led solutions retrofitsmylpsolutions.com/mylpsolutions/wp-content/uploads/... · specifications...

12
LED SOLUTIONS + RETROFITS MADE IN THE USA

Upload: others

Post on 21-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

LED SOLUTIONS + RETROFITSMADE IN THE

USA

Page 2: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com2

3.030"

.400"

6.060"

6.060"

.375"

.130"

.648"

14W & 23W Tc Point: Inside Lens Cover Below 80˚c13W Tc Point: Inside Lens Cover Below 80˚c

Optional Hardware Includes 4 6-32 X 1/2 Screws & 8 6-32 KEP NutsHARDWARE SOLD SEPERATELY - SEE PAGE 9

OPTIONAL HARDWARE PART # 10-270

POWER OPTIONS @ 80CRI

13W EOS RETROFIT 910lm, 3000K = 70lm/W 1000lm, 4000K = 76lm/W

14W EOS RETROFIT 1350lm, 3000K = 96lm/W 1400lm, 4000K = 100lm/W

23W EOS RETROFIT 1850lm, 3000K = 80lm/W 1900lm, 4000K = 82lm/W

90CRI models special order

3.030"

.400"

6.060"

6.060"

.375"

.130"

.648"

14W & 23W Tc Point: Inside Lens Cover Below 80˚c13W Tc Point: Inside Lens Cover Below 80˚c

Optional Hardware Includes 4 6-32 X 1/2 Screws & 8 6-32 KEP NutsHARDWARE SOLD SEPERATELY - SEE PAGE 9

OPTIONAL HARDWARE PART # 10-270

SL08-AC120R-W-M807PL SL12-AC120R-W-M807PL SL18-AC120R-W-M807PL13W, 910LM, 3000K 14W, 1350LM, 3000K 23W, 1850LM, 3000K

SL08-AC120R-C-M807PL SL12-AC120R-C-M807PL SL18-AC120R-C-M807PL13W, 1000LM, 4000K 14W, 1400LM, 4000K 23W, 1900LM, 4000K

SL08 - AC120R - W - M807PL - MSL08 13W SL12 14W SL18 23W

AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

M807PL HEAT SINK # M MOV SURGE PROTECTION

SL08 - AC120R - W - M807PL - MPART NUMBER GUIDE OPTIONAL

Input Voltage: 120VAC; 50/60Hz

13W, 14W & 23W Models

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Standard mounting options for easy install with optional hardware

Integrated powdercoated aluminum heat sink with ground wire

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL 1598 Classified

FCC compliance Class B

SPECIFICATIONS

Full specifications available on cut sheets

EOS Retrofit Kits available in component form. Contact Lighting Plastics for more information.

UL 1598 Classified Retrofit Kit AC Driver-On-Board Technology Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

EOS LED RETROFIT KITS

install video

RESI 6

Page 3: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com 3

8.125"

8.125"

.375"

4.063"

.130"

.400"

.648"

14W & 23W Tc Point: Inside Lens Cover Below 80˚c13W Tc Point: Inside Lens Cover Below 80˚c

Optional Hardware Includes 4 6-32 X 1/2 Screws & 8 6-32 KEP NutsHARDWARE SOLD SEPERATELY - SEE PAGE 9

OPTIONAL HARDWARE PART # 10-270

POWER OPTIONS @ 80CRI

13W EOS RETROFIT 910lm, 3000K = 70lm/W 1000lm, 4000K = 76lm/W

14W EOS RETROFIT 1350lm, 3000K = 96lm/W 1400lm, 4000K = 100lm/W

23W EOS RETROFIT 1850lm, 3000K = 80lm/W 1900lm, 4000K = 82lm/W

90CRI models special order

8.125"

8.125"

.375"

4.063"

.130"

.400"

.648"

14W & 23W Tc Point: Inside Lens Cover Below 80˚c13W Tc Point: Inside Lens Cover Below 80˚c

Optional Hardware Includes 4 6-32 X 1/2 Screws & 8 6-32 KEP NutsHARDWARE SOLD SEPERATELY - SEE PAGE 9

OPTIONAL HARDWARE PART # 10-270

SL08-AC120R-W-M804PL SL12-AC120R-W-M804PL SL18-AC120R-W-M804PL13W, 910LM, 3000K 14W, 1350LM, 3000K 23W, 1850LM, 3000K

SL08-AC120R-C-M804PL SL12-AC120R-C-M804PL SL18-AC120R-C-M804PL13W, 1000LM, 4000K 14W, 1400LM, 4000K 23W, 1900LM, 4000K

PART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

13W, 14W & 23W Models

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Standard mounting options for easy install with optional hardware

Integrated powdercoated aluminum heat sink with ground wire

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL 1598 Classified

FCC compliance Class B

SPECIFICATIONS

Full specifications available on cut sheets

EOS Retrofit Kits available in component form. Contact Lighting Plastics for more information.

OPTIONAL

UL 1598 Classified Retrofit Kit AC Driver-On-Board Technology Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

EOS LED RETROFIT KITS

SL08 - AC120R - W - M804PL - MSL08 13W SL12 14W SL18 23W

AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

M804PL HEAT SINK # M MOV SURGE PROTECTION

SL08 - AC120R - W - M804PL - M

install video

RESI 8

Page 4: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com4

DIMENSIONS

.50" Center Mount for use with 1/8” IP nipple

3.5"(89mm)

1.08"(27mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

OPTIONAL HARDWARE PART # 10-268

Optional Mounting Hardware Includes2 8-32 X 3/8 TYPE F Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

POWER OPTIONS @ 80CRI

13W EOS RETROFIT 910lm, 3000K = 70lm/W 1000lm, 4000K = 76lm/W

90CRI models special order

SL08-AC120R-W13W, 910LM, 3000K

SL08-AC120R-C13W, 1000LM, 4000K

SL08 - AC120R - W - MSL08 13W AC120R INPUT VOLTAGE W 3OOOK

C 4OOOKM MOV SURGE PROTECTION

SL08 - AC120R - W - MPART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

13W Models

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Standard mounting options for easy install with optional hardware

Integrated powdercoated aluminum heat sink with ground wire

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL 1598 Classified

FCC compliance Class B

SPECIFICATIONS

Full specifications available on cut sheets

EOS Retrofit Kits available in component form. Contact Lighting Plastics for more information.DIMENSIONS

.50" Center Mount for use with 1/8” IP nipple

3.5"(89mm)

1.08"(27mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

OPTIONAL HARDWARE PART # 10-268

Optional Mounting Hardware Includes2 8-32 X 3/8 TYPE F Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

UL 1598 Classified Retrofit Kit AC Driver-On-Board Technology Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

EOS LED RETROFIT KITS

OPTIONAL

install video

PUCK 3.5

Page 5: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com 5

.50" Center Mount for use with 1/8” IP nipple

Key Hole Slots on 2.75" & 3.56"Bolt Circle

Mounting Options

DIMENSIONS

6.18"

(157mm)

1.32"(33mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

OPTIONAL HARDWARE PART # 10-269

Optional Mounting Hardware Includes2 #6 X 3/8 TYPE AB Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

POWER OPTIONS @ 80CRI

14W EOS RETROFIT 1350lm, 3000K = 96lm/W 1400lm, 4000K = 100lm/W

23W EOS RETROFIT 1850lm, 3000K = 80lm/W 1900lm, 4000K = 82lm/W

90CRI models special order

SL12-AC120R-W SL18-AC120R-W14W, 1350LM, 3000K 23W, 1850LM, 3000K

SL12-AC120R-C SL18-AC120R-C14W, 1400LM, 4000K 23W, 1900LM, 4000K

SL12 - AC120R - W - MSL12 14W SL18 23W

AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

M MOV SURGE PROTECTION

SL12 - AC120R - W - MPART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

14W & 23W Models

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Standard mounting options for easy install with optional hardware

Integrated powdercoated aluminum heat sink with ground wire

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL 1598 Classified

FCC compliance Class B

SPECIFICATIONS

Full specifications available on cut sheets

EOS Retrofit Kits available in component form. Contact Lighting Plastics for more information.

.50" Center Mount for use with 1/8” IP nipple

Key Hole Slots on 2.75" & 3.56"Bolt Circle

Mounting Options

DIMENSIONS

6.18"

(157mm)

1.32"(33mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

OPTIONAL HARDWARE PART # 10-269

Optional Mounting Hardware Includes2 #6 X 3/8 TYPE AB Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

OPTIONAL

UL 1598 Classified Retrofit Kit AC Driver-On-Board Technology Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

EOS LED RETROFIT KITS

install video

PUCK 6

Page 6: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com6

1/8" Mounting Holes on 2.18 Bolt Circle

OPTIONAL HARDWARE PART # 10-267Includes 4 #6 X 3/8 TYPE AB Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

.50" Center Mount for use with 1/8” IP nipple(hand tighten to avoid cracking)

Mounting Options

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

.33”(8mm)2.63”

(67mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

POWER OPTIONS @ 80CRI

13W EOS ARRAY 910lm, 3000K = 70lm/W 1000lm, 4000K = 76lm/W

90CRI models special order

L08 13W AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

PART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

13 Watt

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Multiple mounting options for easy install

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL file: E464765 Certified under UL Standard 8750

FCC compliance Class B

SPECIFICATIONS

EOS LED ARRAYS

L08 - AC120R - W

IMPORTANT PRODUCT MUST BE INSTALLED WITH PROPER

HEAT DISSIPATION. SEE UL TERMS OF ACCEPTABILITY

ON PAGE 11 PRIOR TO INSTALLATION.

HEAT SINK NOT INCLUDED

1/8" Mounting Holes on 2.18 Bolt Circle

OPTIONAL HARDWARE PART # 10-267Includes 4 #6 X 3/8 TYPE AB Screws

HARDWARE SOLD SEPERATELY - SEE PAGE 9

.50" Center Mount for use with 1/8” IP nipple(hand tighten to avoid cracking)

Mounting Options

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

.33”(8mm)2.63”

(67mm)

TC POINT: INSIDE LENS COVER BELOW 80˚C

AC Driver-On-Board Technology Multiple Mounting Options Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

13W ARRAY

Page 7: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com 7

1/8" Mounting Holes on 4.46 Bolt Circle

.50" Center Mount for use with 1/8” IP nipple mount(hand tighten to avoid cracking)

Key Hole Slots on 2.75" & 3.56"Bolt CircleMounting Options

.32”(8mm)

5.11”(130mm)

90˚

TC POINT: INSIDE LENS COVER BELOW 80˚C

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

OPTIONAL HARDWARE PART # 10-266Includes 4 8-32 X 3/8 TYPE AB ScrewsHARDWARE SOLD SEPERATELY - SEE PAGE 9

POWER OPTIONS @ 80CRI

14W EOS ARRAY 1350lm, 3000K = 96lm/W 1400lm, 4000K = 100lm/W

90CRI models special order

L12 14W AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

PART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

14 Watt (15W @ 90CRI)

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Multiple mounting options for easy install

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL file: E464765 Certified under UL Standard 8750

FCC compliance Class B

SPECIFICATIONS

EOS LED ARRAYS

L12 - AC120R - W

IMPORTANT PRODUCT MUST BE INSTALLED WITH PROPER

HEAT DISSIPATION. SEE UL TERMS OF ACCEPTABILITY

ON PAGE 11 PRIOR TO INSTALLATION.

HEAT SINK NOT INCLUDED

1/8" Mounting Holes on 4.46 Bolt Circle

.50" Center Mount for use with 1/8” IP nipple mount(hand tighten to avoid cracking)

Key Hole Slots on 2.75" & 3.56"Bolt CircleMounting Options

.32”(8mm)

5.11”(130mm)

90˚

TC POINT: INSIDE LENS COVER BELOW 80˚C

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

OPTIONAL HARDWARE PART # 10-266Includes 4 8-32 X 3/8 TYPE AB ScrewsHARDWARE SOLD SEPERATELY - SEE PAGE 9

AC Driver-On-Board Technology Multiple Mounting Options Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

14W ARRAY

Page 8: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com8

1/8" Mounting Holes on 4.46 Bolt Circle

.50" Center Mount for use with 1/8” IP nipple mount(hand tighten to avoid cracking)

Key Hole Slots on 2.75" & 3.56"Bolt CircleMounting Options

.32”(8mm)

5.11”(130mm)

90˚

TC POINT: INSIDE LENS COVER BELOW 80˚C

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

OPTIONAL HARDWARE PART # 10-266Includes 4 8-32 X 3/8 TYPE AB ScrewsHARDWARE SOLD SEPERATELY - SEE PAGE 9

1/8" Mounting Holes on 4.46 Bolt Circle

.50" Center Mount for use with 1/8” IP nipple mount(hand tighten to avoid cracking)

Key Hole Slots on 2.75" & 3.56"Bolt CircleMounting Options

.32”(8mm)

5.11”(130mm)

90˚

TC POINT: INSIDE LENS COVER BELOW 80˚C

1598C Retrofit Kits, Heat Sinks, &Supplemental Surge Protection Available.Contact Inter-Global for more information

OPTIONAL HARDWARE PART # 10-266Includes 4 8-32 X 3/8 TYPE AB ScrewsHARDWARE SOLD SEPERATELY - SEE PAGE 9

POWER OPTIONS @ 80CRI

23W EOS ARRAY 1850lm, 3000K = 80lm/W 1900lm, 4000K = 82lm/W

90CRI models special order

L18 23W AC120R INPUT VOLTAGE W 3OOOK C 4OOOK

PART NUMBER GUIDE

Input Voltage: 120VAC; 50/60Hz

23 Watt (19W @ 90CRI)

Available in 3000K or 4000K

Constant current design

High power factor > 0.98

Estimated 50,000 hrs L70

Max Lens Temp. (Tc): 80˚C (see below for Tc location)

Optical grade polycarbonate lens

Multiple mounting options for easy install

On board line surge protection

Optional MOV ground surge protection

18" 18 AWG Leads

UL file: E464765 Certified under UL Standard 8750

FCC compliance Class B

SPECIFICATIONS

L18 - AC120R - W

EOS LED ARRAYS AC Driver-On-Board Technology Multiple Mounting Options Data Per NVLAP Accredited Laboratory TRIAC Dimmable To 5% (forward & reverse phase)

Energy Star CSD 5 Year Warranty

IMPORTANT PRODUCT MUST BE INSTALLED WITH PROPER

HEAT DISSIPATION. SEE UL TERMS OF ACCEPTABILITY

ON PAGE 11 PRIOR TO INSTALLATION.

HEAT SINK NOT INCLUDED

23W ARRAY

Page 9: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com 9

2.19"(56mm)

3.5"(89mm)

.75"(19mm)

.50"

6-32 Tapped Hole

90˚

8

10

16

,45

72,3

1153,92

153,92

39,4

19,7

3,86

3,3

3.3

4,2

0,88

2,5

113,2

8

9.53

3,3

5,16

5,26

5,26

5,16

29,7186,858

39,48

10

16,45

19,7

39,4

19,7

3,86113,2

8

3.3

4,2

113.28

206,37

206,37

9,53

3.3

0,88

2,5

72,3

1

3,3

M807PL M804PL6” FLAT SQUARE 8” FLAT SQUARE

2.19"(56mm)

3.5"(89mm)

.75"(19mm)

.50"

6-32 Tapped Hole

90˚

6.18"(157mm)

1"(25mm)

.50"

6-32 Tapped Hole

Key Hole Slots

on 2.75" & 3.56"

Bolt Circle

90˚

EOS800HS EOS1200HS3.5” DIAMETER PUCK 6” DIAMETER PUCK

Ground Wire Included Available in White

ALUMINUM HEAT SINKS

HARDWARE

EOS1200HSEOS800HSM807PLM804PL

10-26713W ARRAY Mounting Hardware

4 #6 X 3/8 TYPE AB Screws

10-26614/23W ARRAY Mounting Hardware

4 8-32 X 3/8 TYPE AB Screws

10-269PUCK 6 Mounting Hardware2 #6 X 3/8 TYPE AB Screws

10-268PUCK 3.5 Mounting Hardware2 8-32 X 3/8 TYPE F Screws

10-270RESI Mounting Hardware

4 6-32 X 1/2 Screws & 8 6-32 KEP Nuts

ACCESSORIES

Page 10: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

Specifications subject to change without notice. Printed in U.S.A. © 2016 Lighting Plastics Solutions

For more information visit www.mylpsolutions.com10

.250.605

.120

1.562

2.975

1.630

.400

.140

6.100

.815

black300V 3ea 18AWG

Radius / ReachSetting

Time OnSetting

Photo eyeDusk to DawnSetting

.250.605

.120

1.562

2.975

1.630

.400

.140

6.100

.815

black300V 3ea 18AWG

Radius / ReachSetting

Time OnSetting

Photo eyeDusk to DawnSetting

MS2B

Input Voltage: 100-277VAC; 50/60Hz

HF System: 5.8GHz CW Radar

2.6W Power Consumption (Static State)

<10mw Transmission Power

Rated Load: 600W @ 100VAC Incandescent 200W @ 277VAC LED 1200W @ 277VAC Incandescent

360˚ Front Detection Angle

160˚ Side Detection Angle

39" to 26′ Adjustable Detection Distance

Timer Reset Adjusts from 8 Seconds to 12 Minutes

Dusk-To-Dawn Sensitivity from 2-2000Lux (2000Lux is OFF)

UL file: E352016

FCC compliance Class B

SPECIFICATIONSCOVERAGE

MICROWAVE SENSOR Adjustable Time, Reach,

& Dusk-To-Dawn Sensitivity Detects Motion Using

Ultra High Frequency Radio Waves Mounting Bracket for Installation Installs Discretely Behind Fixture Lens

MIN.

3’ (1m)

MAX.

20’ (6m)

Installed

inside a wall

mounted

lighting

fixture at a

height of

5’ (1.52m)

18’ (5.5m)

12’ (4m)

6’ (2m)

Installed

inside a

ceiling

mounted

lighting fixture

at a height of

8’ (2.44m)

MAX.

MIN.

18’ (5.5m)

12’ (4m)

6’ (2m)

Ceiling Mount

Wall Mount

NOTE: Coverage pattern will vary based on installation of sensor

and surrounding materials

360˚

MIN.

3’ (1m)

MAX.

20’ (6m)

Installed

inside a wall

mounted

lighting

fixture at a

height of

5’ (1.52m)

18’ (5.5m)

12’ (4m)

6’ (2m)

Installed

inside a

ceiling

mounted

lighting fixture

at a height of

8’ (2.44m)

MAX.

MIN.

18’ (5.5m)

12’ (4m)

6’ (2m)

Ceiling Mount

Wall Mount

NOTE: Coverage pattern will vary based on installation of sensor

and surrounding materials

360˚

NOTE: Coverage pattern will vary based on installation of sensor and surrounding materials.

Supplementary MOV Ground Surge Protector

Use With EOS LED Products in Outdoor Applications

Transient voltage protection: 4.0Kv (32 joules)@140VAC: L-L,L-N,L-G

EOS SURGE PROTECTION

LED-MOV1

ACCESSORIES

Page 11: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions

APPLICATION/SPECIFICATION NOTES

Back Screw MountFront Screw Mount

Length = 1/4"+ Depth of

Threaded Opening

Self Tapping ScrewFour Required(not supplied)

Self Tapping ScrewLength = 1/4" + Heat Sink Thickness

Four required(not supplied)

(not supplied)

(not supplied)

Eos Board

Thermal PadSupplied with

L12-AC120R & L18-AC120Rnot required for L08-AC120R

Heat Sink

Through HoleHeat Sink

Threaded opening

UL Conditions of Acceptability1. The Eos LED Light Engine may be provided with or without lead wires. In cases where lead wires are not provided, wire leads must be evaluated for proper size, operating temperature, and strain relief in final application. Wire connectors provided with the Eos LED Light Engine are rated to accept maximum 18 AWG wires.

2. The Eos LED Light Engine is provided with a polycarbonate lens that is part of the electrical enclosure. Lens must be secured to the printed circuit board in the final application.

3. Temperature must be considered in the final application. The following temperature ratings must not be exceeded: - Printed Circuit Board – 130˚C - Leads – as marked on the insulation - Polycarbonate Lens (Enclosure) – 80˚C - Connectors – 125˚C NOTE: The Eos LED Light Engine must be properly heatsunk to thermal dissipation material. Do not mount the Eos board to insulating material such as glass, steel, plastic, or wood.

4. The Eos LED Light Engine has been evaluated for use in dry or damp locations only. The suitability of the mounting means in the end product shall be determined in the end use evaluation.

5. All Eos LED Light Engine boards are supplied with built in surge protection that provides Energy Star required transient voltage protection of 2.5Kv as outlined in ANSI/IEEE C62.41.1-2002 and considered sufficient for indoor applications. For outdoor applications where products are at higher risk of surges from lightning it is recommended to use a higher level of surge protection. To accomplish this, a supplementary surge protection device is included (LED-MOV1) which aids to provide the transient voltage protection of 4.0Kv that is recommended for those applications.

Application Notes1. Maximum solder point temperature of LEDs must not exceed 100˚C.2. ENERGY STAR - Product is listed on the Energy Star Certified Component Database (CSD) under LED Light Engines. The CSD supports the Luminaire Manufacturer's qualification of their Energy Star Luminiares by providing certified performance data of the components. This streamlines the Energy Star qualification process for the luminaire when CSD listed productsare used.3. TYPICAL MOUNTING DETAIL:

4. Product must be installed with supplied optical lens to comply with UL requirements. Lens must be hand tightened to avoid cracking.5. FLICKER - All lighting systems produce Flicker. Visibility of flicker is highly arbitrary and depends on the surrounding conditions. Visual perception of flicker is negligible at operating frequencies higher than 100Hz. Operating frequencies less than 65Hz are considered unacceptable. The Eos LED Light Engine has an operating frequency greater than 120Hz.6. Eos boards are static sensitive. They must be handled in a manner to protect them from static discharge.7. If additional technical assistance is needed, please contact Inter-Global at 1-800-325-7364.

LED-MOV1 WIRING DIAGRAMLED-MOV1

ELECTRICSUPPLY BOX

Eos PRODUCTBLACK

WHITE

GREEN GROUND

BLACK

WHITE

GREEN GROUND

Eos PRODUCT WARRANTY

APPLICATION/SPECIFICATION NOTES

Lighting Plastics Solutions warrants that its Eos product shall be free from defects in material and workmanship and will be of the designated kind and quality for a period of 5 years from the date of manufacture.

Lighting Plastics Solutions makes no warranty whatsoever with respect to any Eos product not installed and operated in accordance with the current edition of the National Electrical Code, the standards of safety of Underwriters Laboratories, the standards of the American National Standards Institute and specific instructions provided by Lighting Plastics for installation and operation.

If it appears within the said warranty period that any Lighting Plastics Solutions Eos product does not meet the warranty specified above, the customer must give written notice of their warranty claim and return the Eos product with approved Return Authorization (RGA) Number, at the customer’s expense to Lighting Plastics. Within sixty (60) days of receipt, Lighting Plastics shall at its expense and option correct any defects by either repairing or replacing the defective part(s).

This warranty is not applicable to any product subjected to abnormal stresses, abuse, misuse or damage resulting from acts of god.

Lighting Plastics Solution’s Eos Products are designed to be operated in an ambient temperature range of -40C (-40F) to 40C (1 05F)

The foregoing warranty is exclusive of all other statutory written or oral warranties of any kind given or herein expressed. Lighting Plastics Solutions hereby disclaims any implied statutory warranty or implied warranty of merchantability or fitness for a particular purpose.

Under no circumstances whether as a result of breach of contract, breach of warranty, tort strict liability or otherwise, will Lighting Plastics Solutions or any distributor or sales representative be liable for consequential, incidental, special or exemplary damages, including but not limited to loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of substitutes, products facilities or services, down time cost or claims of Lighting Plastics’s customers.

The Liability of Lighting Plastics Solutions or any distributor or sales representative on all claims of any kind for any loss or damage arising out of, resulting from or concerning any aspect of this limited warranty, from the Eos product furnished, shall not exceed the purchase price of the specific Eos product which gives rise to the claims.

REPAIR OR REPLACEMENT FOR Eos PRODUCT UNDER WARRANTY Step 1 Contact Lighting Plastics within 30 days of discovery to explain the nature of the defect: BY PHONE - 1-800-587-3310 BY FAX - 727-446-2451 BY E-MAIL - [email protected]

Step 2 You may be instructed to send some or all of the units back for evaluation. You will be given a Return Authorization (RGA) Number. This number must appear on all cartons, packaging slips, debit memos and other correspondence.

No merchandise will be accepted without a valid RGA number marking the shipment. The Eos product must be returned freight prepaid-COLLECT SHIPMENTS WILL BE REFUSED.

Step 3 The returned Eos product will be evaluated by Lighting Plastics to determine if it is covered under the Limited Warranty.

Eos PRODUCT UNDER WARRANTY - When all of the following conditions exist, the returned Eos product will be considered under warranty and will be repaired or replaced at the option of Lighting Plastics Solutions. 1. The Eos product was manufactured less than the specific warranty period earlier than the date of return.

2. It is determined by Lighting Plastics Solutions that the Eos product was installed and operated in accordance with the current edition of the National Electrical Code, the standards for safety of Underwriter’s Laboratories, Inc. the standards of the American National Standards Institute and the specific instructions provided by Lighting Plastics for installation and operation.

3. The Eos product does not operate according to Lighting Plastics Solutions specifications, due to defects in material or workmanship.

4. The Eos product manufacturing date code has not been altered or is not missing (DATE CODE - Each Eos product is marked with a date code in the form of a sticker or stamped into the case depending on the type of unit). The first two digits represent the year, and the next two digits represent the month of the year of manufacture.

5. The Eos product was not damaged due to physical abuse and was returned in adequate packaging to prevent damage to it.

6. For outdoor installations, the Eos product must be installed with optional surge supression (LED-MOV1).

Eos PRODUCT NOT UNDER WARRANTY - Any Eos product determined by Lighting Plastics Solutions not to be under warranty will be returned to the customer (freight paid by customer), or destroyed, at the customer’s option.

11

Page 12: LED SOLUTIONS RETROFITSmylpsolutions.com/mylpsolutions/wp-content/uploads/... · Specifications subject to change without notice. Printed in U.S.A. 2016 Lighting Plastics Solutions