Annex 41 take-off meeting – 1 Vasco Peixoto de Freitas – Nuno M. M. Ramos LFC Annex 41 take-off meeting FEUP-LFC contribution Annex 41 take-off meeting FEUP-LFC contribution Vasco Peixoto de Freitas Nuno M. M. Ramos FACULTY OF ENGENEERING – PORTO UNIVERSITY LABORATORY OF BUILDING PHYSICS Vasco Peixoto de Freitas Nuno M. M. Ramos FACULTY OF ENGENEERING – PORTO UNIVERSITY LABORATORY OF BUILDING PHYSICS

Upload: others

Post on 22-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting – 1Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

Annex 41 take-off meetingFEUP-LFC contribution

Annex 41 take-off meetingFEUP-LFC contribution

Vasco Peixoto de FreitasNuno M. M. Ramos

FACULTY OF ENGENEERING – PORTO UNIVERSITY

LABORATORY OF BUILDING PHYSICS

Vasco Peixoto de FreitasNuno M. M. Ramos

FACULTY OF ENGENEERING – PORTO UNIVERSITY

LABORATORY OF BUILDING PHYSICS

Page 2: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 2Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PRESENTATIONPRESENTATION

• Introduction to FEUP-LFC

• Testing Facilities

• Modelling

• Projects

• FEUP-LFC in MOIST-ENG

• Conclusions

• Introduction to FEUP-LFC

• Testing Facilities

• Modelling

• Projects

• FEUP-LFC in MOIST-ENG

• Conclusions

Page 3: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 3Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

INTRODUCTION TO FEUP-LFCINTRODUCTION TO FEUP-LFC

HumanHuman resourcesresources�� PhD: PhD: 22�� PhD Students: 6PhD Students: 6�� MMSSc Students: 5c Students: 5

PATHOLOGYAND

REFURBISHMENT

PATHOLOGYPATHOLOGYANDAND

REFURBISHMENTREFURBISHMENTHYGROTHERMAL

BEHAVIOUR

HYGROTHERMALHYGROTHERMALBEHAVIOURBEHAVIOUR

ENERGYEFFICIENCY

ENERGYENERGYEFFICIENCYEFFICIENCY DURABILITYDURABILITYDURABILITYMATERIALSMATERIALSMATERIALS

FEUP-LFC BUILDING PHYSICS LABORATORY

Page 4: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 4Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

TESTING FACILITIESTESTING FACILITIES1. Measurement of

hygrothermal propertiesλλλλThermal Conductivity

δδδδv

Vapour Permeability

DwMoisture Diffusivity

Ventilation

Infra-red Thermography

2. Weather station

3. Walk-in climatic chambers

Page 5: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 5Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

MODELLINGMODELLING

Condensa 2000Vapour diffusionISO 13788

RH 2000Modelling relativehumidity inside dwellings

CONDUCHeat transfer 2Dthermal bridges

TRHUM 98 Modelling heat and moisture transfer in components (1D)

Page 6: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 6Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PROJECTS: Hygroscopic InertiaPROJECTS: Hygroscopic InertiaProblem Model and Measurements

Results

� Vapour production

� Ventilation

� Hygroscopicity

( )∑=

−×

−−

×=

−n

jmji

jj

ev

esate

iv

isati

iv

iii

i ATR

TPTR

TPVNGTR

VdtdT

PTdtdP

1462 106.3

.)(.)(.3600

.106.3.

φφγφφ

0

10

20

30

40

50

60

70

80

90

100

0 300 600 900 1200 1500 1800

Tempo (h)H

umid

ade

Rel

ativ

a (%

)

HRi Sim. 1 (sem superfícies higroscópicas)HRi Sim. 2 (argamassa - 2 cm)HRm argamassa - 2 cmHRi Sim. 3 (argamassa - 4 cm)HRm argamassa - 4 cm

Page 7: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 7Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PROJECTS: Rising Damp in Historic Buildings

PROJECTS: Rising Damp in Historic Buildings

Problem Experimental Device

Numerical Simulation Application

aprox. 0.80m0.50

43

21

LEGENDA:1 - ELEMENTOS METÁLICOS2 - PEÇA PREFABRICADA EM BETÃO3 - TELA DE PVC (1 mm)4 - PEDRA REACERTADA5 - AREIA6 - TUBO DE VENTILAÇÃO7 - GEOTÊXTIL

PORMENOR 1

PORMENOR 3PORMENOR 2

0.50

0.200.20

ESQUEMA AXONOMÉTRICO DO

DISPOSITIVO DE ADMISSÃO DE AR AO

SUBSISTEMA SUL

PORMENOR 1PORMENOR 3

Nave da Igreja

Capela Lateral

PORMENOR 2

54321

52 6 3 75 5 3 7 6

Page 8: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 8Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PROJECTS: Natural VentilationPROJECTS: Natural VentilationProblem Measurements

Equipment Results

RPH = 3,96

y = -3,9642x + 5,2635R2 = 0,952

1,0

1,5

2 ,0

2 ,5

3 ,0

3 ,5

4 ,0

4 ,5

5,0

5,5

0 ,0 0 ,2 0 ,4 0 ,6 0 ,8 1,0 1,2

Tempo (h)

Ln (C

)

PHOTOACOUSTIC PHOTOACOUSTIC MULTIMULTI--GAS GAS ANALYZERANALYZER

CAPSULES PFTCAPSULES PFT

0,30,320,340,360,38

0,40,420,440,460,48

0,50,520,54

12 13 14 15 16 17 18 19 20 21

Temperatura Interior (ºC)

RPH (1/h)

12 3

46

7 8 9

5N

0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

RPH local (1/h)

1 2 3 4 5 6 7 8 9

Compartimento

Page 9: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 9Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PROJECTS: Infrared Thermography

PROJECTS: Infrared Thermography

Problem

Results

Equipment

Page 10: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 10Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

PROJECTS: Dimensional Stability of Wood

PROJECTS: Dimensional Stability of Wood

Problem Equipment

Measurements

Page 11: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 11Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

FEUP-LFC in MOIST-ENGFEUP-LFC in MOIST-ENG

Subtask1: Modellingand common exercises

0

10

20

30

40

50

60

70

80

90

100

0 300 600 900 1200 1500 1800

Time (h)

Rela

tive

Hum

idity

(%)

RHi Sim. 1 (no hygroscopic surfaces)

RHi Sim. 2 (mortar - 2 cm)

RHmortar Sim. 2

1. Modelling relative humidity variation inside rooms, especially moisture buffering effect

2. Common exercises at room level

Page 12: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 12Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

FEUP-LFC in MOIST-ENGFEUP-LFC in MOIST-ENG

Subtask2: Experimental investigations

1. Database of moisture storage properties of building and finishing materials

2. Comparison of computer model results with laboratory tests

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

30 40 50 60 70 80 90 100

HRi (%)

(g/(m

2.h.

HR)

)

adsorption

desorption

Page 13: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 13Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

FEUP-LFC in MOIST-ENGFEUP-LFC in MOIST-ENG

Subtask3: Boundary Conditions

1. Definition of Portuguese outdoor moisture loads

2. Definition of Portuguese indoor temperatures and moisture production in dwellings

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

18.0

20.0

0 300 600 900 1200 1500 1800

Time (h)

Out

side

Tem

pera

ture

(ºC

)

0.0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

100.0

0 300 600 900 1200 1500 1800

Time (h)

Out

side

Rel

ativ

e H

umid

ity (%

)

Page 14: Nuno M. M. Ramos No… · AXONOMÉTRICO DO DISPOSITIVO DE ADMISSÃO DE AR AO SUBSISTEMA SUL PORMENOR 1 PORMENOR 3 Nave da Igreja Capela Lateral PORMENOR 2 5 4 3 2 1 5 2 637 5 537

Annex 41 take-off meeting– 14Vasco Peixoto de Freitas – Nuno M. M. Ramos

LFC

CONCLUSIONSCONCLUSIONS

• FEUP-LFC develops work on HAM motivated by the problems in Portuguese buildings

• FEUP-LFC has the support of the Portuguese member on the EXCO IEA ECBCS to participate in the MOIST-ENG project

• FEUP-LFC will contribute to MOIST-ENG with modelling work and laboratory experiments

• FEUP-LFC develops work on HAM motivated by the problems in Portuguese buildings

• FEUP-LFC has the support of the Portuguese member on the EXCO IEA ECBCS to participate in the MOIST-ENG project

• FEUP-LFC will contribute to MOIST-ENG with modelling work and laboratory experiments