mode

10
MODE FABRICA giroform system giroform pin drill giroform baseplates C | 23 SYSTEM COMPONENTS C|24 C|28 C|29 ® ® ®

Upload: arissa

Post on 24-Feb-2016

59 views

Category:

Documents


0 download

DESCRIPTION

SYSTEM COMPONENTS. MODE. FABRICATIO. giro form system. ® ® ®. C|24 C|28 C|29. giro form pin drill. giro form baseplates. C | 23. SYSTEM D CO ES MC PR OIN PE TN IO TN S. giro form system. ®. The Giroform system outsmarts the plaster. ®. expansion and is simple, fast and precise. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: MODE

MODE

FABRICATIOgiroform systemgiroform pin drillgiroform baseplates

C | 23

SYSTEM COMPONENTS

C|24C|28C|29

®

®

®

Page 2: MODE

giroform systemThe Giroform system outsmarts the plaster

Giroform outsmarts the plaster expansion of the jaw segment, thus providing a true

The Giroform System provides dental technology with a perfect and high-precision

procedures Giroform guarantees permanent and reproducible quality.

C | 24

SYSTEM D CO ES MC PR OIN PE TN IO TN S

The fitting accuracy of dental prostheses is largely dependent on the precision of themodels. Yet this is the very area in which the natural expansion of the plaster consti-tutes the greatest source of error. The effects of plaster expansion are evident in thepatient’s mouth in problems with the fit of prosthetic work, such as tension areas.

®

model of the patient’s mouth.®

model making system on the market. By employing standardized and optimized®

Saves time, saves material.Simple procedures and maximum precision.

®

expansion and is simple, fast and precise

®

Page 3: MODE

How does Giroform solve

Giroform Plate.

Giroform Plate.stored. The Giroform Base Plate

C | 25

After sawing or separating thetooth arch, the pins again fit intothe drill-holes.The cut section serves as anexpansion joint to accommodatethe expansion, which is nowrestricted to just the individualsegments, thus no longer caus-ing distortion of the tooth arch.The segmented model thereforeoffers a precision basis for per-fectly-fitting work.

The pin positions are chosentaking this cast into account.By drilling the pin-holes, thereis secure and immovablepatient-analogous transferto the dimensionally-stable

®

The pin-holes ensure that thepositional information is now

®

serves as a kind of memory stick.

The cast plaster tooth arch isremoved from the base plateafter 30 minutes – i.e. before theonset of plaster expansion.This allows the tooth arch toexpand freely. However, after thisit no longer matches the drilledoriginal information on the

®

1 2 3

4 5 6

SYSTEM D CO ES MC PR OIN PE TN IO TN S

®

Precise, simpleand fast

The patient’s original mouthposition.

The tooth arch following plasterexpansion.

By superimposing the originaland the expanded tooth arch,the deviation is clearly shown.

Undesirable plasterexpansion in making themodel

®

this challenge?Defeat expansion

®

sions from prosthetic work

Page 4: MODE

Giroform model Giroform model

SYSTEM D CO ES MC PR OIN PE TN IO TN S

®

Waiting time

Working time

20

10

0

40

30

25

6,5®

8Classic model

with pin & sleevesystem

50

58,0Minutes

60

50

31,5

Retention disc/metal plate

Dental arch plaster(65g/90g)

Pins (14pcs)/pinswith sleeve (14pcs)

Base plate/base plaster(150g)

retentiondisc

80%

60%

40%

20%

0%

120%

100%

140%

31%

19%

38%

®

with

12%Adhesive

with other models +131%

magnet andretention disc

magnet andretention disc

+98%18%

43%

115% 115%

21% 21%Classic pin andsleeve model

w/o with

33%

18%

43%

220%

200%

180%

160%

_The actual time required to make the model is just 6 – 7 minutes_The base is manufactured_The model can be worked on after only 40 minutes

_The amount of plaster needed is reduced due to blocking out theimpression with Giroform putty

_The metal disc is already fixed into the premium base plate_Multiple use of base plates, secondary plates and metal discs_Base plaster no longer required_The base plate is cheaper than the base plaster_No adhesives, guide sleeves or shell moulds required

C | 26

The system whichsaves double the time

Double time saving

The system thatsaves time and material

Comparing Giroform® model (100% cost)

Page 5: MODE

Giroform pin drill

SYSTEM D CO ES MC PR OIN PE TN IO TN S

®

Precision, economy, speed

® Pins

Duplication flask

Base collar

Base plates

Secondary plates

Quadrant plates

SYSTEM COMPONENTS

YOUR + POINTS AT A GLANCE

+ Precise_Plaster expansion eliminated thanks to individually drilled based plateand segmentation of dental arch

_Segments reset in correctly drilled position free of expansion

+ Fast_Model made in just six minutes_ The base is ready with the base plate

+ Cost-effective_Less plaster required for the dental arch, no plaster required for the base_The entire base plate is less expensive than the corresponding amount of base plaster_Base plates, secondary plates and metal discs suitable for multiple use

+ Universal_Can be used for saw-cut master models, opposite models, two-partmodels, anatomical casts, diagnostic models and partial impressions

+ Simple_Simple procedures_Entire system user-friendly with ergonomic design

C | 27

Page 6: MODE

C | 28

Strong, practical and aesthetic –stainless steel housing

Laser beam for easy drillpositioning

Plate holder is secured magneticallyand automatically when drilling starts

SYSTEM COMPONENTS

®

Perfectly formed, quality appearance,unbeatable performanceThe pin drill allows precise, fastand safe determination of thedesired drill position.Drilling starts at the press of abutton. The plate holder is fas-tened magnetically, securingthe drill position.In order to guarantee pin fric-tion, identical, smooth-facedand regular holes are drilled

®

The precise drill guide also ena-bles uniform drilling depth.These specific characteristics

®

antee precise, fast and cost-ef-fective model manufacture.

_Fast and easy to use_Laser beam for easy drill positioning_Plate holder smoothly adjustable thus ensuring safe and fast operation_Plate holder is secured magnetically and automatically when drilling starts_Semi-automatic drilling at the press of a button (0.5 seconds per hole)_Automatic drill advance guarantees identical boreholes in the plates_Robust device providing many years of reliability

Page 7: MODE

X- X-la r la rge ge

Using the Giroform base platemeans that the model isalready half finished. The baseplate is expansion-resistant,saves one working step andprevents plaster expansion.Prior to using the plaster, thepinhole is set into the baseplate, recording the position ofthe individual segment.The high-precision homoge-nous plate material providesfor smooth drill holes and guar-antees precise pin guidance.The flat surface of the baseplate enables simple control ofthe segment position via aneasily recognizable light gap.Cost-effectiveness is furtherincreased by the possibility tore-use the base plate and theretention disc.

Individual segments checked at aglance. Plane surface of the baseplate

Multiple use of used, drilled baseplates for opposite models and thefixed metal discs as retention discsfor anatomical casts. Reusable baseplate and metal plate

C | 29

Slanting facilitates insertion in drillplate holder and removal from articu-lator – inclined plane on rear of plate

Multiple-use of premium plates foropposite models and classic plates

three drill holes for pin fixingif working without a metal disc

Split cast checkedfor scientificallyverified geometrytriangular split castwith wedge tapering

to centre

incl. metal discs

_Using the Giroform base plate means that the model is already half finished._Inherently stable base plate instead of the risk of secondary plaster expansiondue to base plaster

_Plate material and the plate strength provide for precise pin guidance_Only minimal amounts of dental arch plaster required_Metal disk and screw are re-usable, instead of using expensive special M8 screws_Flat base plate surface enables individual segment monitoring at a glance_Inclined rear surface facilitates insertion in the plate holder and model removal fromthe articulator

_Base plate can be re-used for opposing model.

Saves working time (base plaster, sleeves andmoulds). Base plate ready-to-use and available inthree sizes• L for standard cases• XL for exceptionally large arches• Quadrant for sectional impressions

quadrantquadrant

largelarge

Cost savingslow-priced reusable metaldiscs for classic base plates

Screw fitting no longerrequired saving timepremium base plates

SYSTEM COMPONENTS

®

Limits the amount of work, base plaster,sleeves and bases thus minimizing costs

Page 8: MODE

giroform secondary plate

giroform quadrant plate

_The Vertex adapter enables direct connection to Vertex

giroform pins

® ®

articulators

_Also adaptable with the Orbix system with minor alteration

_Precision brass pin_With smooth finish on tapered section for accurate fitin base plate hole

_With active retention area for perfect grip in dental arch plaster_Reasonably priced

C | 30

Precise and economically priced

Stability and comfort

_Split cast check enables passive (non-magnetic) precisionfit to the base plate

_The balanced magnetic force and high material strengthprevent deformation

_The retention pattern on the rear has been optimized to provideexcellent grip for the plaster during insertion in the articulatorbut also its easy removal after use

Straightforward and versatile

_The standardized plate size is ideally suited to partialimpressions - both left or right quadrant casts. No moretrimming or grinding required

_Drill holes for pins can be positioned at underside and will therebyfacilitating insertion, casting and removal from the articulator

SYSTEM COMPONENTS

®

Precision, cost-effectiveness and speed

_A combination of carefully matched system components ensures the success of the final product_The following system components play an important part in saving time and plaster while providing a high degree of accuracy

®

®

®

Page 9: MODE

giroform putty

giroform dublication flask

giroform base collar

_Used Giroform Base Plates which have already been drilled

C | 31

SYSTEM COMPONENTS

Economic and re-usable

_Permanently applicable soft silicone putty for placingand blocking out the cast on the impression tray._Saves time with rapid blocking-out_Saves plaster and therefore increases the cost-effectiveness_No subsequent trimming or grinding required_Reusable

Versatile and durable

_Universal solution for individual refractory dies, severalsegments or entire dental arch

_Ceramic firing pins allow duplicate casts to be made withrefractory investment

_Saves refractory investment and duplicating silicone byreducing duplication area

_The extension of the labial area also allows duplication ofprotrusive anterior teeth

Clever and functional

_The vestibular extension allows incorporation of mucobuccalfolds and soft tissue on partial prostheses or full dentures

®

can be used to make master casts

®

®

®

Page 10: MODE

C | 32