Applications Engineer, NI India
Case Study
Using NI-LabVIEW Real-time and PXI Technology To Automate Gauge-Control In
Cold Rolling Mills
• Alternate Control System Platforms
• Problem Statement
• Formulation of Closed-Loop Control System
• Implementation Using LabVIEW RealTime and NI Hardware
• Leverage Achieved Using NI Equipments
5
Agenda
Control System Platforms• Various Control System Platforms Available
• PLC: Programmed in Ladder Logic (Operation Specific)
• DCS: Collection of various PLC’s and RTU’s (Dedicated Systems)
• Applications using frequently changing control logic may not be efficient on such platforms because development time is more.
• Multiple hardware synchronization not supported
7
• Useful for ferrous and non-ferrous metal industries
• Applications that require Real-Time Monitoring
• Control Systems that require high-precision monitoring and a short response time
To develop a PXI based Gauge monitoring and control system using LabVIEW RT and National Instruments
Data-Acquisition Systems
Gauge-Control In Cold Rolling Mills
• Position
• InitialThickness
• Rotating Speed
• Pressure Applied
Inputs
Sensors Used
Closed Loop Control System
• Process: Hydraulic Pump (to control position)
Implementation through NI Controller running LabVIEW RealTime
Choosing the Right Modules for the PXI System
• NI PXI – 6040E• 500 kS/s (1-Channel), 250 kS/s (Multichannel), 12-Bit, 16-Analog-
Input Multifunction DAQ
• Assimilation of Thickness and Pressure Data
Module for Measuring Speed of the Metal Strip
• NI PXI – 6602 Counter card• 8-channel, 32-bit up/down counter/timer module
• 80 MHz maximum source frequency
• 3 simultaneous high-speed DMA Transfer Capability
Module to Control Servo Valves
• NI PXI – 6711• High-Speed Analog Output -- 12-Bit, 1 MS/s per Channel
• Digital triggering and external clocking
• 2 up/down counter/timers, 24-bit resolution
Final System Setup
Implementation of Control System Using LabVIEW Real-Time Development Environment
• The virtual instrument can be developed using PID Control Toolkit and then targeted to the PXI controller running on LabVIEW Real time.
• Specialized for Time-critical data acquisition and control applications
• Download to a dedicated target for increased reliability.
Benefits of Using LabVIEW RT and NI DAQ Equipments
• The benefits of using LabVIEW and NI DAQ equipments compared to the traditional instruments and PLC :
– The development time for putting the whole system came down by a factor of 1/6.
– Increased flexibility in redesigning the control mechanism as per the requirements of different materials fed to the system.
– Enhanced quality in output because of reduction in response times. In a typical PLC based system the control loop rate is 100 to 500 milliseconds but in NI PXI based system, this is reduced to 10 ms.
– The capability of all the hardware to synchronize on the PXI RTSI bus is an added advantage.
Questions?