one link one-link connector is available in the following configurations baxter healthcare...
TRANSCRIPT
One Simple SolutionA Neutral Design for Patients
One •LinkNeedle-free IV Connector
Engineered for simple performance 1
• Neutral fluid displacement design — helps reduce the risk of thrombotic catheter occlusions compared to devices with higher reflux volumes 2
• Power injection compatible (up to 325 psi, 10 mL/second) — helps minimize connector failure and change-outs
• Compatible, flexible design — works with a variety of valved and non-valved vascular access catheters
• No clamping sequence required
— Simplifies training
— Clamp when not in use for patient safety
• Tested for use up to 7 days/200 actuations † — aligns with CDC 2011 guidelines for the prevention of intravascular catheter-related infections
• Saline or Heparin flush option — allows clinician flexibility to follow facility protocols
Note: refer to catheter manufacturers’ flushing instructions.
One Simple Solutionto help meet patient and clinician needs
One •LinkNeedle-free IV Connector
The One-Link connector’s neutral fluid displacement is designed to help reduce the risk of thrombotic catheter occlusions compared to devices with higher reflux volumes.1
The clear housing can enhance clinical practice.
* One-Link Needle-free IV Connector (7N8399)
† Replace per institution protocol. The One-Link connector can be used for up to 200 actuations and over a period of 7 days. Replace device whichever comes first.
Finger-grip design reduces the likelihood of touch contamination
Smooth surface for easy cleansing reduces the risk of contamination
Clear housing allows for visualization of the fluid path
Double-seal design provides an effective barrier to microbial ingress
Straight fluid path promotes thorough flushing
Non-PVC* and Non-DEHP for patients with special requirements
Meets power injection needs 1
• Tubing and slide clamp — identify maximum pressure for power injection compatible components
One Simple Solutionfor CT/MRI applications
Meets FDA labeling recommendations for use with power injectors 3
* Prior to power injection, ensure all parts of IV system are compatible. Replace if a pressure over 325 psi is applied to the connector.
• Compatible with power injection (up to 325 psi)* — designed to prevent connector and tubing failure
• Helps minimize change-outs — when used with compatible pressure rated catheter and extension set
• Maximum flow rate of 10 mL/second — appropriate for a wide variety of patient types
• Neutral fluid displacement design — designed to help reduce the risk of thrombotic catheter occlusions, compared to devices with higher reflux volumes 1
• Low priming volume of 0.08 mL — minimizes excessive flush volumes for fluid restricted patients
• Smooth surface, easy to cleanse — promotes reduction of contamination
• Compatible with a variety of valved and non-valved vascular access catheters — provides flexibility for use throughout the facility and may help reduce time and cost
• Double-seal design — provides an effective barrier to microbial ingress
• Non-PVC and Non-DEHP — for patients with special requirements
Universally appropriate 1
One •LinkNeedle-free IV Connector
One Simple Solutionfor your patient’s needs
The One-Link IV connector is intended for single patient use with a vascular access device for the administration of drugs and solutions without needles and can be used to aspirate blood.
Catheter Occlusions• Catheter occlusion is the most common noninfectious
complication in the use of central venous catheters (CVCs) and occurs in approximately 33% of these catheters.4,10
• A common cause for catheter occlusion is clotting of blood refluxed into the catheter. Blood reflux occurs when an administration set or syringe is connected to a positive displacement connector or disconnected from a negative displacement connector.4
• Catheter occlusions can interrupt IV therapy, increase risk of serious complications, and add to the cost of care.4
Bloodstream Infections• The FDA has expressed concern about several clinical reports
regarding the association of BSIs with positive displacement devices.5
• Facilities and governments have increased pressure to reduce hospital-acquired infections (HAIs).
• An estimated 248,000 bloodstream infections occur in U.S. hospitals each year with a large portion associated with CVCs.6
• These infections independently increase hospital costs and length of stay.7
• By several analyses the cost of these infections is substantial in terms of morbidity and financial resources expended.7
Connector Failure• Connectors not designed to tolerate pressures used for power
injection can fail and harm the patient.3
• Failure can delay treatment of patient.8
Training Requirements• Multiple connectors with varied techniques can cause
confusion and increased potential for errors.9
• IV needleless connectors have become complex in design.9
Key Issues with IV Connectors
Adapted from McKnight 2004.
Number of CVCs placed per year 5,000,000
Percent thrombotic 10 58%
Estimated U.S. annual central venous catheters
The Clinical Environment
Studies have shown a relationship between the presence of thrombosis and CR-BSIs.2
The One-Link Connector is available in the following configurations
Baxter Healthcare Corporation, Route 120 and Wilson Road, Round Lake, IL 60073. www.baxter.com Baxter, One-Link and SIGMA Spectrum are trademarks of Baxter International Inc.213835 10K 06/12
One simple solution for standardization 11
• Allows for product standardization• Helps reduce inventory• Streamlines ordering
One •LinkNeedle-free IV Connector
REFERENCES:1. Data on file. Baxter Healthcare Corporation.2. Yacopetti N. Central Venous Catheter-Related Thrombosis-A Systematic Review. Journal of Infusion Nursing. July/August 2008; 31(4): 244.3. Reminders from FDA Regarding Ruptured Vascular Access Devices from Power Injection. www.fda.gov (January 2009).4. Hadaway L. Reopen the pipeline. Nursing. 2005; 35(8): 54-61. 5. FDA Alert Letter: Positive Displacement Needleless Connectors and Bloodstream Infections: Initial Communication. August 11, 2010.6. CDC June 2010: Central Line-Associated Bloodstream Infection (CLABSI) Event.7. CDC June 2011: Central Line-Associated Bloodstream Infection (CLABSI) Event.8. Pennsylvania Patient Safety Authority Vol 5, No 4-December 2008, CT Contrast Media Power Infectors Can Rupture Conventional IV Sets.9. Jarvis W. Choosing the Best Design for Intravenous Needleless Connectors to Prevent Bloodstream Infections. www.infectioncontroltoday.com, posted 7/28/2010.10. McKnight S. Nurse’s Guide to Understanding and Treating Thrombotic Occlusion of Central Venous Access Devices. MEDSURG Nursing. December 2004; 13(6): 377.11. Carlo A. Standardization basics and why they are so important to the bottom line. Materials Management in Health Care. December 2007.
Rx Only. For safe and proper use of the One-Link devices, refer to the appropriate Instructions for Use. For safe and proper use of the SIGMA Spectrum pump, refer to the Operator’s Manual.
For use with low pressure power injectors having a maximum pressure of 325 psi and a maximum flow rate of 10 mL/second
Also available in other products (tubing not rated for power injection)
7N8399 One-Link Needle-free IV Connector With Neutral Fluid Displacement, Power Injectable (325 psi)
7N8378 One-Link Non-DEHP Standard Bore Catheter Extension Set Needle-free IV Connector with Neutral Fluid Displacement
7N8377 One-Link Non-DEHP Y-Type Standard Bore Catheter Extension Set Needle-free IV Connector with Neutral Fluid Displacement
7N8300 One-Link Non-DEHP Microbore Catheter Extension Set Needle-free IV Connector with Neutral Fluid Displacement, Power Injectable (325 psi)
7N8371One-Link Non-DEHP Y-Type Microbore Catheter Extension Set Needle-free IV Connector with Neutral Fluid Displacement