lasercap operations manual version 3.0 2014

18
LaserCap Operations Manual (ver. 3.0) Notice: LaserCap is not a medical device and is not designed to treat any medical condition. LaserCap is strictly for cosmetic use only. LaserCap is safe when used as directed. LaserCap is distributed specifically for personal home use. U.S. and Int’l Patents Pending. All Rights Reserved. Copyright © 2010-2014 Transdermal Cap, Inc. Authorized Distributor: Bauman Medical Group, P.A. www.baumanmedical.com www.lasercap.info 1

Upload: alan-j-bauman-md

Post on 08-Apr-2015

413 views

Category:

Documents


4 download

DESCRIPTION

The LaserCap Operations Manual includes instructions and specifications of the portable, rechargeable, hands-free LaserCap. LaserCap is a low level laser therapy device for at-home use. LaserCap is available from authorized physician distributor, Dr. Alan J. Bauman of Bauman Medical Group and is manufactured by Transdermal Cap, Inc. Do not stare directly into laser aperture. http://www.baumanmedical.com

TRANSCRIPT

Page 1: LaserCap Operations Manual Version 3.0 2014

LaserCap™ Operations Manual

(ver. 3.0)

Notice: LaserCap™ is not a medical device and is not designed to treat any medical condition. LaserCap™ is strictly for cosmetic use only. LaserCap™ is safe when used as directed. LaserCap™ is distributed specifically for personal home use.

U.S. and Int’l Patents Pending. All Rights Reserved. Copyright © 2010-2014 Transdermal Cap, Inc. Authorized Distributor: Bauman Medical Group, P.A. www.baumanmedical.com www.lasercap.info

1

Page 2: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Table of ContentsParts BreakdownGeneral Safety ChargingHow to Use LaserCap™

LaserCap™ SpecificationsLaser SafetyRecommended Use

MaintenanceStorage / TravelRepair / DispositionWarranty / ReturnsLaserCap RegistrationTroubleshooting

Note: Read the entire manual before operating LaserCap™.

User Assistance Information:Thank you for purchasing LaserCap™. If you have questions or need assistance with this product, contact your authorized LaserCap™ distributor:

2

Bauman Medical Group, P.A.6861 SW 18th St, #102

Boca Raton, FL USA 33433 877.BAUMAN.9 or 877.228.6269 toll-free

1.561.394.0024 [email protected]

www.lasercap.info

Page 3: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Parts Breakdown(1) LaserCap™ (1) Hat(1) PowerPack(1) Charger(1) Protective Case(1) Warranty/Return Policy

Description of Equipment: The three principle components of LaserCap™ are a specialized head-worn array of laser diodes, the rechargeable PowerPack and its Charger.

3

Page 4: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

General Safety

LaserCap™ is safe when used as directed.

LaserCap™ is a laser device. Please adhere to all Laser Safety warnings (p. 9).

Charger is an electrical device. Please adhere to all Electrical Safety warnings (p. 5).

LASER RADIATIONAVOID DIRECT EYE EXPOSURE

4

Page 5: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Charging

Plug Charger into wall outlet, indicator light on Charger should be RED.Turn PowerPack switch to ‘off’ and connect Charger to PowerPack.Indicator light on Charger will turn to GREEN when PowerPack is fully charged.Charging may take several hours. Note: Use only the Charger provided.

5

Indicator Light

Page 6: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

How To Use LaserCap™

Verify PowerPack is fully charged (see p. 5).Disconnect the Charger from the PowerPack.Verify PowerPack switch is ‘off.’Use cable to connect PowerPack to LaserCap™ in a hat.Place hat with LaserCap™ on head.Turn PowerPack switch ‘on.’Observe the PowerPack indicator light blinking green.When use is completed, turn PowerPack switch ‘off.’

6

Page 7: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Using LaserCap™ (tips)You may safely verify LaserCap™ operation by briefly tipping your hat up slightly for one or two seconds while looking in the mirror to view the reflection of the laser light off of your hair and scalp.

Do not stare directly in to laser light. Please refer to p. 9 for Laser Safety.

You may hear a faint clicking sound with each power pulse from the PowerPack; this occurs as the laser diodes within LaserCap™ are powered on.

It is normal for the LaserCap™ and Charger to feel warm during use.

LaserCap™ may be used with or without a hat, if desired.

Battery Pack may be clipped to your belt or placed in your pocket so you may roam freely during use.

After each use, turn PowerPack switch to ‘off.’ LaserCap may then be stored (p. 12) and/or charged (p. 5).

Keep PowerPack fully charged when LaserCap is not in use.

Call 1-877-BAUMAN-9 toll free for usage tips or questions!

7

Page 8: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

LaserCap™ Specifications

Output: 5mW per diode Wavelength: 650nmNumber of divergent laser diodes: 224Total Output Power: 1120mWCoverage area: 336cm2

Factory Preset Duty-Cycle: 80%

Recommended treatment time: 30 min. every other day.Dose Calculation Examples: dose(J) = power(W) * time(s)

2.67mW/cm2 at 80% x 30.0 minutes = 4.8 J/cm2

2.67mW/cm2 at 80% x 6.25 minutes = 1 J/cm2

LaserCap™ is a Class 3R Laser Device. Class 3R lasers are considered safe if handled carefully, with restricted beam viewing. DO NOT STARE DIRECTLY INTO THE LASER LIGHT; please refer to p. 9 for Laser Safety.

8

LASER RADIATIONAVOID DIRECT EYE EXPOSURE

Page 9: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Laser SafetyLASER LIGHT CAN DAMAGE YOUR EYES.

DO NOT STARE AT ANY LASER LIGHT.

DO NOT STARE AT ANY LASER LIGHT THAT IS REFLECTED DIRECTLY FROM LASERCAP™ IN ANY WAY SUCH AS FROM A MIRROR OR OTHER REFLECTIVE SURFACE.

DO NOT ALLOW ANYONE WITHIN VIEWING DISTANCE OF THE LASER LIGHT TO STARE AT IT AND NEVER SHINE THE LASER LIGHT IN ANYONE’S EYES.

DO NOT ATTEMPT TO MAGNIFY OR USE ANY OPTICAL INSTRUMENT OR DEVICE TO ALTER THE LASER LIGHT.

ALWAYS KEEP LASERCAP™ OUT OF REACH OF CHILDREN AND MINORS.

9

Page 10: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Recommended Use

LaserCap™ should be used for 30 minutes, every other day. (See p.8 for dose calculations.)

Note: Your board-certified Hair Restoration Physician may recommend a different regimen.

10

Page 11: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

MaintenanceBefore each use, inspect LaserCap™ PowerPack, Charger and cords for any visible damage.

DO NOT use if LaserCap™, PowerPack, Charger or cords are visibly damaged. LaserCap™ contains NO user-serviceable parts. Contact your authorized distributor for service or replacement instructions.

Cleaning of LaserCap™, PowerPack and Charger:

If necessary, the inner surface of LaserCap™ may be cleaned with a moist cloth or alcohol wipe.

If necessary, the outside of PowerPack/Charger or LaserCap™ may be wiped with a moist cloth.

DO NOT submerge LaserCap™ or its components in water.

11

Page 12: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Storage / Travel

To repack for storage, travel or shipping:Unplug the LaserCap™ from PowerPackUnplug Charger from wall outletPlace PowerPack and Charger in bottom of the carrying casePlace LaserCap™ in carrying case

12

Page 13: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Repair / DispositionLaserCap™ is designed for years of hassle-free use.

LaserCap™ and PowerPack do not contain any user-serviceable parts.

DO NOT attempt to open, repair or modify LaserCap™ or PowerPack. Any attempt to repair or modify LaserCap™ will void the manufacturer’s warranty.

PowerPack contains rechargeable batteries. Please dispose of properly when it has reached the end of its usable life.

Replacement parts and service are available. Contact your authorized distributor, Bauman Medical Group for details. Please refer to p. 19 for contact information.

13

Page 14: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Warranty / ReturnsWarranty/Guarantee: LaserCap™ is guaranteed by the manufacturer to be free from defects in material and workmanship for 3 years from date of purchase from an authorized distributor. If LaserCap™ is determined to be defective, the manufacturer will repair or replace it at no charge during the warranty period.

The Warranty does not cover damage caused by acts of God, misuse, negligence, accident, improper maintenance, connection to improper voltage supply as well as any modification or attempted repair by anyone other than the manufacturer.

The Warranty does not cover LaserCap™ if purchased or obtained from anyone other than an authorized LaserCap™ distributor like Bauman Medical Group.

Returns: LaserCap™ may be returned within 6 months of the date of purchase for any reason minus a 25% restocking fee. All returns must include Proof of Purchase and Registration (see p. 14).

To obtain warranty service or return your LaserCap™, you must first notify your authorized distributor to receive further instructions (see p. 16). All service requests or returns require Proof of Purchase and Registration.

14

Page 15: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

LaserCap Registration

To activate your Warranty and receive important updates regarding LaserCap™, including its use, replacement parts, service, upgrades, tips and techniques, end-user online Registration is required at www.lasercap.info.

Have the following information ready when registering your LaserCap™:

Name Mailing AddressPhone Email Date of Purchase Model # and Serial # of your LaserCap™ (see label near cord on LaserCap™)

Keep your Registration up to date at www.lasercap.info 15

Page 16: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Problems /Troubleshooting

LaserCap™ is designed for years of hassle-free use and guaranteed by the manufacturer to be free of defects in workmanship and manufacturing for 12 months from date of purchase (see p. 12) when purchased through an authorized distributor.

Please review the Operations Manual completely before use.

For any operating problems or any discomfort during or after LaserCap™ use, please discontinue LaserCap™ use immediately, turn PowerPack switch to ‘off,’ remove Charger from wall outlet and call 1-561-394-0024 or email [email protected] to report the problem and seek advice.

16

Page 17: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

For Cosmetic Use

LaserCap™ is distributed by: Bauman Medical Group, P.A. 6861 SW 18th St, Suite 102 Boca Raton, FL 33433 USA 1.877.228.6269 toll-free 1.561.394.0024 phone 1.561.394.4522 fax [email protected]

LaserCap™ is manufactured by: Transdermal Cap, Inc., Mayfield Village, OH 44143 USA.

17

Page 18: LaserCap Operations Manual Version 3.0 2014

LaserCap™ is distributed by BAUMAN MEDICAL GROUP, Boca Raton FL - http://www.lasercap.info

Thank YouThank you for purchasing LaserCap™. For more information about LaserCap™ please contact your Authorized Distributor:

Bauman Medical Group, P.A. 6861 SW 18th St, Suite 102 Boca Raton, FL 33433 USA 1.877.228.6269 toll-free 1.561.394.0024 phone 1.561.394.4522 fax [email protected]

Bauman Medical Group is a medical practice dedicated exclusively to helping patients restore and maintain their own living and growing hair using the latest treatments and procedures. Visit http://www.baumanmedical.com for more information.

18