natural air ventilators...louvre and damper frame extruded aluminium grade enaw 6063t6 to bsen 755....

13
Ruskin Air Management Limited www.ruskinuk.co.uk November 2012 l Manual Control l Motor Control l Fail Safe Open/Close l Anti-Finger Trap l Heating Coils with Optional Fan Assistance l Acoustic Options l Roof Terminals l Mixed Mode via Fan Coils l Control Panels l Choice of External Louvres l Choice of Internal Grilles Natural Air Ventilators Metal louvre / damper combination C1/SfB (31.8) Xh4 November 2012

Upload: others

Post on 27-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Ruskin Air Management Limitedwww.ruskinuk.co.uk

November 2012

l Manual Control

l Motor Control

l Fail Safe Open/Close

l Anti-Finger Trap

l Heating Coils with Optional Fan Assistance

l Acoustic Options

l Roof Terminals

l Mixed Mode via Fan Coils

l Control Panels

l Choice of External Louvres

l Choice of Internal Grilles

Natural AirVentilators

Metal louvre / damper combination

C1/SfB (31.8) Xh4 November 2012

Page 2: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Our ideas built with you in mind 3

Natural Ventilation Theory/ Naco Product Solutions 4-5

Generic BuildingCross Section 6-7

NAV WI & WA 8

NAV WA+ 9

NAV WL & WLI 10

NAV WI/HC & WA/HC 11

NAV WI/HC/DBF & WA/HC/DBF 12

NAV Roof Terminal RT/RTD 13

Heating Coil 14

Dynamic Fan System 15

Fan Coils 16

Complimentary Products 17

Control Options 18-19

Specification Details 20-21

Photographs / Misc 22-23

When someone says it can’t be done, they’ve obviously not spoken to us. So if anyone in the industry suggests that you are asking for the impossible, it will always be our privilege to prove them wrong yet again.

From start to finishBecause unlike most UK louvre companies, we design, detail, supply and install. So not only do our products match your requirements precisely in terms of function but also in style, finish and colour.

This determination to see things through to the finished result gives architects and designers a unique opportunity to create outstanding ventilation features or screening controls within the external cladding. And our can-do attitude makes those satisfied clients come back to us time and time again.

Past, present and future Since the early sixties this customer-first philosophy has been enshrined in all our activities. Blended with manufacturing experience and practical expertise honed over almost half a century, it has seen Naco define everything from metal and glass louvres, natural air and smoke ventilators to mist separators, sunscreens and brise soleil.

It even instigated a no-nonsense software program on our website to take the hassle out of sizing louvres and unscrambling such things as face, jet or core velocities and free areas.

An ideal environmentBut user friendliness isn’t the only challenge facing building design today. Increasingly environmental friendliness is nowa design pre-condition, reflecting a growing duty to protectthe natural environment whilst controlling our owninternal environments.

Learning to harness nature’s elements to our advantage rather than simply fighting against them is now driving forward our engineering and design teams more than ever. And their progress can be measured by the comprehensive rangeof Natural Air Ventilators featured here in our latestproduct portfolio.

Our ideas built with you in mind

Contents

Learning to harness nature’s elements

www.naco.co.uk

3

www.naco.co.uk

2

Page 3: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Natural Ventilation Theory/ Naco Product Solutions

Ventilation with fan system

Fan Coil unit

Stairwell

Summer

Ventilation with heater coil and fan system

Fan Coil unit

Stairwell

Winter

Cool fresh air

Positive Pressure

Warm stale air

Windward Side

Wind Direction Wind Driven

Leeward Side

Negative Pressure

Warm stale air Warm stale air

Cool fresh air

Warm staleair rising

Cool fresh air

Stack DrivenStack Effect(Chimney Effect)

This method does not rely so much on the wind, but more on the buoyancy affect created by the warmer air inside the building being less dense thanthe outside cooler air.

By the use of a roof terminal orhigh-level ventilators, the warmer stale air will rise up and exhaust through the high level ventilators, and this movement of air will draw in the outside air at low level.

The stack effect method is usually more reliable than the wind driven one.

Wind Effect

The wind blowing against the building (Windward) side creates a positive pressure on that sideof the building. This in turn creates a negative pressure on the opposite side (Leeward) side.

Through the correct positioning of ventilators to both sides of the building, often together with a roof terminal, airflow is produced flowing from the windward side towards the leeward side.

l Natural ventilation systems have now become the favoured approach to providing the ventilation solutions for schools, universities and low-rise buildings in general.

l Natural ventilation offers significant benefits over mechanical systems on these types of buildings.

l Significant cost savings, both on the initial installation cost and the ongoing service & maintenance costs are evident.

l Running costs are also significantly lower, with little or no power consumption required, depending on the type of system selected.

l Construction costs can also be reduced, whilst giving the architect more room for manoeuvre, as there is no longer any need to allow for plant rooms.

l Free night cooling is also readily available to reduce energy loads on the building.

l There is also evidence that natural ventilation systems offer health benefits to the building occupants, with cases of ‘Sick Building Syndrome’ becoming a thing of the past.

NaturalVentilationPrinciples

Mixed Mode (Hybrid System)

To allow building designers greater flexibility and to alleviate some of the vagaries that our weather can have on the efficient function of both the wind driven and stack systems, Ruskin can offer a mixed mode system, to compliment a totally natural system.

This can encompass a range of NAV ventilators fitted with heating coils, either with or without fan assistance andfan coil units.

Control systems would enable the motorised items in the hybrid system to only be called on when deemed necessary.

Mixed mode is particularly useful for winter heating and summer cooling applications when the natural system might struggle to provide the optimum room ventilation conditions.

Wind Driven Summer

Winter

Natural Ventilation Benefits

Stack Driven

www.naco.co.uk

5

www.naco.co.uk

4

Page 4: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Generic BuildingCross Section

Solar ShadingReduces the heat gain into buildings and therefore lowers the ventilation and energy requirements.

Nav UnitsProvide controlled naturalventilation and free night cooling. Optional tempering of the incoming air.

Transfer Grilles (G45)A convenient way to allow air to pass through internal partitions, towards the roof terminal zones.

Fan CoilsFan Coils have been chosen from the proven Actionair range and are based on the Hydropac eco friendly unit Model EC. Featuring low noise, low energy fans with minimal fan heat with full acoustic and thermal insulation.

Fan Floor SwirlsCan be considered for use in floor void situations. The fan will induce cool fresh air at low level and this will displace the warm stale air through the extract or transfer grilles.

Vengen Glass LouvresProvide controlled ventilation with high free areas and the added benefit of daylight.

Roof TerminalsProvide an efficient method of allowingthe warm stale air to escape. Also theyare used for allowing the entry of fresh outside air in wind driven applications.

The primary components of our Natural Ventilation range are the NAV units detailed on pages 8-13. However several more products from Ruskin Air Management Ltd are available that are perfectly suited to enhancing a natural ventilation scheme.

A number of these products are showcased on the building below and are described on page 17 under ‘Complimentary Products’.

www.naco.co.uk

7

www.naco.co.uk

6

Page 5: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Acoustic Ventilator – NAV WAInsulated Ventilator – NAV WI

Specification

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755.

Frame ConstructionThermally broken frame & damper blades. Screw joints as standard.

External Louvre OptionsSlimtype, 50, 75, SLH-S.

Optional Internal GrilleIf required NAV WA & WI can be specified with a choice of internal grilles from the Air Diffusion range.

FinishesExtruded aluminium (mill finish) Polyester powder coated to BS 6496.

Anodised to BS 3987.

Bird Wire GuardFitted as standard,18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Free AreaSLH-S 53%75S 50%50S 47%Slimtype 40%

CdSLH-S 0.31275S / 50S 0.213Slimtype 0.161

Air Leakage at 50 PaLength of joint: 0.1m3/h/mArea: 0.6 m3/h/m2

Wind Driven Rain RatingSLH-S and SlimtypeClass A up to 1 m/s75S and 50SClass B up to 1 m/s

Operation(1) Manual handle*(Not available if internal grille is specified).

(2) 24V AC 10Nm actuator with modulating action or simply driveopen and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

(4) 24 V DC linear type motorwith ‘anti-finger trap’ function.*(A minimum ventilator heightapplies to this option).

Damper Blade Type WAThe acoustic panel provides approximately 32 Db soundreduction in the closed position.

Damper Blade Type WIThe insulated panel is rated at1.15W/m2 K thermal value.(Specific U values for any givensize of ventilator can be provided. Please consult our Sales Office).

SizesSingle ventilator minimum300 W x 330 H (7Nm & 10Nm actuators)300 W x 403 H (Manual handle)300 W x 565 H (Anti-finger trap)

Single ventilator maximum1400 W x 2400 H

Double ventilator maximum2800 W x 1500 H

Note: Slimtype louvres willbe restricted to a standardmaximum size of either1000 W x 2400 H or2800 W x 1000 H

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755.

Frame ConstructionThermally broken frame & damper blades. Screw joints as standard.

Acoustic TreatmentInternal chevron type, acoustic louvre. Acoustic lining to interior of ventilator casing.

External Louvre OptionsSlimtype, 50, 75, SLH-S.

Internal Grille OptionsN/A

FinishesExtruded aluminium (mill finish)Polyester powder coated to BS 6496. Anodised to BS 3987.

Bird Wire GuardFitted as standard,18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Operation(2) 24V AC 10Nm actuator with modulating action or simply drive open and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

Damper Blade Type WA+In most circumstances blade type WA would be used, however blade type WI is also available.

SizesSingle ventilator minimum.300 W x 330 H

Single ventilator maximum.1400 W x 2400 H

Double ventilator maximum.2800 W x 1500 H

Note: Slimtype louvres will be restricted to a standard maximum size of either 1000 W x 2400 H or 2800 W x 1000 H

CouplingVentilators may be coupled horizontally or vertically.

Free AreaCirca 40% (all variants)

Air Leakage at 50 PaLength of joint: 0.1m3/h/mArea: 0.6 m3/h/m2

Wind Driven Rain RatingClass A up to 1m/s (all variants)

Acoustic RatingClosed 24 Db 25% open 15 Db 50% open 11 Db75% open 8 Db

WA & WI

Slimtype = 22350S = 25775S = 277

SLH-S = 307

Slimtype = 28250S = 29875S = 332

SLH-S = 352

Overall Channel

Ove

rall

Cha

nnel

Slimtype = 22350S = 25775S = 277

SLH-S = 307

Slimtype = 28250S = 29875S = 332

SLH-S = 352

Overall Channel

Ove

rall

Cha

nnel

Specification

WA +A general purpose range of Natural Air Ventilators combining class leading air-tightness, togetherwith excellent ‘U’ values and sound reduction.

Maintains the features of the NAV WA & WI andprovides enhanced sound reduction capabilities.

Op

tiona

l Int

erna

l Gril

le

Optional Internal Grille

www.naco.co.uk

9

www.naco.co.uk

8

Page 6: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755.

Frame ConstructionScrew joints as standard.

External Louvre OptionsSlimtype, 50, 75, SLH-S

Optional Internal GrilleIf required NAV WL & WLI can be specified with a choice of internal grilles from the Air Diffusion range.

FinishesExtruded aluminium (mill finish)Polyester powder coated toBS 6496. Anodised to BS 3987.

Bird Wire GuardFitted as standard,18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Free AreaSLH-S 53%75S 50%50S 47%Slimtype 40%

CdSLH-S 0.3675S / 50S 0.24Slimtype 0.19

Wind Driven Rain RatingSLH-S and SlimtypeClass A up to 1 m/s75S and 50SClass B up to 1 m/s

Operation(1) Manual handle*(Not available if internal grilleis specified).

(2) 24V AC 10Nm actuator with modulating action or simply drive open and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

Damper Blade Type WLSolid skin extruded aluminium.

Damper Blade Type WLI31mm thick composite insulation panel xps & alveo foam bonded to 1.5 powder coated aluminium sheet. The insulated panel is rated at 1.15W/m2 (Specific U values for any given size of ventilator can be provided. Please consult ourSales Office).

SizesNote: Slimtype louvres will be restricted to a standard maximum size of either 1000 W x 2400 H or 2800 W x 1000 H

CouplingVentilators may be coupled horizontally or vertically.

Air Leakage at 50 PaLength of joint: 0.5 m3/h/mArea: 4.1 m3/h/m2

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6to BSEN 755.

Frame ConstructionThermally broken frame & damper blades. Screw Joints as standard.

Heating CoilRefer to page 14 fortechnical details.

External Louvre OptionsSlimtype, 50, 75, SLH-S

Internal Grille OptionsA range of grilles are available from the Air Diffusion range.

FinishesExtruded aluminium (mill finish)Polyester powder coatedto BS 6496. Anodised to BS 3987.

Bird Wire GuardFitted as standard,18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Free AreaN/A

CdN/A

Air Leakage at 50 PaLength of joint: 0.1m3/h/mArea: 0.6 m3/h/m2

Wind Driven Rain RatingSLH-S and SlimtypeClass A up to 1 m/s 75S and 50SClass B up to 1 m/s

Operation(2) 24V AC 10Nm actuator with modulating action or simply drive open and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

Damper Blade Type WAThe acoustic panel provides approximately 32 Db sound reduction in the closed position.

Damper Blade Type WIThe insulated panel is rated at 1.15W/m2 K thermal value.(Specific U values for any given size of ventilator can be provided. Please consult our Sales Office).

SizesA wide variety of sizes are available, please consult our Sales Office for your specific requirements.

CouplingVentilators may be coupled horizontally or vertically.

WL & WLI

Specification

WI/HC & WA/HC

A budget range of ventilatorsmaintaining very good air-tightness.

Maintains the features of the NAV WA & WI but fittedwith a heating coil to temper the incoming air.

Ove

rall

Cha

nnel

Overall Channel

SLIMTYPE = 32550S = 36075S = 380

SLH-S = 410

Ove

rall

Cha

nnel

Overall Channel

SLIMTYPE = 32550S = 36075S = 380

SLH-S = 410

Op

tiona

l Int

erna

l Gril

le

Optional Internal Grille

www.naco.co.uk

11

www.naco.co.uk

10

Page 7: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755.

Frame ConstructionThermally broken frame & damper blades. Screw joints as standard.

Heating CoilRefer to page 14 fortechnical details.

Dynamic Boost FanRefer to page 15 fortechnical details.

External Louvre OptionsSlimtype, 50, 75, SLH-S.

Internal Grille OptionsA range of grilles are available from the Air Diffusion range.

FinishesExtruded aluminium (mill finish)Polyester powder coatedto BS 6496. Anodised to BS 3987.

Bird Wire GuardFitted as standard,18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Free AreaN/A

CdN/A

Air Leakage at 50 PaLength of joint: 0.1m3/h/mArea: 0.6 m3/h/m2

Wind Driven Rain RatingSLH-S and SlimtypeClass A up to 1 m/s 75S and 50SClass B up to 1 m/s

Operation(2) 24V AC 10Nm actuator with modulating action or simply drive open and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

Damper Blade Type WAThe acoustic panel provides approximately 32 Db sound reduction in the closed position.

Damper Blade Type WIThe insulated panel is rated at 1.15W/m2 K thermal value. (Specific U values for any given size of ventilator can be provide. Please consult our Sales Office).

SizesA wide variety of sizes are available, please consult our Sales Office for your specific requirements.

CouplingVentilators may be coupled horizontally or vertically.

MaterialsLouvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755.

Frame ConstructionScrew joints as standardMitred and welded corners.Pressed aluminium roof.

External Louvre OptionsSLH-S.

FinishesExtruded aluminium (mill finish)Polyester powder coated to BS 6496. Anodised to BS 3987.

Bird Wire GuardFitted as standard, 18g expanded aluminium.

Insect ScreenIf specified, 23g expanded aluminium.

Free Area53%

Cd0.261

Air Leakage at 50 PaLength of joint: 0.1m3/h/mArea: 0.6 m3/h/m2

Wind Driven Rain RatingClass A up to 1 m/s

Operation(2) 24V AC 10Nm actuator with modulating action or simply drive open and drive closed.

(3) 24V AC/DC 7Nm ‘fail-safe’ spring open or close actuator with modulating action or simply spring open and drive close (or vice-versa).

Damper Blade Type WAThe acoustic panel provides approximately 32 Db sound reduction in the closed position.

Damper Blade Type WIThe insulated panel is rated at 1.15W/m2 K thermal value.(Specific U values for any given size of ventilator can be provide. Please consult our Sales Office).

SizesL x W x H

WI/HC/DBF &WA/HC/DBF

Maintains the features of the NAV WI/HC & WA/HC withthe ability to temper the incoming air with fan assistance.

Roof Terminal Air Inlet – Air Exhaust

Specification

RT/RTD

Slimtype = 37350S = 40875S = 428

SLH-S = 458

Overall Channel

Ove

rall

Cha

nnel

L W

H

L W

H

Slimtype = 37350S = 40875S = 428

SLH-S = 458

Overall Channel

Ove

rall

Cha

nnel

www.naco.co.uk

13

www.naco.co.uk

12

Page 8: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification

Benefits

Control of Dynamic Fan System

Modes

Pressure Drop Charts

Heating Coil Type 19Is a low - H20 heat exchanger which enables efficient output to be received at low flow temperatures. Tested to 20 bar. Working pressure 10 bar.

Pipework Connections1/2” BSP female connections can be of ‘Standard’ Type or ‘Alternative’ Type (see illustration)

1/2” BSP Drain Connection1/2” BSP Vent Connection

During times when the outside air movement is not favourable to a natural ventilation system, the Dynamic Fan System can assist to create passive ventilation of cool air in summer or increases the heat output from the heating coil to the occupied zone on colder days.

The Dynamic Fan System simply ‘snap’ fits over the heating coil and requires a 220V AC electrical supply locally to supply the 24v DC transformer supplied with the system.

Every set includes a control panel, control unit, power supply and instruction manual.

The panel is fitted with a water temperature sensor and a room temperature sensor both of which continue to operate the system in Automatic Mode simply by selecting a room temperature (the factory setting is position 6 that configurates to a value of 22°C).

Automatic: The spread of the fan will automatically modulate until desired temperature is reached with the fan speed dropping to a standstill at the set level.

Boost: Fan will run at maximum speed for 15 minutes before returning to automatic.

Passive Mode: TBC

During certain times of the year outside air may be too cold for direct entry into the building. Therefore a heating coil can temper the incoming air to allow the desired ventilation rates to take place.

Heating Coil Dynamic FanSystem

The inclusion of a heating coil allows extra flexibilityto your natural ventilation system.

201

Tech

nica

l inf

o

Type Knockonwood Strada Linea Plus Mini Mini Canal Canal Plus H / B Canal Compact

04 other end - - - - 5004.04/BS10 - - - - 09-11/14

05 - - - 5003.05/BS9 5003.05/BS10 - - - - 14/14

06 - - - 5003.06/BS9 - - - - 5003.06

07 - 5003.07* - - - - - - -

08 5003.08** 5003.08** - - - - - - -

09 - - - - 5003.09/BS10 - - - - 09-11/18

09 other end - - - 5004.09/BS9 - - - - -

10 5003.10 5003.10 5003.10 5003.10/BS9 5003.10/BS10 5003.10 5003.10 5003.10 5003.10 14-19/26

11 5003.11 5003.11 5003.11 5003.11/BS9 - - 5003.11 5003.11 -

14 - - - - 5003.14/BS10 - - - - 09-11/34

14 other end - - - 5004.14/BS9 - - - - -

15 5003.15 5003.15 5003.15 5003.15/BS9 5003.15/BS10 5003.15 5003.15 5003.15 - 14-19/34

16 5003.16 5003.16 5003.16 5003.16/BS9 - - 5003.16 5003.16 -

19 - - -- 5004.19/BS10 - - - - - 09-11/42

19 other end - - - 5004.19/BS9 - - - - -

20 - 5003.20 5003.20 5003.20/BS9 5003.20/BS10 5003.20 5003.20 5003.20 - 14-19/42

21 - 5003.21 5003.21 5003.21/BS9 - - 5003.21 5003.21 -

Heat exchanger per appliance. Overview codes:

Overview heat exchangers

* Strada type 06 height 20 ** Knockonwood and Strada type 06 all other heights

Installation into pre-formed duct

Installation into a wall recess

Installationunder bath

5 10 15

5

5

10

20

208

15

Type 04 Type 09 Type 14 Type 19 other end connection other end connection other end connection other end connection

Type 09 Type 14 Type 19

Type 05 Type 07 Type 10 Type 15 Type 20

Type 06 Type 08 Type 11 Type 16 Type 21

201

Tech

nica

l inf

o

Type Knockonwood Strada Linea Plus Mini Mini Canal Canal Plus H / B Canal Compact

04 other end - - - - 5004.04/BS10 - - - - 09-11/14

05 - - - 5003.05/BS9 5003.05/BS10 - - - - 14/14

06 - - - 5003.06/BS9 - - - - 5003.06

07 - 5003.07* - - - - - - -

08 5003.08** 5003.08** - - - - - - -

09 - - - - 5003.09/BS10 - - - - 09-11/18

09 other end - - - 5004.09/BS9 - - - - -

10 5003.10 5003.10 5003.10 5003.10/BS9 5003.10/BS10 5003.10 5003.10 5003.10 5003.10 14-19/26

11 5003.11 5003.11 5003.11 5003.11/BS9 - - 5003.11 5003.11 -

14 - - - - 5003.14/BS10 - - - - 09-11/34

14 other end - - - 5004.14/BS9 - - - - -

15 5003.15 5003.15 5003.15 5003.15/BS9 5003.15/BS10 5003.15 5003.15 5003.15 - 14-19/34

16 5003.16 5003.16 5003.16 5003.16/BS9 - - 5003.16 5003.16 -

19 - - -- 5004.19/BS10 - - - - - 09-11/42

19 other end - - - 5004.19/BS9 - - - - -

20 - 5003.20 5003.20 5003.20/BS9 5003.20/BS10 5003.20 5003.20 5003.20 - 14-19/42

21 - 5003.21 5003.21 5003.21/BS9 - - 5003.21 5003.21 -

Heat exchanger per appliance. Overview codes:

Overview heat exchangers

* Strada type 06 height 20 ** Knockonwood and Strada type 06 all other heights

Installation into pre-formed duct

Installation into a wall recess

Installationunder bath

5 10 15

5

5

10

20

208

15

Type 04 Type 09 Type 14 Type 19 other end connection other end connection other end connection other end connection

Type 09 Type 14 Type 19

Type 05 Type 07 Type 10 Type 15 Type 20

Type 06 Type 08 Type 11 Type 16 Type 21

201

Tech

nica

l inf

o

Type Knockonwood Strada Linea Plus Mini Mini Canal Canal Plus H / B Canal Compact

04 other end - - - - 5004.04/BS10 - - - - 09-11/14

05 - - - 5003.05/BS9 5003.05/BS10 - - - - 14/14

06 - - - 5003.06/BS9 - - - - 5003.06

07 - 5003.07* - - - - - - -

08 5003.08** 5003.08** - - - - - - -

09 - - - - 5003.09/BS10 - - - - 09-11/18

09 other end - - - 5004.09/BS9 - - - - -

10 5003.10 5003.10 5003.10 5003.10/BS9 5003.10/BS10 5003.10 5003.10 5003.10 5003.10 14-19/26

11 5003.11 5003.11 5003.11 5003.11/BS9 - - 5003.11 5003.11 -

14 - - - - 5003.14/BS10 - - - - 09-11/34

14 other end - - - 5004.14/BS9 - - - - -

15 5003.15 5003.15 5003.15 5003.15/BS9 5003.15/BS10 5003.15 5003.15 5003.15 - 14-19/34

16 5003.16 5003.16 5003.16 5003.16/BS9 - - 5003.16 5003.16 -

19 - - -- 5004.19/BS10 - - - - - 09-11/42

19 other end - - - 5004.19/BS9 - - - - -

20 - 5003.20 5003.20 5003.20/BS9 5003.20/BS10 5003.20 5003.20 5003.20 - 14-19/42

21 - 5003.21 5003.21 5003.21/BS9 - - 5003.21 5003.21 -

Heat exchanger per appliance. Overview codes:

Overview heat exchangers

* Strada type 06 height 20 ** Knockonwood and Strada type 06 all other heights

Installation into pre-formed duct

Installation into a wall recess

Installationunder bath

5 10 15

5

5

10

20

208

15

Type 04 Type 09 Type 14 Type 19 other end connection other end connection other end connection other end connection

Type 09 Type 14 Type 19

Type 05 Type 07 Type 10 Type 15 Type 20

Type 06 Type 08 Type 11 Type 16 Type 21

201

Tech

nica

l inf

o

Type Knockonwood Strada Linea Plus Mini Mini Canal Canal Plus H / B Canal Compact

04 other end - - - - 5004.04/BS10 - - - - 09-11/14

05 - - - 5003.05/BS9 5003.05/BS10 - - - - 14/14

06 - - - 5003.06/BS9 - - - - 5003.06

07 - 5003.07* - - - - - - -

08 5003.08** 5003.08** - - - - - - -

09 - - - - 5003.09/BS10 - - - - 09-11/18

09 other end - - - 5004.09/BS9 - - - - -

10 5003.10 5003.10 5003.10 5003.10/BS9 5003.10/BS10 5003.10 5003.10 5003.10 5003.10 14-19/26

11 5003.11 5003.11 5003.11 5003.11/BS9 - - 5003.11 5003.11 -

14 - - - - 5003.14/BS10 - - - - 09-11/34

14 other end - - - 5004.14/BS9 - - - - -

15 5003.15 5003.15 5003.15 5003.15/BS9 5003.15/BS10 5003.15 5003.15 5003.15 - 14-19/34

16 5003.16 5003.16 5003.16 5003.16/BS9 - - 5003.16 5003.16 -

19 - - -- 5004.19/BS10 - - - - - 09-11/42

19 other end - - - 5004.19/BS9 - - - - -

20 - 5003.20 5003.20 5003.20/BS9 5003.20/BS10 5003.20 5003.20 5003.20 - 14-19/42

21 - 5003.21 5003.21 5003.21/BS9 - - 5003.21 5003.21 -

Heat exchanger per appliance. Overview codes:

Overview heat exchangers

* Strada type 06 height 20 ** Knockonwood and Strada type 06 all other heights

Installation into pre-formed duct

Installation into a wall recess

Installationunder bath

5 10 15

5

5

10

20

208

15

Type 04 Type 09 Type 14 Type 19 other end connection other end connection other end connection other end connection

Type 09 Type 14 Type 19

Type 05 Type 07 Type 10 Type 15 Type 20

Type 06 Type 08 Type 11 Type 16 Type 21

Type 19 Standard

Type 19 Alternative

Heat Output Against Flow Rate

64

DB

E

The components of the DBE system are easily snapped onto the Low-H20 heat exchanger using tension springs. This causes no hydraulic changes in the heating installation, however you should take account of the increased output of the Low-H2O radiators when sizing the installation. Furthermore, only a single 220 VAC supply needs to be provided locally. This supply point can be located invisibly behind the casing. The power supply provided should not be used with a direct 12 VDC supply. For freestanding appliances the power supply is via the feet of the appliance.The number of DBE units per radiator depends on the length of the Low-H20 heat exchanger, with a maximum of 6 DBE units coupled up in series. The type of casing also has an effect

on the possible number of DBE units.

Connection 12 VDCTake into account the + and - when using your own power supply. If not, the Control unit will be damaged.

1

2

CoDe Description £

DBED.C01 DBE communication software and cable 56.40DBED.C02 DBE communication software + USB 96.60

Programming own user profileWant to construct your own user profile? The DBE microprocessor board has a communica-tion port.The DBE system can be reconfigured via this port: water temperature, revs, duration of boost, etc, can be changed.This involves a modification of the standard parameters. In order to do this you need a PC with DBE communication software. The operation of the software is explained via a help function. A CD-ROM and connecting ca-ble are available, as well for RS 232 - as USB connection.Future upgrades of this communication soft-ware can be freely downloaded from the Jaga website.URL: http://www.jaga.be/drivers/JAGA_DBE_CUSTOMERS.zip

DBe_Installation

Adjustment and operationSet the maximum desired comfort temperatu-re using the multi-position switch on the mi-croprocessor board. Every position (from 0 to 9) corresponds to a maximum desired value. The board also has a table of these values. Position 6 is the standard factory setting. This corresponds to a value of 22°C (room tempe-rature).The system is now controlled fully automa-tically. The microprocessor measures the room temperature and the average water temperature in the Low-H20 heat exchanger. These measurements are processed and the microprocessor determines the correctly mo-dulated speed of the activator depending on the comfort temperature set. This means the activators will run faster if the temperature is significantly below the desired level. As the temperature rises, the speed drops, coming to a complete standstill when the desired temperature is reached. The system then operates completely statically. This automatic operation is the “comfort” mode.You can always demand extra heat by turning on the manual “boost” function. The system will then work at maximum power for the time set. The standard setting is 15 minutes. In or-der for the unit to operate, the water tempe-rature sensor must detect a minimum water temperature (flow) of 28°C.

Low- temperature heatingThe extremely high efficiency and power out-put at low temperatures, even on small radia-tors, make the DBE system an ideal candidate for low- temperature heating.

Water temperature sensor

Room temperature sensor

54

1 0 9

87

6

32

Set desired room tempe-rature at its maximum

no. °C no. °C

0 16° 5 21°1 17° 6 22°2 18° 7 23°3 19° 8 24°4 20° 9 Prog.

Temperature setting

➝ factory setting

-+

DC-plug

RETURN

RETURN

Type 19 standard connection

Type 19 alternative connection

INLET

INLET

Set desiredroom temperatureat its maximum

Water temperature sensor

Room temperature sensor

www.naco.co.uk

15

www.naco.co.uk

14

Page 9: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification

EHW 230 Series Waterside control 230mm deep ceiling void mounted chassis unit.

The Fan Coil selections are based on the following entering air conditions:

Cooling:Summer On-coil air 23 °C Dry Bulb,16 °C Wet Bulb.Max Coil Pd = 20kPa

Heating:Winter On-coil air temperature 20 °C Dry Bulb.Max Coil Pd = 10kPa

General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz.Please refer to our Fan Coil Technical Department for alternative conditions.* see page 11 for NR Predictions.

Main Features:

Fan Coils ComplimentaryProducts

Fan coils have been chosen from the proven Actionair range and are based on the Hydropac eco friendly unit Model EC.

• Low noise levels• Outputs available (6.4 Kw cooling) and (6.9 Kw heating)• Very low energy fans• Full acoustic and thermal insulation• BMS control• Minimal fan heat

Hydropac EC and Hydropac Fancoil Units

South Street, Whitstable, Kent CT5 3DU England.Tel: 01227 276100 Fax: 01227 264262 Email: [email protected] Website: www.actionair.co.uk

Ruskin Air Management Limited

ActionairFancoil Unit

Actionair Controls

Actionair Damper

Comprehensive and detailedinformation is available for allActionair products.

Visit our website atwww.actionair.co.uk

Air Diffusion Diffuser and Plenum Box

Comprehensive and detailedinformation is available for all Air Diffusion products.

Visit our website at www.air-diffusion.co.uk

Ruskin Air Management Limitedis a ISO 9001 and 14001registered company

Ruskin Air Management Hydropac Related Family of Products

Air DiffusionPlenum / Grille

ActionairVolume ControlDamper

ActionairFan CoilUnit

ActionairControl

Solar ShadingReduces the heatgain into buildingsand therefore lowersthe ventilation and energy requirements.

Nav UnitsProvide controlled natural ventilation and free night cooling. Optional tempering ofthe incoming air.

Fan CoilThe fan coils havebeen chosen fromthe proven Actionair range. Featuring low noise, low energyfans with minimalfan heat with full acoustic andthermal insulation.

Transfer Grille (G45)A convenient way to allow air to pass through internal partitions, towards the roof terminal zones.

Fan Floor SwirlsCan be considered for use in floor void situations. The fanwill induce cool fresh air at low level andthis will displacethe warm stale airthrough the extractor transfer grilles.

Wide Blade Bar Grille (WB)An alternative robust grille that is suitablefor use in areas such as gymnasiums.

Vengen Glass LouvresProvide controlled ventilation with highfree areas and theadded benefitof daylight.

Roof TerminalsProvide an efficient method of allowing the warm stale air to escape.Also they are used for allowing the entry offresh outside air inwind driven applications.

Hydropac EC Fancoil Units

EHW230Hydropac EC (Series EHW)Actionair Hydropac horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure hot water heating medium. Temperature control is by means of modulating 2 or 4-port diverting valves on heating and cooling, operated by stand alone or BMS controller with room or return air temperature sensor. Designated ‘EHW’, the series consists of standard 230mm (EHW230) deep. A total of 6 modes are available to achieve the required room conditions. The table below shows data for the smallest model EHW232 and largest model EHW235X.

Hydropac EC and Hydropac Fancoil Units

11 °C min air off 14 °C min air off

ChW 6°C flow,11°C return ChW 10°C flow,14°C return

Model Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R.Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide*

(Watts) (Watts) EHW

2 110 1530 1890 1180 2150 33 30

3 125 1710 2080 1300 2290 40 32

4 150 2020 2430 1520 2500 50 35

5 175 2320 2800 1730 2700 61 38

6 185 2400 2890 1780 2800 68 40

2 175 2450 3020 1830 3200 45 30

3 200 2800 3460 2070 3400 58 32

4 240 3360 4150 2460 3800 76 35

5 280 3920 4850 2870 4100 90 38

6 305 4270 5270 3110 4400 101 40

2 170 2660 3460 1970 3810 44 30

3 210 3200 4160 2360 4200 61 32

4 255 3650 4950 2820 4610 81 35

5 300 4000 5740 3280 5010 97 38

6 330 4200 6050 3530 5300 109 40

2 195 2800 3400 2150 4110 50 30

3 235 3350 4050 2610 4410 68 32

4 290 4000 4770 3180 4910 92 35

5 340 4300 4960 3680 5410 109 38

6 375 4500 5100 4010 5700 124 40

2 185 2650 3210 2000 4510 48 30

3 225 3100 3710 2400 4910 65 32

4 280 4000 4830 3010 5410 89 35

5 340 4800 5800 3640 5910 109 38

6 375 5300 6400 3920 6310 124 40

2 230 3300 4010 2550 4910 67 30

3 275 3900 4720 2990 5410 87 32

4 340 4800 5800 3640 5910 109 35

5 405 5400 6370 4290 6510 134 38

6 445 5600 6450 4670 6910 160 40

Cooling:Summer On-coil air 23 °C Dry Bulb, 16 °C Wet Bulb. Max Coil Pd = 20kPa

Heating:Winter On-coil air temperature 20 °C Dry Bulb. Max Coil Pd = 10kPa

The Fan Coil selections are based on thefollowing entering air conditions:

General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz.Please refer to our Fan Coil Technical Department for alternative conditions.

* see page 11 for NR Predictions.

Waterside control 230mm deep ceiling void mounted chassis unit

LPHW 82°C flow 72°C return

EHW 230 Series

EHW232

EHW233

EHW234

EHW234X

EHW235

EHW235X

Thermal Performance Data

6 www.actionair.co.uk

Hydropac EC and Hydropac Fancoil Units

11 °C min air off 14 °C min air off

ChW 6°C flow,11°C return ChW 10°C flow,14°C return

Model Speed Airflow Sensible Total Sensible/Total Cooling Heating Fan Input N.R.Setting (I/s) Cooling Cooling (Watts) (Watts) (Watts) Guide*

(Watts) (Watts) EHW

2 110 1530 1890 1180 2150 33 30

3 125 1710 2080 1300 2290 40 32

4 150 2020 2430 1520 2500 50 35

5 175 2320 2800 1730 2700 61 38

6 185 2400 2890 1780 2800 68 40

2 175 2450 3020 1830 3200 45 30

3 200 2800 3460 2070 3400 58 32

4 240 3360 4150 2460 3800 76 35

5 280 3920 4850 2870 4100 90 38

6 305 4270 5270 3110 4400 101 40

2 170 2660 3460 1970 3810 44 30

3 210 3200 4160 2360 4200 61 32

4 255 3650 4950 2820 4610 81 35

5 300 4000 5740 3280 5010 97 38

6 330 4200 6050 3530 5300 109 40

2 195 2800 3400 2150 4110 50 30

3 235 3350 4050 2610 4410 68 32

4 290 4000 4770 3180 4910 92 35

5 340 4300 4960 3680 5410 109 38

6 375 4500 5100 4010 5700 124 40

2 185 2650 3210 2000 4510 48 30

3 225 3100 3710 2400 4910 65 32

4 280 4000 4830 3010 5410 89 35

5 340 4800 5800 3640 5910 109 38

6 375 5300 6400 3920 6310 124 40

2 230 3300 4010 2550 4910 67 30

3 275 3900 4720 2990 5410 87 32

4 340 4800 5800 3640 5910 109 35

5 405 5400 6370 4290 6510 134 38

6 445 5600 6450 4670 6910 160 40

Cooling:Summer On-coil air 23 °C Dry Bulb, 16 °C Wet Bulb. Max Coil Pd = 20kPa

Heating:Winter On-coil air temperature 20 °C Dry Bulb. Max Coil Pd = 10kPa

The Fan Coil selections are based on thefollowing entering air conditions:

General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz.Please refer to our Fan Coil Technical Department for alternative conditions.

* see page 11 for NR Predictions.

Waterside control 230mm deep ceiling void mounted chassis unit

LPHW 82°C flow 72°C return

EHW 230 Series

EHW232

EHW233

EHW234

EHW234X

EHW235

EHW235X

Thermal Performance Data

6 www.actionair.co.uk

www.naco.co.uk

17

www.naco.co.uk

16

Page 10: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification

Components

Other Control Options

Product Information

Application Example

For larger systems we can offer a full design, manufacture and installation package. Please contact Naco for full details.

Description

MaterialPlastic

Features• Compact design for 1A or 4A actuating current in one group.• Plastic housing, surface mounting type.• Connection of drives with TMS function possible.• Ventilation safety function (deadman’s principle OPEN/CLOSED), can be firmly encoded.• Entry for external control, e.g. timer.• Possibility of connecting rain detector or wind/rain detector without supplementary module.• Possibility of central weather monitoring (central CLOSED) in conjunction with several VCP-0X.• Vent buttons, window drives, weather sensors, indoor air quality sensor (CO2) and room temperature controllers available as accessories.

NATURAL VENT CONTROL PANELMODELS VCP-01 / VCP-04

Technical DataType VCP-01 VCP-04

Power supply 230V AC/50Hz, 30VA 230V AC / 50Hz, 160VA

Output 24V DC, maximum 1A 24V DC, maximum 4A

Class of rating Short-time duty, 20% ED Short-time duty, 20% ED

Protective system IP 50 IP 30

Range of temp –5°C to +60°C –5°C to +40°C

Housing Plastic Plastic

Colour RAL 7035, light grey RAL 7035, light grey

Size W x H x Dmm 139 x 119 x 70 170 x 135 x 85

Natural Vent Control Panel Models VCP-01/ VCP-04 are especially designedfor use in separate rooms or small zones. Due to the large amount of Naco accessories various functions can be added, e.g. automatic weather, room temperature and indoor air quality (CO2) control. It is possible to connect several ventilation control panels in order to enable central switching, e.g. closing in case of wind or rain or time-controlled ventilation.

For situations that do not call for the features of the VCP Control Panel, the ventilation can be controlled by the following two methods.

MOTOR CONTROL: Via the vent open/ close switch

MANUAL CONTROL:Via lever handle

• Compact ventilation control• For separate rooms and small zones• For triggering of 24V DC drives• 1 ventilation group• 1A or 4A actuating current• Single or central switching (OPEN/CLOSED)

Natural Vent Control Panel

Application Example

Components

Important Note: All orders must be addressed to Naco, Ruskin Air Management Limited.

External Controlor

Air Temperature Sensor or

Indoor Air Quality Sensor (CO2)

Models VCP-01/ VCP-04

Rain Detector

Ventilation Drives

Vent Open/CloseSwitch

Models VCP-01/ VCP-04 Temperature Sensor Rain Detector Vent Open/CloseSwitch

For larger systems we can offer a full design, manufacture andinstallation package. Please contact Naco for full details.

Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England.Tel: 01746 761921 Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a ISO 9001 and 14001 registered company

Ruskin Air Management Limited The statements made in this brochure or by ourrepresentatives in consequence of any enquiries arising out ofthis document are given for information purposes only. They arenot intended to have any legal effect and the company is not tobe regarded as bound thereby. The company will only acceptobligations which are expressly negotiated for and agreed andincorporated into a written agreement made with its customers.

Due to a policy of continuous product development thespecification and details contained herein are subject toalteration without prior notice.

Naco Vengen28,WeatherbetaLouvre Windows orNaco NAV unit

Natural Vent Control Panel

Application Example

Components

Important Note: All orders must be addressed to Naco, Ruskin Air Management Limited.

External Controlor

Air Temperature Sensor or

Indoor Air Quality Sensor (CO2)

Models VCP-01/ VCP-04

Rain Detector

Ventilation Drives

Vent Open/CloseSwitch

Models VCP-01/ VCP-04 Temperature Sensor Rain Detector Vent Open/CloseSwitch

For larger systems we can offer a full design, manufacture andinstallation package. Please contact Naco for full details.

Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England.Tel: 01746 761921 Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a ISO 9001 and 14001 registered company

Ruskin Air Management Limited The statements made in this brochure or by ourrepresentatives in consequence of any enquiries arising out ofthis document are given for information purposes only. They arenot intended to have any legal effect and the company is not tobe regarded as bound thereby. The company will only acceptobligations which are expressly negotiated for and agreed andincorporated into a written agreement made with its customers.

Due to a policy of continuous product development thespecification and details contained herein are subject toalteration without prior notice.

Naco Vengen28,WeatherbetaLouvre Windows orNaco NAV unit

Natural Vent Control Panel

Application Example

Components

Important Note: All orders must be addressed to Naco, Ruskin Air Management Limited.

External Controlor

Air Temperature Sensor or

Indoor Air Quality Sensor (CO2)

Models VCP-01/ VCP-04

Rain Detector

Ventilation Drives

Vent Open/CloseSwitch

Models VCP-01/ VCP-04 Temperature Sensor Rain Detector Vent Open/CloseSwitch

For larger systems we can offer a full design, manufacture andinstallation package. Please contact Naco for full details.

Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England.Tel: 01746 761921 Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a ISO 9001 and 14001 registered company

Ruskin Air Management Limited The statements made in this brochure or by ourrepresentatives in consequence of any enquiries arising out ofthis document are given for information purposes only. They arenot intended to have any legal effect and the company is not tobe regarded as bound thereby. The company will only acceptobligations which are expressly negotiated for and agreed andincorporated into a written agreement made with its customers.

Due to a policy of continuous product development thespecification and details contained herein are subject toalteration without prior notice.

Naco Vengen28,WeatherbetaLouvre Windows orNaco NAV unit

Natural Vent Control Panel

Application Example

Components

Important Note: All orders must be addressed to Naco, Ruskin Air Management Limited.

External Controlor

Air Temperature Sensor or

Indoor Air Quality Sensor (CO2)

Models VCP-01/ VCP-04

Rain Detector

Ventilation Drives

Vent Open/CloseSwitch

Models VCP-01/ VCP-04 Temperature Sensor Rain Detector Vent Open/CloseSwitch

For larger systems we can offer a full design, manufacture andinstallation package. Please contact Naco for full details.

Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England.Tel: 01746 761921 Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a ISO 9001 and 14001 registered company

Ruskin Air Management Limited The statements made in this brochure or by ourrepresentatives in consequence of any enquiries arising out ofthis document are given for information purposes only. They arenot intended to have any legal effect and the company is not tobe regarded as bound thereby. The company will only acceptobligations which are expressly negotiated for and agreed andincorporated into a written agreement made with its customers.

Due to a policy of continuous product development thespecification and details contained herein are subject toalteration without prior notice.

Naco Vengen28,WeatherbetaLouvre Windows orNaco NAV unit

Natural Vent Control Panel

Application Example

Components

Important Note: All orders must be addressed to Naco, Ruskin Air Management Limited.

External Controlor

Air Temperature Sensor or

Indoor Air Quality Sensor (CO2)

Models VCP-01/ VCP-04

Rain Detector

Ventilation Drives

Vent Open/CloseSwitch

Models VCP-01/ VCP-04 Temperature Sensor Rain Detector Vent Open/CloseSwitch

For larger systems we can offer a full design, manufacture andinstallation package. Please contact Naco for full details.

Stourbridge Road, Bridgnorth, Shropshire, WV15 5BB England.Tel: 01746 761921 Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a ISO 9001 and 14001 registered company

Ruskin Air Management Limited The statements made in this brochure or by ourrepresentatives in consequence of any enquiries arising out ofthis document are given for information purposes only. They arenot intended to have any legal effect and the company is not tobe regarded as bound thereby. The company will only acceptobligations which are expressly negotiated for and agreed andincorporated into a written agreement made with its customers.

Due to a policy of continuous product development thespecification and details contained herein are subject toalteration without prior notice.

Naco Vengen28,WeatherbetaLouvre Windows orNaco NAV unit

Naco NAV unit Damper

Ventilation Drives

External Controlor

Air Temperature Sensoror

Indoor Air Quality Sensor (CO2)

Vent Open / Close Switch

Rain Detector

Temperature Sensor

Models VCP-01/VCP-04

Control Options

www.naco.co.uk

19

www.naco.co.uk

18

Page 11: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Specification Details

Manufacturing Sizes: The external louvre sizes will determine the dimensions of the damper assembly and optional interior grille.

Finishes: The finish selected for the external louvre will as standard be applied to the damper assembly and optional interior grille unless specified differently.

INTERIOR GRILLE OPTIONS

ModelPG (perforated grille)EC (egg crate grille)WB0 (wide blade grille)

FinishSTD (as for external louvre)(Other, please specify)

PG / STD

EXTERNAL LOUVRE

Blade Typeslimtype, 50, 75, SLH-S

Border TypeA, AC

Glazing Adaptor GA28 (standard)(other options available, please specify)

ScreeningBird Wire Guard (standard) BWGInsect Screen (optional) I.S

FINISHPolyester Powder Coating RAL-Ref No

Satin AnodisedSA

Mill FinishMF

Manufacturing Sizes (W x H)A, AC = nominal openingGA= o/a channel

50 / AC / ---- / I.S / RAL 9010 / 1400 x 600

DAMPER

Model

Damper TypeWA,WI,WI+,WL,WLI

Heating Coil HC

Dynamic Boost FanDBF

Operation1,2, 3,4

Operation HandingLH or RH (viewed from inside)

FinishSTD (as for external louvre)(Other, please specify)

NAV / WA / HC / -/- / 2 / RH / STD

ROOF TERMINAL

ModelNAV

Damper OptionRT (without damper) RTD (with damper)

Damper Type WA,WI

Operation2,3

FINISHPolyester Powder Coating RAL-Ref No

Satin AnodisedSA

Mill FinishMF

Manufacturing Sizes (L x W x H)(to suit builders up stand dimensions)

NAV / RTD / WA / 3 / RAL 9007 / 1400 x 1200 x 950

www.naco.co.uk

21

www.naco.co.uk

20

Page 12: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Natural Air Ventilators

www.naco.co.uk

23

www.naco.co.uk

22

Page 13: Natural Air Ventilators...Louvre and damper frame extruded aluminium grade ENAW 6063T6 to BSEN 755. Frame Construction Thermally broken frame & damper blades. Screw joints as standard

Natural Air Ventilators

Stourbridge Road, BridgnorthShropshire, WV15 5BBTel: 01746 761921Fax: 01746 766450Email: [email protected]: www.naco.co.uk

Ruskin Air Management Limited is a BS EN ISO 9001 registered company.

The statements made in this brochure or byour representatives in consequence of anyenquiries arising out of this document are given forinformation purposes only. They are not intendedto have any legal effect and the company is notto be regarded as bound thereby. The companywill only accept obligations which are expressly negotiated for and agreed and incorporated intoa written agreement made with its customers.

Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice.

Comprehensive and detailed informationis available for all Naco products.Visit our website at www.naco.co.uk

Distributor for Scotland

10 Grange Road, Houstoun Industrial EstateLivingston, West Lothian, EH54 5DETel: +44 (0)1506 438083Fax: +44 (0)1506 433441Email: [email protected]: www.hasl.co.uk