maico product line: lançamento€¦ · frequency range (khz) 2-5 dp 1.5-12 dp screener: 1.5-4 te...

7
Sistema de Emissões Otoacústicas Maico Diagnostics vendas: [email protected] - Tel. 11 3363 8888 www.maico.com.br 6,55 cm Tamanho Real 14,68 cm Disponível em duas versões: Screener Plus Com protocolos de testes de 4 frequências DPOAE Diagnostic Plus com protocolos de testes de 4, 6 e 12 frequências DPOAE Lançamento Screener e Diagnóstico

Upload: others

Post on 20-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

Sistema de EmissõesOtoacústicas

Maico Diagnostics

vendas: [email protected] - Tel. 11 3363 8888www.maico.com.br

6,55 cm Tamanho Real

14,6

8 cm

MAICO Product Line:• Screening Audiometers

• Diagnostic Audiometers

• Middle Ear Analyzers

• OAE Test Systems

• PC Compatible Products

This brochure contains only a small segment of the comprehensiveproduct portfolio of MAICO. To find out more about other solutions,please contact us at:

Telephone: 888-941-4201

MAICO Diagnostics7625 Golden Triangle DriveEden Prairie, MN 55344Tel: 888-941-4201Fax: 952-903-4100Web: www.maico-diagnostics.com

Innovation,Continuity,

Reliability,

MAICO DIAGNOSTICS

capture and keep your young patient's attention.

®

Innovation, Continuity,

Reliability,

Pilot Pure Tone Audiometer

MA 25Screening Audiometer

MAICO Product Line:• Screening Audiometers

• Diagnostic Audiometers

• Middle Ear Analyzers

• OAE Test Systems

• PC Compatible Products

This brochure contains only a small segment of the comprehensiveproduct portfolio of MAICO. To find out more about other solutions,please contact us at:

Telephone: 888-941-4201

MAICO Diagnostics7625 Golden Triangle DriveEden Prairie, MN 55344Tel: 888-941-4201Fax: 952-903-4100Web: www.maico-diagnostics.com

Innovation,Continuity,

Reliability,

Race CarAudio/Tymp

This brochure contains only a small segment ofthe comprehensive product portfolio of MAICO. To find out more about other solutions,please contact us at:

Telephone: 888-941-4201

Disponível em duas versões:Screener PlusCom protocolos de testes de 4 frequências DPOAE

Diagnostic Plus com protocolos de testes de 4, 6 e 12 frequências DPOAE

Lançamento

Screener e Diagnóstico

Page 2: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

Ero•Scan - Sistema de Emissões Otoacústicas Parts & AccessoriesIdeal para...• Audiologistas• Otorinolaringologistas• Pediatras•Teste da orelhinha

• Triagem escolar• Maternidades

Emissões Otoacústicas (OAE)Emissões Otoacústicas são sons produzidos pela cóclea (células ciliadas externas) e podem ser medidas no meato acústico externo. O som, ao passar pelo meato acústico externo, alcança a cóclea e a vibração estimula as milhares de células ciliadas. Esta produz um efeito que pode ser detectado e medido: Emissões otoacústicas.As OAE só ocorrem em uma cóclea normal com sensitividade auditiva normal. Se existir dano nas células ciliadas externas, produzindo perda auditiva. as OAE não estarão presentes. Geralmente, as OAE estarão presentes se a audição estiver em 30 dB ou melhor.Resultado de PASSA significa que as emissões otoacústicas foram detectadas. Caso haja dano das células ciliadas externas produzindo uma perda auditiva leve, as emissões otoacústicas poderão não estar presentes. O resultado de FALHA (REFER), pode significar que o paciente corre o risco de possiveis dificuldades de comunicação e pode beneficiar-se com uma avaliação diagnóstica mais aprofundada. Este procedimento é benéfico para avaliar crianças em um programa de triagem auditiva ou aquelas que não podem ser testadas pelos métodos convencionais. Por exemplo, a audiometria de tom puro requer uma resposta da criança o que pode gerar uma expectativa irreal e gasto de tempo.

Ideal for...

OtorrinolaringologistasO teste de Emissões Otoacústicas é uma ferramenta ideal para triagem auditiva porque pode identificar rapidamente possíveis perdas auditivas e o profissional pode encaminhar o paciente para testes mais abrangentes.

PediatrasA perda auditiva nem sempre é identificada na triagem auditiva na maternidade. Os pediatras são os primeiros profissionais que os pais procuram quanto à audição da criança.Tanto os pediatras que atendem em hospitais como os que atendem em clínicas particulares podem avaliar os bebês e crianças pequenas quanto à perda auditiva e alterações de orelha média, incorporando as OAE nos seus testes rotineiros, trazendo grandes benefícios.

Triagem neonatal e escolarO MAICO ERO•SCAN é uma ferramenta efetiva para triagem auditiva neonatal, teste da orelhinha e triagem escolar, permitindo documentar testes auditivos em muitas crianças rapidamente. Como não precisa de respostas comportamentais dos pacientes, é muito fácil testar também crianças com necessidades especiais.

(Additional software and computer NOT required to change protocols)

Product Feature EroScan Screener EroScan Diagnostic TE (Upgrade) DPOAE Y Y Y

Diagnostic (CPT) 92558 92558, 92587 See DPOAEand 92588 Portable Y Y Y

External Probe Y Y YMaximum Number of Test

4 DP 12 DP 6 TEFrequencies or Bands Reported

Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE

High Frequencies DPs to 12 kHz N Y NADefault Pass/Refer Y Y YAuto Start Y Y Y

Number of Test Protocols 2 DP 5 DP Screener: 2 TE Diagnostic: 3 TE Battery Operated (rechargable) Y Y YNumber of tests per charge 1000 1000 1000(minimum)Memory (# tests)/Maximum 250 250 250Tests All Ages Y Y YTests Patients with PE Tubes Y Y YCustomizable Parameters:

• Customizable Test Protocols N Y Screener: N Diagnostic: Y

• Customizable Pass Criteria N Y Screener: N Diagnostic: Y

● • Frequency Range N Y Screener: N Diagnostic: Y

● • Averaging Time N Y Screener: N Diagnostic: Y● • # Freq. to Pass N Y YDatabase Software Included Y Y Y

● • Load pt. names to device Y Y Y● • Print Full Page (Color) Y Y Y● • Field for Interpretation Y Y Y● • OZ Compatible Y Y Y● • HI*TRACK Compatible Y Y YPrints Numeric Data Y Y YPrints Graphic Data Y Y YDate/Time on Print-Out Y Y YCarrying Case (Included) Y Y NAThermal Printer Option Option NAAll test protocols changes can bemade through OAE unit alone Not Customizable Y Screener: N

Diagnostic:Y

www.maico-diagnostics.comScreener e Diagnóstico

Printer #8105620

EroScan Charger #8029254

Micro USB Cable #8101864

Probe Tubes #8104159

Thermal Printer Paper #8029305

Eartip Kit #8029306

Probe #8029264

Carry Case #8104708

Avaliação Visual Avaliação da

orelha média

Meato acústico externo

Cóclea

Membrana Timpânica

AvaliaçãoTimpanométrica Avaliação de Emissões

Page 3: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

SpecificationsMeasurement Type: Distortion Product Otoacoustic Emissions (DPOAE)

Transient Evoked Otoacoustic Emissions (TEOAE)

Frequency Range: Screener version:DPOAE: 2.0 kHz to 5.0 kHz TEOAE: 1.5 kHz to 4.0 kHz

Diagnostic version: DPOAE: 1.5 kHz to 12.0 kHz TEOAE: 0.7 kHz to 4.0 kHz

Stimulus DPOAE: 40 dB SPL to 70 dB SPLIntensity Range: TEOAE: 83 dB SPL peak equivalent (±3 dB)

Microphone System -20 dB SPL @ 2 kHz (1 Hz bandwidth) / Noise: -13 dB SPL @ 1 kHz (1 Hz bandwidth)

Dimensions and Length: 1.0 meter (40 in.)Weight Probe: Weight: 28 g (1.00 oz.)

Dimensions and Dimensions: W X D X H 2.58 X 1.23 X 5.78 in.Weight Unit: Weight: 180 g (6.4oz.)

Power Supply: Lithium-Ion rechargeable

Battery Life: 1000 tests per charge, minimum 20 hours on-time

User Interface: OLED Display to provide user information and progress of measurement4-button keypad to control instrument functions

Connectors / Integrated USB communication capability for batteryCommunications: charging and communication with PC-based database

programs or an optional printerHDMI Connector for connection to the Micro-ProbeIntegrated Bluetooth Class 2 + EDR with SPP Protocol for communication with optional printer

Protocols/Specifications

DPOAE ProtocolsName # of Freq. F2 Freq. [kHz] L1/L2 Averaging Time Pass SNR # Passing Freq. for Test Pass

ScreeningDP 4s 4 2, 3, 4, 5 65/55 4 sec 6 dB 3

DP 2s 4 2, 3, 4, 5 65/55 2 sec 6 dB 3

DP 2.0-5.0 4 2, 3, 4, 5 65/55** 4 sec** 6 dB** 3**

DP 1.5-6.0 6 1.5, 2, 3, 4, 5, 6 65/55** 4 sec** 6 dB** 0**

DP 1.6-8.0 12 1.6, 2, 2.5, 3.2, 3.6, 65/55** 4 sec** 6 dB** 0**4, 4.5, 5, 5.6, 6.3, 7.1, 8

DP 1.5-12.0 12 1.5, 2, 3, 4, 5, 6, 7, 8, 9, 65/55** 4 sec** 6 dB** 0** 10, 11, 12

(Diagnostic version also includes DP 4s screening protocol)

TEOAE ProtocolsName # of Freq. Bands Freq. center bands [kHz] Averaging Time (max) Pass SNR # Passing Freq. for Test Pass

ScreeningTE 64s 6 1.5, 2, 2.5, 3, 3.5, 4 64 4 dB 3

TE 32s 6 1.5, 2, 2.5, 3, 3.5, 4 32 4 dB 3

DiagnosticTE1.5-4.0 6 1.5, 2, 2.5, 3, 3.5, 4 64 sec** 4 dB** 3**

TE0.7-4.0 6 0.7, 1, 1.4, 2, 2.8, 4 64 sec** 4 dB** 0**

(Diagnostic version also includes TE64s screening protocol)** Customizable fields: L1/L2 : DP: 40 to 70 dB SPLAverage time: : DP: 0.5, 1.0, 2.0 or 4.0 sec

: TE: 4, 8, 16, 32 or 64 secPass SNR : DP and TE: 3 dB to 10 dBPassing Freq. for Test Pass : DP and TE: 1 to 12

Diagnostic Uso das Emissões Otoacústicas• Acompanhar os bebês na triagem no berçários e nos

retornos.• Monitorar a função coclear em pacientes que estão

tomando medicamento altamente ototóxico.• Identificar a perda auditiva significativa educacionalmente

• Detectar a perda auditiva de início tardio• Diferenciar a possível patologia coclear

da retrococlear.• Identificar a perda auditiva não-patológica ou

suspeita de simulação.• Identificar a perda auditiva auto-imune ou súbita• Possibilitar triagem coclear objetiva em pacientes não

cooperantes e em pacientes cooperantes, nos quaistestes comportamentais não podem ser realizados.

• Detectar os primeiros sinais de exposição ao ruídoem pessoas que estão expostas a elevados níveisde ruído

Benefícios do Ero•Scan Resultados são mostrados como Passa ou FalhaSem necessidade de ajuda para interpretação. O equipamento é automático e oferece facilidade para ler e interpretar os resultados. O treinamento é rápido e extremamente intuitivo! O teste é completo e objetivo !Sem necessidade de resposta subjetiva do paciente. Resultados precisos !O algoritmo de ruído patenteado do ERO•SCAN permite testes confiáveis com até 70 dB de ruído de fundo, o que significa menor número de falsos positivos.

Screener and Diagnostic vendas: [email protected] - Tel. 11 3363 8888www.maico.com.br

Teste as duas orelhas em menos de 1 minuto. Testes duram menos de 30 segundos por orelha.

MemóriaO EroScan contem memória para armazenar até 250 testes.

PortabilidadeO EroScan é portátil e recarregável com um mínimo de 1000 testes entre as cargas. A sonda remota permite um fácil manuseio ao redor da cabeça do seu paciente afim de conseguir uma perfeita vedação.

Gerenciando dadosImpressão de relatórios e armazenamento de dados são extremamente fáceis com o uso do software gratuito na compra de seu equipamento.

Page 4: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

Testes de Triagem e Diagnóstico*dependendo da versão adquirida.

Triagem O ERO•SCAN screener proporciona uma medição e resultados rápidos das Emissões Otoacústicas por Produto de Distorção (DPOAE) ou das Emissões Otoacústicas Evocadas Transientes (TEOAE) em diversas frequências. Este equipamento é uma ferramenta de triagem ideal para profissionais envolvidos em um programa de triagem auditiva ou que precisam de uma rápida avaliação do sistema coclear devido aos resultados de PASSA ou FALHA. Este equipamento é usado para todas as idades, sendo uma solução ideal para recém-nascidos e crianças até a idade pré escolar.

• Protocolos padronizados no equipamento• 4 frequências de testes de DPOAE

DiagnósticoO equipamento ERO•SCAN de diagnóstico é uma ferramenta de teste eficaz para otologistas, fonoaudiólogos e otorrinolaringologistas que fornece informações objetivas sobre a audição e condição da orelha média com apenas um teste. Identificar a função das células ciliadas externas na cóclea, avaliar a função da orelha média e diferenciar entre a perda auditiva funcional orgânica e não-orgânica. OAE também são benéficas na avaliação de pacientes que não podem ser testados por métodos convencionais.

• Faixa de frequência de 1.5 a 12 kHz com até 12 frequências reportadas

• Protocolos de testes personalizáveis

The ERO•SCAN Database Software is a data management

tool that compliments the MAICO ERO•SCAN. It provides

the ability to transfer patient OAE test data from the device

to a PC for the purposes of viewing, archiving, managing

and printing OAE reports. Using the database also gives you

the means to create letter sized, detailed reports that can

be easily filed or faxed. You can also create a “paperless”

office by saving the test results as a PDF for electronic filing

or email.

Database Software

Maico Diagnostics7625 Golden Triangle Drive

Eden Prairie, MN 55344888.941.4201

Patient Name: 578264Date of Birth: 1/1/2014Sex: Male

Patient ID:SmithJohn

DPOAE Test Report

Right Ear: PASS2/26/2014 1:50:24 PM

Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3Protocol: DP 4sTest Date: Avg Time: 4

F2 L1 L2 DP NF SNR

2.0 65 55 -11 -17 63.0 65 57 -2 -20 18 P4.0 67 56 4 -20 24 P5.0 66 55 7 -20 27 P

DPOAE Test Report

Left Ear: PASS2/26/2014 1:51:17 PM

Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3Protocol: DP 4sTest Date: Avg Time: 4

F2 L1 L2 DP NF SNR

2.0 65 52 -14 -17 33.0 62 53 -2 -20 18 P4.0 63 53 -1 -20 19 P5.0 63 53 3 -20 23 P

Page 1 of 1

DPOAE Test Report

Right Ear: PASSTest Date: 2/26/2014 1:50:24 PM Protocol: DP 4s Avg Time: 4Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3

DPOAE Test Report

Left Ear: PASSTest Date: 2/26/2014 1:50:24 PM Protocol: DP 4s Avg Time: 4Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3

F2 L1 L2 DP NF SNR

2.0 65 55 -11 -17 63.0 65 57 -2 20 18 P4.0 67 56 4 -20 24 P5.0 66 55 7 -20 27 P

F2 L1 L2 DP NF SNR2.0 65 52 -14 -17 33.0 62 53 -2 -20 18 P4.0 63 53 -1 -20 19 P5.0 63 53 3 -20 23 P

www.maico-diagnostics.comScreener e Diagnóstico

Page 5: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

Screening and Diagnostic Testing

ReimbursementOtoacoustic emissions are reimbursable using the Current Procedural Terminology (CPT) codes. The most typical CPT code for OAE diagnostic.

92558:Evoked otoacoustics emissions, screening (qualitativemeasurement of distortion product or transient evoked otoacoustics emissions), automated analysis.

92587:Distortion product evoked otoacoustic emissions;limited evaluation (to confirm the presence of absence of hearing disorder, 3-6 freq.) or transient evoked otoacoustic emissions, with interpretation and report.

92588:Distortion product evoked otoacoustic emissions, comprehensive diagnostic evaluation (quantitative analysis of outer hair cell function by cochlear mapping, minimum of 12 freq.), with interpretation and report.

ScreeningERO•SCAN Screener test system provides a rapid measurement and documentation of Distortion Product Otoacoustic Emissions (DPOAEs) or TransientEvoked Otoacoustic Emissions (TEOAEs) at several frequencies. This device is an ideal screening tool for professionals involved in a hearing screening program or needing a quick assessment of the cochlear system due to the “Pass” or “Refer” outcomes provided. This device is used for all age groups but an ideal solution for pre-school and kindergarten children and even newborn infants.

• Qualified protocols built into the device

• 4 DPOAE test frequencies reported

• Integration to state tracking systems, Hi-Track or Oz

DiagnosticERO•SCAN Diagnostic test system is an effective testing tool for otologists, audiologists and otolaryngologists that provides objective information about hearing and middle ear status with only one test. Identify outer hair cell function in the cochlea, assess middle ear function and differentiate between organic and non-organic functional hearing loss. OAEs are also beneficial in assessing patients who cannot be tested by conventional methods.

• 1.5 to 12 kHz Frequency range with up to 12 test frequencies reported

• Customizable test protocols

• TEOAE available as an upgradeable option

O Software de banco de dados do ERO•SCAN é um programa de gerenciamento de dados dos seus pacientes que complementa o seu equipamento MAICO ERO•SCAN. Possibilita transferir os resultados dos testes dos pacientes para o computador, com os objetivos de visualizar os gráficos, arquivar, imprimir e gerenciar as emissões otoacústicas realizadas. Usando o software de banco de dados você pode criar relatórios detalhados os quais podem ser arquivados, impressos ou convertidos em PDF e enviar os resultados por email ou outros modos eletrônicos de compartilhamento.

Este software é gratuito na compra de seu equipamento!

Software de banco de dados

Clinica de Estudos da AudiçãoTriangle Drive Eden Prairie, MN 55344

888.941.4201

Patient Name: 578264Date of Birth: 1/1/2014Sex: Male

Patient ID:SmithJohn

DPOAE Test Report

Right Ear: PASS2/26/2014 1:50:24 PM

Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3Protocol: DP 4sTest Date: Avg Time: 4

F2 L1 L2 DP NF SNR

2.0 65 55 -11 -17 63.0 65 57 -2 -20 18 P4.0 67 56 4 -20 24 P5.0 66 55 7 -20 27 P

DPOAE Test Report

Left Ear: PASS2/26/2014 1:51:17 PM

Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3Protocol: DP 4sTest Date: Avg Time: 4

F2 L1 L2 DP NF SNR

2.0 65 52 -14 -17 33.0 62 53 -2 -20 18 P4.0 63 53 -1 -20 19 P5.0 63 53 3 -20 23 P

Page 1 of 1

DPOAE Test Report

Right Ear: PASSTest Date: 2/26/2014 1:50:24 PM Protocol: DP 4s Avg Time: 4Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3

DPOAE Test Report

Left Ear: PASSTest Date: 2/26/2014 1:50:24 PM Protocol: DP 4s Avg Time: 4Instrument: V100.05 ME0000115 MEdemo34 Frequencies: 4, minimum for a pass: 3

F2 L1 L2 DP NF SNR

2.0 65 55 -11 -17 63.0 65 57 -2 20 18 P4.0 67 56 4 -20 24 P5.0 66 55 7 -20 27 P

F2 L1 L2 DP NF SNR2.0 65 52 -14 -17 33.0 62 53 -2 -20 18 P4.0 63 53 -1 -20 19 P5.0 63 53 3 -20 23 P

Screener and Diagnosticvendas: [email protected] - Tel. 11 3363 8888

www.maico.com.br

Page 6: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

EspecificaçõesTipos de medidas: Produto de Distorção (DP)

Transiente (TE)

Faixa de frequência: Versão Screener: DPOAE: 2.0 kHz a 5.0 kHz TEOAE: 1.5 kHz a 4.0 kHz

Versão Diagnóstico: DPOAE: 1.5 kHz a 12.0 kHz TEOAE: 0.7 kHz a 4.0 kHz

EstimuloFaixa de Intensidade

DP: 40 dB NPS a 70 dB NPSTE: 83 dB NPS pico equivalente de ±3 dB

Sistema de ruído do microfone:

-20 dB NPS @ 2 kHz (1 Hz largura da banda) / -13 dB NPS @ 1 kHz (1 Hz largura da banda)

Dimensões e Peso da Sonda:

Comprimento: 1 metro 28 gramas

Dimensões e Peso da unidade :

6,55 Largura X 3,12 Altura x 14,68 comprimento (cm)180 Gramas

Fonte de energia Bateria recarregável de Lítio

Vida da Bateria 1000 testes por carga, mínimo de 20 horas ligado.

Interface do Usuário: Display de cristal líquido para fornecer ao usuario a informação e progresso dos testes. 4 botões para controlar as funções do equipamento.

Conectores / Comunicações:

Conectores / comunicação USB com capacidade de carga da bateria, Comunicações: comunicação com o computador e impressora (opcional)Cabo com conector HDMI para conexão com a sonda. Bluetooth integrado classe 2 + EDR com SPP Protocolo para comunicação com impressora opcional

Protocolos / Especificações

Protocolos DPOAE Nome # de Freq. F2 Freq. [kHz] L1/L2 Tempo médio Passa SNR # Freq. para passar no teste

ScreeningDP 4s 4 2, 3, 4, 5 65/55 4 segundos 6 dB 3

DP 2s 4 2, 3, 4, 5 65/55 6 dB 3

DP 2.0-5.0 4 2, 3, 4, 5 65/55** 4 seg** 6 dB** 3**

DP 1.5-6.0 6 1.5, 2, 3, 4, 5, 6 65/55** 4 seg** 6 dB** 0**

DP 1.6-8.0 12 1.6, 2, 2.5, 3.2, 3.6, 65/55** 4 seg** 6 dB** 0**4, 4.5, 5, 5.6, 6.3, 7.1, 8

DP 1.5-12.0 12 1.5, 2, 3, 4, 5, 6, 7, 8, 9, 65/55** 4 seg** 6 dB** 0** 10, 11, 12

(versão Diagnóstico também incluí protocolo screening 4 segundos).

Protocolos TEOAE Nome # de bandas de Freq bandas centrais de Freq [kHz] Tempo médio (máx) Passa SNR # Freq. para passar no teste

ScreeningTE 64s 6 1.5, 2, 2.5, 3, 3.5, 4 64 4 dB 3

TE 32s 6 1.5, 2, 2.5, 3, 3.5, 4 32 4 dB 3

DiagnósticoTE1.5-4.0 6 1.5, 2, 2.5, 3, 3.5, 4 64 segundos** 4 dB** 3**

TE0.7-4.0 6 0.7, 1, 1.4, 2, 2.8, 4 64 segundos** 4 dB** 0**

(versão Diagnóstico também incluí protocolo screening TE64s) ** Campos personalizáveis:

L1/L2 Tempo médio:

: DP: 40 a 70 dB NPS: DP: 0.5, 1.0, 2.0 ou 4.0 segundos

Passa SNR Freq. para passar no teste

: TE: 4, 8, 16, 32 or 64 segundos: DP e TE: 3 dB a 10 dB : DP de 1 a 12 e TE de 1 a 6

Diagnóstico

Utilizing OAEs• Follow-up infants from nursery screening and well-baby checks

• Monitor cochlear function in those who are taking medication that is potentially ototoxic

• Identify educationally significant hearing loss

• Detect late-onset hearing loss

• Differentiate possible cochlear versus retrocochlear pathology

• Identify suspected malingering or non-pathological hearing loss

• Identify autoimmune or sudden hearing loss

• Provide objective cochlear screening in both non-cooperative patients and cooperative patients

where behavioral testing cannot be performed

• Detect early signs of noise exposure in those who are exposed to high noise levels

Ero•Scan BenefitsResults are displayed as Pass or ReferNo need for interpretation. The equipment is automated and will provide easy to read and easy to interpret results. Training is quick and extremely intuitive!

Test is completely objectiveNo response from the patient is necessary.Easily test uncooperative or non-English speaking patients.

Accurate resultsThe patented ERO•SCAN noise algorithm allows for reliable testing inup to 70 dB of background noise, which means fewer false refer results.

Test both ears in less than a minuteTesting takes less than 30 seconds per ear.

MemoryThe ERO•SCAN contains memory to store 250 tests.

PortabilityThe ERO•SCAN hand-held unit is rechargeable with a minimum of1000 tests between charge and allows you to move from room to room. The remote probe makes it easy to maneuver around the head of your patient to attain a tight ear seal.

Managing dataPrinting reports and tracking data is easy with the database software.

State reportingThe database integrates data into HiTRACK or OZ.

www.maico-diagnostics.comScreener e Diagnóstico

2 segundos

Page 7: MAICO Product Line: Lançamento€¦ · Frequency Range (kHz) 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnostic: .7-4 TE High Frequencies DPs to 12 kHz N Y NA Default Pass/Refer Y Y

Ero•Scan - OAE Test System Partes & AcessóriosIdeal for...• Audiologists • Physicians• Pediatricians• Birth-to-3 Programs• School and Headstart Programs• Nurseries

Otoacoustic Emissions (OAEs)Otoacoustic emissions are sounds that are produced by the cochlea(outer hair cells) and can be measured in the ear canal. When soundpassing through the ear canal reaches the cochlea, the vibrationstimulates thousands of tiny hair cells. This creates a byproduct thatcan be detected and measured: otoacoustic emissions.

OAEs only occur in a normal cochlea with normal hearing sensitivity.If there is damage to the outer hair cells, which produces hearing loss,then OAEs will not be present. In general, OAEs will be present ifhearing is at 30 dB or better.

PASS test results mean OAEs were detected. If there is damageto the outer hair cells producing a mild hearing loss, OAEs maynot be present. The test result is REFER and the patient may beat risk for possible communication difficulties and can benefitfrom further diagnostic assessment.

This procedure is beneficial in assessing children through a hearing screening program or that cannot be tested by conventional means. For example, pure tone audiometry requires a response from the child which may be an unrealistic expectation and time-consuming.

Ideal for...Visual Evaluation

Ear Canal

Cochlea

OAE Evaluation

Eardrum

TympanometricEvaluation

Middle EarEvaluation

PhysiciansOtoacoustic emissions testing is an ideal tool for hearing screeningbecause it can quickly identify a possible hearing loss and signalreferral for more comprehensive testing.

PediatriciansHearing loss is not always identified by newborn screening.Pediatricians are the first professionals the parents approach withconcerns about their child’s hearing. Since hospital-based and private practice pediatricians screen infants and young children for hearing loss and middle ear disorders, incorporating OAEs into this routine testing can be greatly beneficial.

Head Start and School ScreeningThe MAICO ERO•SCAN is an effective tool for Head Start and school programs as a means to document hearing testing as well as screen large numbers of children very quickly. Since there is no need for a behavioral response from the patient, it is easy to test ESL and special needs children.

Características dos produtos EroScan Screener Plus EroScan Diagnóstico Plus

Portátil Sonda Externa sim sim

4 DP e / ou 6 TE 12 DP e / ou 6 TE Número Máximo de Frequências testadas

Faixa de frequencia em kHz 2-5 DP 1.5-12 DP Screener: 1.5-4 TE Diagnóstico: .7-4 TE

Alta frequencia em DP até 12 kHz nãoPadrão de Passa / Falha Inicio Automático

Numero de Protocólos de teste 2 DP 5 DP Screener: 2 TE Diagnóstico: 3 TE

Bateria recarregável

1000 1000 Número de testes por carga

Memória (# testes)/Máximo 250 250 Testes em todas idadesPacientes com tubos de ventilação

Parametros personalizáveis:

Protocólos de teste personalizáveis

Critério de PASSA personalizável

Faixa de Freq. personalizável

Tempo médio personalizável

# Freq. para PASSAR

Software de banco de dadoscarregar nomes no equipamento

Imprimir pág. completa colorida

Campo para interpretação

●Compatível com software Hi*TRACK / OZ

Impressão de dados numéricos

Impressão de dados gráficos

Date e hora na impressão

maleta de transporteImpressora térmica bluetooth Opcional

Protocolos de testes alterados pela unidade principal (não é necessário software adicional para mudança de protocolos)

Não personalizável sim

Screener and Diagnostic

Impressora Bluetooth e recarregável 105620 *opcional

Carregador EroScan #8029254

Cabo Micro USB #8101864

Tubos da Sonda #8104159

Rolo de papel térmico #8029305

Kit de Olivas #8029306

Sonda #8029264

Maleta de transporte #8104708

vendas: [email protected] - Tel. 11 3363 8888www.maico.com.br

sim sim

simsim simsim sim

sim sim

sim simsim sim

Opcional

Sim - Grátis Sim - Grátis Sim - Grátis

sim sim

sim sim

DPOAE e ou TEOAE

não sim

não sim

não sim

** depende da verão adquirida

não sim

não sim

sim simsim simsim sim

sim simsim simsim sim

DPOAE e ou TEOAE