  • ghamedText Boxsteel comments:1-shoring system for supporting precast beams to be fixed laterally to existing concret wall/columns by suitable shoes and Ledgers2-site Engineers to follow strictly the shown instructions in the shop drawings.3-regarding shoring supprting precast beams , the frame seperation not more than 500mm and Jack extension 200mm4-spacing of secondary /primary beams to be as per submitted design.5-horizontal and vertical spacing of tie rods to be respected 6-vertical stiffeners in the main steel beams at the supporting points to be considered as per submitted design7-add vertical bracing to the shoring of side shuttering as shown8-horizontal and vertical bracing system to be respected code action B