lagoon® advanced care - electrolux professional...lagoon® advanced care wh6-20lac and td6-20lac...

8
PROFESSIONAL LAUNDRY lagoon® Advanced Care WH6-20LAC and TD6-20LAC The ideal replacement for any dry-cleaning operation Features and benefits Keep customers coming back Outstanding results for garments of every type thanks to specialized detergents and dedicated programs Delicate on the delicates Gentle on fine textiles and wools labelled dry-clean only, as less mechanical action. Woolmark-approved Rapid return on investment With a better loading factor, less prespotting, easier finishing and faster pro- cess times Sustainable and eco-friendly Water-based cleaning with none of the disadvantages of PERC, which can be dangerous to staff Dry to dry in 1 hour Smart chemicals and processes mean garments are fully dried in the dryer - no hang-dry

Upload: others

Post on 07-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • PROFESSIONAL LAUNDRY

    lagoon® Advanced CareWH6-20LAC and TD6-20LAC

    The ideal replacement for any dry-cleaning operation

    Features and benefitsKeep customers coming backOutstanding results for garments of every type thanks to specialized detergents and dedicated programs

    Delicate on the delicatesGentle on fine textiles and wools labelled dry-clean only, as less mechanical action. Woolmark-approved

    Rapid return on investmentWith a better loading factor, less prespotting, easier finishing and faster pro-cess times

    Sustainable and eco-friendlyWater-based cleaning with none of the disadvantages of PERC, which can be dangerous to staff

    Dry to dry in 1 hourSmart chemicals and processes mean garments are fully dried in the dryer - no hang-dry

  • WH6-20LAC

    20 14 10 180 725 1055 450 18.0

    22 23 16 20 17 20 110 106 80 85 80 95 0.15/1.0 0.15/1.0 0.05/0.6 0.15/1.0 0.05/0.95 0.05/0.7 65 113+10 0.5/2.2/0.55 45

    TD6-20LAC

    20360 755 18.021.025.0 6.5

    26 25 22 31 23 22 20 28 31 30 27 29

    27 26 23 44 8.2 9.3 9.9 2.99 302 321 352 185 1.00 1.13 1.21 0.36

    Main specifications Rated capacity, Laundry filling factor 1:9 kg Wool filling factor 1:15 kg Silk filling factor 1:18 kgDrum, volume litre diameter ø mm Extraction rpm G-factor Heating alternative electricity kWConsumption data ”lagoon” Total time Wool High min Wool Medium min Silk min Synth. mix Medium min Synth. mix Low min Curtains min Water consumption (cold+hot) Wool High litre Wool Medium litre Silk litre Synth. mix Medium litre Synth. mix Low litre Curtains litre Energy consumption (motor/heating/water) Wool High kWh Wool Medium kWh Silk kWh Synth. mix Medium kWh Synth. mix Low kWh Curtains kWhConsumption data ECO 60 1:9* Total time min Water consumption (cold+hot) litre Energy consumption (motor/heating/hot water) kWh Residual moisture % * Water temperature 15°C cold water and 65°C hot water.

    * 1:30 load 100% wool load at 30% initial moisture dryed to 0%.** 1:40 load 100% synthetic load at 20% initial moisture dryed to 0%.*** At rated capacity 100% cotton load at 50% initial moisture dryed to 0%.

    Main specifications Rated capacity, Drying filling factor 1:18 kgDrum, volume litre diameter ø mm Heating alternative electricity kW gas BTU/h (kW) steam at 700 kPa heat pump kW Consumption data ”lagoon”

    Total time Wool High* min Wool Medium* min Synthetic mix** min Consumption data***

    Total time min Energy consumption (motor/heating/hot water) kWh Evaporation g/min Energy/Water evaporation kWh/l

    El Gas Steam Heat pump

  • WH6-20LAC

    20 200-600

    30 75 170 15

    300-600 5

    17.6 4.2 ± 1.0

    84/68 66/50

    5

    354 1.66

    x x x

    970 945 1410 460 525 1510 1130 150

    1330 400 300 1290 1210 350 100 335 340 215

    220-240V 3 ~ 50/60 18.0 18.5 50 380-415V 3N/3 ~ 50/60 18.0 18.5 35 440V 3 ~ 60 18.0 18.5 25 480V 3 ~ 60 18.0 18.5 25

    220-480V 1 ~ 50/60 - 2.5 10

    A

    C

    1

    2

    B

    E

    D2D1

    3

    IJG

    84

    N

    H

    LK

    11

    12

    F

    9M O

    10

    6 Q7

    P

    5

    Rear

    Side view

    Front

    Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse Hz kW kW A

    Electric heated

    Steam or Non heated

    * Total power and recommended fuse does not depend on the heating power in those cases.

    Water and steam connection

    Water valves DN Water pressure kPa Capacity at 300 kPa l/min Drain valve ø mm Draining capacity l/min Steam valve DN Steam pressure kPa Liquid detergent supplies

    Floor requirements

    Frequency of the dynamic force Hz Floor load at max extraction kN

    Sound levels

    Sound power/pressure level at extraction* dB(A) Sound power/pressure level at wash* dB(A)

    Heat emission

    % of installed power, max

    Shipping data**

    Weight net, kg Shipping volume m3

    Accessories

    Steel base Hose kits for water or steam Fluff collector

    Dimensions in mm

    A Width B Depth C Height D1 D2 E F G H I J K L M N O P Q

    1 Display 2 Door opening ø 435 mm 3 Detergent box 4 Cold/Hot water (Detergent box) 5 Cold water 6 Hot water

    * Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration. Please contact logistics for exact measures.

    7 Cold/Hot water or Re-used water with network pressure (option) 8 Re-used water from tank/pump or Liquid detergent supply 9 Drain 10 Liquid detergent supply 11 Electrical connection 12 Steam connection

  • 220-230V 3 ~ 50/60 18.0 19.0 50 240V 3 ~ 50/60 18.0 19.0 50 380-415V 3N ~ 50/60 18.0 19.0 35 440V 3 ~ 50/60 18.0 19.0 35 480V 3 ~ 60 18.0 19.0 25

    220-240V 3 ~ 50/60 * 1.0 10 380-415V 3N ~ 50/60 * 1.0 10 440V 3 ~ 50/60 * 1.0 10 480V 3 ~ 60 * 1.0 10

    TD6-20LAC

    1” 100-1000

    65 1”

    1/2”

    2000 20

    2800-5000 28-50 200 525 600 690 650 650 650

    72/56

    15

    243 2.07

    790 1200 1340 1770 775 835 750 110 60 270 240 175 605 740 395

    1

    2

    A

    C

    I

    3

    J

    K

    G

    H

    4

    5

    7

    N

    3

    L

    M

    6

    J

    K

    5

    B(a) D

    EF

    B(b)

    Front

    Left side

    Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse Hz kW kW A

    Electric heated

    Gas heated/ Steam heated

    Rear side

    El, gas Steam

    * Total power and recommended fuse does not depend on the heating power in those cases.

    Steam, gas and air connections

    Steam ISO 7/1-R Steam pressure kPa Steam consumption kg/h Condensate ISO 7/1-R Gas ISO 7/1-R Gas pressure Natural gas Pa mbar Propane Pa mbar Air outlet ø mm Evacuated air, el 18.0 kW m3/h gas 21.0 kW steam 25.0 kW Pressure drop el 18.0 kW Max. Pa gas 21.0 kW steam 25.0 kW

    Sound levels

    Sound power/pressure level at drying* dB(A)

    Heat emission

    % of installed power, max

    Shipping data**

    Weight kg Shipping volume crated, m3

    Dimensions in mm

    A Width B(a) Depth, el and gas B(b) Depth, steam C Height D E F G H I J K L M N

    1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection on gas heated machines 4 Gas connection/Electrical connection on electrical heated machines5 Exhaust connection6 Condensate connection7 Steam connection

    Front and side panels in silver grey and dark blue (color samples can be ordered on part number 472998313).* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration. Please contact logistics for exact measures.

  • 220-240V 1/1N ~ 50/60 * 5.5 25 380-415V 3/3N ~ 50/60 * 6.5 10

    TD6-20LAC

    72/56

    15

    308 2.15

    790 1200 1230 1770 775 835 750 110 270 125 260

    D

    EF

    B(a)

    B(b)

    1

    2

    A

    C

    J

    4

    G

    H

    3

    I

    Electrical connections Heating Main voltage Heating Total Recommended alternative power power fuse Hz kW kW A

    Heat pump

    * Total power and recommended fuse does not depend on the heating power in those cases.

    Sound levels

    Sound power/pressure level at drying* dB(A)

    Heat emission

    % of installed power, max

    Shipping data**

    Weight kg Shipping volume crated, m3

    Dimensions in mm

    A(a) Width B(a) Depth B(b) Depth C Height D E F G H I J

    1 Operating panel 2 Door opening ø 580 mm 3 Electrical connection 4 Drain for condense water

    Front

    Left side

    Rear side

    Front and side panels in silver grey and dark blue (color samples can be ordered on part number 472998313).* Sound power levels measured according to ISO 60704.** Average data. Crated weight/shipping volume depends on configuration. Please contact logistics for exact measures.

  • 432731085 432731086

    432731087 432731088

    432731089 432731090

    Electrolux name and description Packaging 20 litres Packaging 10 litres

    W01 - lagoon Sensitive Detergent Professional detergent for natural/animal fiber

    W03 - lagoon Sensitive Conditioner Professional conditioner for natural/animal fiber

    W02 - lagoon Delicate Detergent Professional delicate universal detergent

    For further information including spotting agents, please refer to the lagoon detergent Product Data Sheet

    Jetsave PNCs Description 988930001 Complete kit with 2 pumps, 550 ml/min

    988930002 Complete kit with 3 pumps, 550 ml/min

    988930003 Complete kit with 4 pumps, 550 ml/min

    988930004 Complete kit with 5 pumps, 550 ml/min

    Acessories PNCs Description 988916611 Single low level probe

    432930071 Extension POWER cable (6m)

    432930072 Extension DATA cable (6m)

    988980031 ID interface for 3rd part party peristatic pumps or option for Low level alarm

    432930065 Joining kit

    Power supplyFrom the washer extractor: 100–240V~ 50/60 Hz / 0.1A (Max)

    Water supplyMin. 1.8 bar Max. 6 bar

  • BASE; closed front and sides

    Suitable for models: WH6-20LAC988918871 Height: 230 mmMaterial: Galvanised, silver grey painted steel with stainless steel front panel.

    BASE; “floating foundation”

    Suitable for models: WH6-20LAC 988918872

    Material: Galvanised, silver grey painted steel with stainless steel front panel.

    Feature: A “floating foundation” filled with concrete eliminates noise to other parts of the building.

  • Experience the Excellencewww.electroluxprofessional.com

    Art.

    No.

    438

    9139

    10EN

    /202

    1.03.

    05

    We

    rese

    rve

    the

    right

    to a

    lter s

    pec

    ifica

    tions

    with

    out

    no

    tice.