Page 1 © 2013 Lennox Industries Inc. ML180DF(X) Service Literature Corp. 1219-L4 Revised 02/2013 ML180DF series units are mid-efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralokt heat exchangers formed of aluminized steel. ML180DF units are available in heating capacities of 44,000 to 110,000 Btuh and cooling applications 1.5 to 5 tons. Refer to Product Specifications bulletin for proper siz- ing. Units are factory equipped for use with natural gas. Kits are available for conversion to LP/Propane operation. ML180DF model units are equipped with a hot surface igni- tion system. All units use a redundant gas valve to assure safety shut-off as required by C.S.A. All specifications in this manual are subject to change. Pro- cedures outlined in this manual are presented as a recom- mendation only and do not supersede or replace local or state codes. In the absence of local or state codes, the guidelines and procedures outlined in this manual (except where noted) are recommended only and do not constitute code. TABLE OF CONTENTS Specifications Page 2 ............................. Blower Data Page 4 .............................. Parts Identification Page 5 ......................... I Unit Components Page 6 ........................ II Installation Page 14 ............................. III Start Up Page 14 .............................. IV Heating System Service Checks Page 14 ......... V Typical Operating Characteristics Page 19 ......... VI Maintenance Page 19 .......................... VII Wiring and Sequence of Operation Page 22 ...... VIII Twinning Page 27 ............................. IMPORTANT Improper installation, adjustment, alteration, service or maintenance can cause property damage, person- al injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING Electric shock hazard. Can cause injury or death. Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at discon- nect switch(es). Unit may have multiple power supplies. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury.

Upload: others

Post on 11-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ML180DF(X) - Dominion Energy

Page 1 © 2013 Lennox Industries Inc.

ML180DF(X)Service Literature

Corp. 1219-L4Revised 02/2013

ML180DF series units are mid-efficiency gas furnaces

used for downflow applications only, manufactured with

Lennox Duralok� heat exchangers formed of aluminized

steel. ML180DF units are available in heating capacities of

44,000 to 110,000 Btuh and cooling applications 1.5 to 5

tons. Refer to Product Specifications bulletin for proper siz­

ing.

Units are factory equipped for use with natural gas. Kits are

available for conversion to LP/Propane operation.

ML180DF model units are equipped with a hot surface igni­

tion system. All units use a redundant gas valve to assure

safety shut-off as required by C.S.A.

All specifications in this manual are subject to change. Pro­

cedures outlined in this manual are presented as a recom­

mendation only and do not supersede or replace local or

state codes. In the absence of local or state codes, the

guidelines and procedures outlined in this manual (except

where noted) are recommended only and do not constitute

code.

TABLE OF CONTENTS

Specifications Page 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Blower Data Page 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Identification Page 5. . . . . . . . . . . . . . . . . . . . . . . . .

I Unit Components Page 6. . . . . . . . . . . . . . . . . . . . . . . .

II Installation Page 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

III Start Up Page 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IV Heating System Service Checks Page 14. . . . . . . . .

V Typical Operating Characteristics Page 19. . . . . . . . .

VI Maintenance Page 19. . . . . . . . . . . . . . . . . . . . . . . . . .

VII Wiring and Sequence of Operation Page 22. . . . . .

VIII Twinning Page 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IMPORTANTImproper installation, adjustment, alteration, serviceor maintenance can cause property damage, person­al injury or loss of life. Installation and service mustbe performed by a qualified installer, service agencyor the gas supplier.

WARNINGElectric shock hazard. Can cause injuryor death. Before attempting to performany service or maintenance, turn theelectrical power to unit OFF at discon­nect switch(es). Unit may have multiplepower supplies.

WARNINGSharp edges.Be careful when servicing unit to avoid sharp edgeswhich may result in personal injury.

Page 2: ML180DF(X) - Dominion Energy

Page 2

SPECIFICATIONSGas Heating Performance

Model No. Model No. - Low NOx

ML180DF045P24A - - -

ML180DF045P36A - - -

ML180DF070P36A ML180DF070XP36A

1 AFUE 80% 80% 80%Input - Btuh 44,000 44,000 66,000

Output - Btuh 35,000 36,000 53,000Temperature rise range - °F 25 - 55 15 - 45 25 - 55

Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane

3.5 / 10.0 3.5 / 10.0 3.5 / 10.0

High Static - in. w.g. 0.50 0.50 0.50Connections in.

Flue connection - in. round 4 4 4Gas pipe size IPS 1/2 1/2 1/2

Indoor Blower

Wheel nom. dia. x width - in. 10 x 7 10 x 8 10 x 8Motor output - hp 1/5 1/3 1/3

Tons of add-on cooling 1.5 - 2 2 - 3 2 - 3Air Volume Range - cfm 401 - 1157 739 - 1524 717 - 1562

Electrical Data

Voltage 120 volts - 60 hertz - 1 phaseBlower motor full load amps 3.1 6.1 6.1

Maximum overcurrent protection 15 15 15Shipping Data lbs. - 1 package 105 113 128NOTE - Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.

SPECIFICATIONSGas Heating Performance

Model No. Model No. - Low NOx

ML180DF090P36B - - -

ML180DF090P48B ML180DF090XP48B

ML180DF110P60C ML180DF110XP60C

1 AFUE 80% 80% 80%Input - Btuh 88,000 88,000 110,000

Output - Btuh 71,000 71,000 89,000Temperature rise range - °F 35 - 65 25 - 55 30 - 60

Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane

3.5 / 10.0 3.5 / 10.0 3.5 / 10.0

High Static - in. w.g. 0.50 0.50 0.50Connections in.

Flue connection - in. round 4 4 4Gas pipe size IPS 1/2 1/2 1/2

Indoor Blower

Wheel nom. dia. x width - in. 10 x 9 10 x 10 11-1/2 x 10Motor output - hp 1/3 1/2 1

Tons of add-on cooling 2 - 3 3 - 4 4 - 5Air Volume Range - cfm 743 -1695 917 - 1929 1517 - 2760

Electrical Data

Voltage 120 volts - 60 hertz - 1 phaseBlower motor full load amps 6.1 8.2 10.0

Maximum overcurrent protection 15 15 15Shipping Data lbs. - 1 package 131 140 160NOTE - Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.

Page 3: ML180DF(X) - Dominion Energy

Page 3

HIGH ALTITUDE DERATENOTE - Units may be installed at altitudes up to 4500 ft. above sea level without any modifications.

At altitudes above 4500 ft. units must be derated to match information in the shaded areas shown below.NOTE - This is the only permissible derate for these units.

Input

Gas Manifold Pressure (Outlet) in. w.g. Line Pressure - in. w.g.

0 - 4500 Feet 4501 - 7500 Feet 7501 - 10,000 ft. MinimumMaximumNatural

GasLPG/

PropaneNatural

GasLPG/

Propane1 Natural

GasLPG/

PropaneNatural

GasLPG/

Propane

045 3.5 10 3.5 10 3.5 10 4.5 11 13

070 3.5 10 3.3 10 3.5 10 4.5 11 13

090 3.5 10 3.3 10 3.5 10 4.5 11 13

110 3.5 10 3.3 10 3.5 10 4.5 11 131 Natural Gas High Alitude Orifice Kit required.

OPTIONAL ACCESSORIES - ORDER SEPARATELY“A” Width

Models“B” Width

Models“C” Width

ModelsCABINET ACCESSORIESDownflow Combustible Flooring Base 11M59 11M60 11M61CONTROLSTwinning Kit 15L38 15L38 15L38FILTERS

1 Downflow Filter Cabinet 51W06 51W07 51W08No. and Size of filter - in. (1) 20 x 20 x 1 (2) 20 x 16 x 1 (2) 20 x 16 x 1

service kitsNight Service Kit 51W03 51W03 51W03

Universal Service Kit - Switches 89W19 89W19 89W191 Cleanable polyurethane, frame-type filter.

GAS HEAT ACCESSORIES

InputHigh Altitude

Pressure Switch KitNatural Gas to

LPG/Propane Kit LPG/Propane

to Natural Gas Kit

Natural Gas High Altitude

Orifice Kit

0 - 4500 ft. 4501 - 7500 ft. 7501 - 10,000 ft. 0 - 7500 ft. 7501 - 10,000 ft. 0 - 7500 ft. 7501 - 10,000 ft.

045 No Change No Change 80W51 70W89 76W15 73W81 73W37

070 No Change 80W52 80W51 70W89 76W15 73W81 73W37

090 No Change No Change 80W51 70W89 76W15 73W81 73W37

110 No Change 80W52 80W51 70W89 76W15 73W81 73W37

INSTALLATION CLEARANCESVent Type Type B1 Type C NOTE − Air for combustion must conform to the methods outlined in the

National Fuel Gas Code (NFPA 54/ANSI-Z223.1).NOTE − In the U.S. flue sizing must conform to the methods outlined in the

current National Fuel Gas Code (NFPA 54/ANSI-Z223.1) or applicable provisions of local building codes.

1 Left side requires 4 in. if single wall vent is used on 14-1/2 in. “A” width cabinets, 2 in. on 17-1/2 in. “B” width cabinets.

2 Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with local codes, National Fuel Gas Code ANSI-Z223.1 or National Standard of Canada CAN/CSA-B149.1 and CAN/CSA-B149.2 Installation Code for Gas Burning Appliances”. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.

Sides 0 in. (0 mm) 1 in. (0 mm)

Rear 0 in. (0 mm) 0 in. (0 mm)

Top 1 in. (25 mm) 1 in. (25 mm)

Front 2-1/4 in. (57 mm) 2-1/4 in. (57 mm)

Front (service/alcove) 24 in. (610 mm) 24 in. (610 mm)

Floor 2 Combustible 2 Combustible

Flue 1 in. (25 mm) 6 in. (152 mm)

Page 4: ML180DF(X) - Dominion Energy

Page 4

BLOWER DATA

ML180DF045P36A PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 1524 567 1385 528 1144 431 947 3660.20 1465 542 1351 490 1129 407 943 3540.30 1414 517 1293 463 1111 393 950 3410.40 1343 489 1236 436 1083 371 945 3290.50 1255 464 1190 409 1038 356 897 3110.60 1205 443 1106 380 999 333 870 2920.70 1140 421 1059 366 943 317 816 2750.80 1031 388 962 335 870 297 739 252

ML180DF070P36A PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 1562 591 1386 539 1159 436 956 3740.20 1506 553 1355 504 1149 418 953 3610.30 1459 528 1314 473 1119 392 941 3430.40 1390 500 1264 442 1082 374 915 3230.50 1306 477 1200 415 1048 352 904 3050.60 1213 441 1129 391 987 332 849 2880.70 1140 417 1066 361 901 304 798 2700.80 1038 395 975 342 836 283 717 244

ML180DF090P48B PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 1929 755 1794 668 1585 572 1332 4890.20 1864 717 1745 623 1544 540 1321 4630.30 1779 683 1676 588 1496 510 1296 4400.40 1694 647 1600 558 1443 473 1265 4170.50 1596 607 1502 511 1363 440 1212 3930.60 1483 577 1413 485 1258 406 1148 3700.70 1340 544 1273 449 1148 374 1042 3390.80 1221 505 1138 416 1018 350 917 307

ML180DF110P60C PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 2760 1401 2325 1045 1888 871 1531 6860.20 2670 1362 2319 1003 1937 847 1565 6790.30 2557 1292 2257 964 1945 832 1605 6740.40 2536 1287 2220 949 1935 812 1622 6610.50 2384 1230 2152 911 1918 782 1626 6440.60 2273 1191 2063 884 1884 762 1617 6300.70 2197 1151 2021 875 1822 737 1574 6100.80 2115 1140 1950 854 1749 708 1517 579

ML180DF045P24A PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 1157 399 938 333 764 273 699 2430.20 1120 381 924 322 745 264 677 2370.30 1084 362 890 311 723 258 650 2300.40 1027 349 864 298 695 250 633 2240.50 975 334 814 283 674 238 605 2150.60 902 322 764 268 623 225 564 2030.70 831 305 682 248 549 208 477 1860.80 713 280 576 228 470 192 401 171

ML180DF090P36B PERFORMANCE (Less Filter)External

Static Pressure in. w.g.

Air Volume / Watts at Various Blower Speeds

High Medium-High

Medium-Low Low

cfm Watts cfm Watts cfm Watts cfm Watts0.10 1695 647 1431 546 1180 468 973 3790.20 1641 611 1405 516 1162 443 967 3680.30 1595 589 1384 492 1146 420 958 3490.40 1525 548 1344 472 1136 399 954 3370.50 1438 515 1271 432 1110 374 929 3190.60 1370 489 1197 400 1057 352 886 2990.70 1260 451 1119 374 983 328 823 2730.80 1164 425 1020 344 900 300 743 249

Page 5: ML180DF(X) - Dominion Energy

Page 5

ML180DF PARTS ARRANGEMENT

FIGURE 1

Primary Limit(under combustionair inducer)

Control Box(includes integrated control,interlock switch and transformer)

Gas ValveBurner Box

(includes sensor, ignitorand rollout switches)

CombustionAir Inducer

Blower Access Panel

Heating CompartmentAccess Panel

Heat Exchanger

Flue Chase

Blower Assembly

Secondary Limit

Page 6: ML180DF(X) - Dominion Energy

Page 6

I-UNIT COMPONENTS

ML180DF unit components are shown in figure 1.The gas

valve, combustion air inducer and burners can be ac­

cessed by removing the heating compartment access pan­

el. Electrical components are in the control box (figure 2)

found in the blower section.

CAUTIONElectrostatic discharge can affect elec­tronic components. Take precautionsto neutralize electrostatic charge bytouching your hand and tools to metalprior to handling the control.

1. Control Transformer (T1)

A transformer located in the control box provides power to

the low voltage section of the unit. Transformers on all

models are rated 40VA with a 120V primary and a 24V sec­

ondary.

2. Door Interlock Switch (S51)

A door interlock switch rated 14A at 125VAC is wired in se­

ries with line voltage. When the blower door is removed the

unit will shut down.

FIGURE 2

CONTROL BOX ML180DF

Integrated Control

Transformer

DoorInterlockSwitch

3. Integrated Control (A92)

WARNINGShock hazard.

Disconnect power before servicing. Control is notfield repairable. If control is inoperable, simply re­place entire control.

Can cause injury or death. Unsafe operation will re­sult if repair is attempted.

The hot surface ignition control system consisting of an in­

tegrated control (figure 3 with control terminal designa­

tions in tables 1 and 2), flame sensor and ignitor (figure 6).

The integrated control and ignitor work in combination to

ensure furnace ignition and ignitor durability. The inte­

grated control, controls all major furnace operations. The

integrated control also features a RED LED for trouble­

shooting and two accessory terminals rated at (1) one

amp. See table 3 for troubleshooting diagnostic codes.

The 120 volt ignitor is made from a high strength, silicon

nitride material that provides long life and trouble free

maintenance.

Electronic Ignition (Figure 4)On a call for heat the integrated control monitors the com­

bustion air inducer pressure switch. The control will not be­

gin the heating cycle if the pressure switch is closed (by-

passed). Once the pressure switch is determined to be

open, the combustion air inducer is energized. When the

differential in the pressure switch is great enough, the pres­

sure switch closes and a 15-second pre-purge begins. If

the pressure switch is not proven within 2-1/2 minutes, the

integrated control goes into Watchguard-Pressure Switch

mode for a 5-minute re-set period.

After the 15-second pre-purge period, the ignitor warms up

for 20 seconds after which the gas valve opens for a 4-sec­

ond trial for ignition. The ignitor remains energized for the

first 3 seconds of trial for ignition. If ignition is not proved

during the trial for ignition, the integrated control will try four

more times with an inter purge and warm-up time between

trials of 30 seconds. After a total of five trials for ignition (in­

cluding the initial trial), the integrated control goes into

Watchguard-Flame Failure mode. After a 60-minute reset

period, the integrated control will begin the ignition se­

quence again.

Page 7: ML180DF(X) - Dominion Energy

Page 7

TABLE 1

4-Pin Terminal Designation

PIN # FUNCTION

1 Combustion Air Inducer Line

2 Ignitor Line

3 Combustion Air Inducer Neutral

4 Ignitor Neutral

TABLE 2

12-Pin Terminal Designations

PIN # FUNCTION

1 High Limit Output

2 Sensor

3 24V Line

4 Not Used

5 Rollout Switch Out

6 24V Neutral

7 High Limit Input

8 Ground

9 Gas Valve Common

10 Pressure Switch In

11 Rollout Switch In

12 Gas Valve Out

FIGURE 3

INTEGRATED CONTROL(Automatic Hot Surface Ignition System)

TERMINAL DESIGNATIONSHUM

LINE

XFMR

EAC

COOL

HEAT

PARK

CONT

NEUTRALS

Humidifier (120VAC)

Input (120VAC)

Transformer (120VAC)

Indoor Air Qality Accessory Air Cleaner (120VAC)

Blower - Cooling Speed (120VAC)

Blower - Heating Speed (120VAC)

Dead terminals to park alternate spd taps

Continuous blower

Neutral terminals (120VAC)

PUSH BUTTON

LED

TWIN

TWIN Twinning Terminal (24VAC)

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

ÉÉ

DEMANDCAI

GAS VALVE

15

ON

OFF

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

ÉÉÉÉ

39

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉIGNITOR

351

Pre -Purge Ignitor Warm-upTrial forIgnition

Post Purge

5 SEC69

*Blower on time will be 30 seconds after flame is sensed. Blower off time will depend on “OFF TIME” Setting.

INDOOR BLOWER ÉÉÉÉÉÉÉÉÉ

Blower “On”*Delay

ELECTRONIC IGNITION

FIGURE 4

Page 8: ML180DF(X) - Dominion Energy

Page 8

TABLE 3

Note - This control is equipped with a push button switch for

diagnostic code recall. The control stores the last 5 fault

codes in non-volatile memory. The most recent fault code is

flashed first, the oldest fault code is flashed last. There is a

2 second pause between codes. When the push button

switch is pressed for less than 5 seconds, the control will

flash the stored fault codes when the switch is released.

The fault code history may be cleared by pressing the push

button switch for more than 5 seconds.

Integrated Control Diagnostic Codes

DIAGNOSTIC CODES

LED Status DESCRIPTION

LED OffNo power to control or control harware

fault detected.

LED On Normal operation.

1 FlashFlame present with gas vavle

de-energized.

2 FlashesPressure switch closed with combustion

air inducer de-energized.

3 FlashesPressure switch open with combus­tion air inducer energized.

4 Flashes Primary limit switch open.

5 Flashes Rollout switch open.

6 Flashes Pressure switch cycle lockout.

7 Flashes Lockout, burners fail to light.

8 FlashesLockout, buners lost flame too many

times.

9 Flashes Line voltage polarity incorrect.

Fan Time Control

Heating Fan On Time

The fan on time of 30 seconds is not adjustable.

Heating Fan Off Time

Fan off time (time that the blower operates after the heat

demand has been satisfied) can be adjusted by moving the

jumper to a different setting. The unit is shipped with a fac­

tory fan off setting of 120 seconds. For customized comfort,

monitor the supply air temperature once the heat demand

is satisfied. Note the supply air temperature at the instant

the blower is de-energized.

Adjust the fan-off delay to achieve a supply air temperature

between 90° - 110° at the instant the blower is de-ener­

gized. (Longer delay times allow for lower air temperature,

shorter delay times allow for higher air temperature). See

figure 5.

Cooling Fan On Time

The fan on time is 2 seconds and is not adjustable.

Cooling Fan Off Time

The control has a 60 second fan off delay after cooling de­

mand has been met. This delay is factory set and not ad­

justable.

HEAT FAN‐OFF TIME IN SECONDS

To adjust fan-off timing, reposition jumper across pins toachieve desired setting.

NO JUMPER

FIGURE 5

60

90

120

180 60

90

120

180 6

090

120

180 6

090

120

180

60 Second off Time

90 Second off Time

120 Second off Time

180 Second off Time

Page 9: ML180DF(X) - Dominion Energy

Page 9

ML180DF HEATING COMPONENTS

FIGURE 6

Internal flue pipe

Gasket

Orifice plate

Pressure switch

Collector box

Combustion air inducer

Ignitor

Sensor

Rolloutswitch

Burners

Burner boxassembly

Manifold andGas valve

4. Flame Rollout Switch (Figure 6)

Flame rollout switch (S47) is a high temperature limit. The

limit is a N.C. SPST manual‐reset limit connected in series

with the integrated control A92. When S47 senses rollout,

the integrated control immediately stops ignition and

closes the gas valve. If unit is running and flame rollout is

detected, the gas valve will close and integrated control will

be disabled. Rollout can be caused by a blocked heat ex­

changer, blocked flue or lack of combustion air. The switch

has a factory setpoint of 210°F and cannot be adjusted. To

manually reset a tripped switch, push the reset button located

on the control.

5. Primary Limit Control

The primary limit on ML180DF units is located in the heating

vestibule panel under the combustion air inducer. When ex­

cess heat is sensed in the heat exchanger, the limit will open. If

the limit is open, the integrated control energizes the supply air

blower and closes the gas valve. The limit automatically resets

when unit temperature returns to normal. The switch must re­

set within three minutes or the control will go into Watchguard

for one hour. The switch is factory set and cannot be ad­

justed. The switch may have a different setpoint for each unit

model number. If limit switch must be replaced, refer to Len­

nox ProductZone repair parts list on Lennox DaveNet®.

6. Flame Sensor (Figure 6)

A flame sensor is located on the left side of the burner sup­

port. The sensor is mounted on the flame rollout plate and

the tip protrudes into the flame envelope of the left-most

burner. The sensor can be removed for service (clean us­

ing steel wool) without removing any part of the burners.

During operation, flame is sensed by current passed

through the flame and sensing electrode. The integrated

control allows the gas valve to remain open as long as

flame signal is sensed.

A microamp DC meter is needed to check the flame signalon the integrated control.

Flame (microamp) signal is an electrical current which passesfrom the integrated control to the sensor during unit operation.Current passes from the sensor through the flame to ground tocomplete a safety circuit.

Page 10: ML180DF(X) - Dominion Energy

Page 10

To Measure Flame Signal - Integrated Control:

Use a digital readout meter capable of reading DC micro­amps. See figure 7 and table 4 for flame signal check.

1 - Set the meter to the DC amps scale.

2 - Turn off supply voltage to control.

3 - Remove sensor wire from integrated control.

4 - Connect (-) lead to flame sensor wire.

5 - Connect (+) lead to Terminal FS on integrated control.

6 - Turn supply voltage on and close thermostat contacts tocycle system.

7 - When main burners are in operation for two minutes, takereading.

TABLE 4

Flame Signal in Microamps

Normal Low Drop Out

� 1.5 0.5 - 1.4 � 0.4

FIGURE 7

Measuring Flame Signal(upflow furnace shown)

FlameSensor

Flame SensorWire

IntegratedControl

Remove Sensor Wire fromIntegrated Control andConnect Alligator Clip (−) to Flame Sensor Lead

Flame SensorTerminal

Remove Sensor Wire fromIntegrated Control and

Connect Alligator Clip (+)to Terminal on Control

(+)

DIGITAL METER

(+) To ControlSensor

Terminal

(-) Toflame

sensor

Set dial to measure dc microamps

(+)

Red CollarIndicatesPositive Lead

Page 11: ML180DF(X) - Dominion Energy

Page 11

7. Ignitor (Figure 6)

The nitride ignitor used on ML180DF units is made from a

proprietary ceramic material. To check ignitor, measure its

resistance and voltage. A value of 39 to 70 ohms indicates

a good ignitor. Voltage to the ignitor should be 120VAC.

See figure 8 for resistance, and voltage check.

NOTE - The ML180DF furnace contains electronic

components that are polarity sensitive. Make sure that

the furnace is wired correctly and is properly grounded.

FIGURE 8

Test 1Check ignitor circuit for correct resistance.

Remove 4-pin plug from control.Check ohms reading across terminals 2 and 4.

If value is correct (39 to 70 ohms), this is the only testneeded.If the reading on the meter is not correct,

(0 or infinity) then a second test is needed.

Test 2Check ignitor for correct resistance.

Seperate the 2-pin jack-plug near the manifold and checkresistance of ignitor at the plug. Reading should be

between 39 and 70 ohms. If the reading is correct, thenthe problem is with the wiring between the jack-plug and

the control. If reading is not correct, the issue is the ignitor.

Test 3Check ignitor for correct voltage

Insert meter probes into terminals 2 and 4 (use smalldiameter probes in order not to damage plug).

Check voltage during 20 second ignitor warm up period.Voltage should read 120 volts + 10%. If voltage reads below

these values, check for correct supply voltage to furnace.

Integrated Control BoardDetail

Test 1

Integrated Control BoardDetail

Test 2

Integrated Control BoardDetail

Test 3

Page 12: ML180DF(X) - Dominion Energy

Page 12

8. Gas Valve (Figure 6)

The ML180DF uses internally redundant gas valve to as­

sure safety shut-off. If the gas valve must be replaced, the

same type valve must be used.

24VAC terminals and valve switch are located on the valve. All

terminals on the gas valve are connected to wires from the in­

tegrated control. 24V applied to the terminals energizes the

valve.

Inlet and outlet pressure taps are located on the valve. A regu­

lator adjustment screw is located on the valve.

LPG changeover kits are available from Lennox. Kits include

burner orifices and a gas valve regulator spring.

9. Combustion Air Inducer (B6)

All ML180DF units use a combustion air inducer to move air

through the burners and heat exchanger during heating op­

eration. The blower uses a 120VAC motor. The motor oper­

ates during all heating operation and is controlled by inte­

grated control A92. The inducer also operates for 15 sec­

onds before burner ignition (pre‐purge) and for 5 seconds

after the gas valve closes (post‐purge).

A pressure switch mounted on the combustion air inducer ori­

fice plate is used to prove inducer operation. The combustion

air inducer orifice will be different for each model. See table 5

for orifice sizes. The switch monitors air pressure in the induc­

er housing. During normal operation, the pressure in the

housing is negative. If pressure becomes less negative (sig­

nifying any obstruction in the flue) the pressure switch opens.

When the proving switch opens, the integrated control (A92)

immediately de-energizes the gas valve to prevent burner

operation.

TABLE 5

ML180DF Unit C.A.I. Orifice Size

045P24A 1.094

045P36A 1.063

070(X)P36A 1.344

090P36B 1.531

090(X)P48B 1.531

110(X)P60C 1.718

10. Combustion Air Inducer Pressure Switch (S18)

ML180DF series units are equipped with a combustion air

pressure switch located on the combustion air inducer ori­

fice bracket. The switch is connected to the combustion air

inducer housing by means of a flexible silicone hose. It mon­

itors negative air pressure in the combustion air inducer

housing.

The switch is a SPST Normally open proving switch electri­

cally connected to the furnace control. The purpose of the

switch is to prevent burner operation if the combustion air in­

ducer is not operating or if the flue becomes obstructed.

On start‐up, the switch senses that the combustion air in­

ducer is operating. It closes a circuit to the integrated con­

trol when pressure inside the combustion air inducer de­

creases to a certain set point. Set points vary depending on

unit size. See table 6. The pressure sensed by the switch is

negative relative to atmospheric pressure. If the flue be­

comes obstructed during operation, the switch senses a

loss of negative pressure (pressure becomes more equal

with atmospheric pressure) and opens the circuit to the in­

tegrated control and gas valve. A bleed port on the switch

allows relatively dry air in the vestibule to purge switch tub­

ing, to prevent condensate build up.

TABLE 6

ML180DF Set Point inches w.c.

045P24A 0.60

045P36A 0.60

070(X)P36A 0.65

090P36B 0.60

090(X)P48B 0.60

110(X)P60C 0.65

110P60C 0.69

The switch is factory set and is not field adjustable. It is asafety shut‐down control in the furnace and must not be by-passed for any reason. If switch is closed or by-passed, theintegrated control will not initiate ignition at start up.

Troubleshooting

See figure 9 for measuring operating pressure and check­ing resistance in the pressure switch.

Page 13: ML180DF(X) - Dominion Energy

Page 13

FIGURE 9

MULTI−METERSET TO MEASURE OHMS

ToPressure Switch

High

Low

or

Remove tubing from CAI andinsert “Tee” and additional tubing.

Field ProvidedTubing To CAI Port

11. Blower Motors and Capacitors

All ML180DF units use direct drive blower motors. All motors

are 120V permanent split capacitor motors to ensure maxi­

mum efficiency. See Specifications section at the front of this

manual for motor specifications. Ratings for capacitors will

be on motor nameplate.

12. Secondary Limit Control

The secondary limit is located in the blower compartment on

the back side of the blower housing. See figure 10. When ex­

cess heat is sensed in the blower compartment, the limit will

open. If the limit is open, the furnace control energizes the sup­

ply air blower and closes the gas valve. The limit automatically

resets when unit temperature returns to normal. The secon­

dary limit cannot be adjusted. FIGURE 10

To Remove Blower From Unit:1. Disconnect Power, 2. Remove internal flue pipe and chase

3. Remove Control Box 4. Remove Bolts. 5. Unplug MotorWires From Control Board. Then Slide Out Front of Unit.

Supply Air Blower

Page 14: ML180DF(X) - Dominion Energy

Page 14

II- PLACEMENT AND INSTALLATION

Make sure unit is installed in accordance with installation

instructions and applicable codes.

III- START‐UP

A- Heating Start‐Up

WARNINGShock and burn hazard.

ML180DF units are equipped with a hot surface igni­tion system. Do not attempt to light manually.

Gas Valve Operation

FIGURE 11

GAS VALVE SHOWN IN ON POSITION

MANIFOLDPRESSURE

OUTLETPORT

INLETPRESSURE

PORT

MANIFOLDPRESSURE

ADJUSTMENTSCREW

1 - STOP! Read the safety information at the beginning of

this section.

2 - Set the thermostat to the lowest setting.

3 - Turn off all electrical power to the unit.

4 - This furnace is equipped with an ignition device which

automatically lights the burners. Do not try to light the

burners by hand.

5 - Remove the heating compartment access panel.

6 - Move gas valve switch to OFF position. Do not

force. See figure 11.

7 - Wait five minutes to clear out any gas. If you then smell

gas, STOP! Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's instruc­

tions. If you do not smell gas go to next step.

8 - Move gas valve switch to ON position. Do not force.

See figure 11.

9 - Replace the heating compartment access panel.

10- Turn on all electrical power to to the unit.

11- Set the thermostat to desired setting.

NOTE - When unit is initially started, steps 1 through 11

may need to be repeated to purge air from gas line.

12- If the appliance will not operate, follow the instructions

“Turning Off Gas to Unit” and call the gas supplier.

Turning Off Gas to Unit

1 - Set the thermostat to the lowest setting.

2 - Turn off all electrical power to the unit if service is to be

performed.

3 - Remove the heating compartment access panel.

4 - Move gas valve switch to OFF position. Do not

force. See figure 11.

5 - Replace the heating compartment access panel.

B- Safety or Emergency Shutdown

Disconnect main power to unit. Close manual and main gas

valves.

C- Extended Period Shutdown

Turn off thermostat or set to “UNOCCUPIED” mode. Close

all gas valves (both internal and external to unit) to guaran­

tee no gas leaks into combustion chamber. Turn off power

to unit. All access panels and covers must be in place and

secured.

IV-HEATING SYSTEM SERVICE CHECKSA- C.S.A. Certification

All units are C.S.A. design certified without modifications.

Refer to the ML180DF Installation Instruction.

B- Gas Piping

Gas supply piping should not allow more than 0.5”W.C. drop

in pressure between gas meter and unit. Supply gas pipe

must not be smaller than unit gas connection.

Compounds used on gas piping threaded joints should be

resistant to action of liquefied petroleum gases.

C- Testing Gas Piping

CAUTIONIf a flexible gas connector is required or allowed bythe authority that has jurisdiction, black iron pipeshall be installed at the gas valve and extend outsidethe furnace cabinet.

IMPORTANTIn case emergency shutdown is required, turn offthe main shut‐off valve and disconnect the mainpower to unit. These controls should be properlylabeled by the installer.

WARNINGDo not exceed 600 in-lbs (50 ft-lbs) torque when at­taching the gas piping to the gas valve.

When pressure testing gas lines, the gas valve must be dis­

connected and isolated. Gas valves can be damaged if

subjected to more than 0.5 psig (14” W.C.). See figure 12. If

the pressure is equal to or greater than 0.5 psig (14”W.C.),

close the manual shut-off valve before pressure testing to

isolate furnace from gas supply.

Page 15: ML180DF(X) - Dominion Energy

Page 15

FIGURE 12

MANUAL MAIN SHUT-OFF VALVE

WILL NOT HOLD TEST PRESSUREIN EXCESS OF 0.5 PSIG (14”W.C.)

GAS VALVE

CAP

GAS PIPING TEST PROCEDURE

FIELD PROVIDEDLINE PRESSURE TAP

When checking piping connections for gas leaks, use pre­

ferred means. Kitchen detergents can cause harmful corro­

sion on various metals used in gas piping. Use of a specialty

Gas Leak Detector is strongly recommended. It is available

through Lennox under part number 31B2001. See Corp.

8411-L10, for further details.

Do not use matches, candles, flame or any other source of

ignition to check for gas leaks.

D- Gas Pressure Adjustment

Gas Flow (Approximate)

TABLE 7

GAS METER CLOCKING CHART

ML180DFUnit

Seconds for One Revolution

Natural LP

1 cu ftDial

2 cu ftDial

1 cu ftDial

2 cu ftDIAL

-045 80 160 200 400

-070 55 110 136 272

-090 41 82 102 204

-110 33 66 82 164

-135 27 54 68 136

Natural-1000 btu/cu ft LP-2500 btu/cu ft

Furnace should operate at least 5 minutes before check­

ing gas flow. Determine time in seconds for two revolu­

tions of gas through the meter. (Two revolutions assures a

more accurate time.) Divide by two and compare to time

in table 7. If manifold pressure matches table 9 and rate is

incorrect, check gas orifices for proper size and restric­

tion. Remove temporary gas meter if installed.

NOTE - To obtain accurate reading, shut off all other gas

appliances connected to meter.

E- Supply and Manifold PressureSupply Pressure Measurement

1 - Remove the threaded plug from the inlet side of the

gas valve and install a field-provided barbed fitting.

Connect to a test gauge to measure supply pressure.

2 - Start unit and allow 5 minutes for unit to reach steady

state.

3 - After allowing unit to stabilize for 5 minutes, record

supply pressure and compare to value given in table 9.

Manifold Pressure Measurement

1 - Remove the threaded plug from the outlet side of the

gas valve and install a field-provided barbed fitting.

Connect to a test gauge to measure manifold pres­

sure.

2 - Start unit and allow 5 minutes for unit to reach steady

state.

3 - While waiting for the unit to stabilize, observe the

flame. Flame should be stable and should not lift from

burner. Natural gas should burn blue.

4 - After allowing unit to stabilize for 5 minutes, record

manifold pressure and compare to value given in table

9.

NOTE - Shut unit off and remove manometer as soon as an

accurate reading has been obtained. Take care to remove

barbed fitting and replace threaded plug.

F- Proper CombustionFurnace should operate a minimum 15 minutes with cor­

rect manifold pressure and gas flow rate before checking

combustion. Take combustion sample beyond the flue out­

let and compare to the tables below. The maximum carbon

monoxide reading should not exceed 50 ppm.

TABLE 8

ML180DF UnitCO2% For

Nat

CO2% For

L.P.

-045

6.0 - 7.5 6.9 - 8.5-070

-090

-110

G- High AltitudeThe manifold pressure may require adjustment and com­

bustion air pressure switch may need replacing to ensure

proper combustion at higher altitudes. Refer to table 9 for

manifold pressure and table 10 for pressure switch change

and gas conversion kits.

IMPORTANTFor safety, shut unit off and remove manometer assoon as an accurate reading has been obtained.Take care to replace pressure tap plug.

Page 16: ML180DF(X) - Dominion Energy

Page 16

TABLE 9

Manifold Pressure Settings at all Altitudes

ModelInput Size

Gas 0-4500 ft 4501-7500 ft 7501 - 10,000 ft

Supply Pressurein.wg.

Min Max

045Nat 3.5 3.5 3.5 4.5 13.0

LP/propane 10.0 10.0 10.0 11.0 13.0

070Nat 3.5 3.3 3.5 4.5 13.0

LP/propane 10.0 10.0 10.0 11.0 13.0

090Nat 3.5 3.3 3.5 4.5 13.0

LP/propane 10.0 10.0 10.0 11.0 13.0

110Nat 3.5 3.3 3.5 4.5 13.0

LP/propane 10.0 10.0 10.0 11.0 13.0

TABLE 10

Pressure Switch and Gas Conversion Kits at all Altitudes

ModelInput Size

High Altitude Pressure Switch KitHigh Altitude

Natural Gas BurnerOrifice Kit

Natural Gas to LP/PropaneGas Change Over Kit

LP/Propane toNatural Gas

Change Over Kit

0-4500 ft 4501-7500 ft 7501 - 10,000 ft 7501 - 10,000 ft 0 - 7500 ft 7501 - 10,000 ft 0 - 7500 ft

045

No Change

No Change

80W51 73W37 70W89 76W15 73W81

070 80W52

090 No Change

090(X)80W52

110

NOTE - A natural to L.P. propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the conversion

procedure.

Page 17: ML180DF(X) - Dominion Energy

Page 17

H- Proper Ground and Voltage

A poorly grounded furnace can contribute to premature ig­nitor failure. Use the following procedure to check forground and voltage to the integrated control. 1 - Measure the AC voltage between Line Neutral (spade

terminals) and “C” terminal (low voltage terminal

block) on the integrated control. See figure 13. A wide

variation in the voltage between Line Neutral and “C”

as a function of load indicates a poor or partial ground.

Compare the readings to the table below. If the read­

ings exceed the maximum shown in table 1, make re­

pairs before operating the furnace.

2 - In addition, measure the AC voltage from Line Hot to

Line Neutral (spade terminals) on the integrated con­

trol. See figure 14. This voltage should be in the range

of 97 to 132 Vac

TABLE 11

Furnace StatusMeasurement VAC

Expected Maximum

Power On Furnace Idle 0.3 2

CAI / Ignitor Energized 0.75 5

Indoor Blower Energized Less than 2 10

CHECK VOLTAGE BETWEEN LINE NEUTRALAND LOW VOLTAGE “C” TERMINAL

FIGURE 13

CHECK VOLTAGE BETWEEN LINE HOTAND LINE NEUTRAL

FIGURE 14

Page 18: ML180DF(X) - Dominion Energy

Page 18

V-TYPICAL OPERATING CHARACTERISTICS

A-Blower Operation and Adjustment

NOTE- The following is a generalized procedure and

does not apply to all thermostat controls.

1 - Blower operation is dependent on thermostat control

system.

2 - Generally, blower operation is set at thermostat sub­

base fan switch. With fan switch in ON position, blower

operates continuously. With fan switch in AUTO position,

blower cycles with demand or runs continuously while

heating or cooling circuit cycles.

3 - Depending on the type of indoor thermostat, blower

and entire unit will be off when the system switch is in

OFF position.

B-Temperature Rise (Figure 15)

Temperature rise for ML180DF units depends on unit input,

blower speed, blower horsepower and static pressure as

marked on the unit rating plate. The blower speed must be

set for unit operation within the range of “TEMP. RISE °F”

listed on the unit rating plate.

FIGURE 15

Upflow Furnace Shown

Supply Air

Return Air

TEMPERATURE RISE

Supply Duct Temperature _____Return Duct Temperature - ____Temperature Rise = _________

C-External Static Pressure

1 - Tap locations shown in figure 16 .

2 - Punch a 1/4” diameter hole in supply and return air ple­

nums. Insert manometer hose flush with inside edge of

hole or insulation. Seal around the hose with perma­

gum. Connect the zero end of the manometer to the

discharge (supply) side of the system. On ducted sys­

tems, connect the other end of manometer to the return

duct as above.

3 - With only the blower motor running and the evaporator

coil dry, observe the manometer reading. Adjust blow­

er motor speed to deliver the air desired according to

the job requirements. For heating speed external static

pressure drop must not be more than 0.5” W.C. For

cooling speed external static pressure drop must not

be more than 0.8” W.C.

4 - Seal the hole when the check is complete.

FIGURE 16

Upflow Furnace Shown

EXTERNAL STATIC PRESSURE

Supply Duct StaticReturn Duct Static +

Total Duct Static = (dry coil)

Supply Air

Return Air -+

or

High

Low

D-Blower Speed Taps

Blower speed tap changes are made on the integrated con­

trol. See figure 3. The heating tap is connected to the

“HEAT” terminal and the cooling tap is connected to the

“COOL” terminal. The continuous blower tap is connected

to the “CONT” terminal. Unused taps must be secured on

dummy terminals labeled ”PARK. To change out existing

speed tap, turn off power and switch out speed tap with tap

connected to “PARK”. See blower speed tap table on unit

diagram for motor tap colors for each speed.

Page 19: ML180DF(X) - Dominion Energy

Page 19

VI-MAINTENANCE

A-Preliminary and Seasonal Checks

1 - Inspect electrical wiring, both field and factory installed

for loose connections. Tighten as required.

2 - Check voltage at disconnect switch. Voltage must be

within range listed on the nameplate. If not, consult the

power company and have voltage condition corrected

before starting unit.

At the beginning of each heating season, the system

should be checked as follows:

B-Filters

Filters should be inspected monthly. Clean or replace the

filters when necessary to ensure that the furnace operates

properly. Replacement filters must be rated for high veloc­

ity airflow. See table 12.

IMPORTANTIf a high­efficiency filter is being installed as part ofthis system to ensure better indoor air quality, the fil­ter must be properly sized. High­efficiency filtershave a higher static pressure drop than standard­ef­ficiency glass/foam filters. If the pressure drop is toogreat, system capacity and performance may be re­duced. The pressure drop may also cause the limit totrip more frequently during the winter and the indoorcoil to freeze in the summer, resulting in an increasein the number of service calls.

Before using any filter with this system, check thespecifications provided by the filter manufactureragainst the data given in the appropriate LennoxProduct Specifications bulletin. Additional informa­tion is provided in Service and Application NoteACC­00­2 (August 2000).

TABLE 12

Cabinet Width Return Air Filter Size (inches)

A (14-1/2”) 14 x 25 x 1 (1)

B (17-1/2”) 16 x 25 x 1 (1)

C (21”) 20 x 25 x 1 (1)

Cleaning the Heat Exchanger and Burners

NOTE - Use papers or protective covering in front of the fur­

nace during cleaning.

1 - Turn off both electrical and gas power supplies to fur­nace.

2 - Remove flue pipe, top cap, flue chase and internal flue

pipe assembly from the unit.

3 - Label the wires from gas valve, rollout switches, prima­

ry limit switch and make-up box then disconnect them.

4 - Remove the screws that secure the combustion air in­

ducer/pressure switch assembly to the collector box.

Carefully remove the combustion air inducer to avoid

damaging blower gasket. If gasket is damaged, it must

be replaced to prevent leakage.

5 - Remove the collector box located behind the combus­

tion air inducer. Be careful with the collector box gas­

ket. If the gasket is damaged, it must be replaced to

prevent leakage.

6 - Disconnect gas supply piping. Remove the four screws

securing the burner manifold assembly to the vestibule

panel and remove the assembly from the unit.

7 - NOX units only - Remove screw securing NOX insert.

Remove NOX insert.

8 - Remove screws from both sides, top and bottom of

vestibule panel.

9 - Remove heat exchanger. It may be necessary to

spread cabinet side to allow more room. If so, remove

five screws from the left side or right side of cabinet.

See figure 18.

10- Back wash using steam. Begin from the burner opening

on each clam. Steam must not exceed 275°F.

11- To clean burners, run a vacuum cleaner with a soft brush

attachment over the face of burners. Visually inspect in­

side the burners and crossovers for any blockage

caused by foreign matter. Remove any blockage. Figure

17 shows burner detail.

12- To clean the combustion air inducer visually inspect and

using a wire brush clean where necessary. Use com­

pressed air to clean off debris and any rust.

13- Reinstall heat exchanger in vestibule. (Replace the

five screws in the cabinet from step 10 if removed).

14- NOX units only - replace NOX inserst.

15- Reinstall collector box, combustion air assembly, inter­

nal flue pipe and flue chase. Seal with high tempera­

ture RTV. Reinstall all screws to the collector box and

combustion air inducer. Failure to replace all screws

may cause leaks. Inspect gaskets for any damage and

replace if necessary.

Page 20: ML180DF(X) - Dominion Energy

Page 20

ML180DF BURNER, COMBUSTION AIR INDUCER ASSEMBLY &HEAT EXCHANGER REMOVAL

FIGURE 17

Gasket

Internal flue pipe

Glue chaseGasket

Orifice plate

Pressure switch

Collector boxNox insert(if applicable)

Heat exchanger

Combustion air inducer

Ignitor

Sensor

Rolloutswitch

Burners

Burner boxassembly

Manifold andGas valve

Retention rings

Cross over

16- Reinstall burner box, manifold assembly and burner box

cover.

17- Reconnect all wires.

18- Reconnect top cap and vent pipe to combustion air in­

ducer outlet.

19- Reconnect gas supply piping.

20- Turn on power and gas supply to unit.

21- Set thermostat and check for proper operation.

22- Check all piping connections, factory and field, for gas

leaks. Use a leak detecting solution or other preferred

means.

CAUTIONSome soaps used for leak detection are corrosive tocertain metals. Carefully rinse piping thoroughly af­ter leak test has been completed. Do not usematches, candles, flame or other sources of ignitionto check for gas leaks.

23- If a leak is detected, shut gas and electricity off and

repair leak.

24- Repeat steps 22 and 23 until no leaks are detected.

25- Replace access panel.FIGURE 18

Remove five screws if necessary(either side of cabinet)

1

2

3

4

5

Page 21: ML180DF(X) - Dominion Energy

Page 21

C-Supply Air Blower

1 - Check and clean blower wheel.

2 - Motors used on the Lennox ML180DF series units

are permanently lubricated and need no further lu­

brication.

D-Flue and Chimney

Flue must conform to local codes. In the absence of local

codes, flue must meet the National Fuel Gas Code

ANSI-Z223.1 venting requirements. Flue pipe deteriorates

from the inside out and must be disconnected in order to

check thoroughly. Check flue pipe, chimney and all con­

nections for tightness and to make sure there is no block­

age or leaks.

E-Electrical

1 - Check all wiring for loose connections.

2 - Check for the correct voltage at the furnace (furnace

operating). Correct voltage is 120VAC + 10%

3 - Check amp-draw using a true RMS meter on the blow­er motor with blower access panel in place. See figure19.Furnace Nameplate__________Actual__________

FIGURE 19

kVArkWh

COMMV3V1 V2

POFF

MREX−

1

W32

Check Motor AMP Draw(upflow furnace shown)

True RMS Meter

Page 22: ML180DF(X) - Dominion Energy

Page 22

VII- WIRING AND SEQUENCE OF OPERATION

6

7

1

10

4

3

8

ML180DF Schematic Wiring Diagram and Sequence of Operation

5

1 - Line voltage is applied to L1 and N. the T1 low voltage transformer is energized, and line voltage is applied to B3 indoor blower.

2 - S47 rollout switch must be closed in order for 24V from transformer to be output on integrated control ”R” to power thermostat.

3 - When there is a call for heat, W1 of the thermostat energizes W of the furnace control with 24VAC.

4 - A92 integrated control runs a self-check. S10 primary limit and S21 secondary limit contacts are found to be closed. Call for heat can continue.

5 - A92 integrated control energizes B6 combustion air inducer. S18 combustion air pressure switch closes . Once S18 closes, a 15-second

pre-purge follows.

6 - A92 integrated control energizes R33 ignitor. A 20-second warm-up period begins.

7 - GV1 gas valve opens for a 4-second trial for ignition

8 - Flame is sensed, gas valve remains open for the heat call.

9 - After 30-second delay (from flame sensed), A92 integrated control applies 24VAC to Heat speed of B3 indoor blower.

10 - When heat demand is satisfied, W1 of the indoor thermostat de-energizes W of A92ignition control which de-energizes GV1 gas valve.

B6 combustion air inducer continues a 5-second post-purge period, and B3 indoor blower completes a selected OFF time delay.

5

9

2

1

Page 23: ML180DF(X) - Dominion Energy

Page 23

Troubleshooting: Heating Sequence of Operation

HEATING SEQUENCE OF OPERATION

NORMAL HEATING MODE ABNORMAL HEATING MODE

CONTROL SELF-CHECK OKAY?

NORMAL OPERATION:LED: STEADY ON

NO

YES

YES

GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER DELAY OFF.

LED: OFF

POLARITY REVERSED.LED: 9 FLASHES

POWER ON

IS POLARITY CORRECT?

ROLLOUT SWITCH CLOSED?

THERMOSTAT CALLS FOR HEAT:LED: STEADY ON

IS COMBUSTION AIRPRESSURE SWITCH OPEN?

GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON.

LED: 5 FLASHESSEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSES

AND POWER IS RESET OR T'STAT IS INTERRUPTEDFOR MINIMUM OF 1 SECOND.

GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER ON HEATING SPEED.

LED: 1 FLASH

GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

INDOOR BLOWER OFF WITH DELAY.LED: 2 FLASHES

(Sequence holds until pressure switchopens or thermostat resets control.)

NO

NO

YES

YES

IS VOLTAGEABOVE 90 VOLTS?

LED: ON STEADYIGNITOR WILL GLOW DIMLY BUT WILL NOT LIGHT

NO

NO

NO

IS COMBUSTION AIR INDUCER ENERGIZED?

HAS COMBUSTION AIR PRESSURESWITCH CLOSED IN 2.5 MINUTES?

YES

YESPRESSURE SWITCH IS IN WATCHGUARD MODE.

GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH DELAY.

LED: 3 FLASHESIS 5‐MINUTE RESET PERIOD COMPLETE?

NO

PRIMARY AND SECONDARY LIMIT SWITCH.CLOSED?

YES

YES

CONTINUED NEXT PAGE

COMBUSTION AIR INDUCER OFF.INDOOR BLOWER ON

LED: 4 FLASHESNO

YES

NO

YES

IS THERE A PROPER GROUND?

YES

NOIMPROPER GROUND.

LED: OFFCONTROL WILL NOT RESPOND TO CALL FOR HEAT

UNTIL PROPER GROUND.

YES

YES

BURNER OFF?

(Contiuous Flame Check)

Page 24: ML180DF(X) - Dominion Energy

Page 24

Troubleshooting: Heating Sequence of Operation (Continued)

HEATING SEQUENCE CONTINUED

NORMAL HEATING MODE ABNORMAL HEATING MODE

FLAME RECTIFICATION CURRENTCHECK. CAN FLAME BE PROVEN WITHIN4 SECONDS AFTER GAS VALVE OPENS?

FLAME PRESENT?

INDOOR BLOWER ONAFTER 30-SECOND DELAY

PRIMARY AND SECONDARY LIMITSWITCHES CLOSED?

COMBUSTION AIR PRESSURESWITCH CLOSED?

LOW FLAME SIGNAL(Does not affect operation of control)

LED: ON STEADY

GAS VALVE DE-ENERGIZED.COMBUSTION AIR INDUCER DE-ENERGIZED.

INDOOR BLOWER ON UNTIL SWITCH CLOSES.LED: 4 FLASHES

IS LIMIT SWITCH CLOSED?

GAS VALVE DE-ENERGIZED.COMBUSTION AIR INDUCER ON.

INDOOR BLOWER OFF WITH DELAYLED: 6 FLASHES 5 MINUTE PRESSURE

SWITCH WATCHGUARD MODE.

15‐SECOND COMBUSTION AIR INDUCER PREPURGEINITIATED BY CLOSED PRESSURE SWITCH.

YES

IGNITOR WARM‐UP -- 20 SECONDS.

YES

YES

FLAME STABILIZATION PERIOD.

GAS VALVE OFF. COMBUSTION AIR INDUCER ON.INDOOR BLOWER OFF.

HAS CONTROL FAILED TO SENSE FLAME FORFIVE CONSECUTIVE TRIES DURING A SINGLE

HEAT DEMAND?

WATCHGUARD MODE. GAS VALVE OFF.COMBUSTION AIR INDUCER OFF.

INDOOR BLOWER OFF WITH DELAYLED: 7 FLASHES WATCHGUARD FAILURE CODE.

IS 60‐MINUTE RESET PERIOD COMPLETE?

NO

4 SECONDS

YES

HAS CONTROL RESET IGNITIONSEQUENCE FOUR TIMES?

FLAME SIGNAL 1.5 MICROAMPS OR GREATER?

YES

YES

YES

ROLLOUT SWITCH CLOSED?

GAS VALVE POWER OFF. COMBUSTION AIR INDUCER POWER ON AFTER 15

SECOND DELAY. INDOOR BLOWER ONLED: 5 FLASHES

SEQUENCE HOLDS UNTIL ROLLOUT SWITCH IS RESETAND MAIN POWER IS INTERRUPTED OR

THERMOSTAT IS CYCLED OFF/ON FOR 1 SEC. MINIMUM.

YES

THERMOSTAT DEMAND SATISFIED.

LED: ON STEADY

COMB. AIR INDUCER CONTINUES 15‐SECONDPOST PURGE AFTER T'STAT DEMAND IS SATISFIED.INDOOR AIR BLOWER COMPLETES SELECTED “OFF”

DELAY BEFORE SHUTTING OFF.

YES

YES

IS VOLTAGE ABOVE 90 VOLTS?

LED: ON STEADYUNTIL VOLTAGE ISABOVE 95 VOLTS,THEN RESTARTS

HEATINGSEQUENCE.

NO

YES

YES

YES

NO

NO

NO

NO

NO

NO

YES

YES

NO

NO

NO

YES

YES

NO

4‐SECOND TRIAL FOR IGNITION.GAS VALVE OPENS.

HAS PRESSURE SWITCH OPENED 5TIMES IN THE SAME HEAT DEMAND?

NO

1 HRPRESSURE

SWITCHWATCHGUARD

MODE

5 MINUTE WATCHGUARD MODE.HAS LIMIT SWITCHED CLOSED

AFTER 5 MINUTES?

YES

Page 25: ML180DF(X) - Dominion Energy

Page 25

Troubleshooting: Cooling Sequence of Operation

COOLING SEQUENCE OF OPERATION

NORMAL COOLING MODE ABNORMAL COOLING MODE

IGNITION CONTROL MAIN POWER ON. LED: ON STEADY

CONTROL SELF DIAGNOSTIC CHECK.IS CONTROL OPERATING NORMALLY?

YES

LED: 9 FLASHESCONTROL WILL CONTINUE TO CALL FOR COOLING

IN THIS CONDITION.

POWER ON

GAS VALVE OFF. COMBUSTION AIR INDUCER OFF.INDOOR BLOWER OFF WITH NORMAL DELAY.

LED: OFFINTERRUPT MAIN POWER TO RESET CONTROL.

YES

IS POLARITY CORRECT?

LED: ON STEADY.REMAINS UNCHANGED THROUGHOUT COOLING CYCLE.

THERMOSTAT CALLS FOR COOLING.

COMPRESSOR CONTACTOR AND SYSTEM FANENERGIZED WITH 2‐SECOND DELAY

(COOLING SPEED). EAC TERM. ENERGIZED.

COMPRESSOR OFF.

THERMOSTAT OPENS.

SYSTEM FAN AND EAC TERM. OFFWITH 60‐SECOND DELAY.

NO

NO

IS VOLTAGEABOVE 90 VOLTS?

LED: ON STEADY.CONTROL WILL CONTINUE TO CALL FOR

COOLING IN THIS CONDITION.

YES

NO

IS THERE A PROPER GROUND?

YES

NO LED: ON STEADYCONTROL WILL CONTINUE TO CALL FOR COOLING

IN THIS CONDITION.

Page 26: ML180DF(X) - Dominion Energy

Page 26

Troubleshooting: Continuous Fan Sequence of Operation

CONTINUOUS FAN SEQUENCE OF OPERATION

LED: ON STEADYMANUAL FAN SELECTION MADE AT THERMOSTAT.

CONTROL (G) ENERGIZES SYSTEM FAN ON CONTINUOUSBLOWER SPEED. EAC TERMINAL IS ENERGIZED.

THERMOSTAT CALLS FOR HEAT (W).

THERMOSTAT CALLS FOR COOLING.

THERMOSTAT OPENS.SYSTEM FAN SWITCHED TO COOL SPEED.

EAC TERM. REMAINS ON.

THERMOSTAT OPENS.

MANUAL FAN SELECTION MADE AT THERMOSTAT.CONTROL (G) ENERGIZES SYSTEM FAN ON

CONTINUOUS BLOWER SPEED.

NO YES

YESNO

HUM TERM. ENERGIZES WITH COMB. AIR INDUCER.

SYSTEM FAN SWITCHES TOHEATING SPEED.

SYSTEM FAN SWITCHES TOCONTINUOUS BLOWER SPEED

.

HUM TERM. DE-ENERGIZES WITH COMB. AIR INDUCER

Page 27: ML180DF(X) - Dominion Energy

Page 27

VIII- TWINNING

Twinning 2 ML180DF Furnaces

The control board in this furnace is equipped with a provi­

sion to ”twin” (interconnect) two(2) adjacent furnaces with a

common plenum such that they operate as one (1) large

unit.

When twinned, the circulating blower speeds are synchro­

nized between the furnaces. If either furnace has a need to

run the blower, both furnaces will run the blower on the

same speed. The cooling speed has highest priority, fol­

lowed by heating speed and fan speed.

Field installation of twinning consists of connecting wires

between the ”C” and ”Twin” terminals of the two controls.

The 24 VAC secondary of the two systems must be in

phase. All thermostat connections are made to one control

only. Figure 20 show wiring for two-stage and single stage

thermostats.

The twinned furnace without thermostat connections is to

have the call for heat supplied by an external 24VAC isola­

tion relay to prevent its rollout switch from being bypassed

by the other twinned furnace. The coil of the isolation relay

connects from the thermostat ”W” to 24 VAC common. The

contacts of the relay connect ”R” to ”W” on the non-thermo­

stat twin.

FIGURE 20

Y

W

C

Y

W

R

R

G

C

G

TWIN

TWIN

TWIN 2

TWIN 1

ISOLATIONRELAY

TWO-STAGE THERMOSTAT

Call For Cool

Call For Fan

Call For 1stStage Heat

Call For 2ndStageHeat

R

Y

G

W1

W2

Y

W

C

Y

W

R

R

G

C

G

TWIN

TWIN

TWIN 2

TWIN 1

ISOLATIONRELAY

Call For Cool

Call For Fan

Call For Heat

R

Y

G

W

SINGLE STAGE THERMOSTAT

FIELD WIRING FOR TWINNING THE ML180DF