lhc beam instrumentation & future developments

18
LHC Beam Instrumentation & Future Developments Workshop on Optics Measurements, Corrections and Modeling for High-Performance Storage Rings 21 st June 2011, CERN Rhodri Jones (CERN Beam Instrumentation

Upload: nikita

Post on 14-Feb-2016

26 views

Category:

Documents


0 download

DESCRIPTION

LHC Beam Instrumentation & Future Developments. Workshop on Optics Measurements, Corrections and Modeling for High-Performance Storage Rings 21 st June 2011, CERN Rhodri Jones (CERN Beam Instrumentation Group). Outline. Limited to main systems for optics related measurements - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: LHC Beam Instrumentation & Future Developments

LHC Beam Instrumentation&

Future DevelopmentsWorkshop on Optics Measurements, Corrections and Modeling for High-

Performance Storage Rings

21st June 2011, CERN

Rhodri Jones(CERN Beam Instrumentation Group)

Page 2: LHC Beam Instrumentation & Future Developments

Limited to main systems for optics related measurements

● Existing Systems● LHC BPM system● LHC Tune system

● Possible Future systems● Continuous LHC b-beat measurement system● LHC Injection Matching

Outline

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Page 3: LHC Beam Instrumentation & Future Developments

LHC Beam Position Monitors

912 Button Electrode BPMs (24mm)for theMain Arcs & Dispersion Suppressors

24 Directional Couplers52 Enlarged Button& 8 Trigger BPMsInteraction Regions

54 Special BPMs for Tune & Chromaticity,Transverse Damper & RF, Beam DumpInjection Lines: 100 Warm, Button BPMs

(Buttons Recuperated from LEP)36 WarmBPMs -34mm ButtonElectrodes

A total of 1182 BPMsfor the LHC and its Transfer Lines)

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Page 4: LHC Beam Instrumentation & Future Developments

● On line analysis of BPM Data● Powerful on-line tools developed by the CERN Operations crew● Polarity errors easily identified with 45 BPM sampling● Quick indication of phase advance errors

● Some statistics● 2009:

● 4 polarity errors : 2 H to V inversions : 7 BPM mapping errors (LSS8L) ● 1 B1 to B2 inversion

● 2011:● 18 out of 2152 channels with acquisition problems● 50 channels deselected for feedback with physics beams (mainly cross-talk on directional pick-ups)

LHC BPM System Performance I

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Horizontal kick

Vertical kick

Horizontal kick

Vertical kick

Page 5: LHC Beam Instrumentation & Future Developments

● Orbit & BPM Stability● Short term stability (15 minutes) better than 10mm● Alternating high/low peaks follow the beta function indicating that:

● large fraction of this noise results from beam itself● resolution & stability of BPM system orbit mode with single pilot bunch ~5mm

● BUT - surface electronics sensitive to temperature (~50mm per °C)● Currently mitigated by temperature calibration of each channel● Active rack temperature stabilisation being looked into

LHC BPM System Performance IITi

me

of d

ayD

rift (

mm)

rms

nois

e (m

m)

Tim

e of

day

Drif

t (mm

)rm

sno

ise

(mm

)

Horizontal Vertical

Drif

t (mm

)

Drif

t (mm

)

Tim

e of

day

Drif

t (mm

)rm

sno

ise

(mm

)Ti

me

of d

ayD

rift (

mm)

rms

nois

e (m

m)

Tim

e of

day

Drif

t (mm

)rm

sno

ise

(mm

)Ti

me

of d

ayD

rift (

mm)

rms

nois

e (m

m)

Horizontal Vertical

Drif

t (mm

)

Drif

t (mm

)

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Page 6: LHC Beam Instrumentation & Future Developments

● Resolution of LHC BPM system in closed-orbit mode is <5mm rms● Long term stability better than ~100mm

● Mainly given by remaining temperature dependence of surface electronics

LHC BPM System Performance III

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)Courtesy E. Calvo

Page 7: LHC Beam Instrumentation & Future Developments

● Bunch-by-Bunch / Turn-by-Turn Mode● Main mode used for optics measurements in LHC● Allows up to 128000 samples (bunch × turns) from all BPMs

● Read-out limited to few thousand turns due to data transfer & concentration issues● Requires synchronisation to bunch clock for tagging

● Automatic phase-in now possible & performed before all optics measurements● Resolution

● From ~200mm rms (single pilot bunch) to ~50mm rms (single nominal bunch)

LHC BPM System Performance IV

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

-1000

-800

-600

-400

-200

0

200

400

600

800

1000

1E+08 1E+09 1E+10 1E+11

Bunch Intensity (protons)

LHC

Arc

BP

M E

rror

(m m)

0.0

20.0

40.0

60.0

80.0

100.0

BP

M T

rigge

r Rat

e (%

)

Linearity (Lab)Noise (Lab)Arc BPM Trigger Rate

PilotHigh sensitivity

Page 8: LHC Beam Instrumentation & Future Developments

Controlling Tune & Chromaticity using theBase Band Q Measurement (BBQ) System

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Direct Diode Detection (3D)

Base band operationExcellent 24 bit audio ADCs availableSignal conditioning / processing is easy

Courtesy M. Gasior

Page 9: LHC Beam Instrumentation & Future Developments

● Base Band Tune (BBQ) Measurement System● Extremely high sensitivity● Coherent micron level tune

oscillations nearly always observed

● most measurements possible with residual beam oscillations

● Typical tune measurement resolution in the range 10-4 … 10-6

LHC Tune System Performance

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

● Issues● Cohabitation with transverse damper (ADT)

● Raises noise floor by 30dB● Aggressive damping leads to very broad tune peak

Page 10: LHC Beam Instrumentation & Future Developments

● With full pre-cycling the fill-to-fill stability is typically 2-3·10-3

● Variations frequently increase up to 0.02● Due to partial or different magnet pre-cycles after e.g. access or sector trips

● Tune-FB routinely used for all ramps to compensate these effects● Using peak fit on FFT with 0.1..0.3 Hz Bandwidth

Tune Feedback in the LHC

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Hor. spectrum with Tune-FB OFF Hor spectrum with Tune-FB ON

The'hump'

Page 11: LHC Beam Instrumentation & Future Developments

● Q'-Tracker demodulates sinusoidal frequency trims● Increased original modulation of Δp/p from 10-5 @2.5 Hz to 10-4 @2Hz

● Mitigates tune stability effects at injection (ΔQres ~ 3-4·10-4) ● Achieved nominal Q' resolution (±1 unit)

● Used as feed-forward (combined with magnetic model predictions)

Chromaticity Measurement in the LHC

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Q (dotted) and Q' (solid) during snap-back

horizontalvertical

Courtesy R. Steinhagen

Page 12: LHC Beam Instrumentation & Future Developments

● Recent Measurement of Q’’ with and without octupoles at injection

Using the LHC Tune System

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Octupoles on Octupoles off

Page 13: LHC Beam Instrumentation & Future Developments

Future Systems being Developed

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Page 14: LHC Beam Instrumentation & Future Developments

● Makes use of very high sensitivity of BBQ system● Test system acquired using audio acquisition module & proliant machine● ONLY provides PHASE information

● No meaningful turn by turn data

● Advantages● >100 times sensitivity than phase from standard turn by turn BPM data● Minimal excitation required (mm level at any frequency)

● Under test in SPS & the betatron collimation region of LHC● Uses 3 dual plane BPMs

● Phase-advance between consecutive BPMs of Δμ≈ 45°● In parallel to standard BPM system

Continuous Beta Beat Measurements

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Page 15: LHC Beam Instrumentation & Future Developments

● Example from the SPS● Quadrupole trim : 0A → +50A → -50A → 0A● Hysteresis observed

Continuous Beta Beat Measurements

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)

Measured oscillation data(~10-50mm excitation)

Measured change in b

Courtesy R. Steinhagen

Page 16: LHC Beam Instrumentation & Future Developments

● Pre-cycled machine, off-resonance < 1 μm excitation● Excellent phase resolution

● Reduces with energy due to constant kick strength

● Excellent fill-to-fill reproducibility● about 1% provided that the machine was fully pre-cycled

Continuous b-Beat MeasurementsLHC Results

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)Courtesy R. Steinhagen

Page 17: LHC Beam Instrumentation & Future Developments

● Turn by turn OTR monitor● Permanent 2D profile installation as initially hoped not feasible

● high cost & low radiation tolerance of fast cameras● Developing fast 1D array readout for turn by turn profile measurements

LHC Injection Matching Monitor

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)Courtesy S. Burger

Page 18: LHC Beam Instrumentation & Future Developments

● LHC BPM system performing well● Combined with AC dipole excitation provides a very good

tool for optics measurements

● LHC Tune system● Excellent sensitivity allows measurement without excitation

provided transverse damper is not required● Combined with RF frequency modulation allows

measurement of both first & second order chromaticity

● The Future● Continuous b-beta measurement demonstrated

● Could be deployed in critical locations if required BUT● LHC fill-to-fill stability remarkable under full pre-cycle conditions

● New LHC matching monitor being developed for injection optimisation

Summary

OMCM Workshop, CERN, June 2011 Rhodri Jones (CERN BE/BI)