nbec 2014 - flow exponent values and implications for air leakage testing
TRANSCRIPT
![Page 1: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/1.jpg)
Flow Exponent Values and Implications for Air Leakage Testing
NBEC 2014 ROBIN URQUHART, MBSC, MA NRES, RDH BUILDING ENGINEERING
DR. RUSSELL RICHMAN, P.ENG, RYERSON UNIVERSITY
![Page 2: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/2.jpg)
Outline
à Introduction to air leakage testing
à Relationship between flow and pressure
à Case study building
à Abnormal flow exponents
à Data extrapolation to operating pressures
à Conclusions/Implications
à Further study
![Page 3: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/3.jpg)
Air leakage testing
à Air leakage = Uncontrolled air movement through the
building enclosure à Can account for up to 50% of a buildings heat loss/gain
à Affects assembly durability
Stack Wind
![Page 4: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/4.jpg)
Fan induced pressure
à Induced pressure differentials using fans à Mechanical
à Blower door
à ASTM E779-10 (10-60 Pa) à multi-point
à ASTM 1827-12 (50 Pa) à single point
à USACE (75 Pa) à single point
![Page 5: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/5.jpg)
Why test?
à Evaluate performance and determine retrofit options à Single building
à Building stock
à Determine leakage rates for energy models à 4 Pa – 10 Pa
à Code or other
specification compliance
à LEED, Energuide, etc.
![Page 6: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/6.jpg)
The Relationship between Flow and Pressure
Pressure (P) and Flow (Q)
10 Pa 50 Pa
Power Law Equation (Bernoulli):
𝑄=𝐶(∆𝑃)↑𝑛
Where, Q = flow C = flow coefficient P = pressure n = flow exponent (dimensionless).
n = flow exponent
![Page 7: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/7.jpg)
Flow exponent (n)
Power Law Equation:
2
2.05
2.1
2.15
2.2
2.25
2.3
2.35
2.4
2.45
2.5
0.8 1 1.2 1.4 1.6 1.8 2
log Flow
log Pressure
log Flow vs log Pressure
Series1 Linear (Series1)
> 0.5 and < 1.0 Slope = n
0.5 = Turbulent • flow resistance varies with the square of velocity
1.0 = Laminar flow
• flow resistance proportional to velocity
𝑦 = 𝑚𝑥 + 𝑏
![Page 8: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/8.jpg)
à 13-story MURB
à Enclosure retrofit 2012
à focus on air tightness
à Air leakage tested
à Pre-retrofit
à Post-retrofit
Case study building
![Page 9: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/9.jpg)
Guarded-zone method
![Page 10: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/10.jpg)
Flow exponent values – Case study building Suite 101 Suite 102 Suite 301 Suite 302 Suite 303 Pre-press 0.59 0.56 0.60 0.68 0.54 Post-press 0.56 0.67 0.75 0.85 0.85 Change2 -0.03 +0.11 +0.15 +0.17 +0.31 Pre-depress 0.92 0.80 0.50 0.62 0.61 Post-depress 0.79 0.69 0.60 0.57 0.37 Change -0.13 -0.11 +0.10 -0.05 -0.24 Suite 1101 Suite 1102 Suite 1103 Suite 1301 Suite 1302 Pre-press 0.52 0.49 0.53 0.74 0.52 Post-press 0.71 0.56 0.64 0.77 0.72 Change +0.19 +0.07 +0.11 +0.03 +0.20 Pre-depress 0.47 0.46 0.78 0.57 0.63 Post-depress 0.61 0.43 0.59 0.57 0.47 Change +0.14 -0.03 -0.19 0.00 -0.16 1 pre-press = pre-retrofit pressurization, post-press = post-retrofit depressurization, pre-depress = pre-retrofit depressurization, post-depress = post-retrofit depressurization 2 positive change indicates a move towards laminar flow (smaller cracks), negative change indicates a move towards turbulent flow (larger cracks)
![Page 11: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/11.jpg)
“…blower door tests occasionally yield exponents less than the
Bernoulli limit of 0.5. In fact, it is physically impossible for such
low exponents to occur.”
Sherman, Wilson and Kiel. 1986
Flow exponents outside of theoretical range
So why do we get them?
![Page 12: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/12.jpg)
Flow Exponents <0.5
Series 1: n=0.5-1.0 Series 2: n<0.5
Q P logQ logP n r-sq Q P logQ logP n r-sq
800 10 2.9 1 0.63 0.999 800 10 2.9 1 0.42 0.999
1600 30 3.2 1.48
1300 30 3.11 1.48
2200 50 3.34 1.7 1590 50 3.2 1.7
2500 60 3.4 1.78 1710 60 3.23 1.78
![Page 13: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/13.jpg)
Flow exponents <0.5
R² = 0.9999
R² = 0.9993
2.8
2.9
3
3.1
3.2
3.3
3.4
3.5
0.9 1.1 1.3 1.5 1.7 1.9
Log Flow
Log Pressure
n = 0.63 n = 0.42
![Page 14: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/14.jpg)
Geometry of the Enclosure
à Higher pressure differentials change leakage path geometry
à Resulting in abnormal flow exponent (n) values.
50 Pa 10 Pa à What effect on the data does a changing n
value cause?
![Page 15: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/15.jpg)
Extrapolating to lower pressure differentials
40 L/s
Difference of ~35%
n = 0.40
n = 0.65
n = 0.50
n = 0.80
![Page 16: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/16.jpg)
Q P
650 30 865 50
1100 70 1180 75 1250 80 1375 90
Enclosure change at high pressure
Q P
650 30 865 50
1100 70 1150 75 1200 80 1250 90
N = 0.68, Rsq = 0.99
N = 0.62, Rsq = 0.99
![Page 17: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/17.jpg)
600700800900100011001200130014001500
20 40 60 80 100
Flow
Pressure
static enclosure enclosure changes
Enclosure change at higher pressures
1000
1050
1100
1150
1200
1250
1300
1350
1400
65 70 75 80 85 90 95
Flow
Pressure
static enclosure enclosure changes
![Page 18: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/18.jpg)
600700800900100011001200130014001500
20 40 60 80 100
Flow
Pressure
static enclosure enclosure changes
Adjusted values using n
0
200
400
600
800
1000
1200
1400
0 20 40 60 80
Flow
Pressure
static enclosure changing enclosure
0
50
100
150
200
250
2 3 4 5 6
Flow
Pressure
static enclosure changing enclosure
25 l/s
14% difference
![Page 19: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/19.jpg)
à The enclosure may not remain static throughout the
test
à The linear relationship may not be accurate at operating
pressure
à Substituting n values can have magnified impacts at
lower/higher pressure differentials
à R-squared values not perfect indicators
Conclusions
![Page 20: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/20.jpg)
à Sizing mechanical systems
for predicted in operation
flow rates
à Retrofit options
Implications for the industry
à Energy models using extrapolated flow rates
may be inaccurate
![Page 21: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/21.jpg)
à Multi-point testing still important
à Order of magnitude for comparison purposes
à Flow exponents tell us something, we might not know
exactly what it is
à Standards at higher pressures can be used for
compliance purposes
The Good
![Page 22: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/22.jpg)
In-test corrections
à Check R-squared values during testing
à Check n values at the termination of each test
Post-test corrections
à Review data points and remove lowest pressure
differential point(s)
à If not reconciled, single point test at 50 Pa
Flow exponent corrections
![Page 23: NBEC 2014 - Flow Exponent Values and Implications for Air Leakage Testing](https://reader031.vdocuments.us/reader031/viewer/2022032010/55a686f81a28ab3f1e8b4579/html5/thumbnails/23.jpg)
à Sensitivity analysis: R-value threshold
à The use of flow exponent values in forensics
à Standardized leakage metric and pressure differential
for comparison purposes
à Effect on flow exponent of enclosure geometry
changes
Further study