SuperLine II

Surgical Components

Prosthetic Procedure 1

Prosthetic Procedure 2

Prosthetic Procedure 3

Prosthetic Procedure 4

SuperLine II Characteristics 04 SuperLine II Speci�cation 05 SuperLine II Implant 06 Cover Screw 07 Healing Abutment 08

Dual / Combi Abutment - Abutment Level Impression 10 Combi Abutment 11 Dual Abutment 12 Abutment Level Impression Components 14 Restorative Kit 15

Dual / Custom / Milling / Angled / Direct-Casting / Metal-Casting / Temporary (Peek & Ti) Abutment - Bone Level Impression 16 Bone Level Impression Components 17 Custom Abutment 19

Digital Impression Components 21

Titanium Abutment Blank 20

Milling Abutment 22 Angled Abutment 24 Direct-Casting Abutment 26 Metal-Casting Abutment 26 Ti-Temporary Abutment 27 Plastic Temporary Abutment 27

Screw Abutment - Abutment Level Impression 28 Screw Abutment 29 Angled Screw Abutment 30 Screw Abutment Impression Components 31

Overdenture Procedure - Mini Ball Attachment 34 35

Mini Ball Attachment

36Locator® Abutment

39Locator R-Tx™ Attachment

Contents

SuperLine Product Catalog 5

Implants & Abutments

4 SuperLine II Product Catalog

SuperLine II Characteristics

Improved joint stability & strength for zirconia crown

Tissue contour design

E�cient implant placement in all bone types

· Build a natural emergence pro�le, preserving the patient’s natural gingival contours

· Abutment material : Grade 4 Alloy (Ti 6AL-4V ELI)

Simplicity through sophistication

· One analog for easy restoration process and inventory management· A single connection across all diameters with increased implant wall thickness

· A long cutting edge and new thread design

· Increased abutment screw connection to implant internal threads

Enhancement of implant-abutment connection

· TiN Coating (gold hue) enhances esthetic e�ects on the transculent restorative material

SuperLine II SuperLine

SuperLine II Speci�cations

3.6 4.0 4.5 5.0 6.0 7.0

3.6 4.0 4.5 5.0 5.0 5.8

8 , 10 , 12 , 14

3.33 3.33 3.33 3.33 3.33 3.33

0.38 0.40 0.45 0.50 0.55 0.50

0.03 0.20 0.35 0.60 0.70 1.00

Anterior Anterior Premolar/Molar Molar Molar Molar

Cap Color

Selection Guideline

Fixture(Mount Free)

Platform Diameter(Ø)A

BevelHeight(mm)

C

Total Length(mm)

Abutment Interface(Ø)

Thread Depth(mm)

D

E

F

L: 8, 10, 12, 14

Body Diameter(Ø)B

Yellow Green Blue Red Orange Violet

A

C

FD

B

A

E

SuperLine II Product Catalog 5

0.7 0.7

SuperLine II ImplantUnit: mm, Scale 1.5 : 1

Platform Body L Art. No.

Ø 4.0 Ø 4.0

8

10

12

14

FXS 40 08 C

FXS 40 10 C

FXS 40 12 C

FXS 40 14 C

Ø 3.6 Ø 3.6

8

10

12

14

FXS 36 08 C

FXS 36 10 C

FXS 36 12 C

FXS 36 14 C

Ø 4.5 Ø 4.5

8

10

12

14

FXS 45 08 C

FXS 45 10 C

FXS 45 12 C

FXS 45 14 C

Ø 5.0 Ø 5.0

8

10

12

14

FXS 50 08 C

FXS 50 10 C

FXS 50 12 C

FXS 50 14 C

※ Note: To prevent damage to the Implant driver or the implant itself, do not over-torque during the implant insertion.

08

08

08

08

08

08

10

10

10

10

10

10

12

12

12

12

12

12

14

14

14

140.6 0.6 0.6 0.6

0.35 0.35 0.35 0.35

0.2 0.2 0.2 0.2

0.03 0.03 0.03 0.03

0.7

1.0 1.0 1.0

Ø 6.0 Ø 5.0

8

10

12

FXS 60 08 C

FXS 60 10 C

FXS 60 12 C

Ø 7.0 Ø 5.8

8

10

12

FXS 70 08 C

FXS 70 10 C

FXS 70 12 C

6 SuperLine II Product Catalog

• Cover screw is included in the package

SuperLine II Product Catalog 7

※Hex driver:

For SuperLine FXS series, the cover screw CS36 is used interchangeably for the implant package bundle as well as the seperate purchase. CS36 is compatible throughout all Dentium SuperLine and Implantium series.

Use no more than 5N·cm of torque when screwing Cover Screw to a �xture.

If hex is worn, slot on the head of the product can be used to rotate it.

Cover ScrewUnit: mm, Scale 1.5 : 1• Single use only

Diameter Ø 3.6

Color Diameter Art. No.

Green Ø 3.6 CS 36

Ø 3.6

CS36FXS4510C

• Compatible throughout all Dentium SuperLine & Implantium series

• Single use only• Compatible throughout all Dentium SuperLine & Implantium series

8 SuperLine II Product Catalog

Diameter G/H H Art. No.

Ø 4.0

Ø 4.5

Ø 5.5

Ø 6.5

2.0

2.0

3.0

4.0

2.0

2.0

3.0

4.0

2.0

2.0

3.0

4.0

2.0

2.0

3.0

4.0

2.0

3.5

5.0

7.0

2.0

3.5

5.0

7.0

2.0

3.5

5.0

7.0

2.0

3.5

5.0

7.0

HAB 40 20 20 E

HAB 40 20 35 E

HAB 40 30 50 E

HAB 40 40 70 E

HAB 45 20 20 E

HAB 45 20 35 E

HAB 45 30 50 E

HAB 45 40 70 E

HAB 55 20 20 E

HAB 55 20 35 E

HAB 55 30 50 E

HAB 55 40 70 E

HAB 65 20 20 E

HAB 65 20 35 E

HAB 65 30 50 E

HAB 65 40 70 E

※Hex driver: Use no more than 10N·cm of torque when screwing Healing Abutment to a �xture.

If hex is worn, slot on the head of the product can be used to rotate it.

7.04.0

7.04.0

7.0

7.0

4.0

4.0

5.03.0

5.03.0

5.0

5.0

3.0

3.0

3.52.0

3.52.0

3.5

3.5

2.0

2.0

2.0

2.0

2.0

2.0

Healing AbutmentUnit: mm, Scale 1.5 : 1

G/H 3.0H 5.0

HAB553050EFXS4510C

Diameter Ø 5.5

• Single use only• Tissue contour design, Gold hue• Compatible throughout all Dentium SuperLine & Implantium series

SuperLine II Product Catalog 9

※Hex driver: Use no more than 10N·cm of torque when screwing Healing Abutment to a �xture.If hex is worn, slot on the head of the product can be used to rotate it.

• Single use only• Tissue contour design• Compatible throughout all Dentium SuperLine & Implantium series

Diameter G/H H Art. No.

Ø 7.5

Ø 8.5

Ø 9.5

2.0

3.0

2.0

3.0

2.0

3.0

3.5

5.0

3.5

5.0

3.5

5.0

HAB 75 20 35 E

HAB 75 30 50 E

HAB 85 20 35 E

HAB 85 30 50 E

HAB 95 20 35 E

HAB 95 30 50 E

5.03.0

5.03.0

5.03.5

3.5

3.5

3.02.0

2.0

2.0

Healing AbutmentUnit: mm, Scale 1.5 : 1

10 SuperLine II Product Catalog

Prosthetic Procedure 1Impression Technique and Restoration Selection

Page 17

Dual / Combi Abutment

Closed Tray Technique

Cemented Restoration

Modi�cation

Abutment Level Impression

Burn-out Cylinder

Impression CopingTransfer (Snap on) Ø 4.5 / Ø 5.5 / Ø 6.5

Page 13

Combi AbutmentØ 4.5 / Ø 5.5 / Ø 6.5

Dual AbutmentHex / Non-hex Ø 4.5 / Ø 5.5 / Ø 6.5

Page 14,15

Page 16

Page 16 Page 16

AnalogLong Ø 4.5 / Ø 5.5 / Ø 6.5

BridgeRotationalØ 4.5 / Ø 5.5 / Ø 6.5

SingleNon-rotationalØ 4.5 / Ø 5.5 / Ø 6.5

Page 16

AnalogShort Ø 4.5 / Ø 5.5 / Ø 6.5

SuperLine II Product Catalog 11

※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Combi Abutment with the implant and re-thighten with the same torque after 15 min. to reach the maximum screw tension.

Combi Abutment Unit: mm, Scale 1 : 1

CAB5525FXS4510C

Diameter G/H Type TypeArt. No. Art. No.

Ø 4.5

Ø 5.5

Ø 6.5

1.0

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

Short

Short

Short

Long

Long

Long

CAB 45 10 S

CAB 45 15 S

CAB 45 25 S

CAB 45 35 S

CAB 45 45 S

CAB 45 55 S

CAB 55 15 S

CAB 55 25 S

CAB 55 35 S

CAB 55 45 S

CAB 55 55 S

CAB 65 15 S

CAB 65 25 S

CAB 65 35 S

CAB 65 45 S

CAB 65 55 S

CAB 45 10

CAB 45 15

CAB 45 25

CAB 45 35

CAB 45 45

CAB 45 55

CAB 55 15

CAB 55 25

CAB 55 35

CAB 55 45

CAB 55 55

CAB 65 15

CAB 65 25

CAB 65 35

CAB 65 45

CAB 65 55

• Tissue contour design, Gold hue• Compatible throughout all Dentium SuperLine & Implantium series

G/H 2.5

4.0

1.5

Diameter Ø 5.5

1.04.0

1.05.5

1.54.0

1.5

5.5

1.5

1.5

1.5

1.5

5.5

5.5

4.0

4.0

2.54.0

2.5

5.5

2.5

2.5

2.5

2.5

5.5

5.5

4.0

4.0

3.5

4.0

3.5

5.5

3.5

3.5

3.5

3.5

5.5

5.5

4.0

4.0

4.5

4.0

4.5

5.5

4.5

4.5

4.5

4.5

5.5

5.5

4.0

4.0

4.0

5.5

5.5

5.5

5.5

5.5

4.0

4.0

5.5

5.5

5.5

5.5

Dual Abutment [Hex]Unit: mm, Scale 1.5 : 1

DAB5525HFXS4510C

Diameter G/H Art. No.

Ø 4.5

Ø 5.5

Ø 6.5

1.0

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

DAB 45 10 H

DAB 45 15 H

DAB 45 25 H

DAB 45 35 H

DAB 45 45 H

DAB 45 55 H

DAB 55 15 H

DAB 55 25 H

DAB 55 35 H

DAB 55 45 H

DAB 55 55 H

DAB 65 15 H

DAB 65 25 H

DAB 65 35 H

DAB 65 45 H

DAB 65 55 H

※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Dual Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Tissue contour design, Gold hue• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

G/H 2.5

4.0

1.5

Diameter Ø 5.5

1.0 1.5

1.5

1.5

2.5

2.5

2.5

3.5

3.5

3.5

4.5

4.5

4.5

5.5

5.5

5.5

5.5 5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

12 SuperLine II Product Catalog

SuperLine II Product Catalog 13

Dual Abutment [Non-hex]Unit: mm, Scale 1.5 : 1

DAB5525NFXS4510C

Diameter G/H Art. No.

Ø 4.5

Ø 5.5

Ø 6.5

1.0

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

DAB 45 10 N

DAB 45 15 N

DAB 45 25 N

DAB 45 35 N

DAB 45 45 N

DAB 45 55 N

DAB 55 15 N

DAB 55 25 N

DAB 55 35 N

DAB 55 45 N

DAB 55 55 N

DAB 65 15 N

DAB 65 25 N

DAB 65 35 N

DAB 65 45 N

DAB 65 55 N

※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Dual Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Tissue contour design, Gold hue• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

G/H 2.5

4.0

1.5

Diameter Ø 5.5

1.0 1.5

1.5

1.5

2.5

2.5

2.5

3.5

3.5

3.5

4.5

4.5

4.5

5.5

5.5

5.5

5.5 5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

14 SuperLine II Product Catalog

Abutment Level Impression ComponentsUnit: mm, Scale 1 : 1

Comfort Cap I Snap on

Lab Analog

Burn-out Cylinder

Impression Coping

Type

Type

Type

Diameter

Diameter

Diameter

Diameter

Art. No.

Art. No.

Art. No.

Art. No.

Short

Short

Single

Long

Long

Bridge

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 5.5

Ø 6.5

CCC 45 CS

CCC 55 CS

CCC 65 CS

CAN 45 SL

CAN 55 SL

CAN 65 SL

CBC 45 SL

CBC 55 SL

CBC 65 SL

CIC 45 L

CIC 55 L

CIC 65 L

CCC 45 C

CCC 55 C

CCC 65 C

CAN 45 LL

CAN 55 LL

CAN 65 LL

CBC 45 BL

CBC 55 BL

CBC 65 BL

4.8

4.0

12.8

12.8

5.5

12.0

12.0

6.8

10.4

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

Ø 5.5

Ø 5.5

Ø 5.5

Ø 5.5

Ø 5.5

Ø 6.5

Ø 6.5

Ø 6.5

Ø 6.5

Ø 6.5

Ø 4.5 Ø 5.5 Ø 6.5

• Compatible throughout all Dentium SuperLine & Implantium series

SuperLine II Product Catalog 15

Restorative Kit

XSDAB 45 S

XSDAB 45

XSDAB 55 S

XSDAB 55

XSDAB 65 S

XSDAB 65

CCC 45 CS

CCC 45 C

CCC 55 CS

CCC 55 C

CCC 65 CS

CCC 65 C

CAN 45 SL

CAN 45 LL

CAN 55 SL

CAN 55 LL

CAN 65 SL

CAN 65 LL

CBC 45 SL

CBC 55 SL

CBC 65 SL

CBC 45 BL

CBC 55 BL

CBC 65 BL

CIC 45 L

CIC 55 L

CIC 65 L

Comfort Cap Impression Coping Analog

Lab. Components

Burn-out Cylinder

Combi & Dual Abutment

Art. No

• Compatible throughout all Dentium SuperLine & Implantium series

Prosthetic Procedure 2Impression Technique and Restoration Selection

Modi�cation Modi�cation

Cemented Restoration Screw-Retained Restoration

DualAbutmentHex / Non-hexØ 4.5 / Ø 5.5 / Ø 6.5

Ti-Base CustomAbutmentHex / Non-hexØ 4.5 / Ø 5.5

Page 14,15

Page 24,25

Page 21 Page 28

Page 26,27 Page 29 Page 29

Bone Level Impression

Impression Coping TransferClosed tray technique (Simple case)Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5

Hex Non-hex

MillingAbutmentHex / Non-hexØ 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5 / Ø 7.5

AnalogØ 4.5

AngledAbutmentHex / Non-hex15° / 25° Ø 4.5 / Ø 5.5

Metal-CastingAbutmentHex / Non-hexØ 4.5

Ti-TemporaryAbutmentHex / Non-hexØ 4.5

PlasticTemporaryAbutmentHex / Non-hexØ 4.5 / Ø 5.5 / Ø 6.5

Hex Non-hex

Impression Coping Pick-upOpen tray technique (Complicated case)Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5

Page 19 Page 20

Page 19,20

Dual / Custom / Milling / Angled / Direct-Casting / Metal-Casting / Ti-Temporary / Plastic Temporary Abutment

Page 28

Direct-CastingAbutmentHex / Non-hexØ 4.5

16 SuperLine II Product Catalog

SuperLine II Product Catalog 17

Bone Level Impression ComponentsUnit: mm, Scale 1 : 1

Diameter

Size

Diameter

Type

L

L

Size Art. No.

Art. No.

Art. No.

Ø 4.0

Short

Long

Ø 4.5

Ø 4.5

Ø 5.5

Ø 6.5

Hex

Non-hex

Hex

Non-hex

23.0

27.0

12.0

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Short

Short

Long

Long

Short

Short

Long

Long

Short

Short

Long

Long

Short

Short

Long

Long

DPU 40 11 HE

DPU 40 11 NE

DPU 40 15 HE

DPU 40 15 NE

DPS 11 E

DPS 15 E

DANSE

DPU 45 11 HE

DPU 45 11 NE

DPU 45 15 HE

DPU 45 15 NE

DPU 55 11 HE

DPU 55 11 NE

DPU 55 15 HE

DPU 55 15 NE

DPU 65 11 HE

DPU 65 11 NE

DPU 65 15 HE

DPU 65 15 NE

Impression Coping Pick-up

Impression Coping Pick-Up Screw

Analog

17.0

17.0

17.0

17.0

17.0

17.0

17.0

17.0

23.0

12.0

27.0

21.0

21.0

21.0

21.0

21.0

21.0

21.0

21.0

Hex

Hex

Hex

Hex

Short

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Long

Non-hex

Non-hex

Non-hex

Non-hex

Ø 4.5

• DANSE is a single analog for all Dentium SuperLine II and SuperLine & Implantium implants for platform Ø 4.0 above. • For SuperLine & Implantium Ø 3.6, use DAN34 in the page 25 of ‘SuperLine & Implantium (PN2432-07)’ catalog.

• Impression coping screw is included with Impression coping• Compatible throughout all Dentium SuperLine & Implantium series

※Hex driver: It is recommended to keep the torque level at 5~10N·cm.

• Tissue contour design

18 SuperLine II Product Catalog

Bone Level Impression ComponentsUnit: mm, Scale 1 : 1

Diameter

Size

Diameter

Type

L

L

Size Art. No.

Art. No.

Art. No.

Ø 4.0

Short

Long

Ø 4.5

Ø 4.5

Ø 5.5

Ø 6.5

Hex

Non-hex

Hex

Non-hex

17.0

21.0

12.0

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Short

Short

Long

Long

Short

Short

Long

Long

Short

Short

Long

Long

Short

Short

Long

Long

DTF 40 11 HE

DTF 40 11 NE

DTF 40 15 HE

DTF 40 15 NE

DTS 11 E

DTS 15 E

DANSE

DTF 45 11 HE

DTF 45 11 NE

DTF 45 15 HE

DTF 45 15 NE

DTF 55 11 HE

DTF 55 11 NE

DTF 55 15 HE

DTF 55 15 NE

DTF 65 11 HE

DTF 65 11 NE

DTF 65 15 HE

DTF 65 15 NE

Impression Coping Transfer

Impression Coping Transfer Screw

Analog

11.0

11.0

11.0

11.0

11.0

11.0

11.0

11.0

17.0

12.0

21.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

Hex

Hex

Hex

Hex

Short

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Long

Non-hex

Non-hex

Non-hex

Non-hex

Ø 4.5

• DANSE is a single analog for all Dentium SuperLine II and SuperLine & Implantium implants for platform Ø 4.0 above. • For SuperLine & Implantium Ø 3.6, use DAN34 in the page 25 of ‘SuperLine & Implantium (PN2432-07)’ catalog.

• Impression coping screw is included with Impression coping• Compatible throughout all Dentium SuperLine & Implantium series

※Hex driver: It is recommended to keep the torque level at 5~10N·cm.

• Tissue contour design

SuperLine II Product Catalog 19

Top view

Ø 5.5

Ø 4.5

Ti-Base Custom AbutmentUnit: mm, Scale 1.5 : 1

G/H 1.0

5.5

CDAB5510HEFXS4510C

Diameter Ø 5.5

Hex

Hex

Non-hex

Non-hex

Hex

Hex

Non-hex

Non-hex

1.5 1.50.5 0.5

1.0 1.0 2.0 2.0

Diameter TypeG/H Art. No.

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

0.5

0.5

1.5

1.5

1.0

1.0

2.0

2.0

CDAB 45 05 HE

CDAB 45 05 NE

CDAB 45 15 HE

CDAB 45 15 NE

CDAB 55 10 HE

CDAB 55 10 NE

CDAB 55 20 HE

CDAB 55 20 NE

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Custom Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

Unit: mm, Scale 1 : 0.8

Diameter Type Art. No.

Ø 10.0 Hex

Non-hex

CMAB 10 HAL

CMAB 10 NA

Diameter Type Art. No.

Ø 14.0 Hex

Non-hex

CMAB 14 HAL

CMAB 14 NA

Diameter Type Art. No.

Ø 15.0 Hex

Non-hex

CMAB 15 HAL

CMAB 15 NA

Titanium Abutment Blanks

Ø 14.0

Ø 15.0

Ø 14.0

Ø 15.0

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Ø 10.0 Ø 10.0

Ø 2.3

Ø2.0

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

20 SuperLine II Product Catalog

SuperLine II Product Catalog 21

Unit: mm, Scale 1.5 : 1

Digital Impression Components

Scanning Jig

Scanning Jig

Digital Analog

for Titanium Abutment Blanks

for Screw Abutment

ShortLong

3.5

10.0

12.0 12.0

Hex Non-hex

Ø 4.5

Ø 4.5, 5.5 Ø 4.5, 5.5

12.0

4.5

1.8

2.3

2.0

2.3

DAN 38D

3.5

5.5

Ø 4.5

Diameter Type Art. No.

Ø 4.5, 5.5Hex

Non-hex

Single

Bridge

SCJ E4555

SCJ E4555N

Diameter Type Art. No.

Ø 4.5Hex

Hex

Single

Bridge

SCJ I4565

SCJ I4565S

• Ti-retaining screw (SRS18) included

• Abutment screw (ASC2045) included

• DAN38D is for all diameters for SuperLine II and SuperLine & Implantium implants except for SuperLine & Implantium (Platform: Ø3.6 / Body: Ø3.4) implant. • For SuperLine & Implantium (Platform: Ø3.6 / Body: Ø3.4) implant, use DAN34D in page 29 of ‘SuperLine & Implantium (PN2432-07)’ catalog.

• Compatible throughout all Dentium SuperLine & Implantium series

Diameter L Art. No.

Ø 4.5 12.0 DAN 38D

22 SuperLine II Product Catalog

Milling AbutmentUnit: mm, Scale 1.5 : 1

MAB55157HFXS4510C

Diameter TypeG/H Art. No.

Ø 4.0

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

1.0

1.0

1.5

1.5

1.5

1.5

2.5

2.5

MAB 40 105 H

MAB 40 105 N

MAB 45 156 H

MAB 45 156 N

MAB 55 157 H

MAB 55 157 N

MAB 55 257 H

MAB 55 257 N

Diameter TypeG/H Art. No.

Diameter TypeG/H Art. No.

※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Milling Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hue

G/H 1.5

12.0

Diameter Ø 5.5

Hex

Hex

HexHex

Non-hex

Non-hex

Non-hexNon-hex

1.0

1.5

2.51.5

1.5

2.51.5

1.0

SuperLine II Product Catalog 23

Milling AbutmentUnit: mm, Scale 1.5 : 1

Diameter

Diameter

Type

Type

G/H

G/H

Art. No.

Art. No.

Ø 6.5

Ø 7.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

1.5

1.5

2.5

2.5

3.5

3.5

2.5

2.5

3.5

3.5

MAB 65 158 H

MAB 65 158 N

MAB 65 258 H

MAB 65 258 N

MAB 65 358 H

MAB 65 358 N

MAB 75 259 H

MAB 75 259 N

MAB 75 359 H

MAB 75 359 N

• Abutment screw is included

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Milling Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hue

Hex

Hex

Hex

Hex Non-hex

Non-hex

Non-hex

Non-hex

2.5

2.5

3.5

1.5 2.5

2.5

3.5

Hex Non-hex

3.5 3.5

1.5

Angled Abutment [15°]Unit: mm, Scale 1.5 : 1

Diameter

Diameter

Type

Type

G/H

G/H

Art. No.

Art. No.

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

1.5

1.5

2.5

2.5

3.5

3.5

1.5

1.5

2.5

2.5

3.5

3.5

AAB 15 45 15 H

AAB 15 45 15 N

AAB 15 45 25 H

AAB 15 45 25 N

AAB 15 45 35 H

AAB 15 45 35 N

AAB 15 55 15 H

AAB 15 55 15 N

AAB 15 55 25 H

AAB 15 55 25 N

AAB 15 55 35 H

AAB 15 55 35 N

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

AAB155525HFXS4510C

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hue

G/H 2.5

Diameter Ø 4.5

15°

Hex

Hex

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

1.5

1.5

2.5

2.5

3.5

3.5

1.5

1.5

2.5

2.5

3.5

3.5

24 SuperLine II Product Catalog

SuperLine II Product Catalog 25

Angled Abutment [25°]Unit: mm, Scale 1.5 : 1

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

AAB255525HFXS4510C

Diameter

Diameter

Type

Type

G/H

G/H

Art. N .

Art. No.

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

1.5

1.5

2.5

2.5

3.5

3.5

1.5

1.5

2.5

2.5

3.5

3.5

AAB 25 45 15 H

AAB 25 45 15 N

AAB 25 45 25 H

AAB 25 45 25 N

AAB 25 45 35 H

AAB 25 45 35 N

AAB 25 55 15 H

AAB 25 55 15 N

AAB 25 55 25 H

AAB 25 55 25 N

AAB 25 55 35 H

AAB 25 55 35 N

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hue

Hex

Hex

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

1.5

1.5

2.5

2.5

3.5

3.5

1.5

1.5

2.5

2.5

3.5

3.5

G/H 2.5

25°

Diameter Ø 4.5

26 SuperLine II Product Catalog

Direct-Casting Abutment

Metal-Casting Abutment

Unit: mm, Scale 1.5 : 1

Unit: mm, Scale 1.5 : 1

• Abutment screw is included

• Abutment screw is included

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Direct/Metal-Casting Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

4.5

Diameter Ø 4.5

G/HDiameter Type Art. No.

1.0Ø 4.5Hex

Non-hex

RAB 45 CLH

RAB 45 CLN

RAB45CLHFXS4510C Hex

1.0

Co-Cr

Non-hex

1.0

G/H 1.0

12.0

• Compatible throughout all Dentium SuperLine & Implantium series

• Compatible throughout all Dentium SuperLine & Implantium series

4.5

Diameter Ø 4.5

G/HDiameter Type Art. No.

1.0Ø 4.5Hex

Non-hex

RAB 45 GH

RAB 45 GN

RAB45GHFXS4510C Hex

1.0

Non-hex

Gold

1.0

G/H 1.0

12.0

SuperLine II Product Catalog 27

Hex

1.0

Non-hex Hex

3.0 3.0

Non-hex

1.0

10.0

Ti-Temporary Abutment

Plastic Temporary Abutment

Unit: mm, Scale 1.5 : 1

Unit: mm, Scale 1.5 : 1

• Abutment screw is included.

Diameter Ø 4.5

Diameter Ø 4.5

G/H

G/H

Diameter

Diameter

Type

Type

Art. No.

Art. No.

1.0

3.0

2.0

2.0

2.0

Ø 4.5

Ø 4.5

Ø 5.5

Ø 6.5

Hex

Non-hex

Hex

Non-hex

Hex Non-hex

Hex Non-hex

Hex Non-hex

TAB 4510 HG

TAB 4510 NG

TAB 4530 HG

TAB 4530 NG

RAB 45 20 PHLRAB 45 20 PNL

RAB 55 20 PHL RAB 55 20 PNL

RAB 65 20 PHL RAB 65 20 PNL

TAB45HGFXS4510C

RAB4520PHLFXS4510C

Hex

Hex

Hex Non-hex

Non-hex

Non-hex

G/H 1.0

G/H 2.0

2.0 2.0 2.0

2.02.0

2.0

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Ti/Plastic Temporary Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Compatible throughout all Dentium SuperLine & Implantium series

• Abutment screw is included.• Compatible throughout all Dentium SuperLine & Implantium series

Screw Abutment

Open tray technique Closed tray technique

Screw-Retained Restoration

Abutment Level Impression

Impression Technique and Restoration Selection

Burn-out Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5

Polishing ProtectorØ 4.5 / Ø 5.5

Ti-Retaining Screw

Gold Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5

Metal Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5

Ti Temporary Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5

Ti Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5

Temporary Restoration

Page 35

Page 33

Page 34

Page 35 Page 35 Page 35Page 34

Page 31

Page 34

Page 33 Page 33

Page 32

Screw AbutmentØ 4.5 / Ø 5.5

AnalogØ 4.5 / Ø 5.5

Angled Screw AbutmentHex / Non-hex 20° Ø 4.5 / Ø 5.5

Prosthetic Procedure 3

Impression Coping Pick-up Ø 4.5 / Ø 5.5 / Ø 6.5

Impression Coping TransferØ 4.5 / Ø 5.5 / Ø 6.5

28 SuperLine II Product Catalog

SuperLine II Product Catalog 29

Screw AbutmentUnit: mm, Scale 1.5 : 1

DeliveryHolder

SAB5525FXS4510C

Diameter

Diameter

G/H

G/H

Art. No.

Art. No.

Ø 4.5

Ø 5.5

1.0

1.5

2.5

3.5

4.5

5.5

1.5

2.5

3.5

4.5

5.5

SAB 45 10

SAB 45 15

SAB 45 25

SAB 45 35

SAB 45 45

SAB 45 55

SAB 55 15

SAB 55 25

SAB 55 35

SAB 55 45

SAB 55 55

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Screw Abutment with the implant and re-tighten it after 15 min.

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hueG/H 2.5

Diameter Ø 5.5

1.0 1.5

1.5

2.5

2.5

3.5

3.5

4.5

4.5

5.5

5.5

30 SuperLine II Product Catalog

Angled Screw AbutmentUnit: mm, Scale 1.5 : 1

ASA5520HFXS4510C

※15° and 30° angles are also available with Titanium G4, strait G/H design. Please refer to SuperLine & Implantium Product Catalog P38.

7.3

Ø 2.0

Diameter

Diameter

Type

Type

G/H

G/H

Art. No.

Art. No.

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

1.0

1.0

2.0

2.0

3.0

3.0

1.0

1.0

2.0

2.0

3.0

3.0

ASA 45 10 H

ASA 45 10 N

ASA 45 20 H

ASA 45 20 N

ASA 45 30 H

ASA 45 30 N

ASA 55 10 H

ASA 55 10 N

ASA 55 20 H

ASA 55 20 N

ASA 55 30 H

ASA 55 30 N

Diameter L Art. No.

Ø 2.3 7.3 ASASC 20 23

Angled Screw Abutment ScrewØ 2.3

DeliveryHolder

ASAH

Ti-Delivery Holder

15.8

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Screw Abutment with the implant and re-tighten it after 15 min.

• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series

• Tissue contour design, Gold hueG/H 2.0

Diameter Ø 5.520°

3.0 3.0

1.02.54

2.88

4.88

2.88 3.88 3.88

4.54 4.54

2.54 3.54 3.54

1.0

1.0

1.0

2.0

2.0

3.0 3.0

2.0

2.0

Hex

Hex

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

Non-hex

4.88

SuperLine II Product Catalog 31

SuperLine II Product Catalog 7

Screw Abutment Impression ComponentsUnit: mm, Scale 1.5 : 1

15.0

9.0

Diameter

Diameter

Type

Type

Art. No.

Art. No.

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

SPU 45 SL

SPU 45 BL

SPU 55 SL

SPU 55 BL

STF 45 SL

STF 45 BL

STF 55 SL

STF 55 BL

Type L Art. No.

Pick-up

Transfer

15.0

9.0

SPS 09

STS 09

Impression Coping Screw

Hex

Hex

Hex

Hex

Non-hex

Non-hex

Non-hex

Non-hex

Ø 4.5

Ø 4.5

Ø 5.5

Ø 5.5

Ø 4.5

Ø 4.5

Ø 5.5

Ø 5.5

Impression Coping Pick-up

Impression Coping Transfer

• Compatible throughout all Dentium SuperLine & Implantium series

※Hex driver: It is recommended to keep the torque level at 5~10N·cm.

Screw Abutment ComponentsUnit: mm, Scale 1.5 : 1

Diameter

Diameter

Diameter

Diameter

L

L

L

L

Art. No.

Art. No.

Art. No.

Art. No.

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

5.0

5.0

12.0

4.71

SCC 45 T

SCC 55 T

SCC 45 L

SCC 55 L

SAN 45 L

SAN 55 L

SPP 45 L

SPP 55 L

Comfort Cap

Comfort Cap

Analog

Polishing Protector

5.0

5.0

12.0

5.5 5.5

5.5 5.5

0.8 0.8

0.8 0.8

5.0

5.0

12.0

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5 Ø 4.5

Ø 5.5 Ø 5.5

Ø 4.5

Ø 5.5

Ø 5.5

Ø 5.5

Ø 5.5

5.0

4.71 4.71

Ø 1.8

Diameter L Art. No.

Ø 2.3 5.0 SRS 18 T

Ti-Retaining Screw Ø 2.3

Diameter Type Art. No.

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

STA 45 S

STA 45 B

STA 55 S

STA 55 B

Ti-Cylinder

Hex

Hex

Non-hex

Non-hex

• Compatible throughout all Dentium SuperLine & Implantium series

※Hex driver: It is recommended to keep the torque level at 5~10N·cm.

32 SuperLine II Product Catalog

SuperLine II Product Catalog 33

Screw Abutment ComponentsUnit: mm, Scale 1.5 : 1

8.7

12.0

12.0

12.0

8.7

12.0

12.0

12.0

3.3 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

Ø 5.5

Ø 5.5

Ø 5.5

Ø 5.5

Diameter

Diameter

Diameter

Diameter

Type

Type

Type

Type

Art. No.

Art. No.

Art. No.

Art. No.

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Ø 4.5

Ø 5.5

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

Hex

Non-hex

STC 45 SG

STC 45 BG

STC 55 SG

STC 55 BG

SGC 45 SL

SGC 45 BL

SGC 55 SL

SGC 55 BL

SGC 45 CSL

SGC 45 CBL

SGC 55 CSL

SGC 55 CBL

SBC 45 SL

SBC 45 BL

SBC 55 SL

SBC 55 BL

Ti-Temporary Cylinder

Gold Cylinder

Metal Cylinder I Co-Cr

Burn-out Cylinder

• Compatible throughout all Dentium SuperLine & Implantium series

※Hex driver: It is recommended to keep the torque level at 5~10N·cm.

Impression Technique and Restoration Type

Overdenture Procedure (Laboratory)

Prosthetic Procedure 4

Socket Spacer

Ø 4.05 / Ø 4.85

Mini Ball Female Socket / O-ring

Ø 4.05 / Ø 4.85

Mini Ball / Locator® Abutment / Locator™ R-Tx

Mini Ball Impression Coping

Mini Ball Abutment

Ø 3.5

Page 37

Locator®Impression Coping

Page 38

Page 37

Locator®Abutment

Ø 3.85

Page 38

Mini Ball Analog

Ø 3.5

Page 37

Locator® Spacer& DentureCap Assembly

Page 39

Page 37

Locator StandardReplacement Males

Locator ExtendedReplacement Males

Page 39

Page 37

Locator® Analog

Ø 4.0 / Ø 5.0

Page 38

Locator™ R-TxImpression Coping

Page 41

Locator™ R-TxAbutment

Ø 3.85

Page 41

Locator™ R-Tx Spacer& DentureCap Assembly

Page 42

Locator™ R-Tx StandardRetention Inserts

Locator™ R-Tx Low Retention Limited Range Inserts

Page 42

Locator™ R-TxAnalog Ø 4.0 / Ø 5.0

Page 41

Abutment Level Impression

34 SuperLine II Product Catalog

SuperLine II Product Catalog 35

(BFS 3) (BNO 1) (BFS 2) (BNO 2)

Ø 4.05 Ø 4.85

2.9 3.3

Mini Ball AttachmentUnit: mm, Scale 1.5 : 1

G/H 2.0

2.9

BPF3 BAB352018 FXS4510C

Diameter Ø 4.05

4.2

1.0 2.0 3.0 4.0 5.0

Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8

Diameter

Diameter

Diameter

L Art. No.

Art. No.

Art. No.

Ø 3.4

Ø 3.5

Ø 4.05

Ø 4.85

4.2 GICA

BANL

GBIC 3 L

GBIC 2 L

Diameter Retention Force Art. No.

Ø 4.05

Ø 4.85

300~500 gf, 0.66~1.10 lbf

500~700 gf, 1.10~1.54 lbf

BPF 3

BPF 2

Mini Ball Impression Coping

Mini Ball Analog

Socket Spacer

Female Socket

Ø 3.4

Ø 4.05 Ø 4.85

Ø 3.3 Ø 3.5 Ø 3.5 Ø 3.5 Ø 3.5 Ø 3.5

Diameter G/H Art. No.

Ø 3.3

Ø 3.5

Ø 3.5

Ø 3.5

Ø 3.5

Ø 3.5

0

1.0

2.0

3.0

4.0

5.0

BAB 35 00 18

BAB 35 10 18

BAB 35 20 18

BAB 35 30 18

BAB 35 40 18

BAB 35 50 18

Mini Ball Abutment

Ø 1.8Ø 3.5

0.5

Diameter H Art. No.

Ø 6.5 0.5 BOS

Block Out SpacerØ 6.5

Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Mini Ball Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Compatible throughout all Dentium SuperLine & Implantium series

Locator® Abutment

0.501.50 2.0 3.0 4.0

5.0

Qty Art. No.

4 / pack 08505

Locator® Impression Coping

Locator® Analog

4 / pack

Ø 3.85 Ø 3.85 Ø 3.85 Ø 3.85 Ø 3.85Diameter Cu� Height Art. No.

Ø 3.85

0.5

2.0

3.0

4.0

5.0

08656

08657

08658

08659

08660

Locator® Abutment

If using a Ø3.6mm platform / Ø3.4mm body SuperLine I & Implantium (not applicable for SuperLine II), the abutmentis 0.5mm higher compared to that with larger diameters.Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Locator® Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

• Compatible throughout all Dentium SuperLine & Implantium series

Diameter Art. No.

Ø 4.0

Ø 5.0

08530

08516

Ø 4.0 Ø 5.0

1.501.50

1.501.50

Qty

C/H 2.0

08657FXS4510C

Locator®Processing Package

Abutment Diameter Ø 3.85

36 SuperLine II Product Catalog

SuperLine II Product Catalog 37

Locator® Abutment

Qty Art. No.

4 / packProcessing SpacerBlock-out Spacer

0856908514

Locator® Spacer

Locator® Denture Cap Assembly

ColorRentention ForcePivot Art. No.

BlueExtra Light(680 gf, 1.5 lbs)

Light(1361 gf, 3.0 lbs)

Regular(1361 gf, 3.0 lbs)

Pink

Clear

08529

08527

08524

Locator® Standard Replacement Males (4 / pack)

Qty Type Art. No.

2 / pack

Standard (Convergence/Divergence ± 10° )

Extended(Convergence/Divergence ± 20°)

08519-2

08540-2

Locator® Processing Package

Standard Extended

Block-out Spacer Processing Spacer

Blue Pink Clear

Denture CapAssembly

Black ProcessingMale

ColorRentention Force Art. No.

GreyZero(0 gf, 0 lbf)

Red

Orange

Green

08558

08548

08915

08547

Locator® Extended Replacement Males (4 / pack)

Grey Red Orange Green

• Compatible throughout all Dentium SuperLine & Implantium series

Extra Light(454 gf, 1.0 lbf)

Light(907 gf, 2.0 lbf)

Regular(1814 gf, 4.0 lbf)

±10°

±20°

Pivot

Standard replacement: Convergence/Divergence ± 10°

Extended replacement: Convergence/Divergence ± 20°

Type

Qty Art. No.

Denture Cap Assembly4 / pack

08510-4Black Processing Male 08515

Type

38 SuperLine II Product Catalog

Tools

Type Qty Art. No.

Locator® Parallel Post

Locator® Core Tool

Dentium Torque Wrench

Locator®Angle Measurement Guide

08393

Locator® Core Tool Tip 08397

Locator® Abutment Holder Sleeve 08394

08517

XNTW

09530

Locator® Abutment• Compatible throughout all Dentium SuperLine & Implantium series

Drivers

Locator®Torque Wrench Driver

15

21

08926

0892715.0 21.0

LengthType Art. No.

Dentium Torque WrenchLocator® Angle Measurement Guide Locator® Parallel Post

Locator® Core Tool

Core Tool Tip:Removal of

replacement malesSeating of

replacement malesAbutment

driverAbutment

holder sleeve

4 / pack

1

1

1

1

1

SuperLine II Product Catalog 39

R-Tx™ Abutment

Qty Art. No.

4 / pack 30017-01

R-Tx™ Impression Coping

R-Tx™ Analog

R-Tx™ Abutment

Ø 4.0

Ø 5.0

30015-01

30016-01

Ø 4.0 Ø 5.0

Diameter Cu� Height Art. No.

Ø 3.85

1.0

2.0

3.0

4.0

5.06.0

32801-01-DE-SB

32801-02-DE-SB

32801-03-DE-SB

32801-04-DE-SB

32801-05-DE-SB32801-06-DE-SB

If using a Ø3.6mm platform / Ø3.4mm body SuperLine I & Implantium (not applicable for SuperLine II), the abutmentis 0.5mm higher compared to that with larger diameters.Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Locator® Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.

4 / pack

Diameter Art. No.Qty

• Compatible throughout all Dentium SuperLine & Implantium series

3.0

Ø 3.85

1.50

Ø 3.85

4.0

1.50

Ø 3.85

5.0

1.50

Ø 3.85

6.0

1.50

C/H 3.0

32801-03-DE-SB R-Tx All-in-onePackage

FXS4510C

Abutment Diameter Ø 3.85

1.01.50

Ø 3.85

2.0

Ø 3.85

1.50

Qty Art. No.

2 / pack

R-Tx™ Mixed Retention Limited Range Processing Package

30030-01

ColorRentention Force Art. No.

Aqua

Magenta

Gold

Standard Retention Inserts (4 / pack)

Spacer

Aqua Magenta Gold

ColorPivot

Pivot

Rentention Force Art. No.

Grey

Blue

PinkClear

30001-01

30002-0130003-01

30004-01

30027-01

30028-01

30029-01

Low Retention Limited Range Inserts (4 / pack)

Grey Blue Pink Clear

R-Tx™ Abutment• Compatible throughout all Dentium SuperLine & Implantium series

±30°

±30°

Zero

Low

Medium

High

Zero

Low

Medium

Standard Retention: Convergence/Divergence ± 30°

Low Retention: Convergence/Divergence ± 30°

30027-01 30028-01 30029-01

Qty Art. No.

4 / packSpacer 30018-01

R-Tx™ Spacer

R-Tx™ Denture Cap Assembly

Denture CapAssembly

Black ProcessingMale

Type

Qty Art. No.

Denture Cap Assembly4 / pack

30013-01Black Processing Male 30012-01

Type

40 SuperLine II Product Catalog

SuperLine II Product Catalog 41

Tools

Drivers

Type Art. No.

Retention Insert Tool (Dual Sided)

Dentium Torque Wrench

30021-01

XNTW

Hex Driver Manual [w/wheel]

Hex Driver Hand-piece

Hex Driver Ratchet

26

30

25

21

25

XHD26T

XHD30T

XHD25H

XHD21W

XHD25W

27 XHD27W

LengthType Art. No.

Retention Insert Tool (Dual Sided)Dentium Torque Wrench

R-Tx™ Abutment• Compatible throughout all Dentium SuperLine & Implantium series

21 25 2726 30 25

19 Years of Clinical Evidence

19 years

SuperLine IIProduct Catalog

US OFFICE6731 Katella Ave., Cypress, CA 90630 Tel: 1-877-304-6752 Fax: 1-714-226-0019

www.dentiumusa.com / [email protected]

Manufacturing

Website / E-mail6731 Katella Ave., Cypress, CA 90630 Tel: 1-714-226-0229 Fax: 1-714-226-1889

PN2432-08

Speci�cations are subject to change without any notice.