Barrier  Description:

No 60" turning circle provided in toilet facility (min. 27" high above floor)

Rec. Solution: Remodel toilet room

              Findings:

56" space between wall and lavatory

Quantity: SF

Notes:

Barrier Severity: 2 Recommended Cost Est $575.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 205

Page 211: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Dispenser protrudes 9" into side transfer area

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet ‐ Rear Grab Bar

Barrier  Description:

Rear grab bar not centered 12" from wall and 24" on the other side of WC

Rec. Solution: Replace grab bars with reinforcement

              Findings:

10‐1/2" from wall

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.5.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 206

Page 212: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser interferes with use of side grab bar

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

3/4" from side grab bar

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 609.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Centerline

Barrier  Description:

Water closet centerline not between 16" and 18" O. C.

Rec. Solution: Relocate water closet

              Findings:

18‐1/2" on center

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $850.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 207

Page 213: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Women's Accessible Restroom 307B

Barrier #: 34M

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 208

Page 214: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35A

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

29" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35B

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Knee Clearance

Barrier  Description:

Lavatory bottom apron/edge not at least 27" high

Rec. Solution: Replace lavatory

              Findings:

25‐1/2" knee clearance

Quantity: JOB

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 209

Page 215: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35C

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Lavatory ‐ Drainpipes

Barrier  Description:

Hot water and drainpipes accessible under lavatory not insulated or covered

Rec. Solution: Insulate drainpipes and hot water pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $220.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35D

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Mirror

Barrier  Description:

Mirror at lavatory/countertop not max. 40" AFF at edge of reflecting surface

Rec. Solution: Replace or remount mirror

              Findings:

49" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $375.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 210

Page 216: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35E

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Dispensers ‐ Protruding Object

Barrier  Description:

Protruding dispenser creates protruding hazard in path of travel

Rec. Solution: Relocate dispenser or provide cane‐detectable warning

              Findings:

Paper towel dispenser protrudes 6‐1/4" at 54‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35F

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Protruding Hazard

Barrier  Description:

Object protrudes more than 4" into pedestrian way

Rec. Solution: Provide detectable warning

              Findings:

Shelf protrudes 12" at 62‐1/2" high

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 211

Page 217: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35G

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Urinal ‐ Rim

Barrier  Description:

Urinal not max. 17" above the floor

Rec. Solution: Provide min. 1 accessible urinal

              Findings:

22" high rim

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $800.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 605.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35H

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Door Clear Width

Barrier  Description:

Door clear width is not min. 32"

Rec. Solution: Replace door/gate and frame

              Findings:

24‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 212

Page 218: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35I

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Inside of compartment door lacks a loop or U‐pull below latch

Rec. Solution: Provide hardware

              Findings:

No U‐pull provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35J

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Outside of compartment door lacks a loop or U‐pull below latch

Rec. Solution: Provide hardware

              Findings:

No U‐pull provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $75.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 213

Page 219: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35K

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Stall ‐ Door Hardware

Barrier  Description:

Compartment door hardware  involves user to grasp or twist to operate

Rec. Solution: Provide hardware

              Findings:

Hardware not operable with a closed fist

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.8.1.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35L

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Coat Hook

Barrier  Description:

Clothing hooks not max. 48" high AFF

Rec. Solution: Provide additional hook in new location

              Findings:

68" high

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 603.4

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 214

Page 220: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35M

X Coordinate: N/A

Barrier Area: Clear Floor Space

Barrier Type: Passageway ‐ Min. 36"

Barrier  Description:

Circulation route not min. 36" wide between elements

Rec. Solution: Demolish existing and construct new passageway

              Findings:

36" wide circulation route

Quantity: LF

Notes:

Barrier Severity: 1 Necessary Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 403.5.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35N

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser not within 7" to 9" from front edge of toilet

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

24" from rim

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 215

Page 221: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35O

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Toilet Paper Dispenser

Barrier  Description:

Toilet tissue dispenser not easily reachable from toilet seat

Rec. Solution: Reposition or  replace toilet paper dispenser

              Findings:

24‐1/2" from rim

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 604.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35P

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Seat Cover Dispenser

Barrier  Description:

Seat cover dispenser not located on an accessible route. Blocked by water closet

Rec. Solution: Replace or remount dispenser on an accessible route with clear floor space

              Findings:

Access to dispenser blocked by water closet

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $125.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 216

Page 222: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Multi‐accommodation Women's Toilet Room 30

Barrier #: 35Q

X Coordinate: N/A

Barrier Area: Restrooms

Barrier Type: Alarm ‐ Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe in sanitary facility

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible sign

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 217

Page 223: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 218

Page 224: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36D

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Electrical Switches ‐ High Unobstructed

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36E

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Clear Floor Space ‐ Stored Elements

Barrier  Description:

Clear floor space for wheelchair not provided at control or mechanism

Rec. Solution: Move trash bin

              Findings:

Trash bin blocks switch clear floor space

Quantity: JOB

Notes:

Barrier Severity: 3 Hindrance Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 219

Page 225: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Workstation ‐ Surface Max. 34"

Barrier  Description:

Workstation surface height exceeds 34" high

Rec. Solution: Provide min. 1 accessible workstation of each type or overall 5%

              Findings:

Overhead projector surface 36‐1/4" and controls 38" where surface should be max. 34" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $875.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 902

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36G

X Coordinate: N/A

Barrier Area: Counters and Tables

Barrier Type: Table ‐ Knee Clearance

Barrier  Description:

Knee clearance not min. 27" high, 19" deep or 30" wide

Rec. Solution: Provide min. 1 accessible table. Avoid pedestal base tables.

              Findings:

Instructor's table has knee clearance 22" high and 13" deep

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 220

Page 226: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Accessible Route ‐ Remodel

Barrier  Description:

Clear floor space does not adjoin an accessible route or another space

Rec. Solution: Remodel area to provide connection to accessible route

              Findings:

No passage through seating to reach pencil sharpener

Quantity: JOB

Notes:

Barrier Severity: 2 Recommended Cost Est $175.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/2/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Classroom 324

Barrier #: 36I

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Alarm ‐ No Horn/Strobe

Barrier  Description:

Where a fire alarm is installed, no horn/strobe provided

Rec. Solution: Provide horn/strobe

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 221

Page 227: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Knob on stairway side of entry side door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 222

Page 228: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37D

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No sign provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 223

Page 229: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37E

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Switches ‐ Height

Barrier  Description:

Light switch control box top edge not at max. 48" high

Rec. Solution: Relocate switch box top edge to max. 48" high

              Findings:

50‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37F

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

12‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 224

Page 230: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Contrasting Color ‐ ADA

Barrier  Description:

No contrasting color on each tread of interior stairway

Rec. Solution: Recommended: Consider providing contrasting color on each tread

              Findings:

Treads lack contrasting color defined as 70% contrast

Quantity: LF or TR

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS Advisory 504.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Southeast Exit Stairway

Barrier #: 37H

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 225

Page 231: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 226

Page 232: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

18 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 227

Page 233: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/2"

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide new door threshold

              Findings:

Metal door threshold 1/2" without a bevel at exit side of door to rescue area

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 228

Page 234: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Northeast Exit Stairway

Barrier #: 38G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Elevator

Barrier #: 39A

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ 42" High

Barrier  Description:

The centerline of the hall call buttons not max. 42" above the floor

Rec. Solution: Replace hall call buttons

              Findings:

53" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 229

Page 235: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Elevator

Barrier #: 39B

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Sign at Call Station

Barrier  Description:

Sign stating "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS" not provided with tactile information

Rec. Solution: Replace sign

              Findings:

Evacuation sign not tactile

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Elevator

Barrier #: 39C

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall lanterns ‐ Audible Direction

Barrier  Description:

Audible signal does not sound once for the up direction and twice for the down direction 

Rec. Solution: Replace hall lanterns

              Findings:

No audible controls provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,675.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 230

Page 236: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ Elevator

Barrier #: 39D

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Visual Car Position indicator

Barrier  Description:

Visual car position indicator does not show the position of the elevator in the hoistway

Rec. Solution: Replace car controls

              Findings:

No indication of travel within lobby

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.8

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 231

Page 237: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 232

Page 238: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace closer or provide automatic door opening device

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 233

Page 239: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40F

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Protruding Hazard

Barrier  Description:

Fire extinguisher protrudes into circulation path more than 4" between 27" and 80"

Rec. Solution: Remount extinguisher with leading edge below 27" or provide detectable warning

              Findings:

Fire extinguisher creates a protruding hazard

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40G

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 234

Page 240: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40H

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $2,700.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 12

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Clear width passage through door, sliding/folding door or gate is not min. 32"

Rec. Solution: Replace door or gate and frame

              Findings:

29‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 235

Page 241: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40J

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40K

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 236

Page 242: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40L

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 3 ‐ North Exit Stairway

Barrier #: 40M

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 4 of 6

ADA Assessment and Survey 2015 237

Page 243: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Permanent Room/Space ‐ Tactile Characters

Barrier  Description:

No tactile characters at sign identifying permanent rooms and spaces with visual signs

Rec. Solution: Provide accessible signs at 5 doors in corridor

              Findings:

No tactile signage provided at door within public route

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $1,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 216.2

As‐built : 5

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41B

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Extinguisher ‐ Side Reach

Barrier  Description:

Fire extinguisher forward or side reach exceeds 48"

Rec. Solution: Relocate fire extinguisher

              Findings:

52" high

Quantity: JOB

Notes:

Barrier Severity: 4 Low Severity Cost Est $1,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 308.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 238

Page 244: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41C

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

First aid kit  protrudes 4‐3/4" at 60" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41D

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Actuator/Control ‐ Side Reach High Unobstructed

Barrier  Description:

Control or mechanism not at min. 15" or max. 48" high

Rec. Solution: Relocate control or mechanism to min. 15" or max. 48" high

              Findings:

First aid kit  68" high

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 239

Page 245: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41E

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Alcove ‐ Existing (pre‐1992)

Barrier  Description:

Fountain with a leading edge between 27" and 80" high protrudes more than 4" into the circulation path.

Rec. Solution: Provide wing walls as detectable warning (existing unit only)

              Findings:

Sink protrudes 9‐1/4" without an alcove

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41F

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Knee Clearance

Barrier  Description:

Knee clearance of at least 30" wide and  8" deep at 27" high with 11" depth at 9" high

Rec. Solution: Replace cabinet and remount sink

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.2 & 306

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 240

Page 246: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41G

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink ‐ Exposed Pipes

Barrier  Description:

Exposed hot water/drain pipes not insulated or configured so as to protect against contact

Rec. Solution: Provide insulation at drain pipes

              Findings:

No insulation provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $120.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41H

X Coordinate: N/A

Barrier Area: Classrooms

Barrier Type: Sink Faucet ‐ Operation

Barrier  Description:

Faucets lack controls and operating mechanisms involve tight grasping, pinching or twisting of the wrist

Rec. Solution: Replace faucet

              Findings:

Faucet not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 606.4 & 309

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 241

Page 247: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41I

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Fire Pull ‐ Operation

Barrier  Description:

Fire pull has no fist operable hardware

Rec. Solution: Replace fire pull when remodeling

              Findings:

Fire pull not fist operable

Quantity: EACH

Notes:

Barrier Severity: 4 Low Severity Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 309.4

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41J

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Knee Clearance

Barrier  Description:

Knee clearance under fountain not min. 27" high

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

No knee clearance

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 306.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 242

Page 248: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41K

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Bubbler height

Barrier  Description:

Bubbler height exceeds 36"

Rec. Solution: Replace drinking fountain with accessible unit or remount existing

              Findings:

42" bubbler height

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.4

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41L

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Operation ‐ Replacement

Barrier  Description:

Operating mechanism involves more than 5 lbf to operate

Rec. Solution: Replace drinking fountain with accessible unit 

              Findings:

Needed more than 5 lbf where fountain is not adjustable

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 602.3

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 243

Page 249: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41M

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: Hi‐Low Unit

Barrier  Description:

No hi‐low drinking fountain provided on each floor of building

Rec. Solution: Provide min. one hi‐low fountain on each floor

              Findings:

No low fountain provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $0.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 211.2 & 602.7

As‐built : 0

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41N

X Coordinate: N/A

Barrier Area: Drinking Fountains

Barrier Type: ISA at Non‐Acc Fountain

Barrier  Description:

Non‐accessible fountain lacks ISA directional sign

Rec. Solution: Provide ISA directional sign to accessible fountain

              Findings:

No ISA sign provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 244

Page 250: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41O

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Protruding Object

Barrier  Description:

Protruding object in in circulation path protrudes more than 4" between 27" and 80" high

Rec. Solution: Remove object or provide detectable warning (wing walls)

              Findings:

Electrical panel protrudes 5" at 40" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Central Corridor

Barrier #: 41P

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 245

Page 251: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 246

Page 252: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

14 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

3 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 247

Page 253: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/2"

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide new door threshold

              Findings:

Metal door threshold 1/2" without a bevel at exit side of door to rescue area

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Knob at stairway side of door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 248

Page 254: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Northeast Exit Stairway

Barrier #: 42G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Elevator

Barrier #: 43A

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ 42" High

Barrier  Description:

The centerline of the hall call buttons not max. 42" above the floor

Rec. Solution: Replace hall call buttons

              Findings:

53‐1/2" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 249

Page 255: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Elevator

Barrier #: 43B

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons

Barrier  Description:

Hall call buttons not internally illuminated with a white light over the entire button surface

Rec. Solution: Replace hall call buttons

              Findings:

Hall call buttons not internally illuminated

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.5

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Elevator

Barrier #: 43C

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Sign at Call Station

Barrier  Description:

Sign stating "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS" not provided with tactile information

Rec. Solution: Replace sign

              Findings:

Evacuation sign not tactile

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 250

Page 256: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Elevator

Barrier #: 43D

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Audible Signals

Barrier  Description:

Audible signals or verbal announcement does not sound when the car passes a floor or stops

Rec. Solution: Replace car controls

              Findings:

No audible controls provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/3/2015 Report Date 11/16/2015

Location: Floor 4 ‐ Elevator

Barrier #: 43E

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Visual Car Position indicator

Barrier  Description:

Visual car position indicator does not show the position of the elevator in the hoistway

Rec. Solution: Replace car controls

              Findings:

No indication of travel within lobby

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.8

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 251

Page 257: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 252

Page 258: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

14 Lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 253

Page 259: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $2,700.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 12

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Protruding Hazard

Barrier  Description:

Object protrudes more than 4" into pedestrian way

Rec. Solution: Rework area to remove hazard

              Findings:

Fire riser protrudes 10" into pedestrian way

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $550.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 307.2

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 254

Page 260: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44G

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44H

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height 1/2" with Ramp

Barrier  Description:

Door/Gate threshold bevel at max 1/2" lip exceeds 1:2 or 50% slope

Rec. Solution: Provide ramp leading to new level landing at door

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $2,700.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 12

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 255

Page 261: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44I

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Clear width passage through door, sliding/folding door or gate is not min. 32"

Rec. Solution: Replace door or gate and frame

              Findings:

29‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44J

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

11 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 256

Page 262: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44K

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44L

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

ADA Assessment and Survey 2015 257

Page 263: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 4 ‐ North Exit Stairway

Barrier #: 44M

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 5 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45A

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Sign ‐ Permanent Room/Space

Barrier  Description:

No sign with raised characters and Braille at permanent room or space with visual sign

Rec. Solution: Provide signs at latch side of entry doors in two locations, where possible

              Findings:

No tactile info on sign with visual information

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 703.1

As‐built : 2

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 258

Page 264: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45B

X Coordinate: N/A

Barrier Area: Controls and Mechanisms

Barrier Type: First Aid Kit ‐ High Reach Range

Barrier  Description:

Opening mechanism on first aid kit not at max. 48" high for side reach

Rec. Solution: Relocate control or mechanism to max. 48" high

              Findings:

First aid kit control at 68" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS  305.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45C

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Electrical Outlets ‐ Hi/Low Reach

Barrier  Description:

Use of outlet involves low reach of less than 15" above floor or more than 48" high

Rec. Solution: Relocate outlet to area at min. 15" or max. 48" high

              Findings:

12‐1/2" high

Quantity: LF

Notes:

Barrier Severity: 2 Recommended Cost Est $225.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 205.1 & 309.3

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 259

Page 265: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45D

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Passage

Barrier  Description:

Exit thru an exit enclosure/exit passageway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT ROUTE” at exit side of door

              Findings:

Passageway to exterior exit with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 260

Page 266: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Central Corridor

Barrier #: 45F

X Coordinate: N/A

Barrier Area: Corridors

Barrier Type: Strobe

Barrier  Description:

No strobe provided in corridor where horn is provided where fire alarm exists in building

Rec. Solution: Provide strobe in common use area

              Findings:

No strobe where horn is provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 261

Page 267: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Vision Lights ‐ Existing

Barrier  Description:

View panels in or adjacent to doors or gates not max. 43" above floor or ground

Rec. Solution: Replace door/gate or vision panel

              Findings:

View panel located higher than 43" above the floor

Quantity: EACH

Notes:

Barrier Severity: 3 Hindrance Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.11

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 262

Page 268: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Height exceeding 1/4" without bevel

Barrier  Description:

Door/Gate threshold exceeds 1/4" in height without a bevel

Rec. Solution: Provide new door threshold

              Findings:

Metal door threshold 1/2" without a bevel at exit side of door

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $275.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 263

Page 269: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46F

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile sign provided. Existing sign is intended for emergency personnel

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Northeast Exit Stairway

Barrier #: 46G

X Coordinate: N/A

Barrier Area: Alarms

Barrier Type: Horn/Strobe ‐ Common Use Area

Barrier  Description:

No horn/strobes in common use areas

Rec. Solution: Provide strobe in common use area

              Findings:

No device provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $5,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 702.1

As‐built : 1

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 264

Page 270: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Elevator

Barrier #: 47A

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall Call Buttons ‐ 42" High

Barrier  Description:

The centerline of the hall call buttons not max. 42" above the floor

Rec. Solution: Replace hall call buttons

              Findings:

53‐1/4" high

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,500.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Elevator

Barrier #: 47B

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Emergency Sign at Call Station

Barrier  Description:

Sign stating "IN FIRE EMERGENCY, DO NOT USE ELEVATOR. USE EXIT STAIRS" not provided with tactile information

Rec. Solution: Replace sign

              Findings:

Evacuation sign not tactile

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard & 2010 ADAS 703.1

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 265

Page 271: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Elevator

Barrier #: 47C

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Hall lanterns ‐ Audible Direction

Barrier  Description:

Audible signal does not sound once for the up direction and twice for the down direction 

Rec. Solution: Replace hall lanterns

              Findings:

No audible controls provided

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $3,675.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.2.2.2

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ Elevator

Barrier #: 47D

X Coordinate: N/A

Barrier Area: Elevators

Barrier Type: Visual Car Position indicator

Barrier  Description:

Visual car position indicator does not show the position of the elevator in the hoistway

Rec. Solution: Replace car controls

              Findings:

No indication of travel within lobby

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $2,750.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 407.4.8

As‐built : 1

Facility Function: Public

Implementation Priority: 2

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 266

Page 272: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48A

X Coordinate: N/A

Barrier Area: Signage

Barrier Type: Tactile Exit Signs ‐ Stairway

Barrier  Description:

Door leading directly into an exit stairway lacks tactile exit sign

Rec. Solution: Provide sign stating “EXIT STAIR DOWN (or UP)” at latch side of door

              Findings:

Door to exit stair with low level illuminated sign lacks tactile exit sign

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

Performance Standard

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: Yes

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48B

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Hardware ‐ Operation

Barrier  Description:

Hardware not operable with a closed fist

Rec. Solution: Provide new hardware

              Findings:

Door knob not fist operable

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $300.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.7

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 267

Page 273: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48C

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Threshold ‐ Ramp

Barrier  Description:

Door/Gate threshold exceeds 1/2" in height

Rec. Solution: Provide ramp leading to new level landing at door 

              Findings:

4" high threshold

Quantity: SF

Notes:

Barrier Severity: 1 Necessary Cost Est $2,700.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.5

As‐built : 12

Facility Function: Public

Implementation Priority: 1

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48D

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Adjustment

Barrier  Description:

Door opening force exceeds 5 lbf

Rec. Solution: Replace or adjust existing  closer

              Findings:

12 lbf

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $450.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.9

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 268

Page 274: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48E

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Door Closer ‐ Interior Sweep Period

Barrier  Description:

Door closer lacks min. 5 second sweep period or does not stop 5" from door frame

Rec. Solution: Replace or adjust existing  closer

              Findings:

2 second sweep

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.8.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48F

X Coordinate: N/A

Barrier Area: Doors or Gates

Barrier Type: Clear Width

Barrier  Description:

Clear width passage through door, sliding/folding door or gate is not min. 32"

Rec. Solution: Replace door or gate and frame

              Findings:

29‐1/2" clear width

Quantity: EACH

Notes:

Barrier Severity: 1 Necessary Cost Est $2,250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

2010 ADAS 404.2.3

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 269

Page 275: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

OSU ‐ PHARMACY BUILDING 

Field Date:  11/4/2015 Report Date 11/16/2015

Location: Floor 5 ‐ North Exit Stairway

Barrier #: 48G

X Coordinate: N/A

Barrier Area: Stairways

Barrier Type: Sign ‐ Enclosed Exit Stairway Level

Barrier  Description:

Tactile stairway signage not provided to indicate floor level

Rec. Solution: Provide sign

              Findings:

No tactile stair ID sign inside stairway

Quantity: EACH

Notes:

Barrier Severity: 2 Recommended Cost Est $250.00

Implementation Date:

Status: Open

Implementation Phase:

Code References:

ICC A117.1

As‐built : 1

Facility Function: Public

Implementation Priority: 3

Bldg Name: Pharmacy Building

Y Coordinate: N/A

Performance Standard: No

Reference Dwg: 6 of 6

ADA Assessment and Survey 2015 270

Page 276: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

COST ESTIMATE SUMMARY

Page 277: OREGON STATE UNIVERSITY (OSU) · elevator. The only elevator in building is designated as a freight elevator, and signage placed inside the elevator specifically states that it is

SUMMARY REPORT

Cost Estimate Total $942,750.00

Cost Estimate ‐ Priority 1: $235,775.00

Cost Estimate ‐ Priority 2: $284,060.00

Cost Estimate ‐ Priority 3: $422,915.00

% of Total Cost Estimate: 25.01%

% of Total Cost Estimate: 30.13%

% of Total Cost Estimate: 44.86%

ADA Assessment and Survey 2015 271