MICE magnet positional tolerances when assembling the cooling channel 1 Tim Hayler STFC

Upload: winter

Post on 19-Jan-2016

21 views

Category:

Documents


0 download

DESCRIPTION

MICE magnet positional tolerances when assembling the cooling channel. Tim Hayler STFC. MICE NOTES. 229 Alignment Errors on Emittance Measurements for MICE David Forrest, F.J.P. Soler deals with spectrometer alignment (step VI, flip, 200 MeV/c ) - gives tolerance of order 10 mm, 3 mrad - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: MICE magnet positional tolerances when assembling the cooling channel

MICE magnet positional tolerances when assembling the cooling channel

1

Tim HaylerSTFC

Page 2: MICE magnet positional tolerances when assembling the cooling channel

MICE NOTES

• 229 Alignment Errors on Emittance Measurements for MICEDavid Forrest, F.J.P. Soler deals with spectrometer alignment (step VI, flip, 200 MeV/c) - gives tolerance of order 10 mm, 3 mrad

• 202 Beamline to MICE Alignment and Matching ToleranceC. Rogers deals with beam alignment to cooling channel (step VI flip 200 MeV/c - gives tolerance of order 2 mm, 10 mrad

• 64 Initial study of MICE Magnet Alignment RequirementsU. Braver, J.H. Cobbdeals with focus coil alignment (step VI, flip, 200 MeV/c) - gives tolerance of order 2 mm, 2 mrad

Thanks to Chris Rogers and John Cobb for the information

2

Page 3: MICE magnet positional tolerances when assembling the cooling channel

ConclusionDifferent studies, all agreeing with a general tolerance of 1 mm, 1 mrad? Does this tolerance simply cover our backs?

Can we relax these tolerances for the cooling channel?seems the order of importance is: Tilt angle very importantTransverse not so importantLongitudinal less stringent again

Can we split up the tolerance into these three components?

3

Page 4: MICE magnet positional tolerances when assembling the cooling channel

MICE Hall CSYS

x

y

z

4

Page 5: MICE magnet positional tolerances when assembling the cooling channel

The position of the magnetic axis with respect to a tolerance zone about the nominal axis

Magnetic axis of the module

Cylindrical tolerance zone of 1mm diameter1mm

Y

ZX

Reference the MICE hall coordinate system on slide four

Beam Nominal axis

Projection 5

Page 6: MICE magnet positional tolerances when assembling the cooling channel

The positional tolerance of the magnet centre longitudinally with respect to the nominal centre

X

Y

Z

y

xz

Reference the MICE hall coordinate system on slide four

Nominal centre

Magnet centre

Upstream Downstream

6

±0.5mm

Page 7: MICE magnet positional tolerances when assembling the cooling channel

Table of positional tolerances

Component Positional tolerance zone of the magnetic axis with respect to the nominal axis

The positional tolerance of the magnet centre longitudinally with respect to the nominal centre

Comments

Virostek plates 5mm ±3mm

Spectrometer Solenoid

1mm ±0.5mm

AFC 1mm ±0.5mm

RFCC 1mm ±0.5mm

7

Potential to relax and split the tolerance zone into tilt and traverse tolerances?

Page 8: MICE magnet positional tolerances when assembling the cooling channel

Spectrometer support frame

8

Page 9: MICE magnet positional tolerances when assembling the cooling channel

Spectrometer feet locations

The Spectrometer has four feet, in each foot there is a boss that houses a locating pin. The locating pin is threaded into the boss and can be adjusted in height about its nominal position. A hemispherical dome on the end of the pin locates in a similar hemispherical cup on the support frames.

1250

2160

Spectrometer foot

Page 10: MICE magnet positional tolerances when assembling the cooling channel

Height adjustment

10

Page 11: MICE magnet positional tolerances when assembling the cooling channel

Longitudinal adjustment

11

Page 12: MICE magnet positional tolerances when assembling the cooling channel

Traverse adjustment

12