lvad modular test point physiological simulator valve standard pressure sensor temperature sensor...

6
LVAD Modular Test Point Physiologi cal Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extracti on Test 1 Resistan ce Test 2 PVS Resistan ce Test 3

Upload: bernard-clarke

Post on 16-Dec-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

LVAD

Modular Test Point

Physiological Simulator

Valve

Standard

Pressure Sensor

Temperature Sensor

Flow Sensor

Biocompatible

Blood Extraction

Test 1

Resistance

Test 2

PVS Resistance

Test 3

Page 2: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

LVAD

PVS / Booster

Physiological Simulator

Valve

Valve

Valve

Blood Extraction

Valve

Valve

Automated Resistance

Valve

Valve

Standard

Bio-compatible

Pressure Sensor

Temperature Sensor

Flow Sensor

Not connected for Booster

Page 3: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

LVAD

Blood Extraction /

PVS / BoosterPhysiological

Simulator

Valve

Valve

Valve

Automated Resistance

Valve

Valve

Standard

Bio-compatible

Pressure Sensor

Temperature Sensor

Flow Sensor

Not connected for Booster

Not connected for Blood Extraction

Page 4: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

LVAD

PVS / Booster

Physiological Simulator

Valve

Valve

Valve

Blood Extraction

Valve

Valve

Standard

Bio-compatible

Pressure Sensor

Temperature Sensor

Flow Sensor

Not connected for Booster

Page 5: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

LVAD

PVS / Booster

Physiological Simulator

Valve

Valve

ValveBlood

Extraction

Standard

Bio-compatible

Pressure Sensor

Temperature Sensor

Flow Sensor

Not connected for Booster

Page 6: LVAD Modular Test Point Physiological Simulator Valve Standard Pressure Sensor Temperature Sensor Flow Sensor Biocompatible Blood Extraction Test 1 Resistance

A concept from Dr. Klein who likes blood bags, I guess that where I get it from.

•BB2-Use Blood Pressure cuff to control pressure of system for static testing.

•BB2-Pump BP Cuff to represent heart for dynamic testing.

•BB1-as capacitance chamber

•Should be one way bag

•Should be much larger than BB2, as heart volume is 50cc vs 7-10 quarts? 1000:5 ratio.