Most Common Validation ErrorsIdenti Fy Frequent Deficiencies To Accelerate Your Validation Projects

(Based on Frank Houston research)

May 2010

QPack™Application Lifecycle Management

Page 2: Orcanos medical-common-validation-errors

About Orcanos• Develop and implement QPack Medical ALM system• Expert in Application lifecycle management• Leading ALM 2.0 and CFR 21 Part 11 Forums • Over 50 installations• Industry based solutions: Software/Medical Device/Semiconductors

• Siemens Business and Technology partners• Oracle partner (OEM)• Offices: Israel, UK, Germany

Page 4: Orcanos medical-common-validation-errors

Working Without ALM SystemMarket Definition Develop Test

Test Results

9 Most Common validation Errors

• Missing Information

• Inconsistency

• Lack of Needed Detail

• Traceability

• Vague Wording

• Unverifiable Test Results

• GDP

• Incomplete Testing

• Ambiguity

Page 5: Orcanos medical-common-validation-errors

QPack Application Lifecycle Management

MarketGathering Design Test

Plan

TestExecution

Delivery

DefinitionRequirementDefinition

1.0

2.0

DefectReporting

CustomerFacing

Market Definition Develop Test

Risk Mng.

Page 6: Orcanos medical-common-validation-errors

QPack ALM Solution

Marketing Requirements

Product Requirements Tasks

TestPlan

Test Execution

Project Management

RiskManagement Defects

Tracking

QPack

ALM ANALYTICS

SOA

Teamcenter PLM

Page 7: Orcanos medical-common-validation-errors

Lessons Learned from 1,720 Observations• The goal was to bring the company’s software validation

evidence up to the level of the U.S. FDA expectation.• Identified which documents most frequently contains errors• The results are typical problems most companies face• Applying Pareto Analysis• Finds 9 Types of deficiencies representing about 41% of

categories

Page 8: Orcanos medical-common-validation-errors

Missing Information

• Documents or records omitted fundamental information or content that should have been included.

– Compliancy to specific standards– Missing other engineering information HW & Mechanics

Page 9: Orcanos medical-common-validation-errors

Inconsistency

• Documents contained statements inconsistent with other statements about the same topic in the same document or in the same validation package.

– Jargon– Varying Terminology– Contradiction in logic

Page 10: Orcanos medical-common-validation-errors

Lack of Needed Detail

• This deficiency applied mostly to requirements documents. The requirements in the validation package did not adequately describe the software.

– Poor requirements documents• Data• User Interaction• Key process

Page 11: Orcanos medical-common-validation-errors

Traceability

• 3 frequent traceability problems:

– The traceability matrix did not account for a traceable specification or an observation step in a test script

– Broken trace (Barren or Orphans)– Requirement details were not explicitly numbered and

traced to associated test steps.

Page 12: Orcanos medical-common-validation-errors

Vague Wording

• Documents used generalities

– “in accordance to an approved procedure”, or “applicable regulatory requirements”, or “all associated GxP and business processes”

– vague words such as “may”, “possibly”, “more or less”, and “approximately”

Page 13: Orcanos medical-common-validation-errors

Unverifiable Test Results

• Expected results were not described sufficiently so that an independent reviewer could compare and verify actual results. The IEEE Standard for Software Test documentation, Std. 829.1988, Clause 6.2.4 says you should, “...provide the exact value (with tolerances where appropriate) for each required output or feature”

– For executed scripts, actual results were not recorded or captured in a way that allowed an independent reviewer to compare them to expected results.

– Actual-result column with no reference to a screen shot

Page 14: Orcanos medical-common-validation-errors

GDP

• 3 frequent Good Documentation Practice problems:

– Hand-recorded data and testing evidence, such as test results, were presented in a way that could cause doubts about their authenticity (Ex. Cross-Out)

– Data that confirmed a specific requirement was hard to find in the evidence provided (for example, a busy screen shot crammed with data).

– Handwritten corrections were made that changed the sense of a requirement or an expected test result

Page 15: Orcanos medical-common-validation-errors

Incomplete Testing

• Test scripts did not fully or adequately test the associated requirement.

Page 16: Orcanos medical-common-validation-errors

Ambiguity

• Text could be interpreted more than one way– The words “either” and “or” in a requirement are strong

clues the text is ambiguous.

Page 17: Orcanos medical-common-validation-errors

Identifying the Most Vulnerable Documents

• categorized the documents and records where most frequent deficiencies were found. They discovered that about 85% of findings were concentrated in six key documentation areas

Page 18: Orcanos medical-common-validation-errors

User dashboardPersonalized views

Easily add charts, and filters

Page 19: Orcanos medical-common-validation-errors

Full Coverage matrix

Page 20: Orcanos medical-common-validation-errors

Risk Management (FMEA)• Reduce project risk• Relate risk objects to ALM artifacts• Generate Risk Management Document• Easily track high-risk features

Page 21: Orcanos medical-common-validation-errors

Advanced ALM Analytics - BI• Include external data sources• Personalize your own dashboard• drill down reports

Page 22: Orcanos medical-common-validation-errors

Thank Youwww.orcanos.com