  • Copyright 2014 ZES ZIMMER Electronic Systems GmbH

    LMG600 Series Introduction

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Precision in Power

    is the guideline of ZES ZIMMER Electronic Systems GmbH.

    ZES ZIMMER is a German high-tech company specialized in developing, manufacturing and

    distribution of precision instruments and systems for measuring electrical power, energy,

    harmonics, flicker and power quality.

    The company is based in Oberursel, Germany, and was founded in 1980 by

    Dipl.-Ing. Georg Zimmer. It is one of the technical leaders in the field of power analysis

    worldwide.

    ZES ZIMMER offers professional service and support to help customers optimize their

    applications.

    ZES ZIMMER The Touchstone in Power Analysis

    2

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    A New Family of Power Analyzers

    3

    LMG600

    Multi-phase Precision Power Analyzers

    Up to 1000V direct in 10 ranges

    Up to 32A direct in 14 ranges

    DC to 10Mhz

    Innovative DualPath architecture

    Sampling rate 1.2MS/s

    Active power accuracy 0.015% rdg + 0.01% rng

    One power channel can be substituted with

    one process-signal-interface

    Modular 1 - 4 power channels /

    Single channel

    modular 3 - 7 power channels

    LMG640 /LMG610

    LMG670

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    4

    Precision power analyzer

    Measure

    View

    Store and Share

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    5

    Precision power analyzer

    Measure

    Capabilities

    Setup (configuration)

    Extend (CTs and PTs)

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    6

    Precision power analyzer

    Measure

    Capabilities

    Channels

    Filters

    DualPath

    Setup (configuration)

    Extend (CTs, PTs and PSI)

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    A/B/C-Channels 3 Types for Every Application

    7

    Power analyzers are available in different accuracy classes, to allow the user to choose

    the right tool for the job at hand. After all, not all applications require maximum precision;

    often lower resolution and frequency range are sufficient. This is why the LMG600 series

    offers three different channel types, which can be combined in the same chassis without

    problems to ensure that you always have a measuring device tailored to your needs.

    Bandwidth

    Accuracy

    10 kHz 500 kHz 10 MHz

    0.025

    0.04

    0.11

    High-precision measurements at high bandwidth

    Cost-effective broadband measurements

    Precise measurements on 50Hz applications

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Power measurement channels

    8

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Channels Right Type for Every Application. Save Money

    9

    Example: Electric Drive System

    DC

    ACM

    AC

    DC2-4

    1) 2) 3)

    C-channel A/B-channel A/B-channel

    1) Input of the converter: C1-channels are usually sufficient for this.

    2) DC intermediate circuit: depending on the required level of precision, A1 or B1-channels

    are required, as the DC intermediate circuit exhibits significant residual ripple under

    certain circumstances.

    3) Converter output: depending on the required level of precision, A1 or B1-channels only

    are to be used.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Filters. Accuracy without compromise

    10

    In this menu the

    filters and wirings

    can be set.

    For several signals, it is

    necessary to fit filters

    or change the signal

    coupling/wiring to get

    the right values. You

    can adjust this settings

    separately for each

    group.

    You can select Single

    Path or Dual Path signal

    processing

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    DualPath Twice the Results, Half the Time

    11

    Scope display of the voltages at the

    converter output.

    The wideband values ( ) show the

    PWM signal.

    The narrowband values ( ) are

    sinusoidal.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    DualPath Twice the Results, Half the Time

    12

    Simultaneous measurement in two bandwidths

    DualPath - No compromises, No doubt

    The LMG670 was the first power analyzer to have two A/D converters in two independent signal paths for each current and voltage channel. One for the filterless measurement of the wideband

    signal, and a second for the narrowband signal at the output of the anti-aliasing filter. The

    parallel processing of the digitized sample values gives the user access to both measurements

    of the same signal, without risking aliasing effects.

    This unique procedure has established itself for the complete LMG600 series.

    It avoids all of the downsides of previous approaches and guarantees the most precise result in

    the shortest time possible. The LMG600 series power analyzers get all necessary values in one shot.

    Fast. Reliable. No hassle. No compromises. No redundant work.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    13

    Precision power analyzer

    Measure

    Capabilities

    Setup (configuration)

    Groups

    Sync

    Wiring

    Extend (CTs and PTs)

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Group menu

    14

    In this menu the

    filters and wirings

    can be set.

    For several signals, it is

    necessary to fit filters

    or change the signal

    coupling/wiring to get

    the right values. You

    can adjust this settings

    separately for each

    group.

    You can select Single

    Path or Dual Path signal

    processing

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Channel menu

    15

    Set up the

    measuring

    ranges.

    Select voltage and/or

    current input (direct or

    sensor input) and set

    up the ranges manually

    or automatically.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Measuring: 14 Current Ranges, 5 internal shunts

    16

    Direct Input

    5 mA 10 mA 20 mA

    40 mA 80 mA 150 mA

    300 mA 600 mA 1.2 A

    2.5 A 5 A 10 A

    20 A 32 A

    Normal Current Measuring Ranges

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    17

    Precision power analyzer

    Measure

    Capabilities

    Setup (configuration)

    Extend

    CTs

    PTs

    Other Signal I/F

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Sensors: Wideband PT, Precision Current Transducers

    18

    Precision high voltage divider HST for

    3/6/9/12/30kV up to 300kHz, 0.05%.

    Negligible phase error, therefore best suited

    for wideband power measuring.

    Precise current transducersPrec. AC current

    transformer

    Clamp-on

    current sensor

    Prec. wideband

    current transformer

    Hall effect

    current sensors

    Up to 20kV and 10kA DC/AC rms with best accuracy.Plug-and-Measure easy pre-configuration.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Rear side interfaces: PSI

    19

    Process-signal-interface:

    *occupies 1 slot otherwise

    available for 1 power

    measurement channel

    8 digital inputs,

    8 digital outputs,

    2 fast analog inputs (150 kS/s, 15 kHz bandwidth),

    8 slow analog inputs (DC),

    32 analog outputs,

    2 frequency inputs (frequency, orientation, position; TTL, HTL or differential)

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Application: Motor & Drive Total System Efficiency

    20

    Components of the power measurement application with LMG670

    BrakeMotor

    Torque and speed

    sensory

    1- or 3-phase

    source

    Frequency inverter

    Power analyzer

    LMG670

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    21

    Precision power analyzer

    Measure

    View

    Stock Screens

    Custom Screens

    LMG Remote

    Store and Share

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Default Screens

    22

    In this screen all

    important values

    of the measured

    system can be

    read.

    Use the touch screen or

    soft keys to select few

    or many values as well

    as the channel/s.

    Furthermore you can

    choose between

    measure values and

    harmonic analysis via

    soft key Display

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Voltage and Current Screen

    23

    In the Current and Voltage screen

    all important values of the current

    or voltage measurements can be

    read.

    You can also select between Normal and

    Harmonic display.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Power Screen

    24

    In the Power

    screen all

    important values

    of the power

    measurements

    can be read.

    You can also select

    between Normal and

    Harmonic display as

    well as many values

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Energy Screen

    25

    In the Energy

    screen all

    important values

    of the energy

    measurements

    can be read.

    Start, Stop and/or

    Reset your energy

    measurement. All

    channels can be started

    and stopped

    independently from

    each other.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Graph screens: Plot, Scope, Harmonics, Vector

    26

    Up to 8 tracks can

    be graphically

    represented in

    one scope.

    In DualPath mode you

    can track narrow- and

    wideband signals

    simultaneously.

    Cursors can be used to

    obtain values at and

    between cursors.

    In Plot tab you can plot

    measuring values.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    27

    Precision power analyzer

    Measure

    View

    Stock Screens

    Custom Screens

    LMG Remote

    Store and Share

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    28

    Enter CUSTOM menu

    Pre-defined views for introduction and

    measuring examples. Use the first two views

    Introduction 1/2 and Introduction 2/2 to

    get a first impression.

    There are two basic editors:

    Tap short to enter the content editor: show

    the grid, create boxes and add content

    Tap long to enter the layout editor: modify the

    layout, move/remove and/or resize boxes

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    29

    Enter View 6

    Use the empty view to

    customize your own

    menu.

    First you will see soft

    keys to clear/load/save

    menus and/or to set

    the grid/background

    Now we want to build a custom menu step by step to display the power and efficiency of

    a variable frequency drive.

    First, enter the settings as marked to set the grid dimensions.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    30

    Settings

    Set the grid dimensions

    as required. This can be

    specified by the

    required solution for

    the layout or the

    required number of

    parameters etc.

    Enter 12 rows and 24 columns. You will see the grid dimension in the preview.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    31

    Rename

    Give your own menu a

    name by pressing the

    soft key Rename.

    Enter a name for your custom menu.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    32

    Set the title

    Enter the content editor to see the grid. Tap

    longer on the marked box to enter the layout

    editor. The box will be framed in red.

    Tap and hold one corner of the red framed box

    to resize it. Resize it as shown in the left lower

    screenshot.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    33

    Set the title for the menu

    Leave the layout editor and to re-enter the

    content editor. Mark the resized box and press

    the soft key Add Text as marked in the

    screenshot.

    *A text in the custom menu can consist of standard html-notations.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Customize a Screen

    34

    Complete the

    custom menu

    Add all the remaining

    graphs and subtitles as

    shown in the

    screenshot to your

    custom menu.

    To add graphs repeat the procedure as for adding measurands but select Add Graph

    instead in the content menu. In the content editor the scope source can be selected as

    well. The signals shown in the graphs need to be set in the GRAPH menu first.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    35

    Precision power analyzer

    Measure

    View

    Stock Screens

    Custom Screens

    LMG Remote

    Store and Share

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG Remote

    36

    Benefits

    Control the LMG670 remotely from a Windows PC

    LMG Remote mimics the power analyzer itself down to the last detail

    Familiar operation of the measuring device from the PC

    Real-time display of all device functions

    Measuring device LMG670 Software on Windows PC

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG Remote

    37

    Instead of storing the measurement data (.zlr-file, .csv-file) on the device integrated HDD, LMG

    Remote allows the customer to store the files directly on the HDD of your Windows PC.

    Storage menu

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG Remote

    38

    Interface settings

    on LMG670

    Easy setup of the

    interface settings

    Set address masks as

    given from your

    administrator or select

    "DHCP on

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG Remote

    39

    Connection with

    LMG Remote

    Just type the IP-address

    of the measuring

    device and press Enter.

    Afterwards, you can

    start with your remote

    configuration and

    measurement.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    40

    Precision power analyzer

    Measure

    View

    Store and Share

    Logging

    Networks

    Script Editor

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Create ZLR-file

    41

    Enter the Storage-menu and click enter File in the Log-card

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Create ZLR-file

    42

    Select the storage location for the .zlr-file. Name the file and press Enter to get back to the

    Storage menu.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Create ZLR-file

    43

    Press Configure Values to select the single measurement values you want to store. You can

    also select the range in list-values like harmonics e.g. Press enter to get back in the menu.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Create ZLR-file

    44

    Press Create to start/stop continuous storage (one row per cycle) or press Once for single

    shots.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Export CSV-file

    45

    Press Export to enter the Export menu. You can add some or all stored values for export.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Export CSV-file

    46

    You can split the output file by file size or by the number of rows in each file etc.

    Press Enter for selecting the storage location.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Data Storage - Export CSV-file

    47

    Name the .csv-file and press Enter. Now you have exported your stored measurement data.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    48

    Precision power analyzer

    Store and Share

    Logging

    Networks

    Gbit Ethernet

    USB storage

    Serial RS232

    CAN

    Script Editor

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    49

    Precision power analyzer

    Measure

    View

    Store and Share

    Logging

    Networks

    Script Editor

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Script Editor

    50

    Powerful

    programming

    script

    environment for

    application

    computing on

    board.

    Full access to system information

    Create variables and equations for I/O control, Pass/Fail, reporting etc.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 overview

    51

    Precision power analyzer

    Measure

    View

    Store and Share

    Harmonic and Flicker Compliance Testing

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 with LMG Test Suite

    52

    AC source grid impedance

    NI2415-3

    power analyzer LMG670 device

    under test

    EUT

    G~

    G~

    G~

    A

    A

    A

    V VV

    Measurement assembly according to EN61000-3 with LMG670

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 with LMG Test Suite

    53

    CE-Compliance

    The use of power electronics devices causes power or rather current depending noise on the grid or your network, which reduces the quality of your grid voltage or interferes other

    connected devices.

    Therefore, electrical installations, systems and

    equipment must comply with the EU directives and

    regulations, when they are placed on the market

    within the EU.

    Other guidelines for electromagnetic compatibilityand eco-design of energy-using products must be

    observed and fulfilled as well.

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 with LMG Test Suite

    54

    LMG Test Suite

    Only 4 steps for complete

    compliance test including result

    Setup

    File

    Test

    Report

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Series Key Features

    55

    With Interharmonics up to 400th order according EN61000-4-7

    Torque/speed inputs fast & synchronous to rms power values

    Customize your own menu according your demands

    Convenient calculation of all derived variables

    Freely configurable in frequency, type and characteristics

    Adding sensors fast & conveniently while avoiding mistakes

    Up to 4 respectively 7 frequencies concurrently

    Harmonics

    Process Signals

    Custom menu

    Script Editor

    Flexible Filters

    PlugnMeasure

    Synchronization

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    LMG600 Series Key Features

    56

    Interactions between grid and consumers acc. to EN61000-4-15

    Hi-res sample values via interface

    Large 1024x600 display; rapid access to all important menu items

    Real-time display of all device functions via remote operation

    Internal storage even of long-term measurements

    Connectivity with GBit-Ethernet, USB2.0, RS-232 and DVI/VGA

    Flicker

    Sample Values

    Touchscreen

    Remote Control

    Memory

    Interfaces

  • Copyright 2014

    ZES ZIMMER Electronic Systems GmbH

    Thank you for your attention!

    Questions?

    57

    Robert EmersonZES ZIMMER Inc.

    Sales and Application+1 760-550-9371