low temperature economisers for waste heat …indianpowerstations.org/presentations made at...
TRANSCRIPT
![Page 1: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/1.jpg)
NTPC CONFERENCE
LOW TEMPERATURE
ECONOMISERS FOR WASTE HEAT
RECOVERY
Presentation by Mike Wignall
Group Overseas Operations Director
Greens Holdings
February 2012
1
![Page 2: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/2.jpg)
NTPC CONFERENCE
Greens Holdings/Greens Power
Waste Heat Recovery with Low
Temperature Economisers
Types of Economisers
2
![Page 3: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/3.jpg)
UK based Company
- 178 years old
-Manufacturing Bases in Shanghai
- $136 million turnover
Greens Power
Limited
![Page 4: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/4.jpg)
Edward Green
Founder
1799 - 1865
Greens History
![Page 5: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/5.jpg)
Patented
Fuel Economiser in
1845
![Page 6: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/6.jpg)
Operating Centres Today
• Wakefield, UK
• Shanghai, China
![Page 7: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/7.jpg)
7
WASTE HEAT RECOVERY
TECHNICAL BACKGROUND
![Page 8: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/8.jpg)
8
Why Flue Gas Heat Recovery Required
1.Normal air pre-heater can not help us to reduce the flue gas temperature satisfactorily (recover more heat).
2.Due to soaring fuel price, all power plant facing serious pressure to increase the boiler efficiency. Flue gas loss is the major loss for the boiler , so recovering as more heat as we can from flue gas seemed to be a short cut way.
3.Large quantity cooling water is required to cool the flue gas before the desulphurization for those boilers without GGH.
4.Steam air pre-heater require some steam which will reduce the efficiency of the power plant.
![Page 9: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/9.jpg)
TECHNICAL BACKGROUND
LOW TEMPERATURE
ECONOMISERS
• “OLD” TECHNOLOGY
• SPACE CONSTRAINTS
• PROBLEMS OF “DUST CLOGGING”
• POSSIBLE CORROSION PROBLEMS
• PRESSURE DROP PROBLEM
• STRUCTURAL STEEL COST
![Page 10: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/10.jpg)
10
Technical Solution for Thermal Power Plant Gas Heat Recovery System
System Principle
烟气
回转式空气预热器
干灰
静电除尘器
烟气冷却器
脱硫塔
石灰石
冷却塔
发电机
石膏
干灰
干灰
烟气
Flue Gas
Dry Ash
Dry Ash
Dry Ash
Flue Gas
Flue Gas
Rota
ry A
ir P
reh
eate
r
Cooling Tower
Electrostatic
Precipitator
Generator
Plaster
Desulfurization
Tower
Flue Gas
Cooler
Limestone
![Page 11: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/11.jpg)
11
WASTE HEAT RECOVERY
THE GREENS SOLUTION
4 POSSIBLE SCENARIOS
![Page 12: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/12.jpg)
12
COMMON ARRANGEMENTS FOR GAS HEAT RECOVERY SYSTEMS
Boiler Air Pre-
heater
Boiler
Boiler
Boiler
Air Pre-
heater
Air Pre-
heater
Air Pre-
heater
FD Fan
FD Fan
FD Fan
FD Fan
ESD
ESD
ESD
ESD
Scenario 1 Condensate
Heater
Scenario 2
Two stage Condensate
Heater
Scenario 3 Air Pre-heater
Scenario 4 GGH
Condensate
Condensate
Condensate
Heating Water
Circulating Water
ID Fan
ID Fan
ID Fan
ID Fan
FGD Stack
Stack
Stack
Stack
FGD
FGD
FGD
![Page 13: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/13.jpg)
13
Typical Scenarios for Waste Heat Recovery
1.Scenario 1, Condensate or Heating water heater The flue gas heat recovery system will heat the condensate, then the steam
consumption for the LP heater will be reduced, and then the cycle efficiency will be higher.
Or, the flue gas will heat hot water which could be use for heating or air conditioning. 2.Scenario 2, Two stage Condensate or Heating Water Heater Another set recovery device is located front of the ESP to reduce the flue gas
temperature and then the efficiency of the ESP will be higher. More dust accumulation risk for the device front of ESP 3.Scenario 3, Air pre-heater The flue gas heat recovery device will provide hot water to preheat the combustion air. Not suitable for summer or warm area. 4.Scenario 4, Gas Gas Heater The cold gas at out let of FGD will cool the flue gas at inlet of FGD to reduce the flue
gas temperature. No heat recovery Complicated system
![Page 14: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/14.jpg)
14
Location
•Desulfurization
Tower
![Page 15: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/15.jpg)
15
Field Installation
![Page 16: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/16.jpg)
16
OPERATIONAL ISSUES WITH EXTENDED SURFACE ECONOMISERS
![Page 17: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/17.jpg)
17
Operation
• Clogging Risk
• Ash and high viscosity
substance (gypsum slurry)
• Corrosion Risk
• Last-stage heat exchanger
operated under dew-point
will have high corrosion risk
![Page 18: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/18.jpg)
GREENS SOLUTION
• TOTAL SYSTEM DESIGN REVIEW
+
• GREENS ECONOMISER
32
![Page 19: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/19.jpg)
GREENS SOLUTION
19
•Anti-corrosion Countermeasure
•Use higher grade Material
•Use thick tubes, corrosive allowance
more than 3mm
•Use higher ribbed tube bundles, increase
surface temperature, reduce contact
between bare tube and flue gas
![Page 20: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/20.jpg)
GREENS SOLUTION
ANTI-CLOGGING
LOCATE AFTER ESP
USE DOUBLE H FIN
“IN LINE “ARRANGEMENT
20
![Page 21: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/21.jpg)
GREENS-PROVEN SUCCESS
9 off Projects
3 in Operation-CHINA
6 in Manufacturing/Installation Phase
21
![Page 22: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/22.jpg)
GREENS SUCCESS
SHANGHAI WUJING(600MW)-12 MONTHS OPERATION
JIANSU LIGANG(350MW)-18 MONTHS OPERATION
1.4g/KWh to 1.8g/KWh COAL SAVED
PAY BACK ON INVESTMENT 3.5YEARS(APPROX)
22
![Page 23: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/23.jpg)
GREENS SUCCESS
CHINA REFERENCES-MAINLY TO HEAT
CONDENSATE
INDIA (UCCHPINDA,4 x 360MW) USED TO
DRIVE 800 TR VAHP-BEING DELIVERED
23
![Page 24: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/24.jpg)
GREENS SUCCESS
SPACE PROBLEM?
ACID DEW POINT PROBLEM?
“CLOGGING” PROBLEM?
PRESSURE DROP PROBLEM?
ERROSION PROBLEM?
24
![Page 25: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/25.jpg)
GREENS –ANSWER TO THESE PROBLEMS
STEEL “H” ECONOMISERS
![Page 26: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/26.jpg)
STEEL H is an extended fin tube on Machines designed and built in house to our own specification. 50 years of experience and development. Computer controlled for consistent weld quality.
GREENS STEEL H EXTENDED SURFACE TUBE
Named Steel H because the original fin resembled
The capital letter
‘H’
![Page 27: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/27.jpg)
STEEL H PLATE FIN
• In Line Tube Arrangement with Straight Gas Passages Ensure Low Fouling and Sustained High Efficiency with Dirty Fuels
• More Effective Soot blowing
• Compact Size
• Low Pressure Loss
• Less Tubes and Weight
• Lower Boiler Costs
• Proven Heat Transfer Rates
• Double ‘H’ Inherent Stiffness
GREENS STEEL H ADVANTAGES
![Page 28: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/28.jpg)
15.4632.4
42.13
87.54 96.78
0
50
100Heating
Surface
[ m2 ]
Heating Surface Area
M2 in 1 Cubic Metre of Space.
PS CFS HF Steel H Double Stl H
Single steel H
Helical Fin
![Page 29: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/29.jpg)
29
Steel H vs Spiral/bare Tube
0
10
20
30
40
50
60
70
80
Steel H Bare Tube Spiral Fin
Pressure Drop Heating Area in 1 Cu.M
Steel H is more compacted and low pressure drop.
![Page 30: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/30.jpg)
1515
15
30 30
15 155 510
2020
30 30
10
20 20
35
20
30
30
20
35
35 35
35
3 0
20
20
30
35
G AS F LO W
Research & Development Fins placed in areas of highest heat transfer. Fin weld on sides of tube where maximum heat transfer takes place. Fin material not placed where dust can accumulate above and below the tube. Fin sizes optimised for efficient use of material.
GREENS STEEL H DESIGN
![Page 31: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/31.jpg)
PRECISE INDEXING
![Page 32: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/32.jpg)
PURPOSE BUILT MACHINES
![Page 33: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/33.jpg)
Drax Power Station, UK 6 x 660 MW - Supplied 1st 1970
Babcock Boiler
![Page 34: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/34.jpg)
NANAO Power Station
1 x 700 MW – Supplied 1997
IHI Boiler, JAPAN
![Page 35: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/35.jpg)
DATTLEN Power Station GERMANY
1x 1100 MW
HITACHI Boiler
![Page 36: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/36.jpg)
GREENS ECONOMISERS- STEEL “H” BENEFITS
• Improved Performance
• Lower Capital Costs
• Lower Running Costs
![Page 37: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/37.jpg)
PEAT FUEL BFB BOILER WITH GREENS STEEL H ECONOMISER
GREENS STEEL H CASE STUDY
Case
Stu
dy 1
Economiser
![Page 38: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/38.jpg)
Case
Stu
dy 1
GREENS STEEL H CASE STUDY
CASE SUMMARY
ESB Ireland wanted to know how a plain steel economiser would compare commercially and technically to a Steel H Economiser.
The following is an extract from the presentation made by Greens.
![Page 39: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/39.jpg)
REQUIRED PERFORMANCE DETAILS
• 274MW Peat Fired BFB Boiler.
• Maximum gas velocity 15 m/s.
• Economiser thermal duty 30.5MW
• Chamber Size 6100mm wide x 10700mm long.
• 643 tonnes/hr gas in at 422°C out 283 °C.
• 336 tonnes/hr water in at 258°C and 174.5 bar.
Case
Stu
dy 1
GREENS STEEL H CASE STUDY
![Page 40: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/40.jpg)
P l a i n T u b e S t e e l ‘ H ’
Tube OD, mm Tube Effective Length, mm Tube pitch, h x v, mm Rows wide Rows High Total economiser height, m
42.4
9,000
90 x 90
56
124
16.600
38.1
9,400
79 x 79
70
36
4.685
ARRANGEMENT
STEEL ‘H’ v
PLAIN TUBE
GREENS STEEL H CASE STUDY
Case
Stu
dy 1
![Page 41: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/41.jpg)
P l a i n T u b e S t e e l ‘ H ’
Fin Pitch, mm Total tube used, m Total Heating Surface, m2
Number of Banks Weight Tonnes
N/A
66,525
8,324
6
446
23.5
25,508
12,042
2
240
ARRANGEMENT
STEEL ‘H’ v
PLAIN TUBE
GREENS STEEL H CASE STUDY
Case
Stu
dy 1
![Page 42: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/42.jpg)
P l a i n T u b e S t e e l ‘ H ’
Flue Gas Velocity, max m/s Pressure loss, gas side mm WG Feed water velocity avg, m/s Pressure loss, water side, bar
15.1
160
1.35
2.6
15.0
65
1.35
0.9
OPERATION
STEEL ‘H’ v
PLAIN TUBE
GREENS STEEL H CASE STUDY
Case
Stu
dy 1
![Page 43: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/43.jpg)
P l a i n T u b e S t e e l ‘ H ’
FANS PUMPS TUBE CLEANING (STEAM) TOTAL OPERATIONAL COSTS
23,33,00,000
2,62,00,000
?
25,95,00,000
TOTAL OPERATIONAL COSTS
STEEL ‘H’
v
PLAIN TUBE
Cost of operation assuming 15 years
at 8600 hours and Rs 3.0 kWh
TOTAL OPERATIONAL SAVING WITH STEEL H 154,348,000 ANNUAL OPERATIONAL SAVING WITH STEEL H 10,289,000
9,66,00,000
85,52,000
?
10,51,52,000
GREENS STEEL H CASE STUDY
Case
Stu
dy 1
![Page 44: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/44.jpg)
Case
Stu
dy 2
GREENS STEEL H CASE STUDY
CASE SUMMARY IHI in Japan had an existing coal fired boiler that was under performing. IHI failed to meet customer guarantees. It was decided that if it was possible to improve the economiser performance the overall boiler efficiency would be increased The problem was there was no additional space to add extra heating surface in the chamber so Greens supplied a Steel H Retrofit Economiser
PROJECT: 1 X 600 MW NAKOSO POWER STATION, JAPAN
![Page 45: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/45.jpg)
GREENS STEEL H CASE STUDY
Section of Plain Tube Economiser
Section of Steel H Economiser
Case
Stu
dy 2
![Page 46: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/46.jpg)
GREENS STEEL H CASE STUDY
DETAILS PLAIN TUBE STEEL H
Chamber Size 22413 wide x 5555 long x 1600 high
No. of Tubes 3232 2288
Rows 202 rows (22110mm) 202 rows (22205mm)
High 16 rows (1483mm) 11.3 rows (1100mm)
Gas Temp In oC 488.33
Gas Temp Out oC
423.23 402
Water Temp In oC
278
Water Temp Out oC
308.34 321.1
Duty KW 26672 38674
Case
Stu
dy 2
![Page 47: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/47.jpg)
GREENS STEEL H CASE STUDY
CONCLUSION The Steel H Unit provided a 45% increase in duty and at the same time an effective heating surface for use in boilers with high dust laden fuels. RESULT IHI placed the order for a Steel H unit with Greens
Case
Stu
dy 2
![Page 48: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/48.jpg)
Greens Power High Ash Fuel References (selection from GPL data base)
Power Station Ash content
Tarong, Australia 25 % - 32 %
Vales Point, Australia 34% - 40%
Yue -Yang, China 19.64% - 24.6 %
Dalian, China 19.77 % - 29.77 %
Dandong, China 19.19 % - 28.18 %
Ho-Ping, China 12 % - 16.5 %
Linhuan, China 48.28%
Fengyi, China 47.05%
Gucheng, China 31.45%
Pha-Lai, Vietnam 30.32 %
A Project Japan 34% - 46%
Camden, S Africa 40%
Balco, India 45%
Cadcime, Switzerland >30%
.
Over 70% of UK Coal Fired Power Stations contain a Greens finned tube Economiser which now burn
coals with Ash contents regularly exceeding 20%
![Page 49: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/49.jpg)
Wea
r R
ate
mg k
g-1
30° 60
°
90
°
0°
In line tube arrangements
offer lowest impact angles
and minimum erosion.
From the centre line of the
tube the erosion rate increases
to a maximum at about 30º.
Then decreases rapidly as
angle approaches 0º.
Staggered In-line
![Page 50: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/50.jpg)
Tube protected while fins can collect heat. Minimum loss of heating surface. Stainless Steel notched and formed to suit the tube. Held in place by wrap around the tube.
Ero
sio
n P
rote
ctio
n
GREENS DESIGN EXPERTISE
![Page 51: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/51.jpg)
52
Gas Heat Recovery System Key Technology
③ Use Anti-corrosive material as heat transfer tubes;
Low temperature corrosion Prevention Technology
Cor-Ten & ND Steel
Element C Si Mn P S Cr Cu Sb Ni/Ti
10CrCuSbTi 0.10 0.41 0.61 0.012 0.001 1.01 0.35 0.06 /0.04
09CrCuSb 0.09 0.35 0.52 0.012 0.013 0.88 0.36 0.06 0.05
Carbon Steel & Stainless Steel
Element C Si Mn P S Cr Ni Mo
20G 0.20 0.27 0.50 0.025 0.015 ≤0.25 ≤0.25 ≤0.20
TP316L 0.03 0.55 1.40 0.037 0.006 18.2 10.28 2.07
![Page 52: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/52.jpg)
Boiler electrical output 350MW
Fuel: Coal
Commissioned May1997
Inspection carried
out in April 1998.
Photograph taken
looking down
Through tube in
direction
of gas flow.
![Page 53: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/53.jpg)
Unit #3 Boiler commissioned in 1974
Inspected 31st May 1994.
No cleaning before inspection.
All gas passages clear of fouling.
No ash accumulations.
Recorded on the 25th July 1999.
Unit #1 158,206 hours.
Unit #2 164,888 hours.
Unit #3 161,877 hours.
Unit #4 109,535 hours.
Unit #5 103,863 hours.
Unit #6 99,301 hours.
![Page 54: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/54.jpg)
GREENS SUCCESS-SUMMARY
LOW TEMPERATURE ECONOMISERS FROM
GREENS WILL SAVE YOU MONEY
PROVEN EXPERIENCE OF SAVING AS HIGH AS
1.8g/KWh OF COAL
55
![Page 55: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/55.jpg)
GREENS SUCCESS-SUMMARY
SOLUTION IS:
TOTAL SYSTEM DESIGN APPROACH
+
GREENS STEEL “H” ECONOMISERS
56
![Page 56: LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT …indianpowerstations.org/Presentations Made at IPS-2012/Day-1 at... · LOW TEMPERATURE ECONOMISERS FOR WASTE HEAT ... GREENS STEEL H DESIGN](https://reader034.vdocuments.us/reader034/viewer/2022051508/5aab13707f8b9a693f8b7143/html5/thumbnails/56.jpg)
57
Thank You