module book final data sheet for websiteaditya series. models pmax (w) ws-320 ws-325 ws-330 ws-335...

2
WS-320 to WS-350 (72 Cells) I-V VARIATION WITH IRRADIANCE I-V VARIATION WITH TEMPERATURE The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications. www.waaree.com Modules binned by current to improve system performance 1500 VDC system voltage for lower BoS cost Superior module efficiency as per international benchmarks PID resistant with long term reliability Sustain heavy wind & snow loads (2400 pa & 5400 pa) Glass with anti reflective coating improves light transmission Salt mist, blowing sand and hail resistant 0 10 20 30 40 Voltage [V] 0 2 4 6 8 10 12 Current [A] 350.5 W Incident Irrad. = 1000 W/m² Cells temp. = 25 °C 279.6 W Incident Irrad. = 800 W/m² 208.2 W Incident Irrad. = 600 W/m² 136.9 W Incident Irrad. = 400 W/m² 66.5 W Incident Irrad. = 200 W/m² 0 10 20 30 40 Voltage [V] 0 2 4 6 8 10 Current [A] Incident Irrad. = 1000 W/m² Cells temp. = 10 °C, Pmpp = 370.8 W Cells temp. = 25 °C, Pmpp = 350.5 W Cells temp. = 40 °C, Pmpp = 330.2 W Cells temp. = 55 °C, Pmpp = 309.8 W Cells temp. = 70 °C, Pmpp = 289.5 W R-72002038 R-72002020 INTERNATIONAL & NATIONAL CERTIFICATIONS IEC 61215:2016 | IEC 61730 1&2:2016 | IEC 61215 ed2 | IEC 61853 | IEC 62782 IEC 61701 | IEC.TS 62804-1 | IEC 62716 | IEC 60068-2-68 | UL 61730 | IS 14286 ISO 9001:2015 l ISO 14001:2015 l ISO 45001:2018 Independent assessment of factories by BLACK & VEATCH ADITYA SERIES

Upload: others

Post on 27-Sep-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Module book final data sheet for WebsiteADITYA SERIES. Models Pmax (W) WS-320 WS-325 WS-330 WS-335 WS-340 WS-345 WS-350 STC NOCT 320 325 330 335 340 345 350 Vmp (V) STC NOCT Imp (A)

WS-320 to WS-350 (72 Cells)

WS09179001025384

I-V VARIATION WITH IRRADIANCE

I-V VARIATION WITH TEMPERATURE

The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications.

www.waaree.com

Modules binnedby current to

improve systemperformance

1500 VDC systemvoltage for

lower BoS cost

Superior moduleefficiency as per

internationalbenchmarks

PID resistantwith long

term reliability

Sustain heavywind & snow loads

(2400 pa & 5400 pa)

Glass with antireflective coating

improves lighttransmission

Salt mist, blowingsand and hail

resistant

0 10 20 30 40

Voltage [V]

0

2

4

6

8

10

12

Cu

rre

nt

[A]

350.5 WIncident Irrad. = 1000 W/m²

Cells temp. = 25 °C

279.6 WIncident Irrad. = 800 W/m²

208.2 WIncident Irrad. = 600 W/m²

136.9 WIncident Irrad. = 400 W/m²

66.5 WIncident Irrad. = 200 W/m²

0 10 20 30 40

Voltage [V]

0

2

4

6

8

10

Cu

rre

nt

[A]

Incident Irrad. = 1000 W/m²

Cells temp. = 10 °C, Pmpp = 370.8 W

Cells temp. = 25 °C, Pmpp = 350.5 W

Cells temp. = 40 °C, Pmpp = 330.2 W

Cells temp. = 55 °C, Pmpp = 309.8 W

Cells temp. = 70 °C, Pmpp = 289.5 W

R-72002038 R-72002020

INTERNATIONAL & NATIONAL CERTIFICATIONSIEC 61215:2016 | IEC 61730 1&2:2016 | IEC 61215 ed2 | IEC 61853 | IEC 62782IEC 61701 | IEC.TS 62804-1 | IEC 62716 | IEC 60068-2-68 | UL 61730 | IS 14286

ISO 9001:2015 l ISO 14001:2015 l ISO 45001:2018Independent assessment of factories by BLACK & VEATCH

ADITYA SERIES

Page 2: Module book final data sheet for WebsiteADITYA SERIES. Models Pmax (W) WS-320 WS-325 WS-330 WS-335 WS-340 WS-345 WS-350 STC NOCT 320 325 330 335 340 345 350 Vmp (V) STC NOCT Imp (A)

ModelsPmax (W)

WS-320

WS-325

WS-330

WS-335

WS-340

WS-345

WS-350

STC NOCT

320

325

330

335

340

345

350

Vmp (V)

STC NOCT

Imp (A)

STC NOCT

Isc (A)

STC NOCT

Voc (V)

STC NOCTModule Eff. (%)

37.65

37.80

37.95

38.10

38.25

38.55

38.90

8.50

8.60

8.70

8.80

8.90

8.95

9.00

9.15

9.20

9.25

9.30

9.35

9.40

9.45

46.50

46.60

46.70

46.80

46.90

47.00

47.10

16.49

16.75

17.01

17.26

17.52

17.78

18.04

www.waaree.com

THERMAL CHARACTERISTICSDESIGN SPECIFICATIONS

Waaree Energies Ltd. is amongst the top Solar Energy Companies and has the country's largest Solar PV Module manufacturing capacity of 2 GW. In addition, it is committed to provide top notch EPC services, project development, rooftop solutions, solar water pumps and also in an Independent Power Producer. Waaree has its presence in over 325+ locations nationally and 68 countries globally.

*If you need specific product certificates, and if module installations are to deviate from our guidance specified in our installation manual, please contact your local Waaree sales and technical representatives.

MECHANICAL CHARACTERISTICS

ELECTRICAL CHARACTERISTICS

Length x Width x Thickness (L x W x T)

Weight

Solar Cells per Module (Units) / Arrangement

Solar Cell Type & Size

Front Glass

Encapsulate

Junction Box (Protection degree / Material)

Connector (Protection degree / Type)

Cable Cross - Section & Length

1960 mm (L) x 990 mm (W) x 40 mm (T)

22.5 kgs

72 / (12x6)

Poly crystalline Silicon, 157 x 157 mm

3.2 mm Low Iron and Tempered glass with ARC coating

PID Free & UV Resistant

IP68 / Weatherproof PPO

IP68 rated / MC4 compatible

24 mm & 1200mm

Temperature coefficient of Current (Isc), α (%/ºC)

Temperature coefficient of Voltage (Voc), ß (%/ºC)

Temperature coefficient of Power (Pm), γ (%/ºC)

NOCT (ºC)

Operating temperature range (ºC)

0.051

-0.2775

-0.3859

46 + 2

-40 to 85

WS-320 to WS-350 (72 Cells)

10 Years Product Warranty* • Power Output Warranty**25 Years Minimum 90% at the end of 10 years • Minimum 80% at the end of 25 years

235.19

238.80

242.42

246.12

249.07

252.50

256.70

34.59

34.86

35.03

35.28

35.53

35.72

36.02

6.80

6.85

6.92

6.98

7.01

7.07

7.12

7.33

7.37

7.42

7.47

7.51

7.55

7.57

43.18

43.26

43.26

43.34

43.39

43.47

43.66

• The electrical data given here is for reference purpose only.• Please confirm your exact requirements with the sales representative while placing your order.• Refer installation Manual instructions & Waaree warranty statement for terms & conditions.• Waaree Reserves the right to change the specifications without prior notice.

*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.

System Voltage Series Fuse Rating1500 V 16 A

ADITYA SERIES

WEL/E&PD/320-350/72/B/P/F/00/09.04.2020

40 mm4 - Drainage Slots

1200

mm

JunctionBox

-Negative ( ) (+) Positive

1960

mm

1060

mm

+ 1

4 - (12x8)Mounting hole

2 No’s - Φ4.00Grounding hole

942 + 1 mm

990 mm