multi-h eng 50hz (1)

8
1 Flow rates up to: 25 m 3 /h Head up to: 70 m CE Max. operating pressure: 10 bar Max.suction pressure: 6 bar Temperature range: – 15° to + 110°C Max. ambient temperature: + 40°C ND of ports: G11/4 to G2 MULTi-H OPERATING LIMITS N.T. N o 141-1/ENG - Ed.6/05-05 240 100 70 0 Qm/h 25 H m MULTi-H MULTi-V 3 STAINLESS STEEL MULTI-STAGE HORIZONTAL PUMPS 2 pole - 50 Hz 2 ranges: stainless steel 304 and 316L Pumping of clear non-loaded fluids in the housing. agricultural and industrial sectors: Conveyance - Overpressure Sprinkling - Irrigation Washing station Draining - Filling (ponds, pools, etc.) Heating - Air conditioning Water treatment (demineralization, filtering, etc.). And incorporation in all modular systems. Catchment from a well, spring, river, pond, etc. Pumped fluids: 304 range: clear non-aggressive liquids (drinking water, glycol water, etc.). 316L range: aggressive liquids (sea water, demineralized water, chlorinated water, etc.). • MULTI-H with single-phase motor • MULTI-H with three-phase motor • Hydraulic assembly ALL STAINLESS STEEL APPLICATIONS

Upload: alfred-izquierdo

Post on 25-Nov-2015

137 views

Category:

Documents


7 download

TRANSCRIPT

  • 1Flow rates up to: 25 m3/hHead up to: 70 m CEMax. operating pressure: 10 barMax.suction pressure: 6 barTemperature range: 15 to + 110CMax. ambient temperature: + 40CND of ports: G11/4 to G2

    MULTi-HOPERATING LIMITS

    N.T. No 141-1/ENG - Ed.6/05-05

    240

    100

    70

    0 Qm/h25

    Hm

    MULTi-H MULTi-V

    3

    STAINLESS STEEL MULTI-STAGEHORIZONTAL PUMPS

    2 pole - 50 Hz2 ranges: stainless steel 304 and 316L

    Pumping of clear non-loaded fluids in thehousing. agricultural and industrial sectors: Conveyance - Overpressure Sprinkling - Irrigation Washing station Draining - Filling (ponds, pools, etc.) Heating - Air conditioning Water treatment (demineralization,

    filtering, etc.).

    And incorporation in all modular systems.Catchment from a well, spring, river,pond, etc.Pumped fluids: 304 range: clear non-aggressive liquids

    (drinking water, glycol water, etc.). 316L range: aggressive liquids (sea water,

    demineralized water, chlorinated water,etc.).

    MULTI-H with single-phase motor MULTI-H with three-phase motor

    Hydraulic assembly ALL STAINLESS STEEL

    APPLICATIONS

  • 2MULTi-H

    STANDARD CONSTRUCTION

    ADVANTAGES

    DESIGN

    HYDRAULIC PRESELECTION CHARTS

    Hydraulic part

    ALL STAINLESS STEELHorizontal, centrifugal, not self-priming.Multi-stage from 2 to 6 stages.Axial suction, vertical discharge upwards.Impellers mounted directly on the motorshaft extension.Shaft leaktightness by standardized mechanical seal.Hydraulic assembly mounted at 8 pointson a lantern bracket.

    Motor

    Standard ventilated.Extended shaft end.Single-phase motor with integrated thermalprotection, automatic reset.Capacitor incorporated in the terminal box.Guiding rolling bearings of the impeller shaftlubricated for life.

    Speed of rotation : 2900 rpmWindings three-phase : 230-400 VSingle-phase : 230 VFrequency : 50 Hz

    (option 60 Hz)Insulating class : FProtection index : IP 54

    Monobloc pump, compact, economicaland silent.

    Hydraulic assembly in stainless steel:anti-corrosive safety and increasedpump service life.

    Motor rolling bearing fitted in thefront endshield, amply dimensionedand leaktight.

    Suction rings between very thick cells-insensitive to thermal expansion,elimination of risks of seizing up.

    Maximum reliability - high efficiencydue to impeller profile limiting thenumber of stages, shaft size and axialthrust.

    Standardized mechanical seals, +110C maximum, maintenance free.

    Easy installation.

    PUMP IDENTIFICATIONMain parts Materials

    non-aggressive aggressiveliquids liquids

    Body casing 304 st. steel 316L st. steelImpellers 304 st. steel 316L st. steelCells (stage shell) 304 st. steel 316L st. steelPump shaft 316L st. steel 316L st. steelCell centring 304 st. steel 316L st. steelMecanical seal Carbon/ Tungsten carbide/

    Ceramic CarbonOrings EPDM Ethylene Propylene VITONPlugs 316L st. steel 316L st. steelFixing-support bearing Aluminium Aluminium

    * Except MULTi-H1600 series

    NB: 304 stainless steel (X5CrNi18-10) or 316L stainlesssteel (X2CrNiMo17-12) recommended materials offering veryconsiderable resistance to corrosion. Clean, clear, fibrelessliquids conveyed and only slightly loaded in sand/silica(40g/m3 maximum concentration).

    S E - MMULTi-H 206 -

    X V - T

    T : Three-phase motorM : Single-phase motor

    E : EPDMV : VITON

    S : 304 Stainless steelX : 316L Stainless steel

    Nomber of stages

    Niminal flow in m3

    /h

    Pump codeSTAINLESS STEELMULTI-STAGEHORIZONTAL

    Ql/min

    Ql/s

    30

    0.5

    40 50 70 100 150 200 400

    1 1.5 2 3 4

    Imp.gpmHm

    Qm3/h 21 3

    70

    60

    50

    40

    30

    20

    104 5 6 8 10 25

    Hft

    15

    10 15 20 30 40 50

    200

    150

    100

    75

    50

    MULTi-H2 POLE-50 Hz

    MULTi-H400MULTi-H200 MULTi-H1600MULTi-H800

  • 3MULTi-H

    SECTION DRAWING

    MECHANICAL SEAL PARTS LIST

    1111 - Pump casing 1150 - Stage casing with return vane 1154 - Stage centring 1160 - Stage casing without return vane 2250 - Impeller

    2410 - Impeller spacer2460 A - Impeller adjusting washer2460 B - Mechanical seal tapered ring2520 - Impeller back-up ring2540 - Thrower2911 - Shaft end washer

    3011 A - Rolling bearing - fan side 3011 B - Rolling bearing - pump side 3134 - Motor support foot

    3180 - Lantern bracket4213 - Ring casing

    4220 - Rotating part Mechanical 4240 - Stationary part seal 4610 A - Round section joint ring (filling cap) 4610 B - Round section joint ring (draining cap) 4610 C - Round section joint ring (lantern

    casing bracket)

    6515 - Draining cap6521 - Purging and filling cap

    6545 - Circlip (back-up ring)6571 - Motor tie bolt

    8110 - Electric motor casing 9220 - Impeller shaft 9460 - Terminal cover seal 9820 - Fan

    9822 - Fan cover 9825 - Motor terminal cover 9831 - Motor rear bearing 9860 - Capacitor

    9902 A - Lantern casing bracket screw9902 B - Shaft end screw9902 C - Cle aning screw9942 - Fan-type washer9944 - Spring washer9966 - Elastic pin

    () Recommended spare parts

    4240

    1111 6521 4610A 1160 1150 2250 2410 2520 9902A 4610C 4213 9860 9825 9460 3011A 9944 9822 9820 9902C

    9902B 9942 2911 6515 4610B 2460A 1154 6545 2460B 4220 4240 3180 2540 3011B 8110 9220 9966 3134 6571 9831

    POMPE 6 TAGES

    POMPE 4 TAGES

    }4220

    6 STAGE PUMP

    4 STAGE PUMP

  • 4MULTi-H

    HYDRAULIC PERFORMANCE 200 AND 400 SERIES

    1 2 3 4 5 60

    10

    20

    30

    40

    50

    60

    70

    80

    1 2 3 4 5 60

    1020304050

    02468

    1 2 3 4 5 60.0

    0.2

    0.4

    0.6

    0.8

    1.0

    206

    206

    205

    205

    204

    204

    203

    203

    202

    202

    Imp.gpm

    HmMULTi-H200

    2 POLE - 50Hz

    % (205

    )%m

    kW

    Ql/minQl/s

    300.2 0.6

    50 701.1 1.5

    90

    Hft

    200

    150

    100

    50

    6 9 13 17

    NPSH

    Qm3/h

    Qm3/h

    Qm3/h

    NPSH (205)

    1 2 3 4 5 6 7 8 90

    10

    20

    30

    40

    50

    60

    70

    80

    11 22 33 44 55 66 77 88 990

    60

    40

    20

    0

    6

    4

    2

    11 22 33 44 55 66 77 88 990.0

    0.3

    0.6

    0.9

    1.2

    1.5

    HmMULTi-H400

    2 POLE - 50Hz

    Imp.gpm 7 15 22 29

    406

    405

    404

    403

    402

    Qm3/h

    Qm3/h

    Qm3/h

    % (405)

    m

    kW

    % NPSH

    406

    405

    404403402

    Ql/minQl/s

    250.2 0.6

    50 751.1 1.5 1.9 2.3

    100 125

    Hft

    200

    150

    100

    50

    NPSH (405)

    Hydraulic performance at actual speed

  • 5HYDRAULIC PERFORMANCE 800 AND 1600 SERIES

    Imp.gpmHftHm

    Ql/minQl/s

    55MULTi-H800

    2 POLE - 50Hz

    50

    45

    40

    35

    15

    5

    60

    40

    20

    0

    2.0

    1.5

    1.0

    0

    Qm /h3 2 3 4 5

    6

    4

    2

    0

    % m

    805

    NPSH (802)

    % (802)

    805

    804

    803

    802

    30

    25

    20

    10

    0

    180

    160

    140

    120

    100

    20

    40

    60

    80

    6 7 8 9 10 11 12 13 14 15 16

    Qm /h3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    NPSH80

    0.5

    Qm /h3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

    804

    803

    802

    kW

    0

    50403020

    50 100 150 200 2501 2 3 4

    Hydraulic performance at actual speed

    MULTi-H

    Imp.gpmHftHm

    Ql/minQl/s

    55MULTi-H16002 POLE - 50Hz

    50

    45

    40

    35

    15

    5

    60

    40

    20

    0

    2.0

    2.5

    1.5

    0

    Qm /h3 4 8

    6

    4

    2

    0

    % m

    NPSH 1604

    % (1603)

    30

    25

    20

    10

    0

    180

    160

    140

    120

    100

    20

    40

    60

    80

    12 16 20 24 28 32

    4 8 12 16 20 24 28 32

    4 8 12 16 20 24 28 32

    Qm /h3

    NPSH80

    0.5

    1.0

    Qm /h3

    1604

    1603

    1602

    1602

    1603

    1604

    kW

    0

    10080604020

    100 200 300 400 5002 4 6 8

  • 6MULTi-H

    SECTIONAL VIEW OF THE INSTALLATION

    Suction pump

    Strainer foot valve

    Low level

    High level

    min . 0.70m

    0.10m

    Ha

    MIN.

    Strainer

    Town water

    Hc

    On-load pump on storage tank or town waternetwork (with dry running protection kit)

    Maximum suction head (Ha) and minimum pump head(Hc) at nominal pump flow rate.

    Fluid MULTi-H 200 MULTi-H 400/800/1600temperature Ha mCL Hc mCL Ha mCL Hc mCL+ 20C 7 --- 7 ---+ 50C 6 --- 6 ---+ 80C 2.2 --- 3 ---+ 110C --- 8.1 --- 7

    These figures do not take into account load lossesin the suction duct.

  • 7MULTi-H

    ELECTRICAL DATA AND DIMENSIONS

    52

    8.5 7

    L1

    H1

    H2

    L3

    L2

    L

    NDD**

    ND

    S*

    draining 1/4

    filling 1/4

    9

    1 ~

    3 ~

    104

    45

    190

    108

    106

    9

    1 ~

    3 ~

    7 24 24

    H 1

    ph

    .H 3

    ph

    .

    * suction

    ** discharge

    ORDER MOTOR PUMP MassREFERENCE P2 Ports L H H1 L1 L2 L3

    1x 3x 3x Capacitor suction dischargekW 230 V 230 V 400 V F NDA NDR mm mm mm mm mm mm kg

    MULTi-H202-M 0.55 3.8 2.8 1.6 12 G1 G1 375 216 90 205 88 110 09.8MULTi-H202-T 192 08.9

    MULTi-H203-M 0.55 3.8 2.8 1.6 12 G1 G1 375 216 90 205 88 110 09.8MULTi-H203-T 192 08.9

    MULTi-H204-M 0.55 3.8 2.8 1.6 12 G1 G1 423 216 90 253 88 158 10.6MULTi-H204-T 192 09.7

    MULTi-H205-M 0.75 4.8 3.1 1.8 16 G1 G1 423 216 90 253 88 158 12.2MULTi-H205-T 192 11.3

    MULTi-H206-M 1.10 6.3 4.5 2.6 30 G1 G1 472 224 90 277 104 182 15.7MULTi-H206-T 447 192 88 12.9

    MULTi-H402-M 0.55 3.8 2.8 1.6 12 G11/4 G1 375 216 90 205 88 110 09.8MULTi-H402-T 192 08.9

    MULTi-H403-M 0.55 3.8 2.8 1.6 16 G11/4 G1 375 216 90 205 88 110 10.7MULTi-H403-T 192 09.8

    MULTi-H404-M 0.75 4.8 3.1 1.8 16 G11/4 G1 423 216 90 253 88 158 12.2MULTi-H404-T 192 11.3

    MULTi-H405-M 1.10 6.3 4.5 2.6 20 G11/4 G1 448 224 90 253 104 158 15.2MULTi-H405-T 423 192 83 12.9

    MULTi-H406-M 1.50 9.5 6.1 3.5 30 G11/4 G1 472 224 90 277 104 182 17.8.0MULTi-H406-T 472 206 90 104 15.2

    MULTi-H802-M 0.75 4.8 3.1 1.8 16 G11/2 G11/4 387 216 90 217 88 122 15.8MULTi-H802-T 192 10.6

    MULTi-H803-M 1.10 6.3 4.5 2.6 20 G11/2 G11/4 412 224 90 217 104 122 14.5MULTi-H803-T 387 192 88 12.2

    MULTi-H804-M 1.50 9.5 6.1 3.5 40 G11/2 G11/4 224 277 182 16.0MULTi-H804-T 472 206 90 104 15.8

    MULTi-H805-T 1.85 8.0 4.6 G11/2 G11/4 472 206 90 277 104 182 17.0MULTi-H1602-T 1.50 6.6 3.8 G2 G11/2 477 206 90 236 104 138 15.3MULTi-H1603-T 1.85 8.55 4.95 G2 G11/2 477 206 90 236 104 138 17.16MULTi-H1604-T 2.50 10.1 5.85 G2 G11/2 515 221 100 236 137 138 21.1

  • 8MULTi-H

    ACCESSORIES FEATURES

    a) Electrical- T types: Three-phase 230-400 V - 50 Hz- M types: Single-phase 230 V - 50 Hzwith capacitor integrated in terminal box.

    - Motor protection by overload cut-outessential for three-phase motor.

    - Connections to the motor terminalby stuffing-box.

    b) Installation- On the solid base with fixing by foundationbolts.

    - Suction pump assembly with compulsorystrainer foot valve, or on-load pump onstorage tank or on town water networkwith protection system against lack of water.

    - Pump connection through flexible or rigidpiping.

    c) PackagingPump supplied in cardboard packaging,without connection accessories.

    d) MaintenanceReplacement of recommended spare parts() subject to wear and tear.

    Shut-off valves Check valves Strainer foot valve Anti-vibratory sleeves Suction kit Bladder or galvanized tanks Water hammer tanks ME dry running protection kit ACSON: ON/OFF control device and

    protection against lack of water 3-phase overload cut-out motor protection,

    etc.

    Three-phase motor protectionoverload cut-out

    ACSON: ON/OFF control deviceand protection against lack of water

    Strainer foot valve Check valve

    Anti-vibratory sleeves

    Water hammer tank Bladder tank

    Shut-off valve

    OPTIONS & ACCESSORIES

    53 bd de la Rpublique - Espace Lumire - Bt. 6 - 78403 Chatou Cedex FRANCETel: +33 (0) 820 873 624 - Fax: +33 (0)1 30 09 82 34 - www.salmson.com