mpr quick start guide for powering and installation-3db20024caaatnzza ics01
DESCRIPTION
MPR 9500TRANSCRIPT
-
9500 MPR Quick Start Guide MPT-HC-HQAM / XP-HQAM / MC Overview and ODU-to-IDU Connections C
onfig
urat
ion
[1+0
]
[1+1] MPT-HQAM to MSS Electrical
Con
figur
atio
n [1
+1]
Con
figur
atio
n [2
+0] X
PIC
MPT-HC-HQAM with MPT Power Unit - Optical
MPT through power injector plug-in Electrical
[2+0] XPIC MPT-HQAM to MSS Electrical
Coupler 1+1 or 2+0 Copolar
MPT to Power Injector Box - Electrical
RPS LC-LC optical cord
MPT-MC MPT-MC / MPT-HC-HQAM to
MSS Electrical
CAT5e cable data and DC 1AC015760006
MSS-1c
MPTaccess or EASv2 board
CAT5e cable data and DC 1AC015760006
Power injector plug-in 3CC50120AAXX
RJ45 cable data
RJ45 to any switch or router
Power injector box 3CC50129XXXX
48 V DC
CAT5e cable data and DC 1AC015760006
Coaxial Pigtail RJ45/N
Fiber
If PFoE port MSS-1/4/8/1c + Pigtail
MPT-HC-HQAM to MSS Optical
MPT-HC-HQAM to Ethernet device Optical
Option 1 Fiber
MSS
Coaxial cable to station battery with low-pass filter, pigtail, lightning arrestor
Pigtail RJ45/N
Option 2 To any switch or router
RPS LC-LC optical cord 3CC52169XXXX
Note : With MPT-HC-HQAM / MPT-XP-HQAM in 1+1 configuration, when channel spacing is 40, 50, 56 or 60 MHz, the two ODUs must be connected together with an RPS cord (with different lengths available). Optionnal optical SFP modules must be previously inserted.
Coupler 6, 7, 8 and 10,5 / 11 GHz
Coupler 11 to 38 GHz
MSS-1/4/8
Ortho Mode Transducer OMT 6, 7,8 and 10,5 / 11 GHz
[2+0] XPIC MPT-HQAM to MSS Optical
[1+1] MPT-HQAM to MSS Optical
Ortho Mode Transducer OMT 11 to 23 GHz
RPS cord when needed
MPT-HQAM with MPT Extended Power Unit-Electrical
Not valid for MPT-XP-HQAM
Fiber
CAT5e cable data and DC 1AC015760006
RJ45 to any switch or router
MPT-HC-HQAM MPT-XP-HQAM
Optical RPS port
Maintenance port
Optical user port (SFP to be inserted)
Power feed over Ethernet port
XPIC port
MPT-HQAM with MPT Extended Power Unit Optical
Fiber Coaxial
Pigtail RJ45/N
Pigtail RJ45/N
MPT-MC specificities :
- Only RPS protection without cable - XPIC feature not supported - Optical connection not supported
Maintenance port Power feed over Ethernet port
MSS-O
MSS-4/8
If Coax port MSS-4/8
48 V DC
48 V or +24 V DC
48 V or +24 V DC
MPT Access board
No MPTaccess board
Not valid for MPT-XP-HQAM
Pigtail RJ45/N
MPT Powering devices
Max 2 MPT Max 4 MPT
Power unit 3CC50173XXXX
Extended Power unit 3CC50174XXXX Extended Power unit 3CC50174XXXX Max 2 MPT Max 2 MPT
For MPR-e and MPR-1c, if the SW version of the existing network is anterior to R5.0.0, all new or repaired MPT-MC/HC/XP received with a SW Release 5.2.0 must be downgraded to the network SW Release using MCT / TCO R5.0.0. This MCT must be first downloaded from OLCS server to a laptop, where the downgrade can be performed.
QMA connector
N connector
Note: See the applicable MPR user manual for other supported configurations.
CAT5e cable data and DC 1AC015760006
MSS-1/4/8
MPT1 pol V MPT2 pol H
XPIC cord
Note: See the applicable MPR user manual for other supported configurations.
CAT5e cable data and DC 1AC015760006
MSS-1/4/8
XPIC cord
Note: See the applicable MPR user manual for other supported configurations.
Fiber
Coaxial
MSS-1/4/8
XPIC cord
Pigtail RJ45/N
RPS cord when needed
MPT1 pol V MPT2 pol H
Note: See the applicable MPR user manual for other supported configurations.
Fiber Coaxial
MSS-1/4/8
Pigtail RJ45/N XPIC cord
-
2 3 4 Set MPT polarization 5 Install MPT [2+0] with OMT
9500 MPR Quick Start Guide MPT-HC-HQAM / XP-HQAM / MC Installation Steps
Cat5e cable 1AB150990002
Note: MPT toolbox is mandatory 3CC50098AAXX 3.1 Assemble & Install the Integrated antenna . (Refer to antenna instructions) 3.2 Verify the polarization on the antenna and change it if required 3.3 Put silicon grease only if required in the installation instructions of the antenna, see below
1.1
1.1 Install the MSS indoor unit in one of four supported configurations (see the applicable user manual): - ETSI rack (21 in.) -Standard rack (19 in.) - wall mount - Full outdoor, with MSS-O . Refer to dedicated quick start guide 1.2 Ground the MSS using the ground screw on the front panel of the bracket on the right side of the MSS; use grounding kit 3CC13423AAXX. 1.3 Connect the power supply cable between the MSS and breakers or power panel: MSS1 and power injector box: 2x1 mm 1AC007800068 MSS4/8: 2x4 mm 3DB18271AAXX MSS8 (full config): 2x6 mm 3CC52190AAXX 1.4 Install the integrated DDF; (see the applicable manual 75 , 120 , RJ45).
1.3
2.1 Assemble & install the non-integrated antenna. (Refer to antenna instructions) 2.2 Verify the polarization on the antenna and change it if required 2.3 Assemble & install the pole mounting for remote ODU 2.4 Put silicon grease on nose o-ring only if required in the installation instructions.
Factory delivery is in V polarization.
To change the polarization, loosen the two screws and line up the H or V polarization with the polarization references.
WARNING: To avoid equipment damage, do not remove the waterproof tape that is glued on the MPT waveguide.
H
3.4 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 3.5 Open the four locking hooks on the MPT and slide the MPT on the antenna nose adapter. 3.6 Secure the MPT with the four hooks.
5.1 Set the coupler polarization (antenna side) to match the antenna polarization (same process as steps 3.1 to 3.3) WARNING: Verify that the indication engraved on the coupler is directed toward the pole side.
1 Contact Support 11 Perform alignment 11.1 Plug the connector on the maintenance port on the MPT
11.2 Plug the banana plugs into the multi-meter to align the antenna
Line A-A represents azimutht path of a properly aligned antenna.
11.3 Adjust the site & azimuth to the maximum RSL (lobe number 2 (Main lobe)).
Light Service Kit for Alignment 3CC52191AAXX
1 Install MSS unit
Example MPT-HQAM installation with MSS
All Rights Reserved Alcatel-Lucent 2014
Install coupler for MPT [1+1]
9.2 Connect the grounding kit to the ground plate
Example : 11 to 38 GHz
coupler
10.1 For MPT optical connection to MSS, used optical LC-LC preassembled cable 3CC52170XXXX. Different lengths exist. 10.2 Use coaxial cable with N-to-Ethernet pairs pigtails (plus RJ45 and R2CT connectors) for MPT power supply.
Note: This is a guideline for assembling the R2CT with the RJ45 connector for CAT5e cable. For details see Best practice and tips MPR R2CT and RJ45 connector and grounding 3FQ 24013 1100 PCZZA.
8.1 Prepare the R2CT connector, insert the CAT5e cable, and insert the RJ45 plug unlocking clip.
6
H
6.1 Follow the same process described in steps 3.1 and 3.3 . Set the OMT then connect to the antenna. 6.2 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 6.3 Open the four locking hooks on the MPT and slide the MPT on the OMT nose adapter. 6.4 Secure the MPT with the four hooks.
8.2 Mount the RJ45 connector using the RJ45 hirose tool.
R2CT connector 1AB150990002
8.3 Hoist the cable using the buckle on the R2CT cap. 8.4 Connect the assembled R2CT to the MPT, mount another RJ45 plug indoors, and verify all cables and connectors using a cable tester (to avoid short circuit and verify continuity).
8 Assemble and connect electrical connectors
RJ45 connector
RJ45 hirose tool 1AD160490001 or supplier ref: HT601/TM21-88P
Contact support
To access online customer support (OLCS), go to:
http://alcatel-lucent.com/support/ supportredirect.html
For product documentation: On the OLCS page, select Sign In/Register (MyAccess) and then log in to OLCS. For technical support contact information:
On the right side of the OLCS page under Product Technical Support, select your country from the Phone and Email Contact Information drop-down list.
The contact information is displayed.
Service kit cable VDC: 5 4.71 4.12 3.5 2.9 2.3 1.71 1.11 0.59 0.14 RSL (dBm) : -10 -20 -30 -40 -50 -60 -70 -80 -90 -100
Measurement
Assembled R2CT connector
H
Reference polarization H
1.2
9.1 Put one grounding kit : - On top, when it comes on the tower - On bottom, when it leaves the tower - At the entrance of the building Maximum distance between 2 Grounding Kits : 50m Auto-amalgamating tape is recommended. Refer to the 9500MPR User Manual.
5.2 Install and set MPT polarization, for high frequency, turn the MPT polarization disk to be aligned with the coupler waveguide. The connectors must face down.
5.3 for low frequency, turn the whole MPT
5.4 Secure the module with the four hooks on the corresponding brackets.
Install MPT [1+0] on non integrated antenna
REF: 3DB20024CAAATNZZA ICS01
RJ45 connector 1AB074610027
Install MPT [1+0] on integrated antenna
2.5 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 2.6 Open the four locking hooks on the MPT and slide the MPT on the remote nose adapter. 2.7 Secure the MPT with the four hooks.
1.4
Pigtail RJ45/N
Fiber + SFP Coaxial 10
For an explanation, see the step indicated by the numbered circle.
RPS cord when needed
8
7
Connect the MPT grounding connector to the nearest grounding plate, using the ground cable 16mm 3CC08166AAXX. Washer, screw and lug are provided with the MPT.
7 Ground the MPT
Kit for Ethernet cable or coaxial cable ( 6,85) 1AD040130004 Kit for coaxial cable ( 10,3) 1AB128500002
10 Connect optical cables Electrical CAT5e
6.2
9
XPIC cable
9
For MPT ETSI For MPT ANSI
6.1
RPS cable
Ground the indoor Outdoor cable
11.3
11.1 4