knight wall systems guide details: thermazee … › wp-content › uploads › ...knight...

22
KNIGHT ThermaZee (HORIZONTAL ORIENTATION) RAINSCREEN ATTACHMENT 07/15/2020 KNIGHT WALL SYSTEMS GUIDE DETAILS: ThermaZee (HORIZONTAL) RAINSCREEN ATTACHMENT for CLADDING PANELS HORIZONTAL ORIENTED SYSTEM ThermaZee MINIMUM DEPTH: 1.5 INCHES ThermaZee MAXIMUM DEPTH: 4.5 INCHES (FACE OF SHEATHING TO FACE OF ThermaZee) QUICK LINK: SECTION VIEW PLAN VIEW THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLY AND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THE ATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING IS AVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e. FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHER DETAILS. ALL IMPLIED WARRANTIES INCLUDING MERCHANTABILITY & FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. www.knightwallsystems.com © Knight Wall Systems Deer Park, WA - 1.855.KWS.WALL PATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

Upload: others

Post on 29-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    KNIGHT WALL SYSTEMS GUIDE DETAILS:ThermaZee™ (HORIZONTAL)

    RAINSCREEN ATTACHMENT for CLADDING PANELS

    HORIZONTAL ORIENTED SYSTEMThermaZee MINIMUM DEPTH: 1.5 INCHESThermaZee MAXIMUM DEPTH: 4.5 INCHES

    (FACE OF SHEATHING TO FACE OF ThermaZee)

    QUICK LINK: SECTION VIEW PLAN VIEW

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

  • KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/152020

    GENERAL NOTES:

    · KNIGHT WALL SYSTEMS (KWS) IS NOT RESPONSIBLE FOR INFORMATION SHOWN ON ALL DETAILS BEYOND KWSSPECIFIC SCOPE OF WORK QUOTED AND AS INDICATED ON CONTRACT DOCUMENTS.

    · SYSTEM MAY BE INSTALLED OVER STEEL STUDS, WOOD STUDS, CMU OR CONCRETE SUBSTRATES (WITH USE OFAPPROPRIATE WALL ANCHORS).

    · PROJECT SPECIFIC ENGINEERING CAN BE PROVIDED BY KWS AND IS REQUIRED FOR A 10 YEAR LIMITEDWRITTEN WARRANTY.

    · KWS PROJECT SPECIFIC ENGINEERING, IF SUPPLIED, IS LIMITED TO THE LOAD CARRYING COMPONENTS OF THEPRODUCTS AND FASTENERS SUPPLIED BY KWS. THE BACK-UP WALL, WALL CLADDING PANELS AND/OR RAILSSUPPLIED BY OTHERS ARE WITH OTHER PARTIES.

    · PLEASE READ OUR INSTALLATION AND DESIGN RECOMMENDATIONS DOCUMENT FOR FURTHER INFORMATIONTHAT IS IMPORTANT FOR YOUR SPECIFIC PROJECT AND PROPER INSTALLATION.

    · DETAILS OF ADJACENT WORK ARE SHOWN FOR COMPLETENESS, CLARITY AND CONVENIENCE AS AN EXAMPLE OFA BUILT ENVIRONMENT ONLY.

    · THE STRUCTURAL SUPPORT, BACK-UP WALL AND SUPER STRUCTURE DESIGN IS WITH OTHER PARTIES (SUCH AS,BUT NOT LIMITED TO, STEEL STUD WALL, etc.). THE RESPONSIBILITY FOR THESE OTHER ASSEMBLIES TOACCOMMODATE ALL LOADS IMPOSED UPON THEM BY KWS PRODUCTS, OR ANY ATTACHMENT OR PANEL SYSTEM,SHOULD BE CONSIDERED.

    · SOFT JOINTS, SEALANT AND FLASHING SPECIFICATIONS, DESIGN AND INSTALLATION ARE WITH OTHER PARTIES.· WEATHER RESISTANT/AIR BARRIER AND INSULATION SPECIFICATIONS, DETAILING AND INSTALLATION,

    INCLUDING PENETRATIONS, ARE WITH OTHER PARTIES.· INTERACTION BETWEEN DISSIMILAR MATERIALS, SUCH AS ALUMINUM AND STEEL, CAN BE SEPARATED VIA

    PLASTIC SHIMS, TAPE OR COATING TO PREVENT GALVANIC REACTION.· USE SHEARING INSTRUMENTS FOR CUTTING METAL FRAMING COMPONENTS. SAWS ARE NOT RECOMMENDED, AS

    THE SPARKS PRODUCED DURING CUTTING WILL DAMAGE THE ANTI-CORROSION COATING. IF SPARKS AREGENERATED DURING CUTTING, BE SURE THE PORTION OF THE COMPONENT TO BE INSTALLED ON THE BUILDINGIS PROTECTED FROM SPARKS. THE SYSTEMS COMPONENTS MUST NOT BE CUT WHILE INSTALLED ON THEBUILDING UNLESS USING A SHEARING INSTRUMENT (I.E. SNIPS, etc.).

    · USE OF IMPACT DRIVERS IS NOT RECOMMENDED WHEN DRIVING ANY FASTENER FOR THE SYSTEM.· EXTERIOR INSULATION IS RECOMMENDED TO BE MINERAL FIBER INSULATION (MFI) FOR USE WITH THE

    ThermaZee. RIGID FOAM INSULATION MAY BE USED, BUT IS NOT RECOMMENDED DUE TO THERMAL ISOLATIONBASE DESIGN AND EXCESS LABOR FOR TRIMMING OR CUTTING OF RIGID FOAM. MINERAL FIBER INSULATIONDOES NOT TYPICALLY REQUIRE ANY CUTTING AROUND THE BASE FOR PROPER INSTALLATION.

    · ThermaZee, RevealRail, PanelRail and ThermaStop are trademarks of Knight Wall Systems, inc.· THE DETAILS WITHIN THIS DRAWING PACKAGE ARE NOT INTENDED TO REPLACE PROJECT SPECIFIC

    ENGINEERING CALCULATIONS OR THE DESIGN SERVICES OF A REGISTERED PROFESSIONAL DESIGNER AND ARESUBJECT TO CHANGE AT ANY TIME.

    NOTICE: No freedom from any patent owned by Knight Wall Systems or others is to be inferred. Because use conditions and applicable laws maydiffer from one location to another and may change with time, Customer is responsible for determining whether products and the information in thisdocument are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable lawsand other government enactments. Knight Wall Systems assumes no obligation or liability for the information in this document. NO EXPRESSWARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN LIMITED WARRANTIES SPECIFICALLY PROVIDED BY KNIGHTWALL SYSTEMS. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSEARE EXPRESSLY EXCLUDED. Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential formold formation. No material supplier including Knight Wall Systems can give assurance that mold will not develop in any specific system.

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

  • KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    TABLE OF CONTENTS:

    1. TITLE PAGE2. GENERAL NOTES3. TABLE OF CONTENTS

    4. ISOMETRIC VIEW OF ThermaZee™ ASSEMBLY5. 1.5"-2.5" ThermaZee OVERALL DIMENSIONS6. 3"-4.5" ThermaZee OVERALL DIMENSIONS7. TYPICAL SECTION VIEW - HORIZONTAL ThermaZee ONLY8. TYPICAL PLAN VIEW - HORIZONTAL ThermaZee ONLY9. TYPICAL OUTSIDE CORNER - HORIZONTAL ThermaZee ONLY10. TYPICAL INSIDE CORNER - HORIZONTAL ThermaZee ONLY11. TYPICAL JAMB CONDITION - HORIZONTAL ThermaZee ONLY12. TYPICAL HEAD/SILL CONDITION - HORIZONTAL ThermaZee ONLY13. TYPICAL BASE OF WALL - HORIZONTAL ThermaZee ONLY14. TYPICAL DEFLECTION FLOOR JOINT - HORIZONTAL ThermaZee ONLY15. TYPICAL SECTION VIEW - HORIZONTAL ThermaZee + VERTICAL PanelRail16. TYPICAL PLAN VIEW - HORIZONTAL ThermaZee + VERTICAL PanelRail17. TYPICAL OUTSIDE CORNER - HORIZONTAL ThermaZee + VERTICAL PanelRail18. TYPICAL INSIDE CORNER - HORIZONTAL ThermaZee + VERTICAL PanelRail19. TYPICAL JAMB CONDITION - HORIZONTAL ThermaZee + VERTICAL PanelRail20. TYPICAL HEAD/SILL CONDITION - HORIZONTAL ThermaZee + VERTICAL PanelRail21. TYPICAL BASE OF WALL - HORIZONTAL ThermaZee + VERTICAL PanelRail22. TYPICAL DEFLECTION FLOOR JOINT - HORIZONTAL ThermaZee + VERTICAL PanelRail

    PLEASE FEEL FREE TO CONTACT KWS OR A LOCAL KWS REPRESENTATIVE FOR PROJECTSPECIFIC ASSISTANCE WITH DETAILS AND SPECIFYING.1.855.KWS.WALLinfo@knightwallsystems.comwww.knightwallsystems.com

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

  • STEEL, REINFORCED, PERFORATED, Z,18 GAUGE (46 MIL), 50 KSI,ASTM A1046 ZM40 Zn-Al-Mg

    ULTRA ANTI-CORROSION COATING,BY KWS

    WALL ANCHOR WITHOPTIONAL ThemaStop WASHER,

    CAN BE SUPPLIED BY KWS

    ThermaStop THERMAL ISOLATION STRIP,PRE-ASSEMBLED, BY KWS

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    ThermaZee ASSEMBLY - ISO VIEW4 SCALE: 3" = 1'-0"

    & MW

  • 1.5" ThermaZee158"

    112"

    13 4"

    158"

    2"

    13 4"

    12"

    14" 1

    14"

    14" 1

    34"

    158"

    212"

    13 4"

    14" 2

    14"

    2.0" ThermaZee 2.5" ThermaZee1

    2"

    12"

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    ThermaZee SIZES - 1.5"-2.5"5 SCALE: 3" = 1'-0"

    & MW

  • 158"

    3"

    13 4"

    14" 2

    34"

    158"

    312"

    13 4"

    14" 3

    14"

    158"

    4"

    13 4"

    14" 3

    34"

    158"

    412"

    13 4"

    14" 4

    14"

    3.0" ThermaZee 3.5" ThermaZee

    4.0" ThermaZee 4.5" ThermaZee

    12"

    12"

    12"

    12"

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    ThermaZee SIZES - 3"-4.5"6 SCALE: 3" = 1'-0"

    & MW

  • BY OTHERS

    AIR/MOISTURE BARRIER,NOT BY KWS

    BACK-UP WALL ASSEMBLY(STEEL STUD - 18 GA MIN.

    or WOOD STUD or CMUor CONCRETE), NOT BY KWS

    TEK SCREW w/ThermaStop™THERMAL ISOLATION WASHER,

    BY KWS

    ThermaZee™, 1.5-4.5", 18 gauge, 50 ksi,ASTM A1046 ZM40 Zn-Al-Mg ULTRA

    ANTI-CORROSION COATING, withThermaStop™ THERMAL ISOLATION STRIP,

    BY KWS

    MINERAL FIBER INSULATION,NOT BY KWS

    CLADDING PANEL,NOT BY KWS

    CLAD

    DING

    TYP

    E &

    WIN

    D PR

    ESSU

    RES

    DEPE

    NDEN

    T(T

    YPIC

    ALLY

    24"

    O.C

    .; 12

    "-48

    " O.C

    .)

    1.5"-4.5"INSULATION

    SYSTEM MAY BE INSTALLED OVER STEEL STUDS,WOOD STUDS, CMU OR CONCRETE SUBSTRATES(WITH USE OF APPROPRIATE WALL ANCHORS).

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL SECTION VIEW - ThermaZee ONLY7 SCALE: 3" = 1'-0"

  • 16" -24" O.C.(CLADDING TYPE & WIND PRESSURES DEPENDENT)

    MINERAL FIBER INSULATION,NOT BY KWS

    TEK SCREW w/ThermaStop™THERMAL ISOLATION WASHER,

    BY KWS

    AIR/MOISTURE BARRIER,NOT BY KWS

    SYSTEM MAY BE INSTALLED OVER STEEL STUDS,WOOD STUDS, CMU OR CONCRETE SUBSTRATES(WITH USE OF APPROPRIATE WALL ANCHORS).

    CLADDING PANEL, NOT BY KWS

    ThermaZee™, 1.5-4.5", 18 gauge, 50 ksi,ASTM A1046 ZM40 Zn-Al-Mg ULTRAANTI-CORROSION COATING, withThermaStop™ THERMAL ISOLATION STRIP,BY KWS

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL PLAN VIEW - ThermaZee ONLY8 SCALE: 3" = 1'-0"

  • BACKING ('L') MAY BE REQUIREDAT OUTSIDE CORNER. CONSULTCLADDING MANUFACTURER FOR

    DETAILS & REQUIREMENTS.THIS IS NOT REQUIRED OR

    SUPPLIED BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL OUTSIDE CORNER9 SCALE: 3" = 1'-0"

  • BACKING ('L') MAY BE REQUIREDAT INSIDE CORNER. CONSULT

    CLADDING MANUFACTURERFOR DETAILS & REQUIREMENTS.

    THIS IS NOT REQUIRED ORSUPPLIED BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL INSIDE CORNER10 SCALE: 3" = 1'-0"

  • * FLASHING DETAILS VARY BASED ON WINDOW TYPE,POSITION (INSET VS FLUSH) AND CLADDING TYPE.FLASHING IS NOT BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL JAMB CONDITION11 SCALE: 3" = 1'-0"

  • * FLASHING DETAILS VARY BASED ON WINDOW TYPE,POSITION (INSET VS FLUSH) AND CLADDING TYPE.FLASHING IS NOT BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL HEAD & SILL CONDITION12 SCALE: 3" = 1'-0"

  • 3 4" MIN.

    * CLEAR & UNRESTRICTED VENTILATION & DRAINAGEREQUIRED AT BASE OF WALL

    SHEET METAL DRIPFLASHING, PRE-FINISHED, NOT BY KWS

    A/B SEALANT,NOT BY KWS

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL BASE OF WALL CONDITION13 SCALE: 3" = 1'-0"

  • FLOOR DEFLECTION TRACK,BY OTHERS

    A BREAK/MOVEMENT JOINT INCLADDING MUST COINCIDE WITHBREAK IN ATTACHMENT SYSTEMAND FLOOR DEFLECTION JOINTS

    TO PREVENT DAMAGE AND STRESSON WALL SYSTEM, CONSULT CLADDING

    MANUFACTURER FOR DETAILS,NOT BY KWS

    GAP BETWEEN RAILS TYPICALLYEQUALS 1.5x THE EXPECTED

    FLOOR MOVEMENT, MINIMUMOF 38" AND MAXIMUM OF 1"

    ThermaZee MUST NOT INFRINGE ONSTEEL STUD FLOOR DEFLECTION

    TRACK MOVEMENT

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL FLOOR DEFLECTION JOINT14 SCALE: 3" = 1'-0"

  • BY OTHERS

    AIR/MOISTURE BARRIER,NOT BY KWS

    BACK-UP WALL ASSEMBLY(STEEL STUD - 18 GA MIN.

    or WOOD STUD or CMUor CONCRETE), NOT BY KWS

    TEK SCREW w/ThermaStop™THERMAL ISOLATION WASHER,

    BY KWS

    ThermaZee™, 1.5-4.5", 18 gauge, 50 ksi,ASTM A1046 ZM40 Zn-Al-Mg ULTRA

    ANTI-CORROSION COATING, withThermaStop™ THERMAL ISOLATION STRIP,

    BY KWS

    MINERAL FIBER INSULATION,NOT BY KWS

    2"-5" PanelRail™, 18 gauge, 50 ksi,ASTM A1046 ZM40 Zn-Al-Mg ULTRA

    ANTI-CORROSION COATING, BY KWS

    CLADDING PANEL,NOT BY KWS

    CLAD

    DING

    TYP

    E &

    WIN

    D PR

    ESSU

    RES

    DEPE

    NDEN

    T(T

    YPIC

    ALLY

    24"

    O.C

    .; 12

    "-48

    " O.C

    .)

    3 4" 1.5"-4.5"INSULATION

    2 14" - 5 14"TOTAL DEPTH

    SYSTEM MAY BE INSTALLED OVER STEEL STUDS,WOOD STUDS, CMU OR CONCRETE SUBSTRATES(WITH USE OF APPROPRIATE WALL ANCHORS).

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYP SECTION VIEW - ThermaZee + PanelRail15 SCALE: 3" = 1'-0"

  • 16" -24" O.C.(CLADDING TYPE & WIND PRESSURES DEPENDENT)

    DETERMINED BY DESIGN WIND PRESSURE(AND AS REQUIRED BY PANEL MANUFACTURER)

    MINERAL FIBER INSULATION,NOT BY KWS

    STAINLESS STEEL TEK SCREWw/1,000 HR SALT SPRAY

    COATING, BY KWS

    2"-5" PanelRail (2" SHOWN), 18 gauge,50 ksi, ASTM A1046 ZM40 Zn-Al-Mg ULTRA

    ANTI-CORROSION COATING, BY KWS

    TEK SCREW w/ThermaStop™THERMAL ISOLATION WASHER,

    BY KWS

    AIR/MOISTURE BARRIER,NOT BY KWS

    SYSTEM MAY BE INSTALLED OVER STEEL STUDS,WOOD STUDS, CMU OR CONCRETE SUBSTRATES(WITH USE OF APPROPRIATE WALL ANCHORS).

    CLADDING PANEL, NOT BY KWS

    ThermaZee™, 1.5-4.5", 18 gauge, 50 ksi,ASTM A1046 ZM40 Zn-Al-Mg ULTRAANTI-CORROSION COATING, withThermaStop™ THERMAL ISOLATION STRIP,BY KWS

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYP PLAN VIEW - ThermaZee + PanelRail16 SCALE: 3" = 1'-0"

  • BACKING ('L') MAY BE REQUIREDAT OUTSIDE CORNER. CONSULTCLADDING MANUFACTURER FOR

    DETAILS & REQUIREMENTS.THIS IS NOT REQUIRED OR

    SUPPLIED BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL OUTSIDE CORNER17 SCALE: 3" = 1'-0"

  • BACKING ('L') MAY BE REQUIREDAT INSIDE CORNER. CONSULT

    CLADDING MANUFACTURERFOR DETAILS & REQUIREMENTS.

    THIS IS NOT REQUIRED ORSUPPLIED BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL INSIDE CORNER18 SCALE: 3" = 1'-0"

  • * FLASHING DETAILS VARY BASED ON WINDOW TYPE,POSITION (INSET VS FLUSH) AND CLADDING TYPE.FLASHING IS NOT BY KWS.

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL JAMB CONDITION19 SCALE: 3" = 1'-0"

  • * FLASHING DETAILS VARY BASED ON WINDOW TYPE,POSITION (INSET VS FLUSH) AND CLADDING TYPE.FLASHING IS NOT BY KWS.

    BASED ON MAXCANTILEVEROF PanelRail

    (CLADDING TYPE &WIND PRESSURE

    DEPENDENT)

    BASED ON MAXCANTILEVEROF PanelRail

    (CLADDING TYPE &WIND PRESSURE

    DEPENDENT)

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL HEAD & SILL CONDITION20 SCALE: 3" = 1'-0"

  • 3 4" MIN.

    * CLEAR & UNRESTRICTED VENTILATION & DRAINAGEREQUIRED AT BASE OF WALL

    SHEET METAL DRIPFLASHING, PRE-FINISHED, NOT BY KWS

    A/B SEALANT,NOT BY KWS

    BASED ON MAXCANTILEVEROF PanelRail

    (CLADDING TYPE &WIND PRESSURE

    DEPENDENT)

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL BASE OF WALL CONDITION21 SCALE: 3" = 1'-0"

  • FLOOR DEFLECTION TRACK,BY OTHERS

    NOTE:MAXIMUM PanelRail CANTILEVERBEYOND A ThermaZee VARIESPER PROJECT. TYPICALLY ITWILL RANGE FROM 6"-14".

    A BREAK/MOVEMENT JOINT INCLADDING MUST COINCIDE WITHBREAK IN ATTACHMENT SYSTEMAND FLOOR DEFLECTION JOINTS

    TO PREVENT DAMAGE AND STRESSON WALL SYSTEM, CONSULT CLADDING

    MANUFACTURER FOR DETAILS,NOT BY KWS

    GAP BETWEEN RAILS TYPICALLYEQUALS 1.5x THE EXPECTED

    FLOOR MOVEMENT, MINIMUMOF 38" AND MAXIMUM OF 1"

    ThermaZee MUST NOT INFRINGE ONSTEEL STUD FLOOR DEFLECTION

    TRACK MOVEMENT

    KNIGHT ThermaZee™(HORIZONTAL ORIENTATION)RAINSCREEN ATTACHMENT

    07/15/2020

    *16 GAUGE RAILS, FACTORY BLACK COATED RAILS & STAINLESS STEEL(304) AVAILABLE

    *MAXIMUM ALLOWABLE SPACING AND DEAD LOAD (WEIGHT OFCLADDING) IS BASED ON THE TOTAL LOAD (DEAD + LIVE) ACTING ON THEASSEMBLY, BRACKETS AND CONNECTIONS. BACK TO TABLE OF CONTENTS

    THESE GUIDE DETAILS ARE PROVIDED FOR INFORMATION ONLYAND OUTLINE GENERAL/TYPICAL REQUIREMENTS FOR THEATTACHMENT SYSTEM. PROJECT SPECIFIC ENGINEERING ISAVAILABLE TO ADDRESS STRUCTURAL ATTACHMENT (i.e.FASTENING PATTERN, ETC.). CONTACT KWS FOR FURTHERDETAILS. ALL IMPLIED WARRANTIES INCLUDINGMERCHANTABILITY & FITNESS FOR A PARTICULARPURPOSE ARE EXPRESSLY EXCLUDED.www.knightwallsystems.com© Knight Wall Systems Deer Park, WA - 1.855.KWS.WALLPATENT US 8,429,866 B2, OTHERS PENDING - Drawn by: BN

    TYPICAL FLOOR DEFLECTION JOINT22 SCALE: 3" = 1'-0"

    Sheets and Viewsthermazee_horizontal-orientation_guide-details-TITLEthermazee_horizontal-orientation_guide-details-GENERAL NOTESthermazee_horizontal-orientation_guide-details-TOCthermazee_horizontal-orientation_guide-details-ASSEMBLY AXOthermazee_horizontal-orientation_guide-details-TZ 2-3.5thermazee_horizontal-orientation_guide-details-TZ 4-6thermazee_horizontal-orientation_guide-details-Z-ONLY SECTIONthermazee_horizontal-orientation_guide-details-Z-ONLY PLANthermazee_horizontal-orientation_guide-details-OSCthermazee_horizontal-orientation_guide-details-ISCthermazee_horizontal-orientation_guide-details-JAMBthermazee_horizontal-orientation_guide-details-HEAD-SILLthermazee_horizontal-orientation_guide-details-BASEthermazee_horizontal-orientation_guide-details-DEFL.thermazee_horizontal-orientation_guide-details-Z+PR SECTIONthermazee_horizontal-orientation_guide-details-Z+PR PLANthermazee_horizontal-orientation_guide-details-2 - OSCthermazee_horizontal-orientation_guide-details-2 - ISCthermazee_horizontal-orientation_guide-details-2 - JAMBthermazee_horizontal-orientation_guide-details-2 - HEAD-SILLthermazee_horizontal-orientation_guide-details-2 - BASEthermazee_horizontal-orientation_guide-details-2 - DEFL.