mobile gate - eatonpub/@eaton/@hyd/... · mobile gate eaton mobile-gate™ breather assemblies...

2
Mobile Gate Eaton Mobile-gate™ Breather Assemblies provide low cost, high efficiency protection against airborne moisture and particulate contamination. Patented technology elimi- nates moisture condensation in hydraulic system reser- voirs. Moisture is prevented from entering and is actually “pumped” out with each flow cycle. The media regen- erates its water holding capacity with every oil return phase, ensuring long service life. Mobile-gate™ reservoir breather filters out particles and moisture before it contami- nates the oil. Hydraulic reser- voirs “breathe” air in and out as the oil level rises and falls. This air contains particles and water. Particles “sand blast” your machinery and water attacks your oil and compo- nents. The Mobile-gate reser- voir breather filters out parti- cles and moisture. Protect your hydraulic system with a filter. Features/Benefits: Proprietary Media: Reduces dew point temperature to prevent condensation and is 99.7% efficient in blocking particles 10μ and larger. Water Regeneration: Regenerates its water holding capacity with each cycle. Reversible Flow Through Media: Allows for moisture to exit the reservoir. Easy Installation: Lightweight design; only needs to be hand tightened. Rugged Housing: Protects the media from external splashing. Filler Breather Assemblies MBR110 Part Number: 5002486 MBR120 Part Number: 5002487 PART NUMBER FLOW DIMENSIONS (in) gpm lpm D1 D2 D3 D4 H1 H2 T1 MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4 MBR120 125 475 3.08 1.88 0.25 2.81 2.50 3.50 - SPECIFICATIONS D1 H1 H2 T1 D3 D4 H1 H2 D2 D1

Upload: ngotuyen

Post on 01-Apr-2018

221 views

Category:

Documents


5 download

TRANSCRIPT

Mobile Gate

Eaton Mobile-gate™Breather Assemblies provide low cost, high efficiency protection againstairborne moisture and particulate contamination.Patented technology elimi-nates moisture condensationin hydraulic system reser-voirs. Moisture is preventedfrom entering and is actually“pumped” out with eachflow cycle. The media regen-erates its water holdingcapacity with every oil returnphase, ensuring long servicelife.

Mobile-gate™ reservoirbreather filters out particlesand moisture before it contami-nates the oil. Hydraulic reser-voirs “breathe” air in and outas the oil level rises and falls.This air contains particles andwater. Particles “sand blast”your machinery and waterattacks your oil and compo-nents. The Mobile-gate reser-voir breather filters out parti-cles and moisture. Protectyour hydraulic system with afilter.

Features/Benefits:• Proprietary Media:

Reduces dew point temperature to preventcondensation and is 99.7%efficient in blocking particles10µ and larger.

• Water Regeneration:Regenerates its water holding capacity with eachcycle.

• Reversible Flow ThroughMedia: Allows for moistureto exit the reservoir.

• Easy Installation:Lightweight design; onlyneeds to be hand tightened.

• Rugged Housing: Protectsthe media from externalsplashing.

Filler Breather Assemblies

MBR110

Part Number: 5002486

MBR120

Part Number: 5002487

PART NUMBER FLOW DIMENSIONS (in)

gpm lpm D1 D2 D3 D4 H1 H2 T1

MBR110 125 475 3.08 - - 2.33 0.63 NPT 3/4MBR120 125 475 3.08 1.88 0.25 2.81 2.50 3.50 -

SPECIFICATIONS

D1

H1

H2T1

D3

D4

H1

H2

D2

D1

Eaton14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952 937-9800Fax: 952 974-7722www.hydraulics.eaton.com

EatonEaton Fluid Power GmbHDr.-Reckeweg-Str. 1D-76532 Baden-Baden, GermanyTel: +49 (0) 7221 682-0Fax: +49 (0) 7221 682-788

Eaton20 Rosamond RoadFootscrayVictoria 3011AustraliaTel: (61) 3 9319 8222Fax: (61) 3 9318 5714

Inha

latio

n

Exhalation

Part Numbers:

NPT Mobile-gate MBR110Flange Mobile-gate MBR120

Performs as a gateDuring the “inhalation” cycle,the Mobile-gate proprietarymedia blocks the water vaporfrom entering the reservoir.During the “exhalation”cycle, the media allows themoisture in the reservoir airto exit. The moisture is car-ried off the media by theexiting air, restoring themedia’s water barrier capaci-ty, and the moisture barriermechanism is not affected bythe amount of exposure tomoisture. The reservoir air is maintained at a low relative humidity, and moreimportantly, at a lower dewpoint temperature than theambient temperature.

Works even when the system is shut down.The Mobile-gate VentBreather retards the vaporequilibrium process andworks to prevent condensa-tion even after the system isshut and cooled down, suchas overnight. As this chartillustrates, the dewpoint isslow to climb, even after thesystem temperature hasdropped to the ambient tem-perature. Once the systemhas reached ambient temper-ature, condensation does not occur.

Reduces humidity insidereservoir.The Mobile-gate VentBreather lowers and stabilizesthe relative humidity of airinside the reservoir, leading toa lower dewpoint (Tdewpoint< Tambient = NO CONDEN-SATION) at a rate and amountthat will be dependent uponseveral conditions: the ambi-ent conditions, the internalreservoir heat, amount andfrequency of reservoir air flowthrough the vent, and thetemperature of the reservoirsurfaces.

© 2004 Eaton CorporationAll Rights Reserved Printed in USADocument No. V-FIFI-MS003-E November 2004