01 Protection Relays The MiCOM range of relays offers varying levels of functionality and hardware options to best suit the protection requirements, and allows the customer to choose the most cost effective solution for their application. The 20, 30 and 40 series hardware platforms are the building blocks of the MiCOM protection relay range providing the capability for a wide variety of protection, control, measurement, monitoring and communication functions. The versatile hardware allows for application in many installations and a common relay management software (MiCOM S1) makes for easy configuration and application. A standard and simple user interface across the range makes this ideal in any environment, from the more complex bay level control and mimic to the more simple LCD display and interrogation facility. Numerous integrated communication protocols allow easy interfacing to most substation control or SCADA systems. The majority of MiCOM 30 and 40 series relays can be supplied with ethernet, to allow a full IEC 61850 solution for the substation. THE MICOM RANGE OFFERS COMPREHENSIVE PROTECTION SOLUTIONS AT ALL POWER SYSTEM LEVELS SUCH AS : Generation Integrated Generator Protection Transmission and Distribution Distance Protection Line Differential Transformer Management Busbar Protection Stand Alone Breaker Fail Protection Directional/Non-Directional Overcurrent Feeder Management and One Box Solutions Loadshedding Voltage & Frequency Protection Industrial Motor Management Interconnection Protection Railway Feeder Management Transformer Management Distance Protection MiCOM Protection 20, 30 and 40 Series Relays Key Features Customer Benefits One single configuration software - MiCOM S1 1A/5A dual rated inputs Scalable hardware Flexible mounting options Standardized user interfaces Wide range of communication protocols

Upload: vuanh

Post on 02-Jan-2017

356 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MiCOM Protection

01Protection Relays

The MiCOM range of relays offers varying levels of functionality and hardware options to best suit the protection requirements, and allows the customer to choose the most cost effective solution for their application.

The 20, 30 and 40 series hardware platforms are the building blocks of the MiCOM protection relay range providing the capability for a wide variety of protection, control, measurement, monitoring and communication functions.

The versatile hardware allows for application in many installations and a common relay management software (MiCOM S1) makes for easy configuration and application.

A standard and simple user interface across the range makes this ideal in any environment, from the more complex bay level control and mimic to the more simple LCD display and interrogation facility.

Numerous integrated communication protocols allow easy interfacing to most substation control or SCADA systems. The majority of MiCOM 30 and 40 series relays can be supplied with ethernet, to allow a full IEC 61850 solution for the substation.

THE MICOM RANGE OFFERS COMPREHENSIVE PROTECTION SOLUTIONS AT ALL POWER SYSTEM LEVELS SUCH AS :Generation

• IntegratedGeneratorProtection

TransmissionandDistribution

• DistanceProtection• LineDifferential• TransformerManagement• BusbarProtection• StandAloneBreakerFailProtection• Directional/Non-DirectionalOvercurrent• FeederManagementandOneBoxSolutions• Loadshedding• Voltage&FrequencyProtection

Industrial

• MotorManagement• InterconnectionProtection

Railway

• FeederManagement• TransformerManagement• DistanceProtection

MiCOM Protection20, 30 and 40 Series Relays Key Features

Customer Benefits•One single configuration

software - MiCOM S1•1A/5A dual rated inputs•Scalable hardware•Flexible mounting options•Standardized user interfaces•Wide range of communication

protocols

Page 2: MiCOM Protection

02MiCOM Px20, Px30, Px40Protection Relays

KEY FEATURESTheMiCOMrangeofrelaysfulfilstherequirementsatallvoltagelevelsfromLVtoEHVforIndustrial,DistributionandTransmissionSystems.

COMMON FEATURES

• 1A/5AdualratedCT’s

• EventandDisturbanceRecording

• Variouscasingandmountingoptions

• RelayshaverearRS485portwithchoiceofprotocolsandfrontRS232forlocalsetting

• Anumberofauxiliarysupplyanddigitalinputvoltageoptions

20SeriesRelays(Px2x)

Itwillfulfilthebasicrequirementsofindustrial,transmissionanddistributionsystemsprovidingsimplicityandeaseofapplicationinawiderangeofinstallations.

• Scalablesolutionswheretypeandquantityofprotectionfeaturesismodeldependent

• Flexiblelogicequationsavailableonmostmodels

• Compacthardwareoptionsforeasyinstallation

• Commonfunctionsthroughouttherange

• Multi-languageHMI

• AdvancedprotectionfunctionsonPhase2hardware

30SeriesRelays(Px3x)

DesignedtomeettherigorousrequirementsofMV,HVandEHVsystemswithparticularfocusonfeederandtransformerprotectionandcontrol.

• ProtectionwithBaylevelcontroloptionstofacilitatefeedermanagement

• Input/Outputquantityselectablebasedonrequirements

• AnumberofRearPorthardwareoptionsavailablewithawiderangeofProtocolsselectableviasoftware

• Protectionfunctionsavailableforunearthed/petersencoilearthedsystems

• Surfaceandflushmounted(incudingdetachableHMIoption)aswellascompactcasemodelsavailableintherange

• FullProgrammableSchemeLogicandFunctionkeys

40SeriesRelays(Px4x)

ItwillfulfiltheprotectionrequirementsforawidemarketofMV,HV,EHVandindustrialsystemsandoffersawiderangeofprotectionfunctions.• FullProgrammableSchemelogicavailable

withGraphicConfigurationToolforeasysetting

• ScalableInput/Outputhardwaredependingonrequirements

• OperatingvoltageselectableviaSoftwareforOptoinputs

• Hardwareaccessoriesavailableforeasymountinginracksorpanels.

APPLICATIONS

Px2xSeries

Theintegratedfunctionsreflectthedifferentrequirementsinsystemprotection.Thepreferredapplicationsareasfollows:• P12x:UniversalOvercurrentprotectionfor

mainorback-upprotectiononMVandHVsystems

• P22x:MotorProtectionSeriesforLVandMVsystems

• P52x:LineDifferentialprotectionforMVandHVsystemswithmultiplecommunicationoptions

• P821:DedicatedBreakerFailureProtectionsuitableforEHV,HVandMVsystems

• P92x:Voltageandfrequencyprotectionsuitableforgenerators,motorsandfeeders

Px3xSeries

30Seriesprotectiondevicesprovideawiderangeofprotectionandcontrolfunctionsmeetingstringentmarketsegments.Therangeisespeciallysuitableforpetersencoilearthingrequirements.Thepreferredapplicationsare:• P13x:Feedermanagementrelaysandone

boxsolutionforMVandHVsystems(includingrailwayfeeder)

• P43x:DistanceprotectionforMV,HVandEHVsystemsandrailcatenaryrequirements

• P53x:LinedifferentialprotectionforMVandHVsystems

• P63x:Differentialprotectionfortransformers,generatorsandmotors(includingrailwaytransformers).

Page 3: MiCOM Protection

03MiCOM Px20, Px30, Px40Protection Relays

Px4xSeries

40Seriesprotectiondevicesprovideawiderangeofprotectionandcontrolfunctionsandmeetstherequirementsofawidemarketsegment.Thepreferredapplicationsare:• P14x:Feedermanagementrelaysuitablefor

MVandHVsystems

• P24x:RotatingMachineManagementrelayforapplicationonawiderangeofsynchronousandinductionmachines

• P34x:Generatorprotectionforsmalltosophisticatedgeneratorsystemsandinterconnectionprotection

• P44x:FullschemeDistanceprotectionrelaysforMV,HVandEHVsystems.

• P54x:LineDifferentialprotectionrelaysforHV/EHVsystemswithmultiplecommunicationoptionsaswellphasecomparisonprotectionforusewithPLC.

• P74x:NumericalBusbarprotectionsuitableforapplicationonMV,HVandEHVbusbars

• P94x:Frequencyprotectionforloadshedding,loadrestorationandgeneratorabnormaldetection

CONTROLProgrammableschemelogic

Simplelogicequationsaswellasblocklogicisavailableinanumberof20seriesrelays,seefigure1.Powerfulgraphicallogicavailableinthe30and40seriesrelaysallowstheusertocustomizetheprotectionandcontrolfunctionsoftherelay.Itisalsousedtoprogramthefunctionalityoftheopto-isolatedinputs,relayoutputs,LEDanduseralarms.TheProgrammableSchemeLogiccanbeusedtoimplementadditionalsupervisionfeatures,suchastripcircuitsupervisionorimplementcomplexlogicsuchasfrequencyrestorationschemes.Schemeshavebeendevelopedcapableofsupervisingthetripcoilandcircuitwiththecircuit

breakeropenorclosed.ThePx40gatelogicincludesOR,AND,NOTandmajoritygatefunctions,withtheabilitytoinverttheinputsandoutputs,andprovidefeedback.Anumberofgeneralpurposelogictimersarealsoavailableaswellasthosetimersusedtoconditiontherelaycontacts.Thesystemisoptimized(eventdriven)toensurethattheprotectionoutputsarenotdelayedbythePSLoperation.TheProgrammableSchemeLogicisconfiguredusingthegraphicalMiCOMS1PCsoftware,asshowninFigure2ThePx30logiccanbecreatedusingBoolean

Figure3,ProgrammablelogicforPx30

Figure2,ProgrammablelogicforPx40

Figure1,FlexiblelogicforPx20

Equationsoragraphicalinterfaceasshowninfigure3.

IndependentProtectionSettingsGroups

Uptotwosettinggroupsaresupportedinthe20Serieswhereasthe30and40seriescanofferuptofourindependentsettinggroups.Thesecanbeactivatedlocally,remotelyorviaadedicatedinputandareusedtoallowfordifferentsystemoperatingconditionsandwhereadaptiverelayingisapplied.

Page 4: MiCOM Protection

04MiCOM Px20, Px30, Px40Protection Relays

Measurement&PostFaultAnalysis

TheMiCOMRangeofrelaysarecapableofmeasuringandstoringawiderangeofsystemquantitiessuchasCurrent,Voltage,Frequency,Poweretc.dependingontherelayfunctionality.Allevent,faultanddisturbancerecordsaretimetaggedtoaresolutionof1msusingtheinternalrealtimeclockandarestoredinnon-volatilememory.Asupervisedlithiumbatteryensuresthattherealtimeclockandrecordsaremaintainedduringauxiliarysupplyinterruptions.WhererelaysarecommunicatingtoaSCADAsystem,theprotocols’telegramscanbeusedforexternaltimesynchronizationoralternativelyanoptionalIRIG-BportisavailableforaccuratetimesynchronizationonallPx30andPx40MiCOMrelays.Somerelayscanalsouseanoptoinputtosynchronizetherelay’sclock.

PowerSystemMeasurement

Acomprehensivesetofmeasurementvaluesincludinginstantaneousandderivedvaluesareavailableontherelays.ThesemeasuredvaluescanbedisplayedonthefrontLCDdisplayortransferredlocallyorremotelyaspertheuserrequirements.

POST FAULT ANALYSISEventrecords

Thesearegeneratedforstatuschangestologicinputsandoutputs,modificationstooneormoresettingparametersandalarmsignals.Alleventsaretime-taggedandstoredinchronologicalorderinacyclicmemorywheretheoldestrecordisoverwrittenoncetherelay’smaximumeventcountisexceeded.ThesearereadilyavailableforviewingontheLCD,orextractionviathecommunicationports.

Figure4,OscillographyanalysisusingMiCOMS1SoftwareforOptimumresults

Figure5,Atypicalsubstationcontrolsystem

Faultrecords

Atleast5recordsaresupportedonallrelaysandforeveryfault,thefollowinginformationiscapturedintherelayrecords• Afaultnumber• Thedateandtime• Theactivesettinggroup• Thefunctionthatissuedthetrip• Themagnitudeofthecurrent/voltagethatgave

risetothetripcommand

Disturbancerecords

Theinternaldisturbancerecorderwillrecordthesampledvaluesofallanaloginputvariablessuchasphasecurrentsandvoltagesetc.whereapplicableduringafault.OscillographicanalysiscanbeperformedusingMICOMS1whichwillprovidethemeanstoquicklyanalyseanaloganddigitalsignalsonthesametime-scaleforconvenience.DisturbancerecordscanbeextractedfromtherelayviathecommunicationportsandsavedintheCOMTRADEformat.

RELAY COMMUNICATIONSAsstandard,afrontcommunicationportisavailableforlocalaccesstotherelay.Anauxiliaryrearcommunicationportisavailableasanoptiononrelaysprovidinganengineeringportforeasyaccesstosettings,recordsandmeasurementsforprotectionengineers.AmainrearcommunicationsportisalsoavailableforinterfacetoaSCADAsystem.Anumberofprotocolsareavailableasanoptionforthispurpose.(Seecorteccodeforeachrelay)

SCADAInterface

SCADAInterface

MasterClock(GPS)

IRIG-Bport

Modem(remoteaccess)

EAI232(localaccess)

Page 5: MiCOM Protection

05MiCOM Px20, Px30, Px40Protection Relays

LocalCommunication

ThefrontEIA(RS)232communicationporthasbeendesignedforusewiththeMiCOMS1softwareandisprimarilyforconfiguringtherelaysettingsandprogrammableschemelogic.Itisalsousedtolocallyextractevent,faultanddisturbancerecordinformationandcanbeusedasacommissioningtoolbyviewingallrelaymeasurementssimultaneously.InPx20/Px30thefrontEIA(RS)232isalsousedtoupgraderelaysoftware.InPx40aseparatefrontparallelportisusedforthis.

RearCommunication

TherearcommunicationportisbaseduponEIA(RS)485voltagelevelsandisdesignedforpermanentmultidropconnectiontonetworkcontrolanddataacquisitionsystems.Anoptionalfiberopticcommunicationsportisalsosupportedonthe30and40platforms.Ingeneral,thefollowingprotocolsareavailableatorderingorviasettingselectionontherelays.• Courier/K-Bus• Modbus• IEC60870-5-103• DNP3.0ThefollowingprotocolisonlyavailableonPx30/Px40relaymodelswithanEthernetportcurrently.• IEC61850Fig5illustratestheflexibilitywithwhichtheMICOMrangeofrelayscanbeintegratedintoaSCADAsystemaswellasprovideengineeringdataforremoteaccessbyutilityengineers.

USER INTERFACESTheuserinterfaceandmenutextareavailableinEnglish,French,GermanandSpanishasstandard.OtherlanguagessuchasforexampleRussianandItalianaresupportedonsomerelaysdependingonmarketrequirements.TheabilitytocustomizethemenutextandalarmdescriptionsarealsosupportedonPx30andPx40.

3

5

4

8

6 1

Figure6,Px40seriesuserinterface7

2

1

5

4

2

3

10

Figure7,Compactcaseuserinterface

7

3

2

6 1

9

5

4

8

Figure8,Px30seriesuserinterfacewithbaycontrol

Thefrontpaneluserinterfaces,asshowninFigures6,7&8comprise:(1)Aback-litliquidcrystaldisplay(20,30,40series)GraphicLCDdisplay(30seriesonly)(2)FourfixedfunctionLEDs(20,40series)FivefixedfunctionLEDs(30series)(3)UptoFouruserprogrammableLEDs(20series)UptoEightuserprogrammableLEDs(40series)TwelveuserprogrammableLEDs(30series)(4)Menunavigationanddataentrykeys.(5)“READ”and“CLEAR”keysforviewingandresetofalarms(6)Anuppercoveridentifyingtheproductname,whichmayberaisedtoviewfullproductmodelnumber,serialnumberandratinginformation.(7)AlowercoverconcealingthefrontEIA(RS)232port,download/monitorportandbatterycompartment.Covernotavailableoncompactcase.(8)Facilityforfittingasecurityseal(9)Baycontrolkeysupto6bayscontrol(30series)(10)ProgrammableFunctionkeys(compactrangeand30series)

Page 6: MiCOM Protection

06MiCOM Px20, Px30, Px40Protection Relays

SELF MONITORINGComprehensiveSelfmonitoringprocedureswithinthedeviceensurethatinternalhardwareandsoftwareerrorsaredetectedthusensuringahighdegreeofreliability.Automatictestsareperformedduringstart-upandacyclicselfmonitoringtestsareperformedduringoperation.Anydeviationsarestoredinnon-volatilememoryandtheresultofthefaultdiagnosisdetermineswhetherablockingofthedevicewilloccurorwhetheranalarmisonlyissued.

MECHANICAL DESCRIPTIONCases

TheMiCOMseriesrelaysarehousedinaspeciallydesignedcaseprovidingahighdensityoffunctionalitywithintheproduct.Communicationportsandmodel/serialnumberinformationisconcealedbyupperandlowercovers.Physicalprotectionofthefrontpaneluserinterfaceandpreventionofcasualaccessisprovidedbyanoptionaltransparentfrontcover,whichcanbefittedoromittedaccordingtochoice,sincethefrontpanelhasbeendesignedtoIP52protectionagainstdustandwaterThecasesaresuitableforeitherrackorpanelmountingasshowninFig.9.

Anoptionforsurfacemountingisalsosupportedonthe30seriesrangeandacompactcaseoptionisavailableonafew20and30seriesrelaysforinstallationswithspacelimitations.Takingintoaccountthedifferingcasewidths-relayscanbecombinedwithorwithouttheuseofstandardblankingplatestoformacomplete19”mounting.Thissavesspaceandallowsforaneatinstallation.

Wiring

ExternalconnectionsaremadeviaringtypeterminalonallMiCOMrelayexceptonthecompactcase.Thesetakepintypeterminalsalongwiththe30seriesrelaysasanoption.

P439

CG

GTRIP

ALARM

HEALTHY

EDIT MODE

X6

OUT OF SERVICE

F1

F2

F3

F4

GC

B

E

A

A

A

A (in

cludi

ng b

rack

ets)

C

D

B

F

B

D

GE

FRO

NT

VIE

WSI

DE

VIE

W

103240

(inc. wiring)270

(inc. wiring)157.5

177

155139,8223

166,4249,6

155.2156

213.4

260.2 253.6 177.5

184.5

434.8227.9

481.6

260.2

481.6257.1 177.5

206

240(inc. wiring)

309.6 270(inc. wiring)

177

413.2

483

157.5 max

294.4

175.6

253310

88.5 162.5 294.4

Note: Maximum sizes for guidance only, for specific product information please check the relevant product documentation. (All dimensions in mm)

In addition 24TE case variant available for P132 1)

1)

A

Typical case dimensions Table B C D E F G

20TE

Px20

30TE

40TE

40TE rack

84TE

84TE rack

40TE surface

Px30

84TE surface

40TE

60TE

80TEPx40

80TE rack

compact

Px20

C/

Px30

C

Compact incl . brack.

Figure9,Typicalcasedimensions

Page 7: MiCOM Protection

07MiCOM Px20, Px30, Px40Protection Relays

TECHNICAL DATAPowersuppliesAwiderangeofpowersupplyoptionsareavailableattheorderingstage.

DigitalInputsAwiderangeofoptoinputvoltagesaresupportedthroughouttherange

Nominal VoltageVnom.

Operate Range (V) DC AC

Px20 Ph 2

24-60Vdc 19.2-76Vdc -48-250Vdc48-240Vac 38.4-300Vdc 38.4-264

Vac

Px20 Ph 1

24-60DC 19.2-72 -48-150DC 38.4-180 -130-250DC100-250AC

104-300DC-

-80-275

125-250DC100-250AC

100-300DC-

-80-275AC

Px30 24DC48-250DC

19-2938-300

-100-230

Px4024-48DC 19-65 -48-125DC 37-150 24-110110-250 87-300 80-265

Auxiliary Voltage Digital Operating range (V)Px20Ph 2

24-250Vdc 19.2-300Vdc24-240Vac 19.2-264Vac

Px20Ph 1

24-60DC 15.2-60DC48-150DC 25.6-180DC130-250DC/100-250AC 38.4-300DC/38.4-275AC

125-250DC/100-250AC 84-174DC

48-150DC130-250DC

25.6-180(ACimmune)38.4-300(ACimmune)

Px30

ThresholdsStandardVariant>18(Uaux.24-250VDC)FurtherOptions>73V(67%ofUaux.110VDC)>90V(60-70%ofUaux.125/150VDC)>146V(67%ofUaux.220VDC)>155V(60-70%ofUaux.220/250VDC)

Px40Vmin/Vmaxthresholds

24/27,30/34,48/54,110/125and220/250(softwareselectable)

General Series Data Px20 Px20C Px30 Px30C Px40 Frequency50/60Hz X X X X XDualrated1A/5A X X X X XCTthermalratingscontinuous:4Inomfor10s:30Inomfor1s:100Inom

X X X X X

OptoInputs max8 max7 max.34 max2 max.24OutputContacts max9. max8 max46 max8 max.46Carry:continuous 5A 5A 5A 5A 10AMakeandcarry 30Afor3s 30Afor3s 30Afor0.5s 30Afor0.5s 30Afor3sLEDIndication(freelyprogrammable) 8(4) 8(4) 23/18(forproductswith

textdisplay) 17(12) 12(8)

FunctionKeys/HotKeys No 4 6(forproductswithtextdisplay) 4 10functions/2hotkeys

(availableonsomemodels)SettingsGroups 1/2 2 4 4 4(2)FaultRecords 5/25* 5 8 8 5EventRecords 75/250* 75 200 100 250-512

DisturbanceRecords 5(15smax) 8(24smax) 8(16.4smax) 8(16.4smax) 75smax.

ProgrammablelogicFlexiblelogic(availableonsomemodels)

Simple‘AND’logic Fullyprogrammable Fullyprogrammable Fullyprogrammable

IRIGB No No Option Option Option

LCDDisplay Alphanumeric Alphanumeric Alphanumeric/Graphical(somemodelsonly) Alphanumeric Alphanumeric

FrontPort(RS232) Yes(mostmodels) Yes Yes Yes Yes

RearPort Yes Yes Yes,2ndrearportoption Yes,2ndrearportoption Yes,2ndrearportoption

CourierEIA(RS)485(availableonsomemodels)

No EIA(RS)485orfiber EIA(RS)485orfiber K-Bus/EIA(RS)485orfiber(somemodelsonly)

Modbus EIA(RS)485 EIA(RS)485/Glassfiber EIA(RS)485orfiber EIA(RS)485orfiber EIA(RS)485orfiber(some

modelsonly)

IEC60870-5-103 EIA(RS)485 EIA(RS)485/Glassfiber EIA(RS)485orfiber EIA(RS)485orfiber EIA(RS)485orfiber(some

modelsonly)IEC60870-5-101 No No EIA(RS)485orfiber EIA(RS)485orfiber No

DNP3.0

EIA(RS)485(availableonsomemodelsonly)

No EIA(RS)485orfiber EIA(RS)485orfiber EIA(RS)485orfiber(somemodelsonly)

IEC61850 No No Availableonsomemodels No AvailableonsomemodelsOneBoxBayControlwithMimic No No Yes(availableonsome

models) No No

Terminals Ring Pin PinorRingType Pin Ring*AvailableonMiCOMphase2forP120,P122,P123,P125,P126,andP127

Page 8: MiCOM Protection

08MiCOM Px20, Px30, Px40Protection Relays

1 4 4 4 4 4 4 1 4 4 4 4 2 4 5 5 5

- - - - - - - 1 1 3 3 4/5 1 4/5 3 3 3/4

5

425

3/4

2 2 3 7 5 - 5 4 7 7 2 40 16 40 8 16 32

5 5 7 8 9 2 7 7 9 9 8 32 24 32 7 15 30

- - - - - 1 1 - - - - - - - - -

- - - - - X X - - - -

-

- - - - - -

16

15

-

-

32

32

-

-

- - -

- - -

- - -

- - -

- - -

- - -

X - -

- X X

- X X

- - -

- - -

- - -

- - - - - -

- - - - - -

X - - - - -

- - - - - -

- - - - - -

- - - - - -

- - - - X -

X X X X - X

X X X X X X

- - - - - -

- - - - X X

- - - - - - -

- - 10 1 10

- - 1/2 1/2 1/2

- X X - X

- - X - X

- - - - X

- - X - X

- - - X -

X X X - X

X X X X X

X X X X X

X X X X X

- - - -

- - -

- - -

X X X

- - -

- - -

X X X

- - -

X X X

X X X

X X X

X X X

X X X

-

-

-

X

-

-

-

-

-

-

-

-

-

-

-

X

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

- - - - - - - - - - X

- - - - - - X X X X X

- - -

-

- - - - - - -

-X X X - - X X X -

- - - - - - - - - -

- X X X - X - X X

X

X X

- X X X X X - X X X X

- X X X - - X X X X

- - - - - - - - X X X

- - - - - - X X X X X

- - - - - - - - - X X

- - - - - - - - XX X

- - - - - - - - - X X

- - - - - - - - - X X

- - - - - - - - - - -

X X X X X X X X X X X

- - - - - - - - XX X

- X X X - X - X X X X

- - - - - - - - - X X

- - - - - - - - - X X

- - - X - X - X X X X

- - - - - - - - - - X

- X X X - X - X X - -

- X X X

X X

- X - X X

X

X X

- - - - - - X X

- - - - - - X X X X

- X X X - X - X X -

- X X X - X - X X - X

- - - - - - - - - XX

- - - - - - - - - X X

- - - - - - - - - X X

- X - - -

- X X X X

X XXX X X

- - X X X

- - X X X

- X X X X

X X X X X

- X X X X

X X X X X

- X X X X

-

-

-

XX X X

X X X X X

- X X X X

- X - - -

- X - - -

X X X X X

- X - - -

X X X X X

- X - - -

- X - - -

- X - X X

- X - - X

- - X X X

- X X X X

- X - - -

X - X X X X

- XXX X X

- X X X X

X X - - -

- X - - -

- X - - -

-

-

X

-

-

X

-

X

X

X

X

X

-

X

X

X

X

X

X

X

X

X

X

X

X

-

-

X

-

X

-

-

X

-

X

X

-

X

X

X

-

-

-

-

-

X

-

-

X

-

X

X

X

X

X

-

X

X

X

X

X

X

X

X

X

X

X

X

-

-

X

-

X

-

-

X

X

X

-- - - - - - - - XX X - X X X X X X

-- - - - - - - - - X X - X X X X X X

X

-

X

X

X

-

-

-

CT Inputs

VT inputs

Opto Inputs ( max)1

Output Contacts (max)1

Output for Striker Triggering

Magnetic Flags

RTDs (max. option)

Analogue I/O (max. option)

Function Keys/Hotkeys

Bay Control & Monitoring

- with Mimic

Interlocking Logic

1 Phase or Earth overcurrent

3 Phase overcurrent

Ground fault

Phase directional

Ground Fault directional

Sensitive directional earthfault

Transient Ground Fault directionalWattmetric earthfault

Neutral admittance

Restricted earthfault

Voltage controlled overcurrent

Negative sequence overcurrent

Thermal overload

Undercurrent

Over/Under voltage

Residual over voltage

Negative sequence overvoltage

Over/Under frequency

Rate of change of frequency

Incomplete sequence relay

Master sequence device

Lock-out

Directional Power

Circuit breaker failure

Motor

Startup Monitoring

Autoreclose

Check synchronising

Broken conductor

Cold load pick-up

Inrush blocking

Switch on to fault

Circuit breaker monitoring

Trip Circuit Supervision

Limit value monitoring

Protective Signalling

InterMicom

Protection

Device P120 P121 P122 P122C P123P124Self

Power

P124Dual

PowerP125 P126 P127 P130C P132

P138Rail

P139 P141 P142 P143 P144 P145

50/51P/N

50/51P

50/51N

67P

67N

67N

67N

67W

YN

64

51V

46

49

37

27/59

59N

47

81O/U

87R

48

34

86

32

50BF

49LR

66

79

25

46BC

Voltage transformer supervision VTS

Current transformer supervision CTS

SOTF

TCS

85

MiCOM Series DataOVERCURRENT AND FEEDER MANAGEMENT RELAYS

•Pleasenotethatsomerelaysmayhavealimitonmax.I/Owhenusedasacombination.•3V0measuredinputandallowsveeconnectedVTs.

Page 9: MiCOM Protection

09MiCOM Px20, Px30, Px40Protection Relays

Device P220 P225 P226C P241 P242 P243 P341 P342

CT Inputs

VT inputs

Opto Inputs (max)1

Output Contacts (max)1

RTDs/thermistors (option)

Analogue I/O (option)

Function Keys/Hotkeys

Interlocking Logic

Motor Protection

Short circuit 50/51

Motor Differential 87M

Locked Rotor 50S/51LR/51S

Reverse Power 32R

Reacceleration 27LV

Startup Monitoring/Excessive long start 66/48/51

Negative sequence overvoltage 47

Out of Step 55

Loss of load 37

Undercurrent 37P/37N

Unbalance/Lock-out 30/46/86

Speed switch inputs

Anti Backspin

14

100% Stator Earth Fault (Low Freq. Injection) 64S

Generator Protection

Generator Differential 87G

Interturn/split phase 50DT

Underimpedance 21

Pole Slipping 78

Directional Power 32L/O/R

Loss of Field 40

Restricted earthfault 64

100% Stator earth fault (3rd harmonic) 27TN

Overfluxing 24

Unintentional energisation at standstill 50/27

Voltage dependent O/C

Rotor Earth Fault

51V

64R

Ancillary Functions

Phase overcurrent 50/51P

Phase directional 67P

Ground fault 50N/51N

Ground Fault directional 67N

Negative sequence thermal 46T

Turbine abnormal frequency 81AB

Negative sequence overvoltage 47

Sensitive directional earthfault 67N

Wattmetric earthfault 64N/32N

Negative sequence overcurrent 460C

Thermal overload 38/49

Under/Over voltage 27/59

Residual over voltage 59N

Under frequency 81U

Over frequency 81O

Voltage vector shift dVq

Rate of change of frequency 81R

Circuit breaker failure 50BF

Circuit breaker monitoring

Trip Circuit Supervision TCS

P343 P344 P345

Protection

X

X

X

X

X

X

X

X

X

X

X

X

X

X

-

X

X

X

X

X

X

X

X

-

-

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

-

X

X

X

X

X

X

X

X

-

-

X

X

X

8

4

32

32

10/0

4/4

X

X

8

5

32

32

10/0

4/4

X

X

4 4 4 4 4 7 4 5

- 1 1 3 3 3 4 4

5 6 7 8 16 16 16 24

6 6 8 7 16 16 15 24

6/0 or 4/2 10/3 - 10/0 10/0 10/0 - 10/0

0/1 0/2 - 4/4 4/4 4/4 4/4 4/4

- - X X XXX X

- - - X X X X X

X

-

X

-

X

X

-

-

X

X

X

X

-

-

-

-

-

-

-

-

-

-

-

X

-

X

-

-

-

-

-

-

-

X

-

-

-

-

-

-

-

X

X X X X X

- - - - X - -

X X X X X - -

- - X X X

X X X

- -

X X - -

X X X X X - -

- - X X X - -

- - X X X - -

X X X X X - -

X X X X X - -

X X X X X - -

- -

- -

- -

- -

- -

- -

- -

- -

- -

- -

X X X X X

X X X X X

- - - - - - -

- - - - - - -

- - - - - - X

- - - - - - -

- - - - - X X

- - - XX XX

- - - - - X X

- - - - - - -

- - - - - - X

- - - - - - X

- - - - - - X

X X X X X X X

X- - - - - X

X X X X X X X

- - - - - X

- - - - - - X X X

- - - - - - X X X

- - - - - XX X X

X

X

X

X

X

X

X

X

X

X

X

X

X XX X

X

X

X

-

X

X

X

X

X

X

X

X

-

-

X

X

X

9

6

32

32

10/0

4/4

X

X

-

-

-

-

-

-

-

-

-

-

X

X

X

-

- - X X X - X

- - X X X X X

X X X X X - X

X X X X X X X

X X X X X X X

- - X X X X X

- - X X X X X

- - - - - X X

- - - - - X -

- - - - - X -

X X X X X X X

X X X X X X X

X X X X X X X X

MOTOR AND GENERATOR MANAGEMENT RELAYS

•Pleasenotethatsomerelaysmayhavealimitonmax.I/Owhenusedasacombination.

Page 10: MiCOM Protection

MiCOM Px20, Px30, Px40Protection Relays 10

Broken Conductor 46BC

Stub Bus Protection 50ST

Voltage/Current transformer supervision VTS/CTS

Capacitive voltage transformer supervision CVTS

P444 P445 P847Device P430C P432 P433 P435 P436Rail

P437 P438Rail

P439 P441 P442 P443

CT Inputs

VT inputs

Opto Inputs(max)1

Output Contacts(max)1

RTDs (option)

Analogue I/O (option)

Function Key/Hotkeys

Bay Control & Monitoring with Mimic

Interlocking Logic

Distance Protection

Distance 21/21N

3 pole Autoreclose 79

1/3 pole

Power Swing Blocking 78

Out of step tripping 68

Check synchronising 25

Directional Power 32

Switch on-to fault 50/27

Mutual Compensation

Rail Catenary Protection HZ

PMU

Defrost Protection

Train startups

Phasor Measurement

Phase overcurrent 50/51P

Phase directional 67P

Ground fault 50/51N

Ground Fault directional 67N

Transient Ground Fault directional 67N

Neutral admittance YN

Delta directional comparison

Wattmetric earthfault 67W

Negative sequence overcurrent 46

Directional negative sequence 46/67

Thermal overload 49

Under/Over voltage 27/59

Residual over voltage 59N

Over/Under frequency 81U

Rate of change of frequency 81R

Circuit breaker failure 50BF

Channel Aided Scheme Logic 85

Trip Circuit Supervision TCS

InterMicom

Protection

-

X

X

-

4

3

2

8

-

30

-

X X X X

-

X

X

X

-

X

-

X

X

-

-

-

-

X

X

X

X

- -

-

X

X

X

X

X

X

X

X

X

X

X

-

X

X

-

4/5

4/5

52

38

1

1/2

-

X

X

X

-

X

X

XX

X

X

X

X

-

-

-

X

X

X

X

-

-

-

X

X

X

X

X

X

X

X

X

X

-

X

X

X

-

4

20

1

1/2

-

-

X

X

-

X

X

X

X

-

-

-

-

X

X

X

X

X

-

X

X

X

X

X

X

X

X

X

X

X

X

X

X

-

4

4/54/5

32

46

1

1/2

-

-

X

-

X

X

X

XX

X

X

-

-

-

-

X

X

X

X

X

-

X

X

X

X

X

X

X

X

X

X

X

- X -

X X -

X X X

- - -

2 4/5 3

1 4/5 2

28 32 28

46 46 46

1 1 1

1/2 1/2 1/2

- -

- - -

- - -

X X X

- - -

- X -

- X -

- X -

- X -

- -

X X X

- X -

16 2/3 - 25/50/60

- - X

X - X

X X X

- X X

- X -

- X -

- - -

- - -

- - -

- - -

- X -

- X -

X X X

X X X

- X -

- X -

- X -

X X X

- X -

X X X

XX -

X X X X

X X X X

X X X X

- X X - -

X

X

X

X

4

4

24

46

-

-

X

-

X

-

X

X

-

X

-

X

X

-

-

-

X

X

X

X

-

-

-

X

X

X

-

-

-

-

X

X

X

X

4

4

24

32 32

-

-

X

-

-

-

X

X

-

X

-

X

-

-

-

-

X

X

X

X

-

-

-

-

X

X

X

X

X

-

-

X

X

X

X

X

X

X

-

12

12

32

X

-

X

-

-

-

-

-

-

-

-

-

-

-

-

-

-

X

X

X

X

X

-

-

-

-

X

X

X

X

X

X

X

X

X

X

X

-

X

-

4 4 4 4

4/5 4 4 4

40 8 16 24

26 14 21 32

1 - - -

1/2 - - -

- X X X

X - - -

- -- - -X

X X X X

X X - -

- - X X

X X X

- - -

X X X X

X

X

X

X - - -

X X X X

- X X X

- - - -

- - - -

- - - -

- - - - -- - --- - - -

X X X X

X X X X

X X X X

X X X X

X - - -

XX X X

- - - X

- -

- -

-

XX X X - -

X X X X

X X X X

X X X X

X X X X

X - - X

X - - -

X - - -

X X X X

X X X X

X X X X

X - X X

di/dt,dv/dt,dΦ/dt

ΔI/ΔV

DISTANCE RELAYS AND PHASOR MEASUREMENT UNIT

•Pleasenotethatsomerelaysmayhavealimitonmax.I/Owhenusedasacombination.

Page 11: MiCOM Protection

MiCOM Px20, Px30, Px40Protection Relays 11

LINE DIFFERENTIAL, TRANSFORMER AND BUSBAR PROTECTION RELAYS

•Pleasenotethatsomerelaysmayhavealimitonmax.I/Owhenusedasacombination.

4 4 5 9 5 9 4 6 6 8 12 15 4 4 4

- - - 4 3 4 3 - - - 1 1 1 - - -

5 8 16 16 16 24 24

8 7 14 14 14 32 32

- - - - - - -

- - - - - - -

- X X X X X X

- X X X X X X

8 2 4 34 40 34 8

8 8 14 22 30 22 8

- - - 1/2 1/2 1/2 -

- - - 1 1 1 -

X X - - - - -

X X - - - - -

16 24

8 21

- -

- -

- -

- -

87P X

X

-

X

X

X

-

X

X

X

-

X

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

X X X X X X X X X X X X X - X X

- - X X X X - - - - - - - - -

X X X X X X X

- - X X X X -

- - X X X XX X X X

-

- - X X X X -

- - X X X X -

- X X X X -

- X - X

X X X

X X X

- - -

X X X X X - - - - - - - -

- - - - - - - - - - - - - -

X X X X X - - - - - - - - -

X X X X X - - - - - - - -

- - - - - - - - - - - - -

- - - - - - - - - - - -

- X XX X - - - - - - - - -

X X - - - - - - - - - - -

X X - - - - - - - - - - -

X

X

X

X

X- - - - - - - - - - -

X - X - - - - - - - - -

- - - - -

X -

-

X

X -

- -

- - -

-

X X

- - -

X X X X X X - - - -

- - - - - - X - - - - - - - -

X - - - - - - - -

- X X X X X - - -

- 2 2 2 3 4 - - -

- - 2 3 3 - - -

- X X X X X - - -

- - - X X X - - -

- X X X X X - - -

- - - X X X

-

-

- - - - - -

- - - - - -

- - - - - -

- - - - - -

- - - - - -

- - - - - -

- - - - - -

- - - - - - - -

- - - - - - - - - - - - X - -

- - - - - - - - - - - - - X X

- - - - - - - - - - - X - -

- - - - - - - - - - - - X - -

- - - - - - - - - - - - X - -

- - - - - - - - - - - - X X X

- - - - - - - - - - - - - X X

- - - - - - - - - - - X X X

-

-

X X X X X X -

- - - - - - - - -

-X X X X X X X

- - - - - - - -

- - - - - - - -

- - - - - -

- - - - - -

- - - - - - - - - -

X - - X X X X X X -

X X X X

X

X X X X X X -

X - - - - - - - - - - - - -

- - - - X X X -

- -

X X

-

- - -

- - - -

- -

- -

- -

- -

- -

X

- - - - -

X X X X X X X X - -

- - 3 pole3 pole 1/3 pole

1/3 pole

- - - - -

- - - - - - X

X X

4

3

2

8

-

-

X

X

-

X

X

X

-

X

-

X

-

X

X

X

-

X

X

-

-

-

X

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

X

X

-

-

X

X

- X X X X X

X X X X

X X X X

-

- - - X X X

- - - - - -

X X - - -

X X X X X

CT Inputs

VT inputs

Opto Inputs(max) 1

Output Contacts(max) 1

Analogue I/O (opti

RTDs (option)

Function Keys/Hotkeys

Interlocking Logic

Protection

Line Differential

2 terminal

2/3 terminal

FO signalling

Metallic signalling

Transient Bias (CT saturation)

SDH/Sonet ne

In Zone transformer

2 harmonic restraint

Vector Compensation

2 breaker configuration

Direct/Permissive Intertripping

Phase Comparison

PLC signalling

Transformer Differential

windings

Restricted earth fault

overfluxing/5 harmonic

overexcitation

2 harmonic restraint

Busbar Protection

Central unit up to 28 feeders

Peripheral units 8 zones

regated differential 8 zones

Sensitive earth fault differential 6 zones

Check Zone 8 zones

CT supervision

CT Saturation Detection

Fibre optic signalling

Ancillary Functions

Phase overcurrent

se directional

Ground fault

Ground Fault directional

Sensitive directional earthfault

Wattmetric earth

Distance Protection

Power Swing Blocking

Check Sync

Negative sequence overcurrent

Thermal overload

Loss of load/Undercurrent

Under/Over frequency

Circuit breaker failure

Autoreclose

Over/Under voltage

Trip Circuit Supervision

CT supervision

Device P521 P541P530C P542 P543 P544 P545 P546 P547 P630C P631 P632 P633 P634 P741 P742 P743

4

on)

tworks

-nd

th

nd

-

-

Phase seg

Pha

fault

81U/O

50BF

79

27/59

TCS

87PC

87P

87G/64

24

87BB

87P

87N

87CZ

CTS

50/51P

67P

50/51N

67N

CTS

67N

64W

21

78

25

46

49

37

Page 12: MiCOM Protection

EnergyAutomation-DS-PROTRange-1827-EN

©2010SchneiderElectric-Allrightsreserved

Asstandards,specificationsanddesignschangefromtimetotime,pleaseaskforconfirmationoftheinformationgiveninthispublication.

Publishing:SchneiderElectricDesign:SchneiderElectricPrinting:

This document has been printed on ecological paper

10-2010

Schneider Electric35,rueJosephMonierCS3032392506Rueil-MalmaisonCedex,FranceTel:+33(0)141297000

RCSNanterre954503439Capitalsocial896313776€www.schneider-electric.com

MiCOM Px20, Px30, Px40Protection Relays 12

4 - 6 - - - - -

- 4 3 4 4 4 3 3

5 48 16 2 5 5 16 32

9 32 24 4 8 8 15 30

X - - - - - - -

X - - - - - - -

X - - - - - - -

X - - - - - - -

- X - - - - - -

- X - - - - - -

- X - - - - - -

- X - - - - - -

- - X - - - - -

- - X - - - - -

- - X - - - - -

- - X - - - - -

- - - X X X X X

- - - X X X X X

- - - X X X - -

- - - - X X - -

- - - - X X X X

- - - - - X X X

- - - - - X X

- - - - - - X X

- - - - - - X X

- - - - - - X X

X X X - X X X X

yes by

logic

Device P821 P842 P846 P921 P922 P923 P941 P943

CT Inputs

VT inputs

Opto Inputs(max)

Output Contacts(max)

Protection

Breaker Failure Protection 50BF

2 Stage

Pole Discrepancy

Dead Zone Function

Autoreclose 79

Mesh Corner/Single Switch

Check Sync 25

Ferroresonance Suppression

Open Line Detector DLO

High Speed Breaker Fail 50BF

Fast Hybrid Output contacts

3 pole tripping

Voltage and Frequency Protection

Undervoltage 27

Overvoltage 59

Residual Overvoltage 59N

Phase Sequence Voltage 47/27D

Under/Over frequency 81U/O

Rate of change of Frequency (df/dt+t)

81R

Frequency supervised Rate of change of Frequency (f+df/dt)

81RF

Frequency supervised average Rate of change of Frequency (f+Δf/Δt)

81RAV

Generator Abnormal Frequency 81AB

Load Restoration logic

Trip Circuit Supervision TCS

VOLTAGE, FREQUENCY AND ANCILLARY PROTECTION RELAYS