24 October 2016Copyright © 2016 Pacific Star Communications
Imagined. Engineered. Delivered.®
Military Networking Lessons Learned –Enabling Industrial Remote Monitoring
Remote 2016 Monitoring & ControlLas Vegas, NVNovember 4, 2016, 1:30 PM
Charlie Kawasaki, CISSPCTO, PacStar
24 October 2016Copyright © 2016 Pacific Star Communications 2
Imagined. Engineered. Delivered.®
Non-stop IT Growth Potential for Remote/ICS systems: No Surprise Here● Military Benefits
− Situational awareness− Mission command/control− Resupply, maintenance
● Military opportunities for IT− Military enterprise management (including facilities)− Vehicle integration for EW, ISR, mission, and vehicle
management and control (Vetronics)− In transit, mobility and dismounted soldier comms− Coalition partner comms− Tactical microgrids
24 October 2016Copyright © 2016 Pacific Star Communications 3
Imagined. Engineered. Delivered.®
Example System: US Army VICTORY Program
http://www.geautomation.com/news/ge-contributes-armys-victory-industry-group
24 October 2016Copyright © 2016 Pacific Star Communications 4
Imagined. Engineered. Delivered.®
Military Fielded Systems: Rising Complexity● Over time, fielded system
complexity continues to rise− Unified capabilities− Application virtualization− Added networks (SIPRNet,
NIPRNet, CENTRIXS, JWICS, Coalition, NGOs)
− Wireless meshing, cellular, LoS comms
− CSfC/Suite B− Increased IA demands
Cyber defense● System challenges grow
geometrically− SWaP− Setup time/down time− Training
24 October 2016Copyright © 2016 Pacific Star Communications 5
Imagined. Engineered. Delivered.®
Similar Opportunities/Challenges: Oil and Gas
Drilling Rig Network: Networks on drilling rigs must be reliable under industrial conditions, efficient over limited bandwidth links, and easy to manage either centrally or locally. Drilling rig networks must support wired and wireless connectivity for web access, data instrumentation capture, telemetry, and real-time video streaming.
Production Monitoring: Production operations must be monitored at various points throughout the production processes including at wellheads, along various points of pipelines, and at gas compressor stations.
24 October 2016Copyright © 2016 Pacific Star Communications 6
Imagined. Engineered. Delivered.®
Similar Opportunities/Challenges: Mining
Underground “Last Mile’ Applications: The most difficult operations in underground mining. There are a number of challenges in this part of mining where fixed infrastructure is not supported and the only means of communication is via RF/wireless technology.
Environmental Monitoring: Solutions enable continuous monitoring of priority systems and metrics such as gas levels, air flow, ventilation fans, water pumps and power status. Solutions can support the collection of data for micro-seismic analysis to monitor rock mass response during mine excavation.
24 October 2016Copyright © 2016 Pacific Star Communications 7
Imagined. Engineered. Delivered.®
Similar Opportunities/Challenges: Rail
Wayside Bungalow Networking: When a rail transportation company must connect thousands of wayside bungalows to a network, security, ease of management, and reliability of the equipment is critical.
Positive Train Control: Onboard train networking equipment must communicate with wayside equipment or to operational network infrastructure reliably and securely with a low level of latency. Additionally, all onboard network equipment must be compact and able to operate in a harsh environments with a high degree of reliability.
24 October 2016Copyright 2016 Pacific Star Communications
Imagined. Engineered. Delivered.®
Enhanced COTS-Based Modular Communications Solutions
24 October 2016Copyright © 2016 Pacific Star Communications 9
Imagined. Engineered. Delivered.®
Example Remote Network System*
● Satcom modem● Enterprise branch office router● Enterprise branch office
VPN/Firewall● Enterprise Server(s)● Enterprise Switch● WiFi System● UPS
* Example from undisclosed oil exploration ship
24 October 2016Copyright © 2016 Pacific Star Communications 10
Imagined. Engineered. Delivered.®
Challenges of a Data Center at the Frontier
● Suitability: Data center equipment is not suitable for a rugged environment that is typical for industrial applications, particularly for installations at the frontier.
● Less Reliability: Data center equipment is also more prone to failure when installed at the frontier.
● Power Conditioning & UPS: Power conditioning is critical since power is generated at the site and is “dirty” and intermittent at the frontier. If data center type equipment is used, additional power conditioning and UPS equipment become necessary.
● Bulky Equipment: The equipment is bulky and expensive to ship to the operational area but also to move on and off the offshore rig.
● Rackmount Hardware: Rackmount hardware is difficult to procure at the frontier.
24 October 2016Copyright © 2016 Pacific Star Communications 11
Imagined. Engineered. Delivered.®
Small Form Factor Solutions (SFF) Save SWaP
● 10.4 times lighter than a typical 1ru server● 12.4 times smaller than a typical 1ru server● Up to 18 times less power consumption
24 October 2016Copyright © 2016 Pacific Star Communications 12
Imagined. Engineered. Delivered.®
Example: Military Next Gen Network System
Reduced Size, Weight and Power (SWaP) with no loss of comms network functionality:● SFF satcom system● SFF branch office router● SFF branch office
VPN/Firewall● SFF Server(s)● SFF Switch● SFF WiFi System● UPS
24 October 2016Copyright © 2016 Pacific Star Communications 13
Imagined. Engineered. Delivered.®
8 Step Process for Re-Engineered COTS
1. Start with best of breed, enterprise COTS and or embedded COTS boards
2. Strip down3. Qualify thermal and other environmental performance4. Design/Replace power system5. Re-package6. Solution package7. System validation/verification8. 100% system QA during MFG
24 October 2016Copyright © 2016 Pacific Star Communications 14
Imagined. Engineered. Delivered.®
Example: Thermal Re-engineering
Color Scale 25 – 45 C Color Scale 25 – 45 C
Re-engineered Cooling System
OEM, Commercial cooling system
~ 20C Reduction in Hot Spot Temperature
24 October 2016Copyright © 2016 Pacific Star Communications 15
Imagined. Engineered. Delivered.®
Example: Ruggedized, Compact Rail Solution
Example Space-Constrained Rail Wayside Location
Mandatory PCT creates networking challenges. Solution: deployable SFF server for network monitoring and comms.
Uses re-engineered COTS server module with virtualized network monitoring software and voice/PTT/RoiP
24 October 2016Copyright © 2016 Pacific Star Communications 16
Imagined. Engineered. Delivered.®
Example: Oil and Gas Solution
Capture
Real-Time Data and Network
Process
Visualize
Decision
24 October 2016Copyright © 2016 Pacific Star Communications 17
Imagined. Engineered. Delivered.®
Example: Oil and Gas Solution
24 October 2016Copyright © 2016 Pacific Star Communications 18
Imagined. Engineered. Delivered.®
SFF: Detailed Comparison
Commercial Server● Size: 19” x 17.1” x 1.68”
Vol: 547 in3
● Weight: max 42.55 lb. ● Power: 350 – 550w AC● Temperature Range:
10°C to 35°C (50°F to 95°F)
Small Form Factor Server● Size: 5.3” x 7.1” x 1.6”
Vol: 60.2 in3
● Weight: 2.5 lb.● Power: 45w AC● Temperature Range:
-20°C to 60°C (-4°F to 140°F)
Makes practical virtualized applications in the field
24 October 2016Copyright © 2016 Pacific Star Communications 19
Imagined. Engineered. Delivered.®
Example: Small Router Module● Supports multiple input power scenarios for
flexible operations.− Snap on Radio Batteries (PRC152/PRC148).
Dual battery configuration enables hot swap without down time.
5 hour run time per battery (No PoE or external device load)
− Wide Range DC (10 – 36 VDC) for 2590 batteries, vehicle power, and other DC power sources.
− World Wide AC
● Cisco 5915 ESR Router with PoE− 12W PoE standard, 60W when provided external 48
VDC
● Fanless and environmentally rugged (-20 to 70C)− Extensively Tested to MIL-STD 801G (Operating
Temp, Vibration, Shock, Humidity, Sand/Dust) and MIL-STD-461F EMI
● 5.3” X 7.1” X 1.6”, 2.3 lbs.
24 October 2016Copyright © 2016 Pacific Star Communications 20
Imagined. Engineered. Delivered.®
Example: Small, Powerful Server Module● With a generic server module running a
hypervisor such as Vmware ESXi, Hyper-V, KVM, a whole new world of options for SFF networking becomes available. Examples include:− Routing – such as Cisco 5921 and CSR
100v or Brocade vRouter− Firewalls/IDS/VPN – such as Palo Alto
Networks− WAN Optimization – such as Riverbed
Virtual Steelhead− Wireless Controllers – such as Aruba VMC− Voice/RoIP Control – such as Cisco UCM
24 October 2016Copyright © 2016 Pacific Star Communications 21
Imagined. Engineered. Delivered.®
Example: Virtualization● Multiple input power scenarios for flexible
operations− Snap on Radio Batteries (PRC-152/PRC-
148) Run time dependent on configuration
− Wide Range DC (10 – 36 VDC) − World Wide AC
● Provides conditioned 12VDC output power to operate KG-250X
● Extensively Tested to MIL-STD 801G (Operating Temp, Vibration, Shock, Humidity, Sand/Dust) as well as FCC EMI
● 5.3” X 7.1” X 1.6”, 2.7 lbs.● Two Solid State Disk Drive Configurations
(SATA 2/3, 6 Gb/s)− Dual 1.8” Form Factor, up to 1 TB total− Single 2.5” Form Factor, up to 4 TB total
24 October 2016Copyright © 2016 Pacific Star Communications 22
Imagined. Engineered. Delivered.®
● Provides hyper-converged storage, compute and networking capabilities in ultra-low SWaP module for multiple applications and use cases.
● Key features:− High capacity RAID protected
storage (up to 32 TB of SSD storage – with 8x 2.5” SSD
− High performance compute (Intel Xeon E3 processor with up to 32 GB RAM)
− High density port count (5 routable GigE ports, 1 x USB, 1 x Full Display Port, 1 x Console)
Example: Hyper-Convergence Module
24 October 2016Copyright © 2016 Pacific Star Communications 23
Imagined. Engineered. Delivered.®
Example: Compact Transport and Mounting
Rack Mount
Mini-Transit Case
Custom Kits
24 October 2016Copyright © 2016 Pacific Star Communications 24
Imagined. Engineered. Delivered.®
Still Must Meet MIL-STD-810G/461F TestingAll tests conducted at independent, accredited test labs• Defense Logistics Association
Certification• American Association for
Laboratory Accreditation (A2LA)
• International Safe Transit Association Certification (ISTA)
Operational tests include running IP traffic through the UUT and monitoring for drop outs, errors, or other signs of degradation
Test Description Test Method Parameters ResultMIL-STD-810G
High Temperature Operation
MIL-STD-810GMethod 501.5Procedure II 70C Operating Pass
Low Temperature Operation
MIL-STD-810GMethod 502.5Procedure II -20C Operating Pass
High Temperature Storage
MIL-STD-810GMethod 501.5Procedure I 85C Non-operating Pass
Low Temperature Storage
MIL-STD-810GMethod 502.5Procedure I -50C Non-operating Pass
Vibration Operation
MIL-STD-810GMethod 514.6Procedure I
Rotary Wing Aircraft (CAT 14, Figure 514.6D-3/Table 5114.6D-III) Pass
Vibration Operation
MIL-STD-810GMethod 514.6Procedure I
Off Road Ground Vehicle(MIL-STD-810F, Figure 514.5C-3) Pass
ShockBench Handling
MIL-STD-810GMethod 516.6Procedure VI Per Procedure Pass
Sand and DustBlowing
MIL-STD-801GMethod 510.5Procedure I & Procedure II
Dust 15mph Wind & 10 g/m^3Sand 30 mph Wind Pass
Sand and DustSettling Dust
MIL-STD-810FMethod 502.5Procedure II Per Procedure Pass
HumidityMIL-STD-810GMethod 507.5 Temperature and Humidity Cycles Pass
MIL-STD-461F (EMI)Radiated Emmisions RE102-4 Ground Application (Navy Fixed, Air Force) PassConducted Emmissions CE102-1 All Applications Pass
24 October 2016Copyright © 2016 Pacific Star Communications 25
Imagined. Engineered. Delivered.®
Example Lab Test, Transportation Vibration
24 October 2016Copyright © 2016 Pacific Star Communications 26
Imagined. Engineered. Delivered.®
Example: 100% MFG QA
24 October 2016Copyright 2016 Pacific Star Communications
Imagined. Engineered. Delivered.®
Software: The COTS Challenge
24 October 2016Copyright © 2016 Pacific Star Communications 28
Imagined. Engineered. Delivered.®
Problem: Management Challenges● Typical:
− Multiple vendor user interfaces
− Extensive training requirements
− Complex and error-prone configuration
− Long setup times● These solutions require:
− Multiple IT professionals to deploy in the field
− High training expense
24 October 2016Copyright © 2016 Pacific Star Communications 29
Imagined. Engineered. Delivered.®
Solution: Integrated GUI
● An intuitive user interface− Set-up and operation quick and easy to learn − Significantly fewer mis-configuration errors.
● Powerful wizards and alerts− Common user interfaces across all hardware and software components − Automates complex and routine tasks
● Interoperability− Supports a broad range of tactical and enterprise communications
hardware and systems− Enables easy, consistent operation even with upgrade and replacement
of system components.● An extension of advanced IP-enabled unified communications
− Voice, video, data sharing, etc. at the edge− Without an increase in complexity of operation.
● Vendor agnostic remote management.
24 October 2016Copyright © 2016 Pacific Star Communications 30
Imagined. Engineered. Delivered.®
Integrated GUI: Saves Time/Reduces Errors
* Validated through independent testing of military communications specialists, civilian IT administrators and non-IT military and civilian users.
24 October 2016Copyright © 2016 Pacific Star Communications 33
Imagined. Engineered. Delivered.®
Wizard Advantages● Common look-and-feel● Easy to follow, step-by-step
procedures● Task-centric view, cuts across
multiple devices from different manufacturers
● Context-sensitive help● Administrator customizable
default values, ability to hide pages
24 October 2016Copyright © 2016 Pacific Star Communications 34
Imagined. Engineered. Delivered.®
Integrated GUI: Already In-Use In DoD Programs● Onboard dozens of US DoD platforms● 6,000 copies deployed in US Army WIN-T● In field exercises with US Army Wireless Command Post
WIN-T/Ft. Gordon User Jury, Feb 2016● “Even users who have not touched the system can perform basic
troubleshooting methods.”● System capabilities are user friendly.”● “Two thumbs up, we really need this in the field. From RTO in
combat team line units down to ESB supporting other networks.”From several PFC MOS 25B, 25A, as well as contractor reps from WIN-T Inc 1
24 October 2016Copyright 2016 Pacific Star Communications
Imagined. Engineered. Delivered.®
Questions?
Thank You!