Page 1: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

LAMP Tunable Wireless Lamp

INSTALLATION GUIDE

Models: S30 PAR 30 LampS38 PAR 38 LampA20 Lamp

Page 2: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 2 770-0000XX-0X r9LAMP INSTALLATION GUIDE

Use in dry locations only. Shock Hazard.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any

interference received, including interference that may cause undesired operation.

Maintain at least 1.8m of spacing between any KetraNet Mesh product and Wi-Fi routers and access points.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

! !WARNING

Page 3: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 3 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

CONTENTS

Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Fixture Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

After Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Warranty/ Tech Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Page 4: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 4 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

PRODUCT OVERVIEW

© 2016 Ketra. Inc. All rights reserved.Designed in Austin, Texas +1.512.872.4349 | www.ketra.com

770-000020-01-6

TUNABLE S30 LED LAMP

Project:

Comments:

Prepared By:

ECO DESCRIPTION

01 ORIGINATED

A

B

C

D

345678

8 7 6 5 4 3

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFKETRA, INC. ANY REPRODUCTION

IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF KETRA, INC.

IS PROHIBITED.

DIMENSIONS ARE IN MILLIMETERSINTERPRET GEOMETRIC TOLERANCING PER: ASME Y14.5 - 2009

DESCRIPTIONUNLESS OTHERWISE SPECIFIED:PRODUCT DOCUMENT

PROPRIETARY AND CONFIDENTIAL

3815 S. CAPITAL OF TEXAS HIGHWAY SUITE 100AUSTIN, TEXAS 78704 (512) 347-1100

DRAWN BY

Vendor

DATE

Vendor PNTHIRD ANGLE PROJECTIONTOLERANCES:

ANGLE +/- 1°

DECIMAL.X +/- 0.5MM.XX +/- 0.25MM

.XXX +/- 0.125MM

DEREK LOGAN 08/31/15

DEVELOPMENTPHASEVERSION

02

Specifications1

Optical Performance

Lumen Output2 825 lm/ 1050 lm

CRI (Ra) >90 (R9 >90)

Lumen Maintenance4 36,000 hours to L70 @ 25°C TA

Color Spatial Uniformity angle

Color Point Maintenance <1 MacAdam ellipse over product lifetime

Equivalent Traditional Lamp 75W halogen PAR30

Dimming Range5 0.1 - 100% lm

Mechanical

Weight 11.95 oz, 339 g

Housing Material Powder Coated Aluminum, Polymer

Lens Material Non-yellowing PMMA

Base Type E26 or GU24

Electrical

Power Consumption S30.08 11W/ S30.10 17W

Power Factor >0.9

Current 170 mA Max

S30.08 75 lm/W / S30.10 62 lm/W

Environmental

Operating Temperature (TA)6 0 - 50°C

Storage Temperature -20 - 80°C

Humidity 0 - 95%, Non-condensing

UL, cUL, RoHS, FCC Class B

Location UL Damp Location, IP20, Suitable for use in fully enclosed luminaires

1 All performance measurements taken at 3000K, 25°C ambient, 100% power input, unless otherwise stated.2 Lumen measurement complies with IES LM-79-08 testing procedures.3 See color gamut chart at the end of this document. 4 Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.5 Intensity and color point controlled via Ketra’s wireless network6Suitable for use in fully enclosed luminaires

PRODUCT WEIGHT

REVISIONSZONE REV. ECO DESCRIPTION DATE APPROVED

C

AA

C

SCALE:

00PRODUCT DOCUMENT DRAWING, A20, 810-000017-XX

775-0000XX-XXPROPRIETARY AND CONFIDENTIAL

BTOLERANCES:

JOHN MICHALKO 9/23/2014

1 11:1PRODUCTION

© 2015 Ketra. Inc. All rights reserved.Designed in Austin, Texas +1.512.347.1100 | www.ketra.com

770-000001-01-16Specifications are subject to change without notice.

TUNABLE S38 LED LAMP

Project:

Comments:

Prepared By:

E26 Base 4.80”, 122 mm ØGU24 Base

4.95

”, 12

6 m

m

4.95

”, 12

6 m

m

4.80”, 122 mm

E26 Base 4.80”, 122 mm ØGU24 Base

4.95

”, 12

6 m

m

4.95

”, 12

6 m

m

4.80”, 122 mm

Specifications1

CAD files available upon request

Optical Performance

Lumen Output2 900 lm/ 1100 lm

CRI (Ra) >90 (R9 >90)

Lumen Maintenance4 36,000 hours to L70 @ 25°C TA

Color Spatial Uniformity <2 MacAdam ellipses across field angle

Color Point Maintenance <1 MacAdam ellipse over product lifetime

Equivalent Traditional Lamp 75W/ 100W halogen PAR38

Dimming Range5 0.1 - 100% lm

Mechanical

Weight 13.8 oz, 390 g

Housing Material Powder Coated Aluminum, Polymer

Lens Material Non-yellowing PMMA

Base Type E26 or GU24

Electrical

Power Consumption S38.09 13W/ S38.11 18W

Power Factor >0.9

Current 170 mA Max

Efficacy S38.09 69 lm/W / S38.11 62 lm/W

Environmental

Operating Temperature (TA)6 0 - 50°C

Storage Temperature -20 - 80°C

Humidity 0 - 95%, Non-condensing

Certification UL, cUL, RoHS, FCC Class B

Location UL Damp Location, IP20, Suitable for use in fully enclosed luminaires

1 All performance measurements taken at 3000K, 25°C ambient, 100% power input, unless otherwise stated.2 Lumen measurement complies with IES LM-79-08 testing procedures.3 See color gamut chart at the end of this document. 4 Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.5 Intensity and color point controlled via Ketra’s wireless network6Suitable for use in fully enclosed luminaires

Accessories

S38 Accessory Snoot 30° cutoff S38ASNT30

S38 Accessory Snoot 55° cutoff S38ASNT55

S38 Accessory Louver 45° cutoff (Requires S38ASNT55) S38ALUV45

S38 Accessory Baffle 15° cutoff (Requires S38ASNT30) S38ABFL15

S30 PAR 30 LONGNECK LAMP A20 LAMP S38 PAR 38 LONGNECK LAMP

Ketra’s Family of lamps are an all-encompassing

LED solution with the ability to render 90+ CRI

white light, saturated colors and pastels from a

fully mixed, single point source.

Ketra’s custom driver chip and optics incorporate closed-loop thermal and optical feedback, maintaining a factory-calibrated color point to one MacAdam ellipse over the product’s lifetime. Each lamp is wirelessly controlled and individually addressable through Ketra’s accompanying software

Page 5: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 5 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

DIMENSION DRAWINGS

© 2016 Ketra. Inc. All rights reserved.Designed in Austin, Texas +1.512.347.1100 | www.ketra.com

770-000017-14

Specifications are subject to change without notice.

A20 TUNABLE LED LAMP

Project:

Comments:

Prepared By:

REVISIONSZONE REV. ECO DESCRIPTION DATE APPROVED

C

AA

C

SCALE:

00PROPRIETARY AND CONFIDENTIAL

BTOLERANCES:

1 21:200

NOTES:

E26 Base

4.95

”, 12

6 m

m

2.52”, 64 mmSpecifications1

CAD files available upon request

Optical Performance

Lumen Output2 600 lm/ 800 lm

CRI (Ra) >90

Lumen Maintenance3 25,000 hours to L70 @ 25°C Ambient

Color Spatial Uniformity <2 MacAdam ellipses across field angle

Color Point Maintenance <1 MacAdam ellipse over product lifetime

Equivalent Traditional Lamp 40W/ 60W Incandescent lamp

Dimming Range4 0.1 - 100% lm

Mechanical

Weight 8.39 oz, 234 g

Housing Material Powder Coated Aluminum, Polymer

Lens Material Non-yellowing PMMA

Base Type E26 GU24

Electrical

Power Consumption A20.06 10W/ A20.08 11W

Power Factor >0.9

Current 100 mA Max

Efficacy >60 lm/W

Environmental

Ambient Operating Temperature5 0 - 50°C

Storage Temperature -20 - 80°C

Humidity 0 - 95%, Non-condensing

Certification UL, cUL, RoHS, FCC Class B

LocationUL Damp Location, IP20,

Suitable for use in fully enclosed luminaires

1 All performance measurements taken at 3000K, 25°C ambient, 100% power input, unless otherwise stated.2 Lumen measurement complies with IES LM-79-08 testing procedures.3 Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.4 Intensity and color point controlled via Ketra’s wireless network5 Suitable for use in fully enclosed luminaires.

PRODUCT WEIGHT

REVISIONSZONE REV. ECO DESCRIPTION DATE APPROVED

C

AA

C

SCALE:

00PRODUCT DOCUMENT DRAWING, A20, 810-000025-XX

775-000005-01PROPRIETARY AND CONFIDENTIAL

BTOLERANCES:

JOHN MICHALKO 4/20/2015

1 21:1DEVELOPMENT03

GU24 Base

4.95

”, 12

6 m

m

2.52”, 64 mm

A20 LAMP

4.95

”, 12

6 m

m

E26 Base

2.52”, 64 mm

© 2015 Ketra. Inc. All rights reserved.Designed in Austin, Texas +1.512.347.1100 | www.ketra.com

770-000001-01-16Specifications are subject to change without notice.

TUNABLE S38 LED LAMP

Project:

Comments:

Prepared By:

E26 Base 4.80”, 122 mm ØGU24 Base

4.95

”, 12

6 m

m

4.95

”, 12

6 m

m

4.80”, 122 mm

E26 Base 4.80”, 122 mm ØGU24 Base

4.95

”, 12

6 m

m

4.95

”, 12

6 m

m

4.80”, 122 mm

Specifications1

CAD files available upon request

Optical Performance

Lumen Output2 900 lm/ 1100 lm

CRI (Ra) >90 (R9 >90)

Lumen Maintenance4 36,000 hours to L70 @ 25°C TA

Color Spatial Uniformity <2 MacAdam ellipses across field angle

Color Point Maintenance <1 MacAdam ellipse over product lifetime

Equivalent Traditional Lamp 75W/ 100W halogen PAR38

Dimming Range5 0.1 - 100% lm

Mechanical

Weight 13.8 oz, 390 g

Housing Material Powder Coated Aluminum, Polymer

Lens Material Non-yellowing PMMA

Base Type E26 or GU24

Electrical

Power Consumption S38.09 13W/ S38.11 18W

Power Factor >0.9

Current 170 mA Max

Efficacy S38.09 69 lm/W / S38.11 62 lm/W

Environmental

Operating Temperature (TA)6 0 - 50°C

Storage Temperature -20 - 80°C

Humidity 0 - 95%, Non-condensing

Certification UL, cUL, RoHS, FCC Class B

Location UL Damp Location, IP20, Suitable for use in fully enclosed luminaires

1 All performance measurements taken at 3000K, 25°C ambient, 100% power input, unless otherwise stated.2 Lumen measurement complies with IES LM-79-08 testing procedures.3 See color gamut chart at the end of this document. 4 Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.5 Intensity and color point controlled via Ketra’s wireless network6Suitable for use in fully enclosed luminaires

Accessories

S38 Accessory Snoot 30° cutoff S38ASNT30

S38 Accessory Snoot 55° cutoff S38ASNT55

S38 Accessory Louver 45° cutoff (Requires S38ASNT55) S38ALUV45

S38 Accessory Baffle 15° cutoff (Requires S38ASNT30) S38ABFL15

S38, PAR 38 LAMP

4.95

”, 12

6 m

m

4.80”, 122 mm

E26 Base

© 2016 Ketra. Inc. All rights reserved.Designed in Austin, Texas +1.512.872.4349 | www.ketra.com

770-000020-01-6Specifications are subject to change without notice.

TUNABLE S30 LED LAMP

Project:

Comments:

Prepared By:

3.7in95.0mm

4.7in

118.6mm

1.0in

25.4mm

2.4in

60.1mm

1.8in

44.7mm

REVISIONSREV. ECO DESCRIPTION DATE APPROVED01 ORIGINATED 08/31/15 DLOGAN

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFKETRA, INC. ANY REPRODUCTION

IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF KETRA, INC.

IS PROHIBITED.

DIMENSIONS ARE IN MILLIMETERSINTERPRET GEOMETRIC TOLERANCING PER: ASME Y14.5 - 2009

DESCRIPTION SIZE REV

SCALE:

UNLESS OTHERWISE SPECIFIED:

01PRODUCT DOCUMENT DRAWING, S30 LN, E26

SHEET

775-000008-01DWG. NO.PROPRIETARY AND CONFIDENTIAL

B3815 S. CAPITAL OF TEXAS HIGHWAY SUITE 100AUSTIN, TEXAS 78704 (512) 347-1100

DRAWN BY

Vendor

DATE

Vendor PNTHIRD ANGLE PROJECTIONTOLERANCES:

ANGLE +/- 1°

DECIMAL.X +/- 0.5MM.XX +/- 0.25MM

.XXX +/- 0.125MM

DEREK LOGAN 08/31/15

Ketra Format REV-03

1 4OF1:1DO NOT SCALE DRAWINGWEIGHT

DEVELOPMENTPHASEVERSION

02

Specifications1

CAD files available upon request

Optical Performance

Lumen Output2 825 lm/ 1050 lm

CRI (Ra) >90 (R9 >90)

Lumen Maintenance4 36,000 hours to L70 @ 25°C TA

Color Spatial Uniformity <2 MacAdam ellipses across field angle

Color Point Maintenance <1 MacAdam ellipse over product lifetime

Equivalent Traditional Lamp 75W halogen PAR30

Dimming Range5 0.1 - 100% lm

Mechanical

Weight 11.95 oz, 339 g

Housing Material Powder Coated Aluminum, Polymer

Lens Material Non-yellowing PMMA

Base Type E26 or GU24

Electrical

Power Consumption S30.08 11W/ S30.10 17W

Power Factor >0.9

Current 170 mA Max

Efficacy S30.08 75 lm/W / S30.10 62 lm/W

Environmental

Operating Temperature (TA)6 0 - 50°C

Storage Temperature -20 - 80°C

Humidity 0 - 95%, Non-condensing

Certification UL, cUL, RoHS, FCC Class B

Location UL Damp Location, IP20, Suitable for use in fully enclosed luminaires

1 All performance measurements taken at 3000K, 25°C ambient, 100% power input, unless otherwise stated.2 Lumen measurement complies with IES LM-79-08 testing procedures.3 See color gamut chart at the end of this document. 4 Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.5 Intensity and color point controlled via Ketra’s wireless network6Suitable for use in fully enclosed luminaires

4.7in

118.8mm

3.7in95.0mm

.3in

6.5mm

.5in13.8mm

2.4in

60.3mm

1.8in

44.7mm

.9in

24.0mm

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFKETRA, INC. ANY REPRODUCTION

IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF KETRA, INC.

IS PROHIBITED.

DIMENSIONS ARE IN MILLIMETERSINTERPRET GEOMETRIC TOLERANCING PER: ASME Y14.5 - 2009

DESCRIPTION SIZE REV

SCALE:

UNLESS OTHERWISE SPECIFIED:

01PRODUCT DOCUMENT DRAWING, S30 LN, GU24

SHEET

775-000008-02DWG. NO.PROPRIETARY AND CONFIDENTIAL

B3815 S. CAPITAL OF TEXAS HIGHWAY SUITE 100AUSTIN, TEXAS 78704 (512) 347-1100

DRAWN BY

Vendor

DATE

Vendor PNTHIRD ANGLE PROJECTIONTOLERANCES:

ANGLE +/- 1°

DECIMAL.X +/- 0.5MM.XX +/- 0.25MM

.XXX +/- 0.125MM

DEREK LOGAN 08/31/15

Ketra Format REV-03

2 4OF1:1DO NOT SCALE DRAWINGWEIGHT

DEVELOPMENTPHASEVERSION

00

S30, PAR 30 LONGNECK LAMP

E26 Base

Page 6: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 6 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

50 FT MAX

NODE NODE NODE

50 FT MAX

50 NODES MAX PER N4

* Ketra’s lighting products should only be controlled via our digital control architecture. Please refer to our controls products for more information

INSTALLATION

FIXTURE PLACEMENT

For ideal KetraNet Mesh wireless performance, position the Lamp according to these guidelines:

• Keep within range: Place the Lamp within 50 ft (15.24m) of at least one or more KetraNet Mesh enabled device in it’s network.

• Avoid obstructions: Avoid having metal obstructions or walls between the Lamp and the nearest device.

• Avoid metal enclosures.

• Separate from Wi-Fi devices: Maintain at least 6 ft (1.8m) of spacing between any KetraNet Mesh product and Wi-Fi routers and access points.

• Avoid obstructions: Avoid having metal obstructions or walls between the Lamp and the nearest device

POWER

The S30, S38, and A20 all require 120 VAC 60 Hz.

Note: Ketra lighting products should not be connected to, or directly controlled by, AC mains line voltage dimmers.* Ketra’s lighting products should only be controlled via our digital control architecture. Please refer to our controls products for more information.

Page 7: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 7 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

INSTALLATION

AFTER INSTALLATION

Ketra lamps power on to a warm white color. They are not controllable until being commissioned in Ketra’s Design Studio software. Commissioning requires at least one Ketra N4 Hub connected to a DHCP-enabled router. For manuals and installation guides, see the Design Studio product page and the N4 Hub product page on our website.

Design Studio product page

N4 Hub product page

Page 8: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance

PAGE 8 770-0000XX-0X r9 LAMP INSTALLATION GUIDE

Limited warranty terms can be found at:

www.ketra.com/warranty

For questions and technical support please contact:

(844) 588-6445

[email protected]

WARRANTY/ TECH SUPPORT

Page 9: LAMP - ketra.com February2018/Pdf/Lamp_Install_8.5X11_v9.pdf · Lumen measurement complies with IES LM-79-08 testing procedures. 3 Lumen maintenance values calculated in accordance