PALADON SYSTEMS LIMITED OPERATING AND MAINTENANCE INSTRUCTIONS CUSTOMER KOSSO KENT INTROL LTD CUSTOMER ORDER NUMBER P234314 PROJECT ALVHEIM PALADON REF. CPC15815 DOCUMENT NO. 15815OM

Upload: others

Post on 08-Sep-2019

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

PALADON SYSTEMS LIMITED OPERATING AND MAINTENANCE

INSTRUCTIONS

CUSTOMER KOSSO KENT INTROL LTD CUSTOMER ORDER NUMBER P234314 PROJECT ALVHEIM PALADON REF. CPC15815 DOCUMENT NO. 15815OM

Page 2: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

INDEX

Drawing Index ................................................................................................................... 3

Equipment Specification .................................................................................................... 4

Actuator General Specification .......................................................................................... 4 Paladon Hydraulic Double Acting Linear Actuator....................................................................... 4 Valve/Actuator Mounting Assembly ............................................................................................ 4

PS-125-DA Actuator Specification ..................................................................................... 5 Actuator Controls ............................................................................................................... 5

Specification for Electro/Hydraulic Control System ..................................................................... 5 Specification for Electronic Positioner ........................................................................................ 5 Paint Specification ..................................................................................................................... 6 Hydraulic Circuit & Operation Description ................................................................................... 7

Spares Kit Ordering & Additional Service Support ................................................................. 8

Page 3: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Drawing Index GA DRAWINGS

TAG NO. CPC15815-02-01 Rev 0 16HCC0104 16HCV0404 HYDRAULIC CONTROL SCHEMATIC CPC15815-05-02 R0 WIRING DIAGRAM CPC15815-05-201 R1 CPC15815-05-202 R1

Page 4: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Equipment Specification Actuator General Specification Paladon Hydraulic Double Acting Linear Actuator The Paladon hydraulic double acting actuator incorporates the latest technology for the cylinder and yoke mechanisms. All steel construction means that these units are designed for the most arduous of operating conditions and are guaranteed to provide extended service life. Actuators for modulating service include heavy-duty bearings and seals. Main Actuator Features - ENP coated cylinders with external tie bars where applicable. - Circular apertures sealed by 'O' rings. - Heavy-duty piston rod operating in sleeve bearings ensure no degradation of sealing

surfaces due to working loads. Actuators incorporate a central guide rod which supports the combined piston and guide pin assembly throughout the stroke cycle.

- All critical nuts and bolts are positively locked. - Adjustable end stops are provided for external adjustment and locking. - Standard operating temperatures -20°C to +55°C. - A mechanical position indicator is provided on each actuator. Materials of Construction Housing : Carbon Steel Piston Rod : Alloy Steel, Chromium plated 'O' Rings : Buna-N Fasteners : Stainless Steel Valve/Actuator Mounting Assembly A heavy-duty valve/actuator mounting assembly is provided to give a true running accurate transmission of thrust and properly aligned with a secure mounting arrangement.

Page 5: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

PS-125-DA Actuator Specification For ABB choke Valve - 100mm Travel Double Acting Hydraulic Linear Actuator Thrust To Close/Open : 19000 lbs Operating time (stepping): Adjustable (1min to 15min) Operating time (fast open): Approx. 10 sec Extras Included • Mounting Yoke and Drive Coupling • Adjustable end stop

Actuator Controls The actuator is fitted with the following controls, all tested as necessary in accordance with PALADON procedures. Specification for Electro/Hydraulic Control System Actuator Type Linear, Double Acting Modes of Operation Stayput Construction Manifold Design 316 SS Solenoid Operated Valve 24vDC EExd ATEX Approved Speed Control Fully Adjustable Hydraulic Supply From customer’s ring main supply

Normal Pressure Range 180 barg min and 210 barg max

System Leakage Zero to maintain accurate positioning Environment Exposed Ambient Temperature -20ºC to +55ºC Operating Medium Mineral Oil System Cleanliness NAS 1638 Class 6 Extras Included: 316 SS Enclosure

Pressure Filter with Pop-Up Indicator Hand pump for Manual Override Fast Open Solenoid Valve

Specification for Feedback and Electrics Mode of Operation Pulsing Solenoids Feedback Housing Material 316 SS Feedback Certification Intrinsically Safe Retransmission Signal 4-20 mA Terminal Box for Solenoids EExe Terminal Box Material 316 SS Ambient Temperature -20ºC to +55ºC Environment Exposed Electrical Connections 1/2” NPT Electrical Cabling Armour braided fire resistant and halogen free Cable Glands EExd Brass Universal with PVC Shroud

Page 6: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Paint Specification Norsok M-501 System 1 Final Colour RAL7038 Agate Grey

Page 7: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

PALADON SYSTEMS LIMITED OPERATING AND MAINTENANCE

INSTRUCTIONS Hydraulic Circuit & Operation Description Electro Hydraulic Positional Control System – Stayput & Manual Override c/w Fast Open & Valve Close Lock Operation Description for Circuit Diagram CPC15815-05-02 Hydraulic fluid is supplied from a centralised source at a pressure of 180 barg into the actuator hydraulic system. Maximum operating pressure 210 barg. Cleanliness protection of the fluid is maintained at a level of NAS 1638 class 6 by means of the pressure filter c/w pop up indicator (Item 2). On loss of 24V Power Supply or Hydraulic Supply Pressure the system will fail Stayput. The Customer’s DCS will control two Electro-Hydraulic solenoid valves (Items 9 & 10) to position the hydraulic actuator (Item 1). Positional feedback will be via a feedback device (Item 13) mounted within the actuator. Under normal actuator stayput position the solenoid valves (Items 9 & 10) are de-energised. To open the actuator, energise the INTERLOCK (Item 8) and OPEN (Item 9) solenoid valves. To close the actuator, energise the CLOSE solenoid valve (Item 10). Tamperproof speed control is adjustable and obtained by valve (Item 4) for actuator Open and valve (Item 6) for actuator Close. The Rapid Open speed control is by valve (Item 5). Additional features included are as follows:- a. Fast Open of actuator is by energising the RAPID OPEN solenoid valve (Item 7) this will

override all other functions.

b. Actuator Lock in Position is by means of INTERLOCK solenoid valve (Item 8). This valve

is normally energised but in close position from customer signal, will de-energise and lock actuator in close position until energised. The INTERLOCK solenoid valve stops the actuator being opened but allows CLOSE or RAPID OPEN function.

Instructions for Manual Override Manual operation of the actuator is achieved by an integral hand pump (Item 12). For the operation of the hand pump hydraulic fluid is stored and used from an integral reservoir c/w flexible separator (Item 16). Close the hydraulic supply ball valve (Item 14). Energise the appropriate solenoid valve and operate handpump accordingly.

Page 8: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

A ( 1:8 )

Parts List

MATERIALORDER REF.DESCRIPTIONVENDORQTYCONTROL TYPE / PORT SIZEITEM

GenericPS-125-DA ATOS1DIRECT ACTING ACTUATOR 1/2"BSPP1

316SS00005663 PALADON1CABINET ASSEMBLY2

MILD STEEL110132-01125250 BARG MWPFAWCETT CHRISTIE1ACCUMULATOR 1.4L 1/2" BSPP3

Stainless SteelNCB5-18GM40-NO P & F1PROXIMITY SWITCH 4

Stainless Steel341001900SARUM HAND PUMPSARUM HYDRAULICS1SARUM HAND PUMP5

316SSEX JB1919103x M20 L, 1x M20 R, 1xM25 4xM20 B.ORANGE1JUNCTION BOX6

316SSB6FX50S OLIVER VALVES1BALL VALVE 1/2"NPT7

A

ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE STATED DO NOT SCALEIF IN DOUBT ASK

DRAWING No

www.paladonsystems.com

TEL: +44 (0) 1604 880700

PALADON SYSTEMS LIMITED

FERRO FIELDS

THIRD ANGLE

MACHINING

ORIENTATION

GENERAL

0.1mm

0.5mm

1/2 OTHERWISE

UNLESS

STATED

BRIXWORTH

NORTHAMPTONSHIRE

NN6 9UA

UNITED KINGDOM

FAX: +44 (0) 1604 882424

DRAWN

..................................

..............................

.....................................

APP'D

CHK'D

QTYREVSCALE DRAWING No

A B C D E F G H

THIS DRAWING MUST NOT BE COPIED

LENT OR USED IN WHOLE OR PART

WITHOUT THE WRITTEN CONSENT OF

PALADON SYSTEMS LIMITED

COPYRIGHT NOTES

TOLERANCES

TITLE

CLIENT

ORDER No

PROJECT

A3

1

2

3

4

5

6

REV DATE SIGNDESCRIPTION OF REVISION

CPC15815-02-01

CPC15815-02-01

ALVHEIM

P234314

KENT INTROL

SRM

OJ 03.06.14

27/05/2014

BS 03.06.14

GA PS125 DA ACTUATOR

WITH CONTROLS

8" CLASS 1500 VALVE

NOTES:

1) COMPLETE ASSEMBLY TO BE PRESSURE AND FUNCTIONALLY

TESTED TO PALADON PROCEDURES.

2) ALL ASSEMBLY FASTENERS TO BE 316 STAINLESS STEEL.

3) PAINT SPECIFICATION:

NORSOK M-501 SYSTEM No 1 -15815PP

FINAL COLOUR : RAL7038 (AGATE GREY)

4) ALL FITTINGS TO BE 316 STAINLESS STEEL COMPRESSION TYPE:

SWAGELOK - METRIC DOUBLE FERRULE.

5) ALL TUBING TO BE 316 STAINLESS STEEL SEAMLESS TYPE:

10mmOD x 1.5mm WALL THICKNESS

6) UNIT WEIGHT 160 kgs APPROX.

7) TAG NUMBER:

VALVE/ACT

16HCC0104

16HCV0404

8) OPERATING TIMES:

VALVE STEPPING

16HCC0104 60SECONDS TO 15MIN

FAST OPEN - 10SECONDS

16HCV0404 60SECONDS TO 15MIN

FAST OPEN - 10SECONDS

9) DRAWING TO BE READ IN CONJUNCTION WITH:

CPC15815-05-02 SCHEMATIC

CPC15815-05-201 WIRING DIAGRAM

10) OPERATING PRESSURES

180 BARG MIN.

210 BARG MAX.

11) HYDRAULIC FLUID

MINERAL OIL

12) ACTUATOR SPECIFICATION

STROKE LENGTH = 100mm

OPEN/CLOSE THRUST = 19,000Ibs

0 27.05.14 SRMFOR INFORMATION

SHEET

OF1 1

2 1:8 0

90.50-

0.00

0.10+

1/2"NPT

CUSTOMER

HYDRAULIC

SUPPLY

CONNECTION

M20

CUSTOMER

ELECTRICAL

ENTRIES

SOLENOID

IS VALVE CLOSE PROXMITY SWITCH

21

CUSTOMER

ELECTRICAL

4-20mA POSITION

SIGNAL

ENTRY

1.25"-12-UN-CL2A

33

10

0

ST

RO

KE

250 MAX

630 MAX

82

0 M

AX

517

HANDPUMP

HANDLE

290 MAX

730 MAX

2

6

4

1

5

3

7

14

0 C

LO

SE

D

PO

SIT

IO

N

40

1/2"NPT

CUSTOMER

HYDRAULIC

RETURN

CONNECTION

DRAWING LESS CABLING

Page 9: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 10: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

M8

4x M20 CABLE ENTRIES ON BASE

2 x M20 ENTRY ON R/H SIDE

2 x M20 ENTRY ON L/H SIDE

190

FOR IS CABLE ENTRIES

FOR CLIENT NON IS CABLE ENTRIES

196

FOR CLIENT IS CABLE ENTRIES

CONTAINS I.S.

CIRCUITS

All diimensions are nominal for information only

Terminals Weidemuller Interface GmbH & Co.

Type WDU 2.5

Enclosure COOPER Crouse-Hinds (UK) Ltd.

Type STB191910 (STB 3)

IS/ NON IS SPACING 50mm

8 X BEIGE NON IS TERMINALS

5 X BLUE IS TERMINALS

45

40

66

40

190

215

1

2

3

4

5

6

7

8

9

10

11

12

13

4x M20 CABLE ENTRIES ON BASE

FOR NON IS CABLE ENTRIES

FITTED WITH NYLON PLUGS

FITTED WITH NYLON PLUGS

115

SV1

SV2

SV3

SV4

IS1

IS2

F

E

D

C

B

A

1 2 3 4 5 6 7 8

DRG No

UNITED KINGDOM.

NORTHANTS. NN6 9UA.

TITLE

REV

FAX: +44 (0) 1604 882424

TEL: +44 (0) 1604 880700

APPLICATION:

DATE

OTHERWISE

DESCRIPTION OF REVISION

THIRD ANGLE

GENERAL

MACHINING

ORIENTATION

A3

°

±0.5mm

± 0.5

± 0.1mm

STATED

UNLESS PALADON SYSTEMS LTD.

FERRO FIELDS, BRIXWORTH,

SUPPLIER REF: REV.

SHEET

SCALE

QTY

OF

www.paladonsystems.com

SRM04.09.141 IS/NON IS BARRIER REMOVED AS BUILT

JP13/06/140 ISSUE FOR APPROVAL

CO

OJ

1CPC15815-05-201

LAYOUT DRAWING

ACTUATOR JUNCTIONBOX

POR42906

NA

2

JP

11

EEXE JUNCTION BOX

07042/A/001

Page 11: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

F

E

D

C

B

A

1 2 3 4 5 6 7 8

DRG No

UNITED KINGDOM.

NORTHANTS. NN6 9UA.

TITLE

REV

FAX: +44 (0) 1604 882424

TEL: +44 (0) 1604 880700

APPLICATION:

DATE

OTHERWISE

DESCRIPTION OF REVISION

THIRD ANGLE

GENERAL

MACHINING

ORIENTATION

A3

°

±0.5mm

± 0.5

± 0.1mm

STATED

UNLESS PALADON SYSTEMS LTD.

FERRO FIELDS, BRIXWORTH,

SUPPLIER REF: REV.

SHEET

SCALE

QTY

OF

www.paladonsystems.com

SRM04.09.141 RAPID OPEN WAS CLOSE

JP13/06/140 ISSUE FOR APPROVAL

CO

OJ

1CPC15815-05-202

WIRING DRAWING

ACTUATOR JUNCTIONBOX

POR42906

NA

2

JP

11

EEXE JUNCTION BOX

07042/C/001

Page 12: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Component Manuals

Page 13: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 14: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 15: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 16: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 17: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104
Page 18: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

SECTION CONTENTS PAGE NO.

1.0 DESCRIPTION 12.0 SPECIFICATION 1-53.0 INSTALLATION 6-7

Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 8DE

Tel: +44 (0)1684 296818 Fax: +44 (0)1684 293746

Email: [email protected] Web: www.status.co.uk

52-214-2407-01 Issue: Web 210

SEM210 SERIES

INDEX

Programmable In-head Universal Temperature Transmitter

Page 19: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

The transmitter is a second generation 'Smart' in-head temperature transmitter that accepts any commonlyused temperature sensor, slidewire transducer or millivolt signal and converts the output to the industrystandard (4 to 20) mA transmission signal. The software package RCPW can be used to program the unit.

Sensor Range (-200 to 850) ºC (18 to 390) ΩMinimum Span*¹ 25 ºCLinearisation BS EN60751 (IEC 751)

BS 1904 (DIN 43760)JISC 1604CUSTOM [X]*³

Basic Measurement Accuracy*² ± 0.01 % FRI ± 0.05 % Rdg (FRI = Full Range Input)Thermal Drift Zero 0.008 ºC/ºC

Span 0.01 %/ºCExcitation Current (300 to 550) µAMaximum Lead Resistance 50 Ω/legLead Resistance Effect 0.002 ºC/Ω

SENSOR RANGES

Thermocouple Type Measuring Range*4 ºC Minimum Span*¹ ºCTC Type K -200 to 1370 50TC Type J -200 to 1200 50TC Type T -210 to 400 25TC Type R -10 to 1760 10TC Type S -10 to 1760 100TC Type E -200 to 1000 50TC Type L -100 to 600 25TC Type N -180 to 1300 50TC Type [X]*³ User defined

Linearisation BS 4937 / IEC 584, EN60584Basic Measurement Accuracy*² ± 0.04 % FRI ± 0.04 % RDG or 0.5 ºC (whichever is greater)Thermal Drift Zero 0.1 µV/ºC

Span 0.01 %/ºCCold Junction Error ± 0.5 ºCCold Junction Tracking 0.05 ºC/ºCCold Junction Range (-40 to 85) ºC

Page 1

Input Voltage sourceRange (-10 to 75) mVCharacterisation Linear

Custom [X]*³, 4th order polynomialMinimum Span*¹ 5 mVBasic Measurement Accuracy*² ± 10 µV ± 0.07 % RdgInput Impedance 10 MΩThermal Drift Zero 0.1 µV/ºC

Span 0.01 %/ºC

Input 3 wire potentiometerResistance Range (10 to 390) Ω (end to end).

Larger values can be accommodated by external resistor.Characterisation Linear

Custom [X]*³, 4th order polynomialMinimum Span*¹ 5 %Basic Measurement Accuracy*² 0.1 % FRITemperature Drift 0.01 %/ºC

Output Range (4 to 20) mA (> 3.8 to < 20.2) mAMaximum Output 23 mAAccuracy ± 5 µAVoltage Effect 0.2 µA/VThermal Drift 1 µA/ºCSupply Voltage (10 to 35) VMaximum Output Load [(Vsupply -10)/20] kΩ (e.g 700 Ω @ 24 V)

*NOTES:1. Any span may be selected, full accuracy is only guaranteed for spans greater than the minimum

recommended.2. Basic measurement accuracy includes the effects of calibration, linearisation and repeatability.3. Customer linearisation requirements are available pre-programmed at the factory, contact your

supplier for details.4. Consult thermocouple reference standards for thermocouple material limitation.5. If the unit is to be configured for either millivolts or slidewire input, the following procedure should

be followed. Configure unit for RTD with BS1904 linearisation (Not EN60751) and up load to unit. The unit can now be configured for millivolts or slidewire input.

Page 2

1.0 DESCRIPTION

2.1 RTD INPUT (Pt100)

2.0 SPECIFICATION @ 20 ºC

2.3 MILLIVOLT INPUT*5

2.5 OUTPUT

2.2 THERMOCOUPLE INPUT

2.4 SLIDEWIRE INPUT*5

Page 20: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Page 3

Input/Output Isolation 500 VAC rms (galvanically isolated)Update Time 250 ms maximumTime Constant (Filter Off) < 1 s (Time to reach 63 % final value)Filter Factor Programmable Off, 2 s, 10 s or adaptiveWarm up Time 120 s to full accuracy

ENVIRONMENTALAmbient Operating Range (-40 to 85) ºCAmbient Storage Temperature (-50 to 100) ºCAmbient Humidity Range (10 to 90) % RH non condensing

APPROVALSEMC BS EN61326

MECHANICALEnclosure DIN standard terminal block sizeMaterial ABSWeight 35 gDimensions (43 x 21) mm

COMMUNICATIONSPC Interface RS232 via configuratorMinimum Output Load 250 Ω for 'In loop' programmingMaximum Cable Length 1000 mConfigurable Parameters Sensor type: Burnout: ºC/ºF: Output: Hi/Lo: Filter: Tag: UseroffsetComms Protocol ANSI X3.28 1976Data Rate 1200 baud

The SEM210X, has been issued with a EC-type examination certificate, confirming compliance with theEuropean ATEX directive 94/9/EC for:

INTRINSIC SAFETY II 1 G EEx ia IIC T4…T6.

The equipment bears the Community Mark and subject to local codes of practice, may be installed in anyof the European Economic Area (EEA) member countries. The SEM210X housing is coloured light blue toidentify the equipment as suitable for Hazardous area use. The equipment must be installed and maintained in accordance with local requirements for electrical equipment for use in potentially explosive atmospheres, e.g EN60079-14 & EN60079-17. This instruction sheet describes installation whichconforms with BS EN60079-14 & BS EN60079-17 Electrical Installation in Hazardous Areas. When designingsystems outside the UK, the local Code of Practice should be consulted.

Page 4

Manufacturer Status Instruments LtdType Number SEM210X

CE Marking

Explosive Protection Marking

(TYPE ia) INTRINSIC SAFETYII 1 Equipment group and categoryG Type of explosive atmosphere (Gas)EEx ia IIC T4..T6 Intrinsic safety informationTRL03ATEX21032 X Certificate reference

As indicated by the Certificate Reference "X" suffix, special conditions apply for safe use for both intrinsicsafety and energy limitation applications. They are as follows:

ZONES, GAS GROUPS, AND T RATING.When connected to a approved system the SEM210X may be installed in:

Zone 0 Explosive gas air mixture continuously presentZone 1 Explosive gas air mixture likely to occur in normal useZone 2 Explosive gas air mixture not likely to occur and if it does, it will only occur for a short time.

Be used in gas groups:

Group A PropaneGroup B EthyleneGroup C Hydrogen

2.6 GENERAL

2.7 SEM210X VERSION - FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES

2.7.1 ATEX CERTIFICATE

2.7.2 ATEX MARKING

COMMON INFORMATION

0891

2.7.3 SPECIAL CONDITIONS FOR SAFE USE

Page 21: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Page 5 Page 6

The transmitter is mounted using two 5.5 mm diameter holes, on standard 33 mm fixing centres and willfit a DIN standard termination head. The transmitter should be installed with adequate protection frommoisture and corrosive atmospheres.

Care must be taken when locating the transmitter to ensure the ambient temperature remains within thespecified operating range. Figure 1 shows the mechanical layout and a typical application of the transmittermounted inside a termination head enclosure, with sensor wires entering through the centre of thetransmitter body.

Allowable temperature classification/ambient temperature:

INTRINSIC SAFETY (Type ia)

CLASS AMBIENT TEMPERATURE RANGE °CT1 450°C -25 to 85T2 300°C -25 to 85T3 200°C -25 to 85T4 135°C -25 to 85T5 100°C -25 to 50T6 85°C -25 to 40

This equipment must be housed in an enclosure which provides a degree of protection of at least IP54.The enclosure must be suitable for the atmosphere and environment in which it is installed. (e.g. If of aplastic material, must be resistant to chemical corrosion, UV light, temperature, humidity, etc).

This intrinsically safe equipment contains no user serviceable, adjustable or replaceable parts. No attemptshould be made to repair a faulty SEM210X transmitter, all units must be returned to the manufacture forrepair or replacement. Attempt service or replacement of parts may invalidate the explosive protectionfeatures of the equipment.

They equipment must be electrically connected as shown below:

SEM210X WORKING PARAMETERSUi 30 V I i 100 mAPi 750 mWCi 10 nF Li 0 µH

2.7.4 ENVIRONMENTAL PROTECTION

2.7.5 MAINTENANCE

SENSOR

DC SUPPLY

+

-

SEM210X

3 1

4

5

2

BARRIER

Vo 30 Vlo 100 mAPo 750 mW

EARTH

SAFE AREAHAZARDOUS AREA

2.8 CONNECTION DIAGRAM

3.0 INSTALLATION

3.1 MECHANICAL

24.00 mm

Ø44.00 mm

Ø33.00 mm Centres

Centre hole Ø6.3 mm

Figure 1

CABLEENTRY

(4 to 20) mALOOP

ENCLOSURE

Figure 2

Page 22: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Page 7 Page 8

Connections to the transmitter are made to the screw terminals provided on the top face. No specialwires are required for the output connections, but screened twisted pair cable are the most suitable forlong runs. It is recommended that screened cable is used for the three input signal wires for cable runsgreater than one metre. All three input wires must have the same core diameter to maintain equal leadresistance in each wire. A Ø4.5mm hole is provided through the centre of the transmitter to allow sensorwires to be threaded through the transmitter body direct to the input screw terminals. The screw terminals have been designed to allow all connection wires to enter from an inner or an outer direction.

Figure 3 shows the method of connection to provide a (4 to 20) mA current loop output. The Pt100 sensorshown would normally take the form of a probe assembly with a three wire connection. The output loophas a voltage power supply used to provide loop excitation. The load symbol represents other equipmentin the loop, normally indicators, controllers or loggers. Care must be taken when designing the (4 to 20)mA circuit to ensure that the total voltage requirements of all the equipment in the loop added together,does not exceed the power supply voltage. If a number of instruments are connected in the loop, ensurethat only one instrument is tied to ground. Grounding the loop at two points will cause a short circuit ofpart of the loop leading to measurement errors.

To guarantee CE compliance, sensor leads must be less than 3 m long and the transmitter housing shouldprevent access to the transmitter during normal operation.

* Fit Rx for all potentiometers with end to end resistance > 390 Ω. Such that total end to endresistance is > 200 Ω < 390 Ω.

3.2 ELECTRICAL

MILLIVOLT

POWERSUPPLY

LOAD

Pt100

TCmV

(10 to 35) VDC

3 4

3 4 5

3 4

2 1

3 4 5SLIDEWIRE

Rx

(4 to 20) mAT/C

Pt100

+

+-

- -+

+-- +Figure 3

Smart In Head Temperature Transmitters DIN Rail Mounted Temperature Transmitters Panel & Field Temperature Indicators Temperature Probes Trip Amplifiers Signal Conditioners And many other products

For further information on all products:

Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 8DE

Tel: +44 (0)1684 296818 Fax: +44 (0)1684 293746

Email: [email protected] Web: www.status.co.uk

ALSO AVAILABLE:

Page 23: OPERATING AND MAINTENANCE INSTRUCTIONS - omeas.comomeas.com/wp-content/uploads/2018/08/Paladon-actuator-IOM.pdf · drawing index ga drawings tag no. cpc15815-02-01 rev 0 16hcc0104

Spares Kit Ordering & Additional Service Support When requesting service support or ordering spares kits, please provide the following contract details: • Actuator Serial Number (6 or 7 digit number with a RFPL prefix) • Paladon Contract Number (5 digit number with an ACCP, ACE, ACP, ACSP, CCP, CE,

CGH, CP, CPC or CSP prefix) • General Arrangement or Control Schematic Drawing Number • Full Actuator Model Number(s) and Descriptions • Tag Number(s) Please contact your nearest Paladon representative as detailed below: • Paladon Systems Ltd

Ferro Fields, Brixworth, Northampton, NN6 9UA, England Tel: +44 (0)1604 880700 Fax: +44 (0)1604 882424 [email protected]

• Paladon Italia Via Barbieri, 24, 27040 Pinarolo Po, PV, Italy Tel: +39 0383 878524 Fax: +39 0383 878042 [email protected]

• Paladon SDT 121352 Davydkovskaya Str. 12/3. Moscow, The Russian Federation Tel/Fax: +7 495 735 28 07 (08) (09) [email protected]

• Paladon Systems Ltd Asia Pacific Region Lot 3-4, Jalan Tanjung Keramat 26/35, Seksyen 26, 40400 Shah Alam, Selangor, Malaysia Tel: +603 5102 5063 Fax: +603 5102 5100 Mobile: +6012 311 3247 [email protected]

• www.paladonsystems.com