marpol, revised annex iv prevention of pollution by sewage entry into force 27 september 2003
TRANSCRIPT
![Page 1: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/1.jpg)
MARPOL, Revised Annex IVPrevention of Pollution by sewage
Entry into force 27 september 2003
![Page 2: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/2.jpg)
2MARPOL, revised Annex IV – Prevention of oil pollution by sewage
Why a revised Annex IV
► ANNEXES I (OIL POLLUTION) AND II (NLS) MANDATORY
► ANNEXES III (HARMFULL PACKAGED GOODS), IV (SEWAGE) AND V (GARBAGE) OPTIONAL
► ANNEX IV AS INITIALLY DRAFTED CONSIDERED AS BEING TOO SEVERE
![Page 3: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/3.jpg)
3MARPOL, revised Annex IV – Prevention of oil pollution by sewage
What is sewage ?
► DRAINAGE TOILETS AND URINALS,
► DRAINAGE FROM MEDICAL PREMISES,
► DRAINAGE FROM SPACES CONTAINING LIVING ANIMALS,
► OTHER WASTE WATERS WHEN MIXED WITH THE DRAINAGES DEFINED ABOVE.
![Page 4: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/4.jpg)
4MARPOL, revised Annex IV – Prevention of oil pollution by sewage
Which ships are failling under the scope of the revised Annex IV ?
► NEW SHIPS :
400 GT AND ABOVE AND
LESS THAN 400 GT CARRYING MORE THAN 15 PERSONS, AS FROM 27 SEPTEMBER 2003.
► EXISTING SHIPS :
400 GT AND ABOVE AND
LESS THAN 400 GT CARRYING MORE THAN 15 PERSONS, AS FROM 27 SEPTEMBER 2008
![Page 5: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/5.jpg)
5MARPOL, revised Annex IV – Prevention of oil pollution by sewage
Sewage systems and standard discharge connections
► A SHIP SHALL BE EQUIPED WITH ONE OF THOSE SYSTEMS :
SEWAGE TREATMENT PLANT
SEWAGE COMMINUTING AND DISINFECTING SYSTEM
HOLDING TANK
► AND A STANDARD DISCHARGE CONNECTION
![Page 6: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/6.jpg)
6MARPOL, revised Annex IV – Prevention of oil pollution by sewage
Where may sewage be discharged ?
► EFFLUENT FROM SEWAGE TREATMENT PLANT :
EVERYWHERE
► COMMINUTED AND DISINFECTED SEWAGE :
NOT LESS THAN 3 MILES FROM NEAREST LAND
► UNTREATED SEWAGE :
NOT LESS THAN 12 MILES FROM NEAREST LAND, EN ROUTE, SUBJECT TO RATE OF DISCHARGE APPROVAL
![Page 7: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/7.jpg)
7MARPOL, revised Annex IV – Prevention of oil pollution by sewage
Certificate scheme
► APPROVAL OF DRAWINGS
► SURVEY REGIME :
INITIAL AND RENEWAL SURVEYS
► CERTIFICATE (ISPPC):
5 YEARS VALIDITY, IN LINE WITH CLASSIFICATION AND OTHER STATUTORY CERTIFICATES (HSC)
![Page 8: MARPOL, Revised Annex IV Prevention of Pollution by sewage Entry into force 27 september 2003](https://reader036.vdocuments.us/reader036/viewer/2022082323/56649d985503460f94a82c85/html5/thumbnails/8.jpg)
8MARPOL, revised Annex IV – Prevention of oil pollution by sewage
ASMS Items and Certificate editor
► SURVEY CODES : SEWS, SEWO
► ITEMS COTE : SEW
► INTERNATIONAL SEWAGE POLLUTION PREVENTION CERTIFICATE (1973)
► INTERNATIONAL SEWAGE POLLUTION PREVENTION CERTIFICATE (FULL AND SHORT TERM)
► DOCUMENT OF COMPLIANCE