Micro Module Switch PDL5011WL 1 2 3 4 Follow the installation instructions Download the Wiser Room App for your smartphone Connect your smartphone to the switch Must be installed and con- figured with a momentary push-button switch 1 2 C LOOP 1 2 C LOOP MOMENTARY SWITCH 1 MOMENTARY SWITCH 2 LOAD MICRO MODULE SWITCH Note: All Active connections must be on the same phase. A Active N Neutral L Load I Momentary switch - switched Active PE Protective Earth A N PE L A N I LOOP A N PE L N PE A I L (Refer to Load rating table) Note: This product MUST be installed with a Momentary Push-button Switch. The circuit must be protected from overloading in accordance with wiring rules. The product is not suitable for ceiling mounting. Cabling and connections Typical 2-way installation using micro module switch and momentary push-button switches. TM Installation DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This product must be installed and serviced by appropriately qualified and/or licenced electrical personnel. Isolate the electrical supply before doing any work on this product. Ensure all terminals and live parts are suitably insulated from all mounting accessories. Ensure that the product has been correctly installed and tested for safe operation before reconnecting the electrical supply. Failure to follow these instructions will result in death or serious injury. For your safety CAUTION EQUIPMENT DAMAGE HAZARD Install the device according to instructions in this document. Pay attention to the specifications and wiring diagrams related to the installation. Do not use this product for any other purpose than specified in this instruction. Dropping the device may damage the mech. Check device operates after being dropped or if physical damage is shown. Failure to follow these instructions can result in injury or equipment damage. NOTICE EQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION) Operation of micro module switch at elevated temperatures or voltages outside of specification (240 V a.c. and 25 °C) may cause the over-temperature protection circuitry to operate. Operating with significant overload may cause the thermal fuse to blow and render the unit inoperable. Reduce the size of the connected load or use a different brand of lamp to prevent recurrence. Do not operate the product for prolonged periods in extreme conditions. Product must be installed in an appropriate enclosure in accordance with AS/NZS 3000. Failure to follow these instructions can result in equipment damage. NOTICE MAXIMUM POWER RATING APPLY Ensure that the number of low voltage lighting transformers connected to a single switch does not exceed the maximum power rating. Failure to follow these instructions can result in equipment damage. Wiser Room App Download the Wiser Room App to connect your smart phone or tablet to the switch. A N L A N I LOOP Load rating Dimmable LED 200 W Non-dimmable LED 200 W Incandescent 10 A M Motor M.40 / 4.5 A Electronic transformer 1050 VA Iron core transformer 500 VA Fluorescent 10 A

Upload: others

Post on 04-Oct-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NOTICE - Schneider Electric

Micro ModuleSwitch

PDL5011WL

1

2

3

4

Follow the installation instructions

Download the Wiser Room App for your smartphone

Connect your smartphone to the switch

Must be installed and con-figured with a momentary push-button switch

12

CLOOP

12

C

LOOP

MOMENTARYSWITCH

1

MOMENTARYSWITCH

2

LOAD

MICROMODULESWITCH

Note:All Active connections must be on the same phase.

A ActiveN NeutralL LoadI Momentary switch - switched ActivePE Protective Earth

ANPE

L A N I LOOP

ANPE

LNPE

AI

L

(Refer to Load rating

table)

Note: • This product MUST be installed with a Momentary Push-button Switch. • The circuit must be protected from overloading in accordance with wiring rules.• The product is not suitable for ceiling mounting.

Cabling and connections Typical 2-way installation using micro module switch and momentary push-button switches.

TM

Installation

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

• This product must be installed and serviced by appropriately qualified and/or licenced electrical personnel.

• Isolate the electrical supply before doing any work on this product.

• Ensure all terminals and live parts are suitably insulated from all mounting accessories.

• Ensure that the product has been correctly installed and tested for safe operation before reconnecting the electrical supply.

Failure to follow these instructions will result in death or serious injury.

For your safety

CAUTIONEQUIPMENT DAMAGE HAZARD• Install the device according to instructions in this document.• Pay attention to the specifications and wiring diagrams related to

the installation.• Do not use this product for any other purpose than specified in this

instruction.• Dropping the device may damage the mech. Check device operates

after being dropped or if physical damage is shown.

Failure to follow these instructions can result in injury or equipment damage.

NOTICEEQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION)• Operation of micro module switch at elevated temperatures or

voltages outside of specification (240 V a.c. and 25 °C) may cause the over-temperature protection circuitry to operate. Operating with significant overload may cause the thermal fuse to blow and render the unit inoperable.

• Reduce the size of the connected load or use a different brand of lamp to prevent recurrence.

• Do not operate the product for prolonged periods in extreme conditions.• Product must be installed in an appropriate enclosure in accordance

with AS/NZS 3000.

Failure to follow these instructions can result in equipment damage.

NOTICEMAXIMUM POWER RATING APPLYEnsure that the number of low voltage lighting transformers connected to a single switch does not exceed the maximum power rating.

Failure to follow these instructions can result in equipment damage.

Wiser Room App

Download the Wiser Room App to connect your smart phone or tablet to the switch.

AN

LA N I LOOP

Load rating

Dimmable LED 200 W

Non-dimmable LED 200 W

Incandescent 10 A

M Motor M.40 / 4.5 A

Electronic transformer 1050 VA

Iron core transformer 500 VA

Fluorescent 10 A

Page 2: NOTICE - Schneider Electric

PHA3465301_01 November 2019

Restoring the switch to factory defaultsNote: All customised settings and bluetooth pairing information will be lost.

Advanced settings > Create an installer restore pointEnter password A, then Continue B(Note: Password cannot be changed)

Password:

1 2 3 4

Continue

Create an installer restore point

Advanced settings >

‘Copy and paste’ settings from another Wiser Iconic device Note: Settings can only be copied from a switch of the exact same model.

Setting/Adjusting the timer

Timer > Enable the timer A Set time interval B, then save C

Timer enable

Timer >

When pairing with new device …or via Advanced settings Select switch to copy from A, then copy B

Copy settings from another device >

Copy settings from another device

Using the Wiser Room App

Schneider Electric (NZ) Ltd

Building 6, 60 Highbrook Drive, East Tamaki, Auckland 2013 New Zealand

Customer Care: 0800 652 999Email: [email protected] www.schneider-electric.comSchneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in these instructions are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

© Schneider Electric 2019

This material is copyright under New Zealand and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric.

Customer care

We warrant this product for 2 years, for details visit https://www.schneider-electric.co.nz/en/about-us/legal/terms-and-conditions.jsp

Creating an Installer restore point

Short pressswitch3 times

Start theWiser Room App

on your smart phone,then tap

Edit > + Add new device

Follow pairinginstructions in

Wiser Room App

Switch andsmart phone

paired

3x

Wiser Room App Wiser Room App

Pairing

TM

Short Press 4 times10-15 seconds hold

Release

Configuration with the Wiser Room AppUse the Wiser Room App to customise the switch:• Create an ‘Installer restore point’ to save settings in

case a future restore is needed (highly recommended).• ‘Copy and paste’ settings from another Wiser Micro Module

switch to save time when configuring multiple switches, such as when installing in an apartment block.

If desired, use the Wiser Room App to set and adjust the timer.

NOTE: When controlling with the Wiser Room App be in the same room and within a range of 8-10 m of the switch. Range can be affected by walls and other structures.

Switch settings...

Technical data

Note: See product datasheet for full specifications. Specifications typical at 25 °C.

Operating voltage 220–240 V a.c., 50 Hz

Max load rating 10 A. Refer to Load Rating table on front page for further details.

Output 1 dry contact

Standby power Maximum 0.4 W

Wiring 3-wire design

Connecting terminals Screw terminals for max 2 x 2.5 mm2

Multi-way limits Max 10 momentary push-button switches, max 50 m cable

Operating temperature 10 oC to 35 oC

Operating humidity 40%–80% RH, non-condensing

Environmental rating IP20

Standards AS/NZS 60669.2.1, AS/NZS 4268

Certification CE, RCM

43 mm

43 mm22 mm

75 mm

75 mm40 mm

Switch Operation

Latching (default setting):Pressing the momentary push-button or App once turns the switch ON, pushing it again turns the switch OFF.

Pulse generating:In Advanced Settings, enable Pulse Generator mode. Then when a momentary push-button or App button is pressed, the load will be ON for 200 ms and then will switch OFF.

Advanced settings > Enable Pulse Generator

Advanced settings >

Pulse Generator >