mpr quick start guide for powering and installation-3db20024caaatnzza ics01

Upload: rangelbrasil

Post on 06-Mar-2016

498 views

Category:

Documents


64 download

DESCRIPTION

MPR 9500

TRANSCRIPT

  • 9500 MPR Quick Start Guide MPT-HC-HQAM / XP-HQAM / MC Overview and ODU-to-IDU Connections C

    onfig

    urat

    ion

    [1+0

    ]

    [1+1] MPT-HQAM to MSS Electrical

    Con

    figur

    atio

    n [1

    +1]

    Con

    figur

    atio

    n [2

    +0] X

    PIC

    MPT-HC-HQAM with MPT Power Unit - Optical

    MPT through power injector plug-in Electrical

    [2+0] XPIC MPT-HQAM to MSS Electrical

    Coupler 1+1 or 2+0 Copolar

    MPT to Power Injector Box - Electrical

    RPS LC-LC optical cord

    MPT-MC MPT-MC / MPT-HC-HQAM to

    MSS Electrical

    CAT5e cable data and DC 1AC015760006

    MSS-1c

    MPTaccess or EASv2 board

    CAT5e cable data and DC 1AC015760006

    Power injector plug-in 3CC50120AAXX

    RJ45 cable data

    RJ45 to any switch or router

    Power injector box 3CC50129XXXX

    48 V DC

    CAT5e cable data and DC 1AC015760006

    Coaxial Pigtail RJ45/N

    Fiber

    If PFoE port MSS-1/4/8/1c + Pigtail

    MPT-HC-HQAM to MSS Optical

    MPT-HC-HQAM to Ethernet device Optical

    Option 1 Fiber

    MSS

    Coaxial cable to station battery with low-pass filter, pigtail, lightning arrestor

    Pigtail RJ45/N

    Option 2 To any switch or router

    RPS LC-LC optical cord 3CC52169XXXX

    Note : With MPT-HC-HQAM / MPT-XP-HQAM in 1+1 configuration, when channel spacing is 40, 50, 56 or 60 MHz, the two ODUs must be connected together with an RPS cord (with different lengths available). Optionnal optical SFP modules must be previously inserted.

    Coupler 6, 7, 8 and 10,5 / 11 GHz

    Coupler 11 to 38 GHz

    MSS-1/4/8

    Ortho Mode Transducer OMT 6, 7,8 and 10,5 / 11 GHz

    [2+0] XPIC MPT-HQAM to MSS Optical

    [1+1] MPT-HQAM to MSS Optical

    Ortho Mode Transducer OMT 11 to 23 GHz

    RPS cord when needed

    MPT-HQAM with MPT Extended Power Unit-Electrical

    Not valid for MPT-XP-HQAM

    Fiber

    CAT5e cable data and DC 1AC015760006

    RJ45 to any switch or router

    MPT-HC-HQAM MPT-XP-HQAM

    Optical RPS port

    Maintenance port

    Optical user port (SFP to be inserted)

    Power feed over Ethernet port

    XPIC port

    MPT-HQAM with MPT Extended Power Unit Optical

    Fiber Coaxial

    Pigtail RJ45/N

    Pigtail RJ45/N

    MPT-MC specificities :

    - Only RPS protection without cable - XPIC feature not supported - Optical connection not supported

    Maintenance port Power feed over Ethernet port

    MSS-O

    MSS-4/8

    If Coax port MSS-4/8

    48 V DC

    48 V or +24 V DC

    48 V or +24 V DC

    MPT Access board

    No MPTaccess board

    Not valid for MPT-XP-HQAM

    Pigtail RJ45/N

    MPT Powering devices

    Max 2 MPT Max 4 MPT

    Power unit 3CC50173XXXX

    Extended Power unit 3CC50174XXXX Extended Power unit 3CC50174XXXX Max 2 MPT Max 2 MPT

    For MPR-e and MPR-1c, if the SW version of the existing network is anterior to R5.0.0, all new or repaired MPT-MC/HC/XP received with a SW Release 5.2.0 must be downgraded to the network SW Release using MCT / TCO R5.0.0. This MCT must be first downloaded from OLCS server to a laptop, where the downgrade can be performed.

    QMA connector

    N connector

    Note: See the applicable MPR user manual for other supported configurations.

    CAT5e cable data and DC 1AC015760006

    MSS-1/4/8

    MPT1 pol V MPT2 pol H

    XPIC cord

    Note: See the applicable MPR user manual for other supported configurations.

    CAT5e cable data and DC 1AC015760006

    MSS-1/4/8

    XPIC cord

    Note: See the applicable MPR user manual for other supported configurations.

    Fiber

    Coaxial

    MSS-1/4/8

    XPIC cord

    Pigtail RJ45/N

    RPS cord when needed

    MPT1 pol V MPT2 pol H

    Note: See the applicable MPR user manual for other supported configurations.

    Fiber Coaxial

    MSS-1/4/8

    Pigtail RJ45/N XPIC cord

  • 2 3 4 Set MPT polarization 5 Install MPT [2+0] with OMT

    9500 MPR Quick Start Guide MPT-HC-HQAM / XP-HQAM / MC Installation Steps

    Cat5e cable 1AB150990002

    Note: MPT toolbox is mandatory 3CC50098AAXX 3.1 Assemble & Install the Integrated antenna . (Refer to antenna instructions) 3.2 Verify the polarization on the antenna and change it if required 3.3 Put silicon grease only if required in the installation instructions of the antenna, see below

    1.1

    1.1 Install the MSS indoor unit in one of four supported configurations (see the applicable user manual): - ETSI rack (21 in.) -Standard rack (19 in.) - wall mount - Full outdoor, with MSS-O . Refer to dedicated quick start guide 1.2 Ground the MSS using the ground screw on the front panel of the bracket on the right side of the MSS; use grounding kit 3CC13423AAXX. 1.3 Connect the power supply cable between the MSS and breakers or power panel: MSS1 and power injector box: 2x1 mm 1AC007800068 MSS4/8: 2x4 mm 3DB18271AAXX MSS8 (full config): 2x6 mm 3CC52190AAXX 1.4 Install the integrated DDF; (see the applicable manual 75 , 120 , RJ45).

    1.3

    2.1 Assemble & install the non-integrated antenna. (Refer to antenna instructions) 2.2 Verify the polarization on the antenna and change it if required 2.3 Assemble & install the pole mounting for remote ODU 2.4 Put silicon grease on nose o-ring only if required in the installation instructions.

    Factory delivery is in V polarization.

    To change the polarization, loosen the two screws and line up the H or V polarization with the polarization references.

    WARNING: To avoid equipment damage, do not remove the waterproof tape that is glued on the MPT waveguide.

    H

    3.4 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 3.5 Open the four locking hooks on the MPT and slide the MPT on the antenna nose adapter. 3.6 Secure the MPT with the four hooks.

    5.1 Set the coupler polarization (antenna side) to match the antenna polarization (same process as steps 3.1 to 3.3) WARNING: Verify that the indication engraved on the coupler is directed toward the pole side.

    1 Contact Support 11 Perform alignment 11.1 Plug the connector on the maintenance port on the MPT

    11.2 Plug the banana plugs into the multi-meter to align the antenna

    Line A-A represents azimutht path of a properly aligned antenna.

    11.3 Adjust the site & azimuth to the maximum RSL (lobe number 2 (Main lobe)).

    Light Service Kit for Alignment 3CC52191AAXX

    1 Install MSS unit

    Example MPT-HQAM installation with MSS

    All Rights Reserved Alcatel-Lucent 2014

    Install coupler for MPT [1+1]

    9.2 Connect the grounding kit to the ground plate

    Example : 11 to 38 GHz

    coupler

    10.1 For MPT optical connection to MSS, used optical LC-LC preassembled cable 3CC52170XXXX. Different lengths exist. 10.2 Use coaxial cable with N-to-Ethernet pairs pigtails (plus RJ45 and R2CT connectors) for MPT power supply.

    Note: This is a guideline for assembling the R2CT with the RJ45 connector for CAT5e cable. For details see Best practice and tips MPR R2CT and RJ45 connector and grounding 3FQ 24013 1100 PCZZA.

    8.1 Prepare the R2CT connector, insert the CAT5e cable, and insert the RJ45 plug unlocking clip.

    6

    H

    6.1 Follow the same process described in steps 3.1 and 3.3 . Set the OMT then connect to the antenna. 6.2 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 6.3 Open the four locking hooks on the MPT and slide the MPT on the OMT nose adapter. 6.4 Secure the MPT with the four hooks.

    8.2 Mount the RJ45 connector using the RJ45 hirose tool.

    R2CT connector 1AB150990002

    8.3 Hoist the cable using the buckle on the R2CT cap. 8.4 Connect the assembled R2CT to the MPT, mount another RJ45 plug indoors, and verify all cables and connectors using a cable tester (to avoid short circuit and verify continuity).

    8 Assemble and connect electrical connectors

    RJ45 connector

    RJ45 hirose tool 1AD160490001 or supplier ref: HT601/TM21-88P

    Contact support

    To access online customer support (OLCS), go to:

    http://alcatel-lucent.com/support/ supportredirect.html

    For product documentation: On the OLCS page, select Sign In/Register (MyAccess) and then log in to OLCS. For technical support contact information:

    On the right side of the OLCS page under Product Technical Support, select your country from the Phone and Email Contact Information drop-down list.

    The contact information is displayed.

    Service kit cable VDC: 5 4.71 4.12 3.5 2.9 2.3 1.71 1.11 0.59 0.14 RSL (dBm) : -10 -20 -30 -40 -50 -60 -70 -80 -90 -100

    Measurement

    Assembled R2CT connector

    H

    Reference polarization H

    1.2

    9.1 Put one grounding kit : - On top, when it comes on the tower - On bottom, when it leaves the tower - At the entrance of the building Maximum distance between 2 Grounding Kits : 50m Auto-amalgamating tape is recommended. Refer to the 9500MPR User Manual.

    5.2 Install and set MPT polarization, for high frequency, turn the MPT polarization disk to be aligned with the coupler waveguide. The connectors must face down.

    5.3 for low frequency, turn the whole MPT

    5.4 Secure the module with the four hooks on the corresponding brackets.

    Install MPT [1+0] on non integrated antenna

    REF: 3DB20024CAAATNZZA ICS01

    RJ45 connector 1AB074610027

    Install MPT [1+0] on integrated antenna

    2.5 Set the appropriate polarization on the MPT (see step 4); the connectors must face down. 2.6 Open the four locking hooks on the MPT and slide the MPT on the remote nose adapter. 2.7 Secure the MPT with the four hooks.

    1.4

    Pigtail RJ45/N

    Fiber + SFP Coaxial 10

    For an explanation, see the step indicated by the numbered circle.

    RPS cord when needed

    8

    7

    Connect the MPT grounding connector to the nearest grounding plate, using the ground cable 16mm 3CC08166AAXX. Washer, screw and lug are provided with the MPT.

    7 Ground the MPT

    Kit for Ethernet cable or coaxial cable ( 6,85) 1AD040130004 Kit for coaxial cable ( 10,3) 1AB128500002

    10 Connect optical cables Electrical CAT5e

    6.2

    9

    XPIC cable

    9

    For MPT ETSI For MPT ANSI

    6.1

    RPS cable

    Ground the indoor Outdoor cable

    11.3

    11.1 4

    Slide Number 1Slide Number 2