micro lighting inverter - iepiepsys.com/wp-content/uploads/2018/10/imp-imp-m-catalog.pdforder...

9
Micro Lighting Inverter

Upload: others

Post on 28-Jun-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

Micro Lighting Inverter

Page 2: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

MODEL # MOUNTINGDC Voltage

12V

S = SERIESSP = SERIES PARALLEL

Input/Output Voltage

IMP-M 50 T Grid 12V S 120 V

IMP-M 50 Recessed 12V S 120 V

IMP-M 50 Surface 12V S 120 V

IMP-M 100 T Grid 12V SP 120 V

IMP-M 100 Recessed 12V SP 120 V

IMP-M 100 Surface 12V SP 120 V

IMP 150 Surface 12V P 120 V

IMP 200 Surface 12V P 120 V

IMP 300 Surface 12V P 120 V

IMP 400 Surface 12V P 120 V

IMP 600 Surface 12V P 120 V

1

• Apartments/Condominium Complexes

• Assisted Living Centers• Banks, Financial• City, County, State, Federal

Buildings• Grocery Stores• Hospitals• Hotels• Medical Offices• Military Complexes

• Movie Theaters• Office Buildings• Race Tracks• Train, Subway, Bus Stations• Religious Facilities• Restaurants• Department Stores• Schools, Colleges• Shopping malls• Superstores

APPLICATIONS

RATINGS TABLE

IMP/IMP-M Series Modified Sine Wave

Page 3: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

2

IMP-M-S 15”W X 4.75”D x 9”HIMP-M-T 24”W X 5”D x 6.5”HIMP-M-R 17.5”W X 4.5”D x 11.5”H

Dimensions

Surface Mount Surface Mount

T Grid

Recessed Wall

Systems

24”5”

4.5”17.5”

6.5”

11.5”

9”

13.5”

15”

15”

4.75”

Page 4: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

System Overview:The IMP series lighting inverter from IEP Sys-tems is designed to provide 120 VAC 60hz power to emergency lighting in the event of a power failure or brownout situation.

Constructed with heavy duty steel in white powder coat paint, the IMP is housed in a vari-ety of cabinet configurations.

The line voltage output allows the remote fixture to be located up to 1000 feet away from the unit.

Each systems is designed with on-field selec-tion of wires to ensure an easy installation.

IMP series inverter employs sealed, mainte-nance-free* VRLA batteries with a design life of 10 years per battery manufacturer guidelines.

Product is tested and listed UL924

*VRLA do not need to be watered. Periodic checks, coupled with standard record keeping and maintenance of the inverter would ensure the longevity of the battery module.

3

Operating Parameters:Operating temperature: 32F (0C) – 104F (40C)Running time: minimum of 90 minutes at rated capacity.Power Factor: .9 leading to .9 laggingInverter efficiency: >85%

IMP will provide full rated VA output from .9 leading to .9 lagging power factor. Loads outside of this power factor will reduce the total output of the unit depending on the power factor.

*we recommend that only Energy Star recognized compact fluorescent or LED lamps be used with this equipment.

Theory Of Operation:The IMP inverter can be operated in three differ-ent configurations.

1. Normally Off; The connected loads will only come on when the utility power fails or during test mode.

2. Normally On: The connected loads will always be on. During power failure, the connected load will automatically transfer to inverter power and remains on.

3. Switched/On: The connected loads may be controlled by local switching and can be turned on and off depending on the state of the local switch. In the event of a power failure or during emergency mode, the connected loads auto- matically switch to inverter power and bypasses the local switch and turns the lights on.

IMP/IMP-M Series Modified Sine Wave

Page 5: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

Order Information

4

IMP Series

IMPIMP Series

Micro Lighting Inverter

Mounting

MountingSurfaceT-Grid

Recessed

600

Watts36W50W100W150W200W300W400W600W

120

AC Input/Output

120V/120V

* Consult factory for additional configurations or options.

A: PO Box 20302 Lehigh Valley PA 18002 | V: (610) 628 1488 | W: www.iepsys.com | E: [email protected]

Page 6: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

5

White powder coat paint

For modern day electrics closet with limited provision for energy lighting system.

IMP/IMP-M Series Modified Sine Wave

OVERVIEW:

Page 7: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

6

Rugged construction out of heavy gauge steel

Unobtrusive

*Available in various mounting configurations

Page 8: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

Specifications:Furnish and install IEP Systems’ Emergency Light-ing System known as IMP Series with rated capac-ity of ___ watts. The system shall be listed to UL 924 standard.

Equipment and accessories furnished under the term of this specification shall be the standard product of a single manufacturer and shall be equal in all respects to those supplied by IEP Sys-tems. Catalog numbers and model designations which herein indicate design, quality and the type of materials as well as required operating charac-teristics. All equipment shall be in compliance with applicable standards and codes.

The connected loads shall be powered normally by utility input and upon failure of the utility power, the load shall automatically by powered by IMP Series Inverter’s battery and inverter for a minimum of 90 minutes. Upon restoration of utility power, the system will automatically reconnect the load to the utility power and recharge the battery.

*The IMP Series Inverter will be capable of power-ing any combination of incandescent, fluorescent, and LED loads. The combined load on the system cannot exceed the rated power rating.

The IMP Series Inverter will automatically revert to emergency inverter operation in the event the aver-age utility AC voltage fall below 85% of the nominal line voltage.

During emergency operation, output voltage will be within +/- 5% of nominal at full load for the entire duration of the specific discharge period.

During emergency operation, the system will be powered by sealed, recombination batteries. The batteries will be encased in a high impact, heat resis-tant container with a permanently sealed cover. The battery will have a minimum design service life of no less than 10 years.

A low voltage disconnect circuit designed to reduce battery discharge during extended power outages and will disconnect the inverter when the battery volt-age drops below acceptable level.

The system will have a manual testing switch for manual testing, AC on, Charging and Emergency power pilot lights for system status.

Page 9: Micro Lighting Inverter - IEPiepsys.com/wp-content/uploads/2018/10/IMP-IMP-M-catalog.pdfOrder Information 4 IMP Series IMP IMP Series Micro Lighting Inverter Mounting Mounting Surface

IEP Systems A PO Box 20302 Lehigh Valley PA 18002 P tel.:(610) 628 1488 W website: www.iepsys.com E e-mail: [email protected]

CONTACT US

Systems

IMP/IMP-MSeries