implants & abutments
TRANSCRIPT
SuperLine II
Surgical Components
Prosthetic Procedure 1
Prosthetic Procedure 2
Prosthetic Procedure 3
Prosthetic Procedure 4
SuperLine II Characteristics 04 SuperLine II Speci�cation 05 SuperLine II Implant 06 Cover Screw 07 Healing Abutment 08
Dual / Combi Abutment - Abutment Level Impression 10 Combi Abutment 11 Dual Abutment 12 Abutment Level Impression Components 14 Restorative Kit 15
Dual / Custom / Milling / Angled / Direct-Casting / Metal-Casting / Temporary (Peek & Ti) Abutment - Bone Level Impression 16 Bone Level Impression Components 17 Custom Abutment 19
Digital Impression Components 21
Titanium Abutment Blank 20
Milling Abutment 22 Angled Abutment 24 Direct-Casting Abutment 26 Metal-Casting Abutment 26 Ti-Temporary Abutment 27 Plastic Temporary Abutment 27
Screw Abutment - Abutment Level Impression 28 Screw Abutment 29 Angled Screw Abutment 30 Screw Abutment Impression Components 31
Overdenture Procedure - Mini Ball Attachment 34 35
Mini Ball Attachment
36Locator® Abutment
39Locator R-Tx™ Attachment
Contents
4 SuperLine II Product Catalog
SuperLine II Characteristics
Improved joint stability & strength for zirconia crown
Tissue contour design
E�cient implant placement in all bone types
· Build a natural emergence pro�le, preserving the patient’s natural gingival contours
· Abutment material : Grade 4 Alloy (Ti 6AL-4V ELI)
Simplicity through sophistication
· One analog for easy restoration process and inventory management· A single connection across all diameters with increased implant wall thickness
· A long cutting edge and new thread design
· Increased abutment screw connection to implant internal threads
Enhancement of implant-abutment connection
· TiN Coating (gold hue) enhances esthetic e�ects on the transculent restorative material
SuperLine II SuperLine
SuperLine II Speci�cations
3.6 4.0 4.5 5.0 6.0 7.0
3.6 4.0 4.5 5.0 5.0 5.8
8 , 10 , 12 , 14
3.33 3.33 3.33 3.33 3.33 3.33
0.38 0.40 0.45 0.50 0.55 0.50
0.03 0.20 0.35 0.60 0.70 1.00
Anterior Anterior Premolar/Molar Molar Molar Molar
Cap Color
Selection Guideline
Fixture(Mount Free)
Platform Diameter(Ø)A
BevelHeight(mm)
C
Total Length(mm)
Abutment Interface(Ø)
Thread Depth(mm)
D
E
F
L: 8, 10, 12, 14
Body Diameter(Ø)B
Yellow Green Blue Red Orange Violet
A
C
FD
B
A
E
SuperLine II Product Catalog 5
0.7 0.7
SuperLine II ImplantUnit: mm, Scale 1.5 : 1
Platform Body L Art. No.
Ø 4.0 Ø 4.0
8
10
12
14
FXS 40 08 C
FXS 40 10 C
FXS 40 12 C
FXS 40 14 C
Ø 3.6 Ø 3.6
8
10
12
14
FXS 36 08 C
FXS 36 10 C
FXS 36 12 C
FXS 36 14 C
Ø 4.5 Ø 4.5
8
10
12
14
FXS 45 08 C
FXS 45 10 C
FXS 45 12 C
FXS 45 14 C
Ø 5.0 Ø 5.0
8
10
12
14
FXS 50 08 C
FXS 50 10 C
FXS 50 12 C
FXS 50 14 C
※ Note: To prevent damage to the Implant driver or the implant itself, do not over-torque during the implant insertion.
08
08
08
08
08
08
10
10
10
10
10
10
12
12
12
12
12
12
14
14
14
140.6 0.6 0.6 0.6
0.35 0.35 0.35 0.35
0.2 0.2 0.2 0.2
0.03 0.03 0.03 0.03
0.7
1.0 1.0 1.0
Ø 6.0 Ø 5.0
8
10
12
FXS 60 08 C
FXS 60 10 C
FXS 60 12 C
Ø 7.0 Ø 5.8
8
10
12
FXS 70 08 C
FXS 70 10 C
FXS 70 12 C
6 SuperLine II Product Catalog
• Cover screw is included in the package
SuperLine II Product Catalog 7
※Hex driver:
For SuperLine FXS series, the cover screw CS36 is used interchangeably for the implant package bundle as well as the seperate purchase. CS36 is compatible throughout all Dentium SuperLine and Implantium series.
Use no more than 5N·cm of torque when screwing Cover Screw to a �xture.
If hex is worn, slot on the head of the product can be used to rotate it.
※
Cover ScrewUnit: mm, Scale 1.5 : 1• Single use only
Diameter Ø 3.6
Color Diameter Art. No.
Green Ø 3.6 CS 36
Ø 3.6
CS36FXS4510C
• Compatible throughout all Dentium SuperLine & Implantium series
• Single use only• Compatible throughout all Dentium SuperLine & Implantium series
8 SuperLine II Product Catalog
Diameter G/H H Art. No.
Ø 4.0
Ø 4.5
Ø 5.5
Ø 6.5
2.0
2.0
3.0
4.0
2.0
2.0
3.0
4.0
2.0
2.0
3.0
4.0
2.0
2.0
3.0
4.0
2.0
3.5
5.0
7.0
2.0
3.5
5.0
7.0
2.0
3.5
5.0
7.0
2.0
3.5
5.0
7.0
HAB 40 20 20 E
HAB 40 20 35 E
HAB 40 30 50 E
HAB 40 40 70 E
HAB 45 20 20 E
HAB 45 20 35 E
HAB 45 30 50 E
HAB 45 40 70 E
HAB 55 20 20 E
HAB 55 20 35 E
HAB 55 30 50 E
HAB 55 40 70 E
HAB 65 20 20 E
HAB 65 20 35 E
HAB 65 30 50 E
HAB 65 40 70 E
※Hex driver: Use no more than 10N·cm of torque when screwing Healing Abutment to a �xture.
If hex is worn, slot on the head of the product can be used to rotate it.
7.04.0
7.04.0
7.0
7.0
4.0
4.0
5.03.0
5.03.0
5.0
5.0
3.0
3.0
3.52.0
3.52.0
3.5
3.5
2.0
2.0
2.0
2.0
2.0
2.0
Healing AbutmentUnit: mm, Scale 1.5 : 1
G/H 3.0H 5.0
HAB553050EFXS4510C
Diameter Ø 5.5
• Single use only• Tissue contour design, Gold hue• Compatible throughout all Dentium SuperLine & Implantium series
SuperLine II Product Catalog 9
※Hex driver: Use no more than 10N·cm of torque when screwing Healing Abutment to a �xture.If hex is worn, slot on the head of the product can be used to rotate it.
• Single use only• Tissue contour design• Compatible throughout all Dentium SuperLine & Implantium series
Diameter G/H H Art. No.
Ø 7.5
Ø 8.5
Ø 9.5
2.0
3.0
2.0
3.0
2.0
3.0
3.5
5.0
3.5
5.0
3.5
5.0
HAB 75 20 35 E
HAB 75 30 50 E
HAB 85 20 35 E
HAB 85 30 50 E
HAB 95 20 35 E
HAB 95 30 50 E
5.03.0
5.03.0
5.03.5
3.5
3.5
3.02.0
2.0
2.0
Healing AbutmentUnit: mm, Scale 1.5 : 1
10 SuperLine II Product Catalog
Prosthetic Procedure 1Impression Technique and Restoration Selection
Page 17
Dual / Combi Abutment
Closed Tray Technique
Cemented Restoration
Modi�cation
Abutment Level Impression
Burn-out Cylinder
Impression CopingTransfer (Snap on) Ø 4.5 / Ø 5.5 / Ø 6.5
Page 13
Combi AbutmentØ 4.5 / Ø 5.5 / Ø 6.5
Dual AbutmentHex / Non-hex Ø 4.5 / Ø 5.5 / Ø 6.5
Page 14,15
Page 16
Page 16 Page 16
AnalogLong Ø 4.5 / Ø 5.5 / Ø 6.5
BridgeRotationalØ 4.5 / Ø 5.5 / Ø 6.5
SingleNon-rotationalØ 4.5 / Ø 5.5 / Ø 6.5
Page 16
AnalogShort Ø 4.5 / Ø 5.5 / Ø 6.5
SuperLine II Product Catalog 11
※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Combi Abutment with the implant and re-thighten with the same torque after 15 min. to reach the maximum screw tension.
Combi Abutment Unit: mm, Scale 1 : 1
CAB5525FXS4510C
Diameter G/H Type TypeArt. No. Art. No.
Ø 4.5
Ø 5.5
Ø 6.5
1.0
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
Short
Short
Short
Long
Long
Long
CAB 45 10 S
CAB 45 15 S
CAB 45 25 S
CAB 45 35 S
CAB 45 45 S
CAB 45 55 S
CAB 55 15 S
CAB 55 25 S
CAB 55 35 S
CAB 55 45 S
CAB 55 55 S
CAB 65 15 S
CAB 65 25 S
CAB 65 35 S
CAB 65 45 S
CAB 65 55 S
CAB 45 10
CAB 45 15
CAB 45 25
CAB 45 35
CAB 45 45
CAB 45 55
CAB 55 15
CAB 55 25
CAB 55 35
CAB 55 45
CAB 55 55
CAB 65 15
CAB 65 25
CAB 65 35
CAB 65 45
CAB 65 55
• Tissue contour design, Gold hue• Compatible throughout all Dentium SuperLine & Implantium series
G/H 2.5
4.0
1.5
Diameter Ø 5.5
1.04.0
1.05.5
1.54.0
1.5
5.5
1.5
1.5
1.5
1.5
5.5
5.5
4.0
4.0
2.54.0
2.5
5.5
2.5
2.5
2.5
2.5
5.5
5.5
4.0
4.0
3.5
4.0
3.5
5.5
3.5
3.5
3.5
3.5
5.5
5.5
4.0
4.0
4.5
4.0
4.5
5.5
4.5
4.5
4.5
4.5
5.5
5.5
4.0
4.0
4.0
5.5
5.5
5.5
5.5
5.5
4.0
4.0
5.5
5.5
5.5
5.5
Dual Abutment [Hex]Unit: mm, Scale 1.5 : 1
DAB5525HFXS4510C
Diameter G/H Art. No.
Ø 4.5
Ø 5.5
Ø 6.5
1.0
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
DAB 45 10 H
DAB 45 15 H
DAB 45 25 H
DAB 45 35 H
DAB 45 45 H
DAB 45 55 H
DAB 55 15 H
DAB 55 25 H
DAB 55 35 H
DAB 55 45 H
DAB 55 55 H
DAB 65 15 H
DAB 65 25 H
DAB 65 35 H
DAB 65 45 H
DAB 65 55 H
※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Dual Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
• Tissue contour design, Gold hue• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
G/H 2.5
4.0
1.5
Diameter Ø 5.5
1.0 1.5
1.5
1.5
2.5
2.5
2.5
3.5
3.5
3.5
4.5
4.5
4.5
5.5
5.5
5.5
5.5 5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
12 SuperLine II Product Catalog
SuperLine II Product Catalog 13
Dual Abutment [Non-hex]Unit: mm, Scale 1.5 : 1
DAB5525NFXS4510C
Diameter G/H Art. No.
Ø 4.5
Ø 5.5
Ø 6.5
1.0
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
DAB 45 10 N
DAB 45 15 N
DAB 45 25 N
DAB 45 35 N
DAB 45 45 N
DAB 45 55 N
DAB 55 15 N
DAB 55 25 N
DAB 55 35 N
DAB 55 45 N
DAB 55 55 N
DAB 65 15 N
DAB 65 25 N
DAB 65 35 N
DAB 65 45 N
DAB 65 55 N
※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Dual Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
• Tissue contour design, Gold hue• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
G/H 2.5
4.0
1.5
Diameter Ø 5.5
1.0 1.5
1.5
1.5
2.5
2.5
2.5
3.5
3.5
3.5
4.5
4.5
4.5
5.5
5.5
5.5
5.5 5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
14 SuperLine II Product Catalog
Abutment Level Impression ComponentsUnit: mm, Scale 1 : 1
Comfort Cap I Snap on
Lab Analog
Burn-out Cylinder
Impression Coping
Type
Type
Type
Diameter
Diameter
Diameter
Diameter
Art. No.
Art. No.
Art. No.
Art. No.
Short
Short
Single
Long
Long
Bridge
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
Ø 4.5
Ø 5.5
Ø 6.5
CCC 45 CS
CCC 55 CS
CCC 65 CS
CAN 45 SL
CAN 55 SL
CAN 65 SL
CBC 45 SL
CBC 55 SL
CBC 65 SL
CIC 45 L
CIC 55 L
CIC 65 L
CCC 45 C
CCC 55 C
CCC 65 C
CAN 45 LL
CAN 55 LL
CAN 65 LL
CBC 45 BL
CBC 55 BL
CBC 65 BL
4.8
4.0
12.8
12.8
5.5
12.0
12.0
6.8
10.4
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
Ø 5.5
Ø 5.5
Ø 5.5
Ø 5.5
Ø 5.5
Ø 6.5
Ø 6.5
Ø 6.5
Ø 6.5
Ø 6.5
Ø 4.5 Ø 5.5 Ø 6.5
• Compatible throughout all Dentium SuperLine & Implantium series
SuperLine II Product Catalog 15
Restorative Kit
XSDAB 45 S
XSDAB 45
XSDAB 55 S
XSDAB 55
XSDAB 65 S
XSDAB 65
CCC 45 CS
CCC 45 C
CCC 55 CS
CCC 55 C
CCC 65 CS
CCC 65 C
CAN 45 SL
CAN 45 LL
CAN 55 SL
CAN 55 LL
CAN 65 SL
CAN 65 LL
CBC 45 SL
CBC 55 SL
CBC 65 SL
CBC 45 BL
CBC 55 BL
CBC 65 BL
CIC 45 L
CIC 55 L
CIC 65 L
Comfort Cap Impression Coping Analog
Lab. Components
Burn-out Cylinder
Combi & Dual Abutment
Art. No
• Compatible throughout all Dentium SuperLine & Implantium series
Prosthetic Procedure 2Impression Technique and Restoration Selection
Modi�cation Modi�cation
Cemented Restoration Screw-Retained Restoration
DualAbutmentHex / Non-hexØ 4.5 / Ø 5.5 / Ø 6.5
Ti-Base CustomAbutmentHex / Non-hexØ 4.5 / Ø 5.5
Page 14,15
Page 24,25
Page 21 Page 28
Page 26,27 Page 29 Page 29
Bone Level Impression
Impression Coping TransferClosed tray technique (Simple case)Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5
Hex Non-hex
MillingAbutmentHex / Non-hexØ 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5 / Ø 7.5
AnalogØ 4.5
AngledAbutmentHex / Non-hex15° / 25° Ø 4.5 / Ø 5.5
Metal-CastingAbutmentHex / Non-hexØ 4.5
Ti-TemporaryAbutmentHex / Non-hexØ 4.5
PlasticTemporaryAbutmentHex / Non-hexØ 4.5 / Ø 5.5 / Ø 6.5
Hex Non-hex
Impression Coping Pick-upOpen tray technique (Complicated case)Ø 4.0 / Ø 4.5 / Ø 5.5 / Ø 6.5
Page 19 Page 20
Page 19,20
Dual / Custom / Milling / Angled / Direct-Casting / Metal-Casting / Ti-Temporary / Plastic Temporary Abutment
Page 28
Direct-CastingAbutmentHex / Non-hexØ 4.5
16 SuperLine II Product Catalog
SuperLine II Product Catalog 17
Bone Level Impression ComponentsUnit: mm, Scale 1 : 1
Diameter
Size
Diameter
Type
L
L
Size Art. No.
Art. No.
Art. No.
Ø 4.0
Short
Long
Ø 4.5
Ø 4.5
Ø 5.5
Ø 6.5
Hex
Non-hex
Hex
Non-hex
23.0
27.0
12.0
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Short
Short
Long
Long
Short
Short
Long
Long
Short
Short
Long
Long
Short
Short
Long
Long
DPU 40 11 HE
DPU 40 11 NE
DPU 40 15 HE
DPU 40 15 NE
DPS 11 E
DPS 15 E
DANSE
DPU 45 11 HE
DPU 45 11 NE
DPU 45 15 HE
DPU 45 15 NE
DPU 55 11 HE
DPU 55 11 NE
DPU 55 15 HE
DPU 55 15 NE
DPU 65 11 HE
DPU 65 11 NE
DPU 65 15 HE
DPU 65 15 NE
Impression Coping Pick-up
Impression Coping Pick-Up Screw
Analog
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
23.0
12.0
27.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
Hex
Hex
Hex
Hex
Short
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Long
Non-hex
Non-hex
Non-hex
Non-hex
Ø 4.5
• DANSE is a single analog for all Dentium SuperLine II and SuperLine & Implantium implants for platform Ø 4.0 above. • For SuperLine & Implantium Ø 3.6, use DAN34 in the page 25 of ‘SuperLine & Implantium (PN2432-07)’ catalog.
• Impression coping screw is included with Impression coping• Compatible throughout all Dentium SuperLine & Implantium series
※Hex driver: It is recommended to keep the torque level at 5~10N·cm.
• Tissue contour design
18 SuperLine II Product Catalog
Bone Level Impression ComponentsUnit: mm, Scale 1 : 1
Diameter
Size
Diameter
Type
L
L
Size Art. No.
Art. No.
Art. No.
Ø 4.0
Short
Long
Ø 4.5
Ø 4.5
Ø 5.5
Ø 6.5
Hex
Non-hex
Hex
Non-hex
17.0
21.0
12.0
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Short
Short
Long
Long
Short
Short
Long
Long
Short
Short
Long
Long
Short
Short
Long
Long
DTF 40 11 HE
DTF 40 11 NE
DTF 40 15 HE
DTF 40 15 NE
DTS 11 E
DTS 15 E
DANSE
DTF 45 11 HE
DTF 45 11 NE
DTF 45 15 HE
DTF 45 15 NE
DTF 55 11 HE
DTF 55 11 NE
DTF 55 15 HE
DTF 55 15 NE
DTF 65 11 HE
DTF 65 11 NE
DTF 65 15 HE
DTF 65 15 NE
Impression Coping Transfer
Impression Coping Transfer Screw
Analog
11.0
11.0
11.0
11.0
11.0
11.0
11.0
11.0
17.0
12.0
21.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
Hex
Hex
Hex
Hex
Short
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Long
Non-hex
Non-hex
Non-hex
Non-hex
Ø 4.5
• DANSE is a single analog for all Dentium SuperLine II and SuperLine & Implantium implants for platform Ø 4.0 above. • For SuperLine & Implantium Ø 3.6, use DAN34 in the page 25 of ‘SuperLine & Implantium (PN2432-07)’ catalog.
• Impression coping screw is included with Impression coping• Compatible throughout all Dentium SuperLine & Implantium series
※Hex driver: It is recommended to keep the torque level at 5~10N·cm.
• Tissue contour design
SuperLine II Product Catalog 19
Top view
Ø 5.5
Ø 4.5
Ti-Base Custom AbutmentUnit: mm, Scale 1.5 : 1
G/H 1.0
5.5
CDAB5510HEFXS4510C
Diameter Ø 5.5
※
Hex
Hex
Non-hex
Non-hex
Hex
Hex
Non-hex
Non-hex
1.5 1.50.5 0.5
1.0 1.0 2.0 2.0
Diameter TypeG/H Art. No.
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
0.5
0.5
1.5
1.5
1.0
1.0
2.0
2.0
CDAB 45 05 HE
CDAB 45 05 NE
CDAB 45 15 HE
CDAB 45 15 NE
CDAB 55 10 HE
CDAB 55 10 NE
CDAB 55 20 HE
CDAB 55 20 NE
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Custom Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
Unit: mm, Scale 1 : 0.8
Diameter Type Art. No.
Ø 10.0 Hex
Non-hex
CMAB 10 HAL
CMAB 10 NA
Diameter Type Art. No.
Ø 14.0 Hex
Non-hex
CMAB 14 HAL
CMAB 14 NA
Diameter Type Art. No.
Ø 15.0 Hex
Non-hex
CMAB 15 HAL
CMAB 15 NA
Titanium Abutment Blanks
Ø 14.0
Ø 15.0
Ø 14.0
Ø 15.0
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Ø 10.0 Ø 10.0
Ø 2.3
Ø2.0
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
20 SuperLine II Product Catalog
SuperLine II Product Catalog 21
Unit: mm, Scale 1.5 : 1
Digital Impression Components
Scanning Jig
Scanning Jig
Digital Analog
for Titanium Abutment Blanks
for Screw Abutment
ShortLong
3.5
10.0
12.0 12.0
Hex Non-hex
Ø 4.5
Ø 4.5, 5.5 Ø 4.5, 5.5
12.0
4.5
1.8
2.3
2.0
2.3
DAN 38D
3.5
5.5
Ø 4.5
Diameter Type Art. No.
Ø 4.5, 5.5Hex
Non-hex
Single
Bridge
SCJ E4555
SCJ E4555N
Diameter Type Art. No.
Ø 4.5Hex
Hex
Single
Bridge
SCJ I4565
SCJ I4565S
• Ti-retaining screw (SRS18) included
• Abutment screw (ASC2045) included
• DAN38D is for all diameters for SuperLine II and SuperLine & Implantium implants except for SuperLine & Implantium (Platform: Ø3.6 / Body: Ø3.4) implant. • For SuperLine & Implantium (Platform: Ø3.6 / Body: Ø3.4) implant, use DAN34D in page 29 of ‘SuperLine & Implantium (PN2432-07)’ catalog.
• Compatible throughout all Dentium SuperLine & Implantium series
Diameter L Art. No.
Ø 4.5 12.0 DAN 38D
22 SuperLine II Product Catalog
Milling AbutmentUnit: mm, Scale 1.5 : 1
MAB55157HFXS4510C
Diameter TypeG/H Art. No.
Ø 4.0
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
MAB 40 105 H
MAB 40 105 N
MAB 45 156 H
MAB 45 156 N
MAB 55 157 H
MAB 55 157 N
MAB 55 257 H
MAB 55 257 N
Diameter TypeG/H Art. No.
Diameter TypeG/H Art. No.
※Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Milling Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hue
G/H 1.5
12.0
Diameter Ø 5.5
Hex
Hex
HexHex
Non-hex
Non-hex
Non-hexNon-hex
1.0
1.5
2.51.5
1.5
2.51.5
1.0
SuperLine II Product Catalog 23
Milling AbutmentUnit: mm, Scale 1.5 : 1
Diameter
Diameter
Type
Type
G/H
G/H
Art. No.
Art. No.
Ø 6.5
Ø 7.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
1.5
1.5
2.5
2.5
3.5
3.5
2.5
2.5
3.5
3.5
MAB 65 158 H
MAB 65 158 N
MAB 65 258 H
MAB 65 258 N
MAB 65 358 H
MAB 65 358 N
MAB 75 259 H
MAB 75 259 N
MAB 75 359 H
MAB 75 359 N
• Abutment screw is included
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Milling Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hue
Hex
Hex
Hex
Hex Non-hex
Non-hex
Non-hex
Non-hex
2.5
2.5
3.5
1.5 2.5
2.5
3.5
Hex Non-hex
3.5 3.5
1.5
Angled Abutment [15°]Unit: mm, Scale 1.5 : 1
Diameter
Diameter
Type
Type
G/H
G/H
Art. No.
Art. No.
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
1.5
1.5
2.5
2.5
3.5
3.5
1.5
1.5
2.5
2.5
3.5
3.5
AAB 15 45 15 H
AAB 15 45 15 N
AAB 15 45 25 H
AAB 15 45 25 N
AAB 15 45 35 H
AAB 15 45 35 N
AAB 15 55 15 H
AAB 15 55 15 N
AAB 15 55 25 H
AAB 15 55 25 N
AAB 15 55 35 H
AAB 15 55 35 N
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
AAB155525HFXS4510C
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hue
G/H 2.5
Diameter Ø 4.5
15°
Hex
Hex
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
1.5
1.5
2.5
2.5
3.5
3.5
1.5
1.5
2.5
2.5
3.5
3.5
24 SuperLine II Product Catalog
SuperLine II Product Catalog 25
Angled Abutment [25°]Unit: mm, Scale 1.5 : 1
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
AAB255525HFXS4510C
Diameter
Diameter
Type
Type
G/H
G/H
Art. N .
Art. No.
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
1.5
1.5
2.5
2.5
3.5
3.5
1.5
1.5
2.5
2.5
3.5
3.5
AAB 25 45 15 H
AAB 25 45 15 N
AAB 25 45 25 H
AAB 25 45 25 N
AAB 25 45 35 H
AAB 25 45 35 N
AAB 25 55 15 H
AAB 25 55 15 N
AAB 25 55 25 H
AAB 25 55 25 N
AAB 25 55 35 H
AAB 25 55 35 N
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hue
Hex
Hex
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
1.5
1.5
2.5
2.5
3.5
3.5
1.5
1.5
2.5
2.5
3.5
3.5
G/H 2.5
25°
Diameter Ø 4.5
26 SuperLine II Product Catalog
Direct-Casting Abutment
Metal-Casting Abutment
Unit: mm, Scale 1.5 : 1
Unit: mm, Scale 1.5 : 1
• Abutment screw is included
• Abutment screw is included
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Direct/Metal-Casting Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
4.5
Diameter Ø 4.5
G/HDiameter Type Art. No.
1.0Ø 4.5Hex
Non-hex
RAB 45 CLH
RAB 45 CLN
RAB45CLHFXS4510C Hex
1.0
Co-Cr
Non-hex
1.0
G/H 1.0
12.0
※
• Compatible throughout all Dentium SuperLine & Implantium series
• Compatible throughout all Dentium SuperLine & Implantium series
4.5
Diameter Ø 4.5
G/HDiameter Type Art. No.
1.0Ø 4.5Hex
Non-hex
RAB 45 GH
RAB 45 GN
RAB45GHFXS4510C Hex
1.0
Non-hex
Gold
1.0
G/H 1.0
12.0
SuperLine II Product Catalog 27
Hex
1.0
Non-hex Hex
3.0 3.0
Non-hex
1.0
10.0
Ti-Temporary Abutment
Plastic Temporary Abutment
Unit: mm, Scale 1.5 : 1
Unit: mm, Scale 1.5 : 1
• Abutment screw is included.
Diameter Ø 4.5
Diameter Ø 4.5
G/H
G/H
Diameter
Diameter
Type
Type
Art. No.
Art. No.
1.0
3.0
2.0
2.0
2.0
Ø 4.5
Ø 4.5
Ø 5.5
Ø 6.5
Hex
Non-hex
Hex
Non-hex
Hex Non-hex
Hex Non-hex
Hex Non-hex
TAB 4510 HG
TAB 4510 NG
TAB 4530 HG
TAB 4530 NG
RAB 45 20 PHLRAB 45 20 PNL
RAB 55 20 PHL RAB 55 20 PNL
RAB 65 20 PHL RAB 65 20 PNL
TAB45HGFXS4510C
RAB4520PHLFXS4510C
Hex
Hex
Hex Non-hex
Non-hex
Non-hex
G/H 1.0
G/H 2.0
2.0 2.0 2.0
2.02.0
2.0
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Ti/Plastic Temporary Abutment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
• Compatible throughout all Dentium SuperLine & Implantium series
• Abutment screw is included.• Compatible throughout all Dentium SuperLine & Implantium series
Screw Abutment
Open tray technique Closed tray technique
Screw-Retained Restoration
Abutment Level Impression
Impression Technique and Restoration Selection
Burn-out Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5
Polishing ProtectorØ 4.5 / Ø 5.5
Ti-Retaining Screw
Gold Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5
Metal Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5
Ti Temporary Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5
Ti Cylinder(Hex / Non-hex)Ø 4.5 / Ø 5.5
Temporary Restoration
Page 35
Page 33
Page 34
Page 35 Page 35 Page 35Page 34
Page 31
Page 34
Page 33 Page 33
Page 32
Screw AbutmentØ 4.5 / Ø 5.5
AnalogØ 4.5 / Ø 5.5
Angled Screw AbutmentHex / Non-hex 20° Ø 4.5 / Ø 5.5
Prosthetic Procedure 3
Impression Coping Pick-up Ø 4.5 / Ø 5.5 / Ø 6.5
Impression Coping TransferØ 4.5 / Ø 5.5 / Ø 6.5
28 SuperLine II Product Catalog
SuperLine II Product Catalog 29
Screw AbutmentUnit: mm, Scale 1.5 : 1
DeliveryHolder
SAB5525FXS4510C
Diameter
Diameter
G/H
G/H
Art. No.
Art. No.
Ø 4.5
Ø 5.5
1.0
1.5
2.5
3.5
4.5
5.5
1.5
2.5
3.5
4.5
5.5
SAB 45 10
SAB 45 15
SAB 45 25
SAB 45 35
SAB 45 45
SAB 45 55
SAB 55 15
SAB 55 25
SAB 55 35
SAB 55 45
SAB 55 55
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Screw Abutment with the implant and re-tighten it after 15 min.
※
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hueG/H 2.5
Diameter Ø 5.5
1.0 1.5
1.5
2.5
2.5
3.5
3.5
4.5
4.5
5.5
5.5
30 SuperLine II Product Catalog
Angled Screw AbutmentUnit: mm, Scale 1.5 : 1
ASA5520HFXS4510C
※15° and 30° angles are also available with Titanium G4, strait G/H design. Please refer to SuperLine & Implantium Product Catalog P38.
7.3
Ø 2.0
Diameter
Diameter
Type
Type
G/H
G/H
Art. No.
Art. No.
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
1.0
1.0
2.0
2.0
3.0
3.0
1.0
1.0
2.0
2.0
3.0
3.0
ASA 45 10 H
ASA 45 10 N
ASA 45 20 H
ASA 45 20 N
ASA 45 30 H
ASA 45 30 N
ASA 55 10 H
ASA 55 10 N
ASA 55 20 H
ASA 55 20 N
ASA 55 30 H
ASA 55 30 N
Diameter L Art. No.
Ø 2.3 7.3 ASASC 20 23
Angled Screw Abutment ScrewØ 2.3
DeliveryHolder
ASAH
Ti-Delivery Holder
15.8
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Angled Screw Abutment with the implant and re-tighten it after 15 min.
※
• Abutment screw is included• Compatible throughout all Dentium SuperLine & Implantium series
• Tissue contour design, Gold hueG/H 2.0
Diameter Ø 5.520°
3.0 3.0
1.02.54
2.88
4.88
2.88 3.88 3.88
4.54 4.54
2.54 3.54 3.54
1.0
1.0
1.0
2.0
2.0
3.0 3.0
2.0
2.0
Hex
Hex
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
Non-hex
4.88
SuperLine II Product Catalog 31
SuperLine II Product Catalog 7
Screw Abutment Impression ComponentsUnit: mm, Scale 1.5 : 1
15.0
9.0
Diameter
Diameter
Type
Type
Art. No.
Art. No.
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
SPU 45 SL
SPU 45 BL
SPU 55 SL
SPU 55 BL
STF 45 SL
STF 45 BL
STF 55 SL
STF 55 BL
Type L Art. No.
Pick-up
Transfer
15.0
9.0
SPS 09
STS 09
Impression Coping Screw
Hex
Hex
Hex
Hex
Non-hex
Non-hex
Non-hex
Non-hex
Ø 4.5
Ø 4.5
Ø 5.5
Ø 5.5
Ø 4.5
Ø 4.5
Ø 5.5
Ø 5.5
Impression Coping Pick-up
Impression Coping Transfer
• Compatible throughout all Dentium SuperLine & Implantium series
※Hex driver: It is recommended to keep the torque level at 5~10N·cm.
Screw Abutment ComponentsUnit: mm, Scale 1.5 : 1
Diameter
Diameter
Diameter
Diameter
L
L
L
L
Art. No.
Art. No.
Art. No.
Art. No.
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
5.0
5.0
12.0
4.71
SCC 45 T
SCC 55 T
SCC 45 L
SCC 55 L
SAN 45 L
SAN 55 L
SPP 45 L
SPP 55 L
Comfort Cap
Comfort Cap
Analog
Polishing Protector
5.0
5.0
12.0
5.5 5.5
5.5 5.5
0.8 0.8
0.8 0.8
5.0
5.0
12.0
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5 Ø 4.5
Ø 5.5 Ø 5.5
Ø 4.5
Ø 5.5
Ø 5.5
Ø 5.5
Ø 5.5
5.0
4.71 4.71
Ø 1.8
Diameter L Art. No.
Ø 2.3 5.0 SRS 18 T
Ti-Retaining Screw Ø 2.3
Diameter Type Art. No.
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
STA 45 S
STA 45 B
STA 55 S
STA 55 B
Ti-Cylinder
Hex
Hex
Non-hex
Non-hex
• Compatible throughout all Dentium SuperLine & Implantium series
※Hex driver: It is recommended to keep the torque level at 5~10N·cm.
32 SuperLine II Product Catalog
SuperLine II Product Catalog 33
Screw Abutment ComponentsUnit: mm, Scale 1.5 : 1
8.7
12.0
12.0
12.0
8.7
12.0
12.0
12.0
3.3 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
Ø 5.5
Ø 5.5
Ø 5.5
Ø 5.5
Diameter
Diameter
Diameter
Diameter
Type
Type
Type
Type
Art. No.
Art. No.
Art. No.
Art. No.
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Ø 4.5
Ø 5.5
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
STC 45 SG
STC 45 BG
STC 55 SG
STC 55 BG
SGC 45 SL
SGC 45 BL
SGC 55 SL
SGC 55 BL
SGC 45 CSL
SGC 45 CBL
SGC 55 CSL
SGC 55 CBL
SBC 45 SL
SBC 45 BL
SBC 55 SL
SBC 55 BL
Ti-Temporary Cylinder
Gold Cylinder
Metal Cylinder I Co-Cr
Burn-out Cylinder
• Compatible throughout all Dentium SuperLine & Implantium series
※Hex driver: It is recommended to keep the torque level at 5~10N·cm.
Impression Technique and Restoration Type
Overdenture Procedure (Laboratory)
Prosthetic Procedure 4
Socket Spacer
Ø 4.05 / Ø 4.85
Mini Ball Female Socket / O-ring
Ø 4.05 / Ø 4.85
Mini Ball / Locator® Abutment / Locator™ R-Tx
Mini Ball Impression Coping
Mini Ball Abutment
Ø 3.5
Page 37
Locator®Impression Coping
Page 38
Page 37
Locator®Abutment
Ø 3.85
Page 38
Mini Ball Analog
Ø 3.5
Page 37
Locator® Spacer& DentureCap Assembly
Page 39
Page 37
Locator StandardReplacement Males
Locator ExtendedReplacement Males
Page 39
Page 37
Locator® Analog
Ø 4.0 / Ø 5.0
Page 38
Locator™ R-TxImpression Coping
Page 41
Locator™ R-TxAbutment
Ø 3.85
Page 41
Locator™ R-Tx Spacer& DentureCap Assembly
Page 42
Locator™ R-Tx StandardRetention Inserts
Locator™ R-Tx Low Retention Limited Range Inserts
Page 42
Locator™ R-TxAnalog Ø 4.0 / Ø 5.0
Page 41
Abutment Level Impression
34 SuperLine II Product Catalog
SuperLine II Product Catalog 35
(BFS 3) (BNO 1) (BFS 2) (BNO 2)
Ø 4.05 Ø 4.85
2.9 3.3
Mini Ball AttachmentUnit: mm, Scale 1.5 : 1
G/H 2.0
2.9
BPF3 BAB352018 FXS4510C
Diameter Ø 4.05
4.2
1.0 2.0 3.0 4.0 5.0
Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8 Ø 1.8
Diameter
Diameter
Diameter
L Art. No.
Art. No.
Art. No.
Ø 3.4
Ø 3.5
Ø 4.05
Ø 4.85
4.2 GICA
BANL
GBIC 3 L
GBIC 2 L
Diameter Retention Force Art. No.
Ø 4.05
Ø 4.85
300~500 gf, 0.66~1.10 lbf
500~700 gf, 1.10~1.54 lbf
BPF 3
BPF 2
Mini Ball Impression Coping
Mini Ball Analog
Socket Spacer
Female Socket
Ø 3.4
Ø 4.05 Ø 4.85
Ø 3.3 Ø 3.5 Ø 3.5 Ø 3.5 Ø 3.5 Ø 3.5
Diameter G/H Art. No.
Ø 3.3
Ø 3.5
Ø 3.5
Ø 3.5
Ø 3.5
Ø 3.5
0
1.0
2.0
3.0
4.0
5.0
BAB 35 00 18
BAB 35 10 18
BAB 35 20 18
BAB 35 30 18
BAB 35 40 18
BAB 35 50 18
Mini Ball Abutment
Ø 1.8Ø 3.5
0.5
Diameter H Art. No.
Ø 6.5 0.5 BOS
Block Out SpacerØ 6.5
Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Mini Ball Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
• Compatible throughout all Dentium SuperLine & Implantium series
Locator® Abutment
0.501.50 2.0 3.0 4.0
5.0
Qty Art. No.
4 / pack 08505
Locator® Impression Coping
Locator® Analog
4 / pack
Ø 3.85 Ø 3.85 Ø 3.85 Ø 3.85 Ø 3.85Diameter Cu� Height Art. No.
Ø 3.85
0.5
2.0
3.0
4.0
5.0
08656
08657
08658
08659
08660
Locator® Abutment
If using a Ø3.6mm platform / Ø3.4mm body SuperLine I & Implantium (not applicable for SuperLine II), the abutmentis 0.5mm higher compared to that with larger diameters.Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Locator® Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
※
• Compatible throughout all Dentium SuperLine & Implantium series
Diameter Art. No.
Ø 4.0
Ø 5.0
08530
08516
Ø 4.0 Ø 5.0
1.501.50
1.501.50
Qty
C/H 2.0
08657FXS4510C
Locator®Processing Package
Abutment Diameter Ø 3.85
36 SuperLine II Product Catalog
SuperLine II Product Catalog 37
Locator® Abutment
Qty Art. No.
4 / packProcessing SpacerBlock-out Spacer
0856908514
Locator® Spacer
Locator® Denture Cap Assembly
ColorRentention ForcePivot Art. No.
BlueExtra Light(680 gf, 1.5 lbs)
Light(1361 gf, 3.0 lbs)
Regular(1361 gf, 3.0 lbs)
Pink
Clear
08529
08527
08524
Locator® Standard Replacement Males (4 / pack)
Qty Type Art. No.
2 / pack
Standard (Convergence/Divergence ± 10° )
Extended(Convergence/Divergence ± 20°)
08519-2
08540-2
Locator® Processing Package
Standard Extended
Block-out Spacer Processing Spacer
Blue Pink Clear
Denture CapAssembly
Black ProcessingMale
ColorRentention Force Art. No.
GreyZero(0 gf, 0 lbf)
Red
Orange
Green
08558
08548
08915
08547
Locator® Extended Replacement Males (4 / pack)
Grey Red Orange Green
• Compatible throughout all Dentium SuperLine & Implantium series
Extra Light(454 gf, 1.0 lbf)
Light(907 gf, 2.0 lbf)
Regular(1814 gf, 4.0 lbf)
±10°
±20°
Pivot
Standard replacement: Convergence/Divergence ± 10°
Extended replacement: Convergence/Divergence ± 20°
Type
Qty Art. No.
Denture Cap Assembly4 / pack
08510-4Black Processing Male 08515
Type
38 SuperLine II Product Catalog
Tools
Type Qty Art. No.
Locator® Parallel Post
Locator® Core Tool
Dentium Torque Wrench
Locator®Angle Measurement Guide
08393
Locator® Core Tool Tip 08397
Locator® Abutment Holder Sleeve 08394
08517
XNTW
09530
Locator® Abutment• Compatible throughout all Dentium SuperLine & Implantium series
Drivers
Locator®Torque Wrench Driver
15
21
08926
0892715.0 21.0
LengthType Art. No.
Dentium Torque WrenchLocator® Angle Measurement Guide Locator® Parallel Post
Locator® Core Tool
Core Tool Tip:Removal of
replacement malesSeating of
replacement malesAbutment
driverAbutment
holder sleeve
4 / pack
1
1
1
1
1
SuperLine II Product Catalog 39
R-Tx™ Abutment
Qty Art. No.
4 / pack 30017-01
R-Tx™ Impression Coping
R-Tx™ Analog
R-Tx™ Abutment
Ø 4.0
Ø 5.0
30015-01
30016-01
Ø 4.0 Ø 5.0
Diameter Cu� Height Art. No.
Ø 3.85
1.0
2.0
3.0
4.0
5.06.0
32801-01-DE-SB
32801-02-DE-SB
32801-03-DE-SB
32801-04-DE-SB
32801-05-DE-SB32801-06-DE-SB
If using a Ø3.6mm platform / Ø3.4mm body SuperLine I & Implantium (not applicable for SuperLine II), the abutmentis 0.5mm higher compared to that with larger diameters.Hex driver: It is recommended to keep the torque level at 25~30 N·cm to tighten Locator® Attachment with the implant and re-tighten with the same torque after 15 min. to reach the maximum screw tension.
※
※
4 / pack
Diameter Art. No.Qty
• Compatible throughout all Dentium SuperLine & Implantium series
3.0
Ø 3.85
1.50
Ø 3.85
4.0
1.50
Ø 3.85
5.0
1.50
Ø 3.85
6.0
1.50
C/H 3.0
32801-03-DE-SB R-Tx All-in-onePackage
FXS4510C
Abutment Diameter Ø 3.85
1.01.50
Ø 3.85
2.0
Ø 3.85
1.50
Qty Art. No.
2 / pack
R-Tx™ Mixed Retention Limited Range Processing Package
30030-01
ColorRentention Force Art. No.
Aqua
Magenta
Gold
Standard Retention Inserts (4 / pack)
Spacer
Aqua Magenta Gold
ColorPivot
Pivot
Rentention Force Art. No.
Grey
Blue
PinkClear
30001-01
30002-0130003-01
30004-01
30027-01
30028-01
30029-01
Low Retention Limited Range Inserts (4 / pack)
Grey Blue Pink Clear
R-Tx™ Abutment• Compatible throughout all Dentium SuperLine & Implantium series
±30°
±30°
Zero
Low
Medium
High
Zero
Low
Medium
Standard Retention: Convergence/Divergence ± 30°
Low Retention: Convergence/Divergence ± 30°
30027-01 30028-01 30029-01
Qty Art. No.
4 / packSpacer 30018-01
R-Tx™ Spacer
R-Tx™ Denture Cap Assembly
Denture CapAssembly
Black ProcessingMale
Type
Qty Art. No.
Denture Cap Assembly4 / pack
30013-01Black Processing Male 30012-01
Type
40 SuperLine II Product Catalog
SuperLine II Product Catalog 41
Tools
Drivers
Type Art. No.
Retention Insert Tool (Dual Sided)
Dentium Torque Wrench
30021-01
XNTW
Hex Driver Manual [w/wheel]
Hex Driver Hand-piece
Hex Driver Ratchet
26
30
25
21
25
XHD26T
XHD30T
XHD25H
XHD21W
XHD25W
27 XHD27W
LengthType Art. No.
Retention Insert Tool (Dual Sided)Dentium Torque Wrench
R-Tx™ Abutment• Compatible throughout all Dentium SuperLine & Implantium series
21 25 2726 30 25
SuperLine IIProduct Catalog
US OFFICE6731 Katella Ave., Cypress, CA 90630 Tel: 1-877-304-6752 Fax: 1-714-226-0019
www.dentiumusa.com / [email protected]
Manufacturing
Website / E-mail6731 Katella Ave., Cypress, CA 90630 Tel: 1-714-226-0229 Fax: 1-714-226-1889
PN2432-08
Speci�cations are subject to change without any notice.