Life Science Business Unit _ AS Division Ultrafreezers /Irilab Next Series Angelantoni Industrie SpA - AS Biomedical Division Loc. Cimacolle, 464 06056 Massa Martana (PG) Italy telephone +39.075.89551 / telefax +39.075.8955312 [email protected] www.angelantoni.it Copyright © 2009 Angelantoni Industrie SpA /Rev. 00 - 20 /03 / 2010 Illustration, description and technical data may be changed without notice. Life Science Business Unit _ Life Science Business Unit AS - Biomedical Equipment Division Ultrafreezers /Irilab Next Series

Upload: hoangnhi

Post on 20-Mar-2018

213 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Life Science Business Unit AS - Biomedical Equipment ... · PDF fileLife Science Business Unit _ AS Division Ultrafreezers ... is the new control board based on a Microprocessor ARM

Life Science Business Unit _ AS Division

Ultrafreezers /IrilabNext

Series

Angelantoni Industrie SpA - AS Biomedical Division

Loc. Cimacolle, 46406056 Massa Martana (PG) Italytelephone +39.075.89551 / telefax [email protected]

www.angelantoni.it

Copyright © 2009 Angelantoni Industrie SpA /Rev. 00 - 20 /03 / 2010 – Illustration, description and technical data may be changed without notice.

Life Science Business Unit _ Life

Sci

ence

Bus

ines

s Uni

t AS

- Bi

omed

ical

Equ

ipm

ent D

ivisi

on

Ultr

afre

ezer

s /Ir

ilab Ne

xtSe

ries

Page 2: Life Science Business Unit AS - Biomedical Equipment ... · PDF fileLife Science Business Unit _ AS Division Ultrafreezers ... is the new control board based on a Microprocessor ARM

60.000 vials in less than one square meter, guarantees Cold Brain the last frontier in terms of electronic control board to provide the maximum in terms of reliability and control.

01. Irilab Next 800.02. BIOGUARD® opening system (PLUS models).03. Standard opening system (STD models).

3 4

01

Life Science Business Unit _ AS Division

Ultrafreezers /IrilabNext

Series

Large Capacity, Small Footprint / IRILAB Next freezers utilize Vacuum Insulation Panel technology to offer up to 35% more storage capacity than traditionally-insulated lab freezers, without altering external dimensions. Range is programmable up to -85°C (0.1°C increment).

Construction / Reinforced design for long life durability with interior top quality stainless steel (10/10 AISI 304).· Stainless steel shelves adjustable in height.· Stainless steel inventory racks (optional) with cardboard boxes and dividers. · Easy to open door allows one-handed operation, two different configurations are possible: STD means electromagnetic opening system complete with standard key, PLUS means BIOGUARD®, a unique patented transponder opening system which allow manage and monitor samples access.· Inner doors realized with composite materials (aluminium-pvc-aluminium) protect samples and improve energy efficiency.· Easy positioning - freezers are provided with rollers and adjustable feet, all our freezers fit through a standard door. · Standard Port hole (Ø 23 mm).· Heated compensation valve prevents vacuum formation, allowing door to be re opened quickly . · Front-Mounted and Washable Filter is easily accessed without tools.· Ethernet interface provide remote monitoring.

Refrigeration / Cascade refrigeration hermetically sealed two stage cascade system. Refrigerant CFC-Free and HCFC-free.

Sample Security / Total system security and control are ensured through use of multiple sensors (4 PT100 and 4 NTC), and flexible programming of alarms, user ID and passwords. Cold Brain is the new control board based on a Microprocessor ARM (Advanced RISC Machine) with master / slave internal architecture consist in seven sections that duplicates the operating parameters (Safety Mirroring) on different section to ensure maximum reliability in critical situations. In case of master failure, slave sections are able to maintain the proper machine functioning. Cold Brain is equipped with one main section (Master) and six subsections (Slave: GSM, second BIOGUARD® and COLDMINE optional).It’s possible to expand the system.Self-diagnosis for all sections (Token Ring).In case of Master or slave failure the system continues to works thanks to the duplication of the parameters and sends alarm signals.· Multi language (available Italian and English, on request is possible to have all Latin languages).· Graphic display, which implements ’Regulation and Alarms Section’ using 8 soft keys.· On-Screen System Messaging: displays set-points, details of as alarms, door openings and operating conditions. · Integrated Data Recorder, paper chart recorder is replaced with display graphic recorder. Data (alarm and parameters) are recorded for a period of 4 month (every minute). · Audible and Visual Alarms indicate high and low temperature conditions, power failure, low battery, fault conditions as well as when filter needs to be cleaned.

· Alarm Log identifies door open, power failure, electric fault, and sensor failures for cabinet and ambient temperature, and air-cooled and cascade condensers. · Multiuser or Basic security, the customer decides the security level for his sample.· Automatic Restart with non-volatile memory returns set-points to user programmed levels after power failure. · Battery Backup (up to 48 hours) maintains temperature settings and activates alarms during power outage.· Battery State is an actual voltage not percentage to assure that alarms and display will function in the event of power failure.· Integrated predisposition for CO2 & LN2 Backup Systems to protect freezer contents.· Remote Alarm Contact provide connection to an external user-supplied alarm/ monitoring system.· Secure Digital (SD) provide easy data download.· Ethernet Interface provide a connection to a PC located in/out side the Lab to monitor alarms and paramiters status trough Cryolog2, proprietary software to connect up to 30 freezers.· On-Off Switch is located inside the freezer, preventing accidentally shut off.· Low Noise allows freezer to be placed directly in the lab this speeds sample preparation and minimize sample risk.

After-Sales Support / Cold Brain with its on board diagnostics is able to helps service technician to quickly identify the cause of a fault or set-point variance and can be used to identify and correct problems, often over the phone at no charge.That means eliminates unnecessary service calls providing advance diagnosis.

Technical specifications

Optional

Technical specificationsModel IRILAB Next 520 IRILAB Next 800

Capacity (l) 528 813

Max Box capacity (n°) 384 600

Temperature range (°C) -40 /-85 -40 /-80

External dimensions (mm) 730×854×1980 1086×890×1995

Internal dimensions (mm) 586×613×1470 906×609×1472

Refrigerant gas R404 / R508 or mixture

Temperature variations inside the space (°C) ±3 ±2

Temperature variations in time (°C) ±3.5 ±3

Supply voltage 230 V-50 Hz / 115 V-60 Hz / 208-230 V-60 Hz

Noise (dbA) < 53

· Chart recorder· Shelf· Drawer· Dividers· 23-50 mm port hole· Bioguard®

· PT 100 probe· Back-up system (CO2-LN2)· Racks, boxes and dividers· Remote cooling system

Professional Line. Temperature range: -80 /-85°C.