mvsuvhc mvs˜uvhc tmthis document is the property of intertek testing services and is not...

10
MVSUVHC UVC GERMICIDAL DUAL HEPA FILTRATION UNIT MVSUVHC REVISION: E EFFECTIVE: 11/2020 MVS-UVHC by Man-D-Tec FOR NEW AND EXISTING ELEVATOR CABS Patent Pending, Ultra Performance, Dual UVC Germicidal & Dual HEPA filtration unit. Built specifically for elevators and PROVEN to remove 99.9% of airborne virus AND bacteria particles. This unit features a 3-speed high performance sealed ball bearing motor. The “squirrel cage” blower wheel ensures maximum air flow and quiet operation. Blows purified air down into the cab. Proprietary, fully automatic UV performance monitoring system ensures the dual UVC Germicidal unit is performing at peak levels and has LED indicators for each UV source, along with audible notification when system needs attention. COP remote mounted UV status indicators are available. This allows passengers to visually see that the system is operating, giving them confidence that their safety is a high priority. SIDE VIEW FOR OPTIONS SEE ACCESSORIES ® MVS-UVHC ® TM PATENTS PENDING 15.25 TOP VIEW 23.50 12.00 17.25 18.78 TM • Dual UVC Germicidal Sources • Dual HEPA Filtration MERV 17 (True HEPA) up to 99.97% @ 0.3 Micron Dual Carbon Filtration Shown with end panel partially removed 5018183 Conforms to: ASME A17.5 (2019) Conforms to: UL508 (2018) Certified to: CSA B44.1 (2019) 5018183 Safety Listed to meet A17.5 Elevator Code Requirements! LABORATORY TESTED! Manufacturing Location: Man-D-Tec, Inc. 8175 E. Paradise Lane Scottsdale, AZ USA EPA Est. No. 98546-AZ-1 PROVEN to remove 99.9% of airborne virus particles! Removes 97.9% of virus particles in 60 SECONDS Removes 99.5% of virus particles in 120 SECONDS Based on 250 Cubic Foot test chamber (70” x 70” x 88” H) See Microbiological Laboratory report for details VENTILATION / FANS MADE IN USA OF US & IMPORTED PARTS CARB certified Meets California ozone emissions limits

Upload: others

Post on 12-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

TM

MVSUVHCUVC GERMICIDAL DUAL HEPA FILTRATION UNIT

MVSUVHCREVISION: E

EFFECTIVE: 11/2020

MVS-UVHC by Man-D-TecFOR NEW AND EXISTING ELEVATOR CABS

Patent Pending, Ultra Performance, Dual UVC Germicidal & Dual HEPA filtration unit. Built specifically for elevators and PROVEN to remove 99.9% of airborne virus AND bacteria particles. This unit features a 3-speed high performance sealed ball bearing motor. The “squirrel cage” blower wheel ensures maximum air flow and quiet operation. Blows puri�ed air down into the cab.

Proprietary, fully automatic UV performance monitoring system ensures the dual UVC Germicidal unit is performing at peak levels and has LED indicators for each UV source, along with audible notification when system needs attention.

COP remote mounted UV status indicators are available. This allows passengers to visually see that the system is operating, giving them confidence that their safety is a high priority.

SIDE VIEWFOR OPTIONS SEE

ACCESSORIES

®

MVS-UVHC®

TM

PATENTS PENDING

15.25

TOP VIEW

23.50 12.00

17.25

18.78

TM

• Dual UVC GermicidalSources

• Dual HEPA FiltrationMERV 17 (True HEPA)

up to 99.97% @ 0.3 Micron

• Dual Carbon Filtration

Shown with end panel partially removed

5018183

Conforms to: ASME A17.5 (2019)Conforms to: UL508 (2018)

Certi�ed to: CSA B44.1 (2019)

5018183

Safety Listed to meet A17.5Elevator Code Requirements!

LABORATORY TESTED!

Manufacturing Location:Man-D-Tec, Inc.8175 E. Paradise LaneScottsdale, AZ USA

EPA Est. No. 98546-AZ-1

PROVENto remove 99.9%of airborne virus particles!

Removes 97.9% of virusparticles in 60 SECONDS

Removes 99.5% of virusparticles in 120 SECONDS

Based on 250 Cubic Foottest chamber (70” x 70” x 88” H)

See Microbiological Laboratory report for details

VEN

TILATIO

N / FA

NS

MADE IN USA OF US & IMPORTED PARTS

CARB certifiedMeets California ozone emissions limits

Page 2: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MVSUVHCSPECIFICATIONS

1.800.944.6263WWW.MANDTEC.COM

© MANDTEC 2020

MAN-D-TEC, INC.8175 E. PARADISE LANESCOTTSDALE, AZ 85260

P. 480.998.0325F. 480.998.0318

MVSUVHCREVISION: E

EFFECTIVE: 11/2020

Enclosure(MVS-UVHC)

MATERIAL H32 Aluminum

DIMENSIONS 17.25” x 23.50“ and 15.25” Height Overall Dimensions

10.20” x 6.80” Rectangular Cutout Hole OR 9.75-11.75” Diameter (using included adaptor) Call for fan grille options

SCREEN GUARD Intake and outlet �nger guards are pre-installed Input: 120 VAC, 60Hz, 3.1A RATINGS UV-C Lamps: DUAL 13 Watt, High Performance (26 Watts total)

FEATURES

• Compatible with EXISTING fan hole cutouts from many manufacturers • Dual UVC Germicidal sources & Dual HEPA filtration • True HEPA, MERV 17, up to 99.97% @ 0.3 microns - the gold standard of �ltration • Dual Carbon Filtration • Fully automatic UVC Germicidal performance monitoring system • Visual AND audible notification if the UV system needs attention • Automatic shut-down safety circuit when filter frames are removed • High performance fan unit for rapid air changes • Includes brushed stainless wall plate with adhesive backing (to notify passengers that this system has been installed and they are being protected) • Optional, remote mount real-time COP LED indicators give passengers confidence of knowing the Dual UVC Germicidal system is operational • Meets California ozone emissions limits. CARB Certified

Fan Unit(MVS-OE)

®

Wiring CONNECTION Terminal block for simple 1, 2, or 3 speed wiring

MATERIAL 16 GA Steel with black powder coat �nish

MOTOR SPEED Three speed, High Performance

MOTOR CONSTRUCTION Sealed Ball Bearing

BLADE Squirrel cage blower wheel

Compatible with EXISTINGfan cutouts 9.75” - 11.75”

Adaptor INCLUDED!

• Our ETL Authorization to Mark document is included with every unit, proving the ENTIRE unit meets A17.5 code requirements (and electrical safety requirements)• Blows purified air down INTO the cab and OUT through the vent slots, helping to reduce the risk of pulling particles upward from the �oor

TM

Included & Attached

5018183

Optional Emergency Power Unit Available

Approved for ELEVATORS!TESTED TO A17.5

ELEVATOR CODES!!

Conforms to: ASME A17.5 (2019)Conforms to: UL508 (2018)

Certi�ed to: CSA B44.1 (2019)

ELEVATOR CONTROL, ELEVATOR ACCESSORYE329545

VEN

TILATIO

N / FA

NS

Page 3: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

UVHC DUCT KITFLEX DUCT OPTION

1.800.944.6263WWW.MANDTEC.COM

UVHC DUCT KITREVISION: B

EFFECTIVE: 9/2020

An option to give you more “FLEXIBILITY”FOR CAR TOPS WITH LIMITED SPACE

Now offering an alternate way to mount our MVS®-UVHC™ on car tops with limited space

• Allows for the base fan unit to be mounted remotely from the normal fan cutout hole • Perfect for situations where the existing fan is located under the crosshead • High Visibility hose for increased safety

Included Items:

• Metal adaptor that changes the fan outlet from rectangular to 6”D round • Five feet (5’) of six inch (6”) diameter Spring Steel Reinforced flexible hose (UL94V-0 Rated) • Metal conversion adaptor which mounts to existing fan cutout hole and converts to accept hose • Assembly hardware

ACCESSORIES

AC

CE

SS

OR

IES

Great for mounting in tight spaces!

MVS-UVHC Not IncludedShown for demonstration purposes

Included adaptorattaches to most existing

fan cutout holes

PATENTS PENDING

FLEX DUCT OPTI

option to give you more “FLEXIBILITY”

Great for mounting in tight

MVS-UVHC Not IncludedShown for demonstration purposes

Includedattaches to

fan cuto

PATENTS PENDIN

Page 4: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

AUTHORIZATION TO MARK

Applicant: Manufacturer:

Address: Address:

Country: Country:

Contact: Contact:

Phone: Phone:FAX: FAX:

Email: Email:

Standard(s):

Product:

Brand Name:

Models:

This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.

Intertek Testing Services NA Inc.545 East Algonquin Road, Arlington Heights, IL 60005

Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672

Elevator and Escalator Electrical Equipment [ASME A17.5:2019 Ed.6]

Elevator and Escalator Electrical Equipment [CSA B44.1:2019 Ed.6]

Industrial Control Equipment [UL 508:2018 Ed.18]

Electrical Ventilator for Elevators

MVS-UVHC.

Man-D-Tec

Control Number: 5018183 Authorized by: for L. Matthew Snyder, Certification Manager

This document supersedes all previous Authorizations to Mark for the noted Report Number.

[email protected]@Mandtec.com

[email protected]@Mandtec.com

Party Authorized To Apply Mark: Same as ManufacturerReport Issuing Office: Lake Forest, CA

Dalton Mandy,Terry Mandy

Dalton Mandy,Terry Mandy

480-998-0325 480-998-0325NA NA

Man-D-Tec, Inc. Man-D-Tec, Inc

8175 E. Paradise LaneScottsdale, AZ 85260.

8175 E. Paradise LaneScottsdale, AZ 85260.

USA USA

This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)Covered section when made in accordance with the conditions set forth in the Certification Agreement and ListingReport. This authorization also applies to multiple listee model(s) identified on the correlation page of the ListingReport.

This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may beapplied only at the location of the Party Authorized To Apply Mark.

Page 1 of 1 ATM for Report 104390472LAX-002 ATM Issued: 12-Aug-2020ED 16.3.15 (20-Apr-17) Mandatory

Page 5: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MAN-D-TEC, INC. EFFICACY TEST REPORT SCOPE OF WORK Non-standardized Test Method: Microbial Reduction Rate Test PRODUCT MVS-UVHC Dual UV-C Germicidal & Dual HEPA Filtration Elevator Fan Unit REPORT NUMBER 104373902COL-001 ISSUE DATE 10-AUG-2020 PAGES 6 DOCUMENT CONTROL NUMBER GFT-OP-10h (6-July-2017) © 2020 INTERTEK

Page 6: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MICROBIOLOGICAL PERFORMANCE TEST REPORT

MAN-D-TEC, INC. Intertek Report: No: 104373902COL-001

Version: 6-July-2017 Page 2 of 6 GFT-OP-10h

SECTION 1 EFFICACY STUDY SUMMARY

SECTION 2 TEST PROCEDURE A room was constructed measuring 88”H X 70” W X 70” D = 249.5 cu/ft. The test unit was placed in the center of the constructed room (Photo 1) and the room sealed. A microbial suspension was then aspirated into the chamber for 30 minutes. The test unit was turned on the and samples drawn at intervals of 0, 1, 2, 3, 4, 5, 10, 15 and 30 minutes. The process was then repeated without the test unit in the chamber to provide the natural decay results. Air sampling took place using an SKC BioStage Single-stage impactor for 30 seconds at 12L/min (.424 cubic feet/min).

Client MAN-D-TEC, INC.

8175 E. Paradise Lane Scottsdale, AZ 85260

Project No. G104373902 Sample Product Dual UV-C Germicidal & Dual HEPA Filtration Elevator

Fan Unit Model MVS-UVHC

Procedural Engineer Nicholas Unger Reviewer Lee Moomaw

Dates Tested 8/03/20 – 8/07/20 Report Date 8/10/20

Standard Non-standardized Test Method: Microbial Reduction Rate Test Testing Facility Intertek Microbiological Laboratory

1717 Arlingate Ln. Columbus, OH 43228

United States

Page 7: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MICROBIOLOGICAL PERFORMANCE TEST REPORT

MAN-D-TEC, INC. Intertek Report: No: 104373902COL-001

Version: 6-July-2017 Page 3 of 6 GFT-OP-10h

Photo 1: MVS-UVHC Unit

SECTION 3 ORGANISMS Organism Name Organism Type ATCC Number Source

Phi X174 bacteriophage small, non-enveloped virus 13706-B1 Carolina Bioscience

Escherichia coli Gram negative bacteria 11229 ATCC

SECTION 3 EQUIPMENT

Equipment Type Equipment No. Calibration Due Date Micropipette CE 2587 6/12/2021

Incubator CE 2381 7/7/2021 Balance CE 1882 7/7/2021

Autoclave CE 2376 Verify Before Use Centrifuge CE 2382 For Reference Only Chamber CE 1149 For Reference Only

Collision Nebulizer CE 1139 For Reference Only Refrigerator CE 1157 For Reference Only

Pump CE 1137 For Reference Only Stopwatch SW015 10/22/2020

Ambient Temperature/RH CE 1179 For Reference Only

Page 8: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MICROBIOLOGICAL PERFORMANCE TEST REPORT

MAN-D-TEC, INC. Intertek Report: No: 104373902COL-001

Version: 6-July-2017 Page 4 of 6 GFT-OP-10h

SECTION 4 MEDIA AND REAGENTS

Type Manufacturer Lot No Expiration Date Nutrient Agar DIFCO 9346039 10/31/2024

PBS Fisher 192736 08/01/2022

SECTION 5 SAMPLE ACQUISITION

Acquisition method Shipped to Intertek Columbus

Description Dual UV-C Germicidal & Dual HEPA Filtration Elevator Fan Unit

Serial Number N/A

Arrival date 7-13-2020

Condition New

Model Various

Sample Identification No. COL2007090948-001

Development Level Prototype

Photo 2: Unit Labels

Page 9: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MICROBIOLOGICAL PERFORMANCE TEST REPORT

MAN-D-TEC, INC. Intertek Report: No: 104373902COL-001

Version: 6-July-2017 Page 5 of 6 GFT-OP-10h

SECTION 6 SUMMARY OF RESULTS

Organism Type Virus Reduction (4 minutes) Temperature Min/Max 23°C (73°F) / 25°C (77°F)

Humidity Min/Max 56 % RH / 61 % RH Organism Name Phi-X174

Percent Reduction 4 Minutes 99.9%

Organism Type Bacteria Reduction (10 minutes)

Temperature Min/Max 22°C (71°F) / 25°C (77°F) Humidity Min/Max 51 % RH / 58 % RH Organism Name E. coli

Percent Reduction 10 Minutes 99.9%

Completed by: Nicholas Unger Reviewed by: Lee Moomaw Title:

Staff Engineer Title: Engineering Team Lead

Signature: Signature

Date 10-AUG-2020 Date: 10-AUG-2020

Page 10: MVSUVHC MVS˜UVHC TMThis document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized

MICROBIOLOGICAL PERFORMANCE TEST REPORT

MAN-D-TEC, INC. Intertek Report: No: 104373902COL-001

Version: 6-July-2017 Page 6 of 6 GFT-OP-10h

Annex A: Raw Test Data

Test Parameter Test Result Natural Decay Result

Units

Organism Species Coliphage φX174 --- ATCC No. (Item # 124425) ---

Challenge Concentration 2.0 x 109 PFU/mL Samples (min) 0 TNTC TNTC No Reduction

1 55 TNTC 97.9% 2 14 TNTC 99.5% 3 6 TNTC 99.8% 4 <1 TNTC 99.9% 5 <1 TNTC 99.9% 10 <1 TNTC 99.9% 15 <1 TNTC 99.9% 30 <1 TNTC 99.9%

Results -- 99.9% Reduction

Test Parameter Test Result Natural Decay Result

Units

Organism Species E. coli --- ATCC No. 11229 ---

Challenge Concentration 8.8 x 108 PFU/mL Samples (min) 0 TNTC TNTC No Reduction

1 TNTC TNTC No Reduction 2 TNTC TNTC No Reduction 3 TNTC TNTC No Reduction 4 83 TNTC 96.5% 5 28 TNTC 98.9% 10 3 TNTC 99.9% 15 <1 TNTC 99.9% 30 <1 TNTC 99.9%

Results -- 99.9% Reduction