narrow diameter implantetadental.com/.../2016/10/nd_narrowdiameter-ing-low.pdfdental implant healing...
TRANSCRIPT
NARROWDIAMETER implant
ND
2
ND
Precision dental solutionsC-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology.
International presence With production and management based in Italy, C-Tech Implant is active in all major world markets and is distributed in over 20 countries.
Scientific research, advanced technology, simplificationC-Tech Implant differentiates itself with attention to research and the application of high technology to its products, all while maintaining a simplicity of insertion and ease of use.
C-Tech Implant incorporates the latest trends in implantology but provides very practical surgical and prosthetic solutions aimed at offering the practitioner and the patient optimal results.
High quality standards kept within reachC-Tech Implant products are made to the highest standards governing the manufacturing and management of European medical and dental components.
Up to date audits and certification assure that these standards are vigilantly maintained.
Training & adviceDental professionals are assisted by the rich knowledge and experience of C-Tech Implant personnel and through C-Tech courses and training sessions.
During these courses the professional is able to learn the latest methods of implant placement and reconstruction.
Mission statementThe goal of C-Tech Implant is to provide the highest level of quality for technologically advanced products at reasonable prices in order to allow the dental practitioner to find solutions for the broadest range of patients.
All of the materials produced by C-TECH follow a validated procedure, which includes surface treatment and packing as well, in conformity with European and international directives EN ISO 13485:2003/AC:207 and 93/42/EEC relative to medical devices.
3
NARROW DIAMETER implant
NARROW DIAMETER implant
Bevelled shoulder- Facilitates bone growth above the shoulder- Long term implant stability - Biological repartition of the forces in cortical bone
Micro grooving- Softens forces to the cortical bone during insertion - Cortical bone maintenance
Grit blasted and acid etched surface topography- Best surface for osseo integration and bone to implant
contact
Aggressive apical design- Ideal for immediate implant placement - Primary stability
Rounded apex- Protection of the sinus floor, nerve canal and other
important anatomical structures during insertion
Implant subcrestal seating- Hinders exposure of the implant through bone
resorption- Ideal for the esthetic zone- Long term esthetic stability
Three different threading profiles - Thread designs adapted to different bone structures
that occur along the depth of the implant - Enhanced surface- Round but cutting apex design
Double lead thread- Insertion rate of 1,5mm per rotation - Primary stability- Increased bone to implant contact- Faster and even insertion while protecting bone
structure
Thread in thread / groove in groove- Increased bone to implant contact
Platform switching- Reduces bone loss- Better representation of the biological width- Long term esthetic stability
Indexing hex- Antirotational security
4
ND
ND-30080.8mm
ND-3022 ND-3024 ND-3026
ND-30099 mm
ND-301111 mm
ND-301313 mm
L
L
L
5.8
L
7.7
D
LC
ND-5052HX
Dental Implant
Healing Abutments
Cover Screw
TIGHTENING: with torque ratchet 10 N=Ncm
Includes screw
ND implant ø3.1
L D item#
0.7
3.8
2 ND-3022
1 4 ND-3024
1.5 6 ND-3026
C Fixture
Prosthetic screw
Material: titanium grade 5
Material: titanium grade 5
Material: titanium grade 5
5
NARROW DIAMETER implant
ND-3040
ND-3041
ND-3042
ND-LAB3042
L
20
D
D
L
L
L
C
L D C
7.5 3.8 2
L D
15 3.1
Open tray impression transfer
Includes screwOpen tray transfer
Impression post screw
Analog
Technician’s working analog
Material: titanium grade 5
Material: titanium grade 5
Material: titanium grade 5
Material: Titanium grade 5 and Acrylic
6
ND
ND-3040/2
ND-3025-1h1
ND-3025-2h2
ND-3025-3h3
ND-1530/1h1
ND-1530h2
ND-1530/3h3
BL-4543
D
L
L D
5 4
D
D1
D2
L
L
C
C
L D C
11.5 3.8 2
L
G
D
C
Impression cap
Complete set
metal transfer
screw plastic cap
Closed tray impression transfer
Titanium abutments
Titanium ø 4 straight abutments
Titanium 15°angled abutments
TIGHTENING: with torque ratchet 20 N=Ncm
Includes screw
Includes screw
L D1 D2 item#
8 3.8 4
1 ND-3025-1
2 ND-3025-2
3 ND-3025-3
C Fixture
L D G item#
6 4
1
15°
ND-1530/1
2 ND-1530
3 ND-1530/3
C Fixture
Material: plastic
Material: titanium grade 5
Material: titanium grade 5
Material: titanium grade 5
7
NARROW DIAMETER implant
ND-2530/1h1
ND-2530/2h2
ND-2530/3h3
ND-6047
ND-5830
ND-TEMP
D1
D2
L
C
L D C
4.65 4.25 2
L D C
7.5 3.8 2
L D1 D2 C
8 3.8 4 1
L
G
D
C
D
D
L
L
C
C
Titanium 25°angled abutments
CEREC® base
Castable abutment
Temporary peek abutment
Includes screw
Includes screw
Includes screw
Includes screw
L D G item#
6 4
1
25°
ND-2530/1
2 ND-2530/2
3 ND-2530/3
C Fixture
Material: PEEK
Material: titanium grade 5
Material: titanium grade 5
Material: Plexiglass
8
ND
1
2
ND
O-Ball attachment system
Intended useRemovable dentures retained by implants in the mandible and maxilla.
Characteristics- The clinical process for the ball attachment is quick and
easy;- Functional;- The O-ring attachment is designed to virtually eliminate
wear on the Ball Abutment and minimize the need for maintenance;
- 3 different gingival heights;- 3 different O-ring resistances offering optimal retention
for every individual situation.
ReliableDual retention for optimal abutment-denture connection. Excellent long-term performance due to wear resistant components.
STEP 1Screw the spherical abutment into the implant using butterfly key MC-3002 or ratchet driver MC-3003S, MC-3003M or MC-3003L.
STEP 2 Rebase the overdenture according to the standard procedure.
9
NARROW DIAMETER implant
ND-5641 ND-5642 ND-5643
x5 x10 x25
D D
L
L D
3.5 4.7
o-ring D
4.4
MC-3002
D L
8.5 7
D
L
D
L
C
x5 x10 x25
DD
L
o-ring D
3.8
TIGHTENING: with torque ratchet 20 N=Ncm
O-Ball abutments
TIGHTENING: with torque ratchet 20 N=Ncm
Complete set includes:O-Ring (Ref. MC-3005) 1 pieceMetal Housing (Ref. MCH-2)O-Ball Abutment (Ref. ND-5641, ND-5642, ND-5643)
Caps soft retention
MCH-1soft
MC-3005BO-RING
5 pieces
MC-3005B/10O-RING
10 pieces
MC-3005B/25O-RING
25 pieces
Butterfly driver
Material: Titanium grade 5
Material: Stainless steel
Material: Titanium grade 5
Material: FDA Buna
Caps medium & hard retention
MCH-2medium
MCH-3hard
MC-3005O-RING
5 pieces
MC-3005/10O-RING
10 pieces
MC-3005/25O-RING
25 pieces
L D item#
3.2 4.2 MCH-2
2.9 4 MCH-3
Material: Titanium grade 5 Material: FDA Buna
L D C item#
3.77 3.8
1 ND-5641
2 ND-5642
3 ND-5643
10
ND
EL-SUR.KIT.01 Surgical Kit
Implant ratchetBL-E7001BL-E7001L
Implant ratchet
ND-E7001 ND-E7001L
Implant latch
BL-E9040
ExtractorBL-6060
Parallel pinsCT-9003
Hex drivers
CT-9025S
Prosth ratchetCT-8051CT-8052
Depth gaugesCT-E9007CT-E9008CT-E9010
Locator drill
CT-2020
EL main drillsCT-1720E / CT-1735E CT-1743E / CT-1751E
EL hand bone drillsEL-1735N / EL-1743N
EL-1751N
Counter drillCT-2035E
Depth stopsCT-STOP07 / CT-STOP08 CT-STOP09 / CT-STOP10
Drill extenderCT-2000
Torque wrenchCT-8010
Main drillND-1726E
11
NARROW DIAMETER implant
L
MC-3007
D
D
L
D L
2.6 15.8
CT-PIN11.9 mm2.5mm
D2
D2
L3
L1
L2
L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5
CT-90031.6 mm2.0mm
L1 L2 L3 D1 D2
23.5 16.5 5.5 1.9 2.5
Instrumentation
O-ball transfer caps Only for O-ball heads implants
D L item#
4.0 7 MC-3013
4.5 6.4 MC-3014
Collared analog
Combined depth paralleling pins
Paralleling pin
Laboratory accessories
Material: Stainless steel
Material: Stainless steel
Material: Titanium grade 5
Material: PUMMC-3013
temporary cap
MC-3014transfer
cap
12
ND
CT-1720ED
L2
L1
L1 L2 D
35.2 17.2 2.1
ND-E7001 ND-E7001L
ND-E9040
CT-2000
L
L
25
CT-2020
D
L2
L1
L1 L2 D
29 15 1.6
L
L
L
11.8
Initial drill
Instrumentation
Material: Stainless steel
Implant ratchet driver
Implant latch
Drill Extender
Locator drill
L item#
9.85 ND-E7001
17.75 ND-E7001L
Material: Stainless steel
Material: Stainless steel
Material: Stainless steel
Material: Stainless steel
13
NARROW DIAMETER implant
D
D
L2
L2
L1
L1
L1 L2 D
26 6 3
L1 L2 D
36.7 17.2 2.6
CT-STOP07Stop L.9
CT-STOP08Stop L.11
CT-STOP09Stop L.13
ND-1730E
ND-1726E
BL-9019
L
26.5
L
CT-8051 CT-8052
L
Stops
Counterbore
Main drills
Material: Stainless steel
Material: Stainless steel
Material: titanium grade 5
Prosthetic latch driver
Torque wrench attachments
L item#
12.5 CT-8051
18.5 CT-8052
Material: Stainless steel
Material: Stainless steel
L D item#
95.2
CT-STOP07
11 CT-STOP0813 CT-STOP09
14
ND
CT-8010
CT-8010PEEK
D
L
CT-9025S CT-9025
L
MC-3002
D L
8.5 7
D
L
Torque Wrench 50Ncm
Finger adapter
Torque Wrench PEEK
CT-E7002for ratchet
drivers
CT-E7003for latch drivers
L D item#
5.8 12.7 CT-E7002
8.61 8 CT-E7003
Instrumentation
Material: Stainless steel
Material: Stainless steel
Material: Stainless steel and PEEK
Hex drivers
L item#
12.5 CT-9025S
18.5 CT-9025
Butterfly driver
Material: Stainless steel
Material: Stainless steel
15
NARROW DIAMETER implant
5 mm
ø3.1
Site preparation
CT-2020Locator Drill
CT-1720E2.0mm Drill
(Outer Ø 2.0mm)
Parallel Pin ND-1726e3.5mm Drill
(Outer Ø 3.1mm)
ND-E9040Implant latch driver
ND-E7001LImplant
ratchet driver
*Depth: Minimum 1mm deeper than length of implant is to allow for subcrestal seating.Note: an additional 0.8 mm must be added to the lenght of the drill due to the leght of the angled cutting tip.
16
ND
2020-12
0416 SIZE: 3.5 x 13 mmREF/REORDER:EL-3513
Rev.05 of 09/11/2015
Made in Italy
The implant packaging is endowed with 3 levels of security; a double vial inside an airtight blister pack. Within the vials the implant is maintained upright by a titanium ring and supported at the implant apex by the titanium cover screw.
Lot number Implant dimension
ISO and CE Certification by TÜV SÜD
HIBC Health Industry Bar Code Format
Implant
Expire date
The device must be use exclusively by the physician
Implant labeling
Implant packaging
Sterilization with gamma rays
Read the instruction sheet
Monouse
17
NARROW DIAMETER implant
1
4
7
2
5
8
3
6
9
We are phasing in a new double vial packaging for the EL, BL and ND implants. This allow the user to pick up the implant directly from the vial with the latch driver. PLEASE NOTE, there is an order to the use of this new implant delivery system.
18
ND
19
NARROW DIAMETER implant
Via Cesare Battisti n. 2 - 40123, Bologna - ITALY - Tel. +39 051 6661817 - Fax +39 051 6667071www.c-tech-implant.com - [email protected]
Follow us on facebook /CTechImplant
Go to www.c-tech-implant.com
REV.
01 /
04-2
016
English version