Mobile EKG Sensor Senior Design May0530 ABSTRACT PROJECT REQUIREMENTS The goal of this project is to develop a method of collecting heart rates using Vernier’s EKG sensor with the NI Mobile DAQ. The Mobile DAQ must then communicate with a PDA using the Bluetooth protocol. The data from the sensor will be displayed in a LabVIEW module. INTRODUCTION Problem Statement: Heart rates have always been measured with ECG/EKG equipment that are stationary in medical institutions. It would be of great service to the public if there is a device that would provide similar performance but is portable. Since most medical problems occur away from health institutions, such a device would be beneficial for many situations. Intended Users and Uses: This module has several different applications and could be used by many people. Some possible users are paramedics, lifeguards, or even teachers. It will be used to collect heart rates and produce real time graphs of such data. It will also have its own algorithms to process EKG data. Assumptions: •The PDA interface will be clear and easy to use. •All necessary EKG data will be displayed in the PDA interface. •The manual will explain the proper use of the sensor and the PDA interface. •The Mobile DAQ is powered by two AA batteries. Limitations: •The Mobile DAQ must stay within Bluetooth range of the PDA. •Device is not reliable for use in serious medical operations. •User must be able to run LabVIEW module on their PDA. •Devices cannot operate outside of the temperature range 0˚ to 50˚ C. Expected End Product: The final product will include the LabVIEW module to display the EKG data as well as the EKG sensor, Mobile DAQ, and all connectivity accessories. Also included will be an in-depth manual on how to use the sensor and the LabVIEW module. Design Objective: •Ensure the EKG sensor can take complete and accurate data •Ensure the MobileDAQ can read in the EKG sensor’s data •Ensure the MobileDAQ can communicate with the PDA •Ensure the MobileDAQ can communicate with the PalmOS •Ensure the PDA and PalmOS can receive the data •Ensure the modules created will put the EKG data into graphical form •Ensure the manual is complete and easy to read Functional Requirements: Display Data: The data taken by the EKG sensor should have the capabilities of being displayed graphically on either a Bluetooth PalmOS PDA or a PocketPC 2003 PDA. Portable: The collective end product including the EKG sensor, MobileDAQ, PDA, and laptop should all be portable and functional in any location. Accurate: The end product should be able to take data which is accurate when measuring someone’s heart rate. Communicate Wirelessly: The MobileDAQ should be able to communicate wirelessly (through Bluetooth) with the Bluetooth enable PalmOS PDA or PocketPC 2003 PDA. Constraints Considerations: Distance: A Bluetooth equipped device can only communicate wirelessly with another Bluetooth equipped device if the 2 devices are within a certain range of each other. We will define the end product demonstration maximum range between the MobileDAQ and the PDA to be 10 feet. APPROACH AND CONSIDERATIONS Technology considerations: LabVIEW: LabVIEW is to be used for the algorithms used in processing the data. There are several different versions of LabVIEW, which may have a small effect on the programming section. PDA vs. Laptop: The MobileDAQ can connect wirelessly to either a Bluetooth enabled PDA or a Bluetooth enable laptop. We will look at which is readily available for us to use and test with, which is cheaper, and if either has any certain limiting capabilities. Testing requirements considerations: Location: The location of where we are placing the EKG sensors on the body while doing our testing could affect how the EKG sensor reads the data. As long as the location is kept constant through the testing process, this should not be a problem. Consistency: The data from the EKG sensor needs to work with both the Bluetooth enabled Desktop/Laptop and the PalmOS or PocketPC 2003 PDA. Length of test: We must decide how long we wish to record the data using the EKG sensor. We must also decide what length of time is appropriate. Other Resources Items Cost Hardware: Bluetooth Enabled PocketPC $399/Donated PalmOS PDA $399/Donated EKG Sensor $149/Donated Mobile DAQ N/A/Donated Software: PocketPC 2003 Inc./Donated PalmOS Inc./Donated LabVIEW FDS ISU/Donated LabVIEW PDA Inc./Donated Other: Poster and Printing $50 Total $50 Client: National Instruments Corp. Marius Ghercioiu [email protected] om Faculty Advisor: Professor Morris Chang Dept. of Electrical & Computer Eng. [email protected] Matt Goedken Electrical Engineering [email protected] Dan Hyndman Computer Engineering [email protected] Amber Vo Electrical Engineering [email protected] Duc Vu Electrical Engineering [email protected] RESOURCES SCHEDULE Team EffortC hart 0 10 20 30 40 50 60 70 80 D uc V u D an H yndm an M attGoedken Am berVo Hours Task 1 Task 2 Task 3 Task #1: Documentation and Planning Task #2: Research Task #3: Development PROJECT INFORMATION SUMMARY This project will prove to be an interesting and challenging task. Successful completion of the project will allow many institutions with low budget to take EKG measurements. Along with a successful end product, members of the team will learn invaluable information regarding LabVIEW development, the Bluetooth protocol, graphing techniques and efficient data processing algorithms. Team Members:

Upload: giles-wells

Post on 29-Jan-2016

214 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Mobile EKG Sensor Senior Design May0530 ABSTRACT PROJECT REQUIREMENTS The goal of this project is to develop a method of collecting heart rates using Vernier’s

Mobile EKG SensorSenior Design May0530

ABSTRACT

PROJECT REQUIREMENTS

The goal of this project is to develop a method of collecting heart rates using Vernier’s EKG sensor with the NI Mobile DAQ. The Mobile DAQ must

then communicate with a PDA using the Bluetooth protocol. The data from the sensor will be displayed in a LabVIEW module.

INTRODUCTION

Problem Statement:Heart rates have always been measured with ECG/EKG equipment that are stationary in medical institutions. It would be of great service to the public if there is a device that would provide similar performance but is portable. Since most medical problems occur away from health institutions, such a device would be beneficial for many situations.

Intended Users and Uses:This module has several different applications and could be used by many people. Some possible users are paramedics, lifeguards, or even teachers. It will be used to collect heart rates and produce real time graphs of such data. It will also have its own algorithms to process EKG data.

Assumptions:•The PDA interface will be clear and easy to use.•All necessary EKG data will be displayed in the PDA interface.•The manual will explain the proper use of the sensor and the PDA interface.•The Mobile DAQ is powered by two AA batteries.

Limitations:•The Mobile DAQ must stay within Bluetooth range of the PDA.•Device is not reliable for use in serious medical operations.•User must be able to run LabVIEW module on their PDA.•Devices cannot operate outside of the temperature range 0˚ to 50˚ C.

Expected End Product:The final product will include the LabVIEW module to display the EKG data as well as the EKG sensor, Mobile DAQ, and all connectivity accessories. Also included will be an in-depth manual on how to use the sensor and the LabVIEW module.

Design Objective:•Ensure the EKG sensor can take complete and accurate data•Ensure the MobileDAQ can read in the EKG sensor’s data•Ensure the MobileDAQ can communicate with the PDA•Ensure the MobileDAQ can communicate with the PalmOS•Ensure the PDA and PalmOS can receive the data•Ensure the modules created will put the EKG data into graphical form•Ensure the manual is complete and easy to read

Functional Requirements:Display Data:

The data taken by the EKG sensor should have the capabilities of being displayed graphically on either a Bluetooth PalmOS PDA or a PocketPC 2003 PDA.

Portable:The collective end product including the EKG sensor, MobileDAQ, PDA, and laptop should all be portable and functional in any location.

Accurate:The end product should be able to take data which is accurate when measuring someone’s heart rate.

Communicate Wirelessly:The MobileDAQ should be able to communicate wirelessly (through Bluetooth) with the Bluetooth enable PalmOS PDA or PocketPC 2003 PDA.

Constraints Considerations:Distance:

A Bluetooth equipped device can only communicate wirelessly with another Bluetooth equipped device if the 2 devices are within a certain range of each other. We will define the end product demonstration maximum range between the MobileDAQ and the PDA to be 10 feet.

APPROACH AND CONSIDERATIONS

Technology considerations:LabVIEW:

LabVIEW is to be used for the algorithms used in processing the data. There

are several different versions of LabVIEW, which may have a small effect on

the programming section.PDA vs. Laptop:

The MobileDAQ can connect wirelessly to either a Bluetooth enabled PDA or a

Bluetooth enable laptop. We will look at which is readily available for us to use

and test with, which is cheaper, and if either has any certain limiting capabilities.

Testing requirements considerations:Location:

The location of where we are placing the EKG sensors on the body while

doing our testing could affect how the EKG sensor reads the data. As long

as the location is kept constant through the testing process, this should not be

a problem.Consistency:

The data from the EKG sensor needs to work with both the Bluetooth enabled

Desktop/Laptop and the PalmOS or PocketPC 2003 PDA.Length of test:

We must decide how long we wish to record the data using the EKG sensor.

We must also decide what length of time is appropriate.

Other Resources

Items Cost

Hardware:

Bluetooth Enabled PocketPC $399/Donated

PalmOS PDA $399/Donated

EKG Sensor $149/Donated

Mobile DAQ N/A/Donated

Software:

PocketPC 2003 Inc./Donated

PalmOS Inc./Donated

LabVIEW FDS ISU/Donated

LabVIEW PDA Inc./Donated

Other:

Poster and Printing $50

Total $50

Client:National Instruments Corp.Marius Ghercioiu [email protected]

Faculty Advisor:Professor Morris ChangDept. of Electrical & Computer Eng. [email protected]

Matt GoedkenElectrical [email protected]

Dan HyndmanComputer [email protected]

Amber VoElectrical [email protected]

Duc VuElectrical [email protected]

RESOURCES SCHEDULE

Team Effort Chart

0

10

20

30

40

50

60

70

80

Duc Vu Dan Hyndman Matt Goedken Amber Vo

Ho

urs

Task 1

Task 2

Task 3

Task #1: Documentation and PlanningTask #2: ResearchTask #3: Development

PROJECT INFORMATION

SUMMARY

This project will prove to be an interesting and challenging task. Successful completion of the project will allow many institutions with low budget to take EKG measurements. Along with a successful end product, members of the team will learn invaluable information regarding LabVIEW development, the Bluetooth protocol, graphing techniques and efficient data processing algorithms.